首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 671 毫秒
1.
GPS-synchronized measurements of electric (E) field changes induced by lightning flashes were recorded at six stations in the northeastern verge of the Tibetan Plateau. The height and magnitude of charge neutralized by 65 return strokes, including 16 negative cloud-to-ground (CG) flashes and 2 positive CG flashes, have been fitted with the nonlinear least-square method based on the E field changes of CG flashes observed in a typical thunderstorm with larger-than-usual lower positive charge center (LPCC). Results show that the height of the charge region neutralized by negative CG flashes ranges from 3 km to 5 km above the ground, corresponding to an ambient temperature between − 2 °C and − 15 °C. For the two positive CG flashes, the neutralized charge regions are located at a height of about 5.5 km and the ambient temperature is about − 18 °C, indicating the existence of upper positive charge in the thunderstorm.  相似文献   

2.
During the summers of 2003 to 2006 sprites were observed over thunderstorms in France by cameras on mountain tops in Southern France. The observations were part of a larger coordinated effort, the EuroSprite campaigns, with data collected simultaneously from other sources including the French radar network for precipitation structure, Meteosat with images of cloud top temperature and the Météorage network for detection of cloud-to-ground (CG) flash activity. In this paper two storms are analyzed, each producing 27 sprite events. Both storms were identified as Mesoscale Convective Systems (MCS) with a trailing stratiform configuration (ST) and reaching a maximum cloud area of ~ 120,000 km2. Most of the sprites were produced while the stratiform area was clearly developed and during periods of substantial increase of rainfall in regions with radar reflectivity between 30 and 40 dBZ. The sprite-producing periods followed a maximum in the CG lightning activity and were characterized by a low CG flash rate with a high proportion of + CG flashes, typically around 50%. All sprites were associated with + CGs except one which was observed after a − CG as detected by the Météorage network. This − CG was estimated to have − 800 C km charge moment change. The peak current of sprite-producing + CG (SP + CG) flashes was twice the average value of + CGs and close to 60 kA with little variation between the periods of sprite activity. The SP + CG flashes were further characterized by short time intervals before a subsequent CG flash (median value < 0.5 s) and with clusters of several CG flashes which suggest that SP + CG flashes often are part of multi-CG flash processes. One case of a lightning process associated with a sprite consisted of 7 CG flashes.  相似文献   

3.
利用2007-2018年浙江省ADTD闪电定位资料,分析了该地区多回击地闪分布及相关参数特征.结果表明:浙江省多回击地闪占总地闪的26.74%,其中正闪以单回击地闪为主;正、负闪平均回击数分别为1.04次和1.65次,最大回击数分别为5次和21次.回击数和地闪数存在较为一致的年际变化,正、负多回击地闪日变化分别呈多峰和...  相似文献   

4.
During the Eulinox (European Lightning Nitrogen Oxides Project) campaign, two lightning sensors were available: a Lightning Position and Tracking System (LPATS), and the ONERA VHF interferometric (ITF) mapper. We looked for the typical VHF signature of positive and negative cloud-to-ground flashes in ITF records in order to separate intra-cloud (IC) flashes from cloud-to-ground (CG) flashes during five periods from 2 days. Then we used this set of data to check the efficiency of the South Germany LPATS. We concluded that this LPATS detected nearly all the negative CG flashes, but one-fourth of LPATS negative strokes are in fact IC flashes. The ratio of misinterpretation is much smaller (15%) for multi-stroke negative CG flashes. The LPATS recorded 62% of the positive strokes, but only 43% with the right polarity, and only 25% of LPATS positive strokes actually belonged to a positive CG flash. This reliability ratio is 100% if we consider only high-intensity LPATS strokes.  相似文献   

5.
广州高建筑物雷电观测站光电同步观测系统于2017年6月16日记录到一次峰值电流达+141 kA的单回击正地闪触发两个并发上行闪电过程。利用高速摄像、普通摄像和电场变化数据分析了触发型上行闪电的始发特征和机理。结果表明:正地闪回击后约0.8 ms内,在距正地闪接地点约3.9 km的广州塔(高600 m)和4.1 km的东塔(高530 m)分别有上行闪电始发。正地闪回击过程中和大量正电荷以及之后可能有云内负先导朝高塔方向快速伸展造成塔顶局部区域的电场发生突变是两个上行闪电激发的原因。两个上行闪电在353 ms内发生7次回击,其中6次在广州塔上,仅1次在东塔上,且广州塔回击峰值电流平均值(-21.4 kA)约为东塔回击峰值电流(-7.3 kA)的3倍,表明广州塔上行闪电通道可能比东塔上行闪电通道伸展至分布范围更广、电荷量(或电荷密度)更大的负电荷区。两个上行闪电先导的二维速率变化范围为9.4×104~1.8×106 m·s-1,平均值为6.9×105 m·s-1。  相似文献   

6.
Intracloud (IC) and cloud-to-ground (CG) lightning flashes produce transient changes in the electric field (E) above a thundercloud which drive transient currents in the global electric circuit (GEC). Using in-cloud and above-cloud E data from balloons, ground-based E data, and Lightning Mapping Array data, the above-cloud charge transfers due to lightning transients are estimated for five IC and five CG flashes from four thunderstorms that occurred above the mountains in New Mexico, USA, in 1999. For the five CG flashes (which transferred − 4 to − 13 C to the ground), the transient currents moved + 1 to + 5 C of charge upward from cloudtop toward the ionosphere, with an average transient charge transfer of about 35% of the charge transferred to ground. For the five IC flashes (which neutralized 6 to 21 C inside the cloud), the transient currents moved − 0.7 to − 3 C upward, with an average transient charge transfer of about 12% of the lightning charge. Estimates for three thunderstorms indicate that the transient currents made only a small GEC contribution compared to the quasi-stationary Wilson currents because of the offsetting effects of IC and CG flashes in these storms. However, storms with extreme characteristics, such as high flash rates or predominance of one flash type, may make a significant GEC contribution via lightning transients.  相似文献   

7.
Study of the total lightning activity in a hailstorm   总被引:1,自引:0,他引:1  
A thunderstorm that developed over northeastern Spain on 16 June 2006 is analyzed. This severe thunderstorm produced hailstones as large as 40 mm and had a lifetime of 3 h and 30 min. Radar cross-sections show strong vertical development with cloud echo tops reaching an altitude of 13 km. The specific characteristics of the lightning activity of this storm were: (i) a large amount (81%) of negative cloud-to-ground (−CG) flashes with very low peak currents (< 10 kA in absolute value), (ii) a very large proportion of intra-cloud (IC) flashes with an IC/CG ratio reaching about 400, (iii) a large number of “short” IC flashes (with only 1-VHF source according to SAFIR detection), (iv) a large increase of the −CG flash rate and of the CG proportion near the end of the storm. The rate of −CG flashes with a low peak current were observed to evolve similarly to the rates of IC flashes. Most of them have been assumed to be IC flashes misclassified by the Spanish Lightning Detection Network (SLDN). They have been filtered as it is usually done for misclassified +CG flashes. After this filtering, CG flash rates remained very low (< 1 min− 1) with +CG flashes sometimes dominant. All the particular lightning activity characteristics similar to those observed in the Severe Thunderstorm Electrification and Precipitation Study (STEPS) campaigns support the hypothesis that this thunderstorm could have had an inverted-polarity or complex charge structure. The maximum IC flash rate (67 min− 1) peaked 24 min before the presence of reflectivity higher than 60 dBZ. The IC activity abruptly decreased during the period when reflectivity was dramatically increasing. The time of maximum reflectivity observed by radar was consistent with the times of reported hail at the ground.  相似文献   

8.
为进一步研究多回击地闪参数分布特征,以便为雷电防护工程设计和雷电物理研究提供参考,根据湖北省雷电定位系统(LLS)2007年1月-2018年12月监测资料,采用计算机编程处理和数理统计方法,对多回击地闪次数、多重回击次数和不同类型多回击地闪雷电流幅值等参数进行了统计分析.结果 表明:多回击正地闪、负地闪和总地闪次数占其...  相似文献   

9.
大兴安岭林区地闪放电特征的观测与分析   总被引:4,自引:2,他引:2  
利用2009年夏季在大兴安岭林区开展的雷暴及闪电的多站GPS同步观测资料,详细分析了该地区的地闪放电特征.通过对464次地闪资料的分析,发现具有单次回击的地闪所占的比例高达69,且正地闪比例较高,达到了22%.对连续电流的统计表明,约有27%的地闪伴随有连续电流过程且长连续电流过程主要出现在具有单次回击的负地闪中,其平...  相似文献   

10.
The characteristics of cloud-to-ground (CG) lightning for ten hailstorms in Shandong Province of China were analyzed statistically. It is found that the hailstorms in this study present dominant positive CG flashes during periods of falling hail. One specific hailstorm on 16 June 2006 was studied in detail using the data from a CG lightning location network, Doppler radar and cloud images. Comparison between the brightness temperature of cloud-top and CG flash locations indicated that most flashes occurred in the region with temperatures lower than − 40 °C, while dense positive CG flashes occurred in the range between − 40 °C and − 50 °C. Negative CG flashes occurred mostly in the relative weak radar echo region, and positive CG flashes were distributed in the strong echo region especially with a large gradient of echo intensity. CG flashes tended to occur in the cloud region with reflectivity between 25 dBZ and 35 dBZ. Comparison between the wind field retrieved from Doppler radar and the location of CG flashes indicated that the flashes were located in the convergent region at lower to middle levels.  相似文献   

11.
大兴安岭地区地闪回击辐射场特征   总被引:1,自引:0,他引:1  
利用慢电场变化测量仪所获取的观测资料详细分析了大兴安岭地区地闪回击辐射场特征。结果表明,35次正地闪首次回击的慢前沿、10%~90%平均上升时间分别为7.8μs、4.5μs,其中11次正地闪首次回击的过零时间、负反冲深度平均值分别为34μs、23%。76次负地闪首次回击的慢前沿、10%~90%平均上升时间分别为3.5μs、1.9μs,继后回击的慢前沿为1.4μs,其中15次负地闪首次回击的过零时间、负反冲深度平均值分别为51μs、52%。另外,正地闪首次回击的半峰值宽度大于负地闪首次回击,平均值分别为13.6μs、5.6μs。与国内外已有结果的进一步对比发现,大兴安岭地区的地闪回击辐射场特征与瑞典、美国弗罗里达的地闪回击辐射场特征有较好的一致性,但与我国内陆高原的地闪辐射场特征有明显差异。  相似文献   

12.
Lightning and Doppler radar observations of a squall line system   总被引:2,自引:0,他引:2  
A typical squall line with damaging wind and hailstones occurred on 28 April 2006 in Shandong Province, middle eastern China, and caused great economic loss. The characteristics of cloud-to-ground lightning (CG) in the squall line were studied in detail by combining the data from the ground-based CG location network, two Doppler radars and the Lightning Imaging Sensor on the TRMM satellite. Results show that positive CG flashes accounted for 54.7% of the total CG flashes. During the initial developing stage, the CG flash rate was lower than 0.5fl min− 1 and most of the CG flashes were positive. It increased significantly, up to 4.5fl min− 1, along with the rapid development of the squall line, and the percentage of positive CG was more than 75% during this period. The CG flash rate began to decrease but the percentage of negative CG flash increased gradually and exceeded that of positive CG during the mature and dissipating stages. Positive CG flashes tended to occur on the right flank and negative ones on the left flank. Strong wind at the surface occurred in or near the regions with dense positive CG flashes. Almost all positive CG flashes occurred near the strong radar echo regions, in the front parts of the squall line. However, the negative CG flashes almost exclusively occurred in the regions with weak and uniform radar echoes. The total flash rate in the storm was very high, up to 136fl min− 1, and its ratio of intracloud flashes (IC) to CG flashes was 35:1. Dense positive CG flashes corresponded to updraft regions, they did not occur in the core of the updraft, but just behind and close to the main updraft instead. The rear inflow jet, between 3 and 6 km, played an important role in the formation of the bow echo and very strong wind at surface. The CG distribution features in the squall line were obviously different from that of an ordinary MCS. The charge structure could be roughly described as an inverted charge structure.  相似文献   

13.
中国内陆高原地闪特征的统计分析   总被引:29,自引:3,他引:29  
利用微秒级时间分辨率的宽带慢天线电场变化仪首次在中国内陆高原地区对雷暴过程中的正、负地闪特征进行了测量和系统分析 ,发现每次雷暴过程中正闪的比例有随总闪频数增大而减少的趋势 ,弱雷暴过程更有利于正地闪的产生。平均来讲 ,正地闪占闪电总数的 16 % ,介于美国夏季雷暴和日本冬季雷暴之间。负地闪闪击间隔的算术平均值和几何平均值分别为 6 4.3ms和 46 .6ms。 5 4%的负地闪有至少一次继后回击强度大于首次回击 ,而且有 2 0 %的继后回击其强度大于首次回击强度。继后回击强度与首次回击强度的比例几何平均值为 0 .46 ,算术平均值为 0 .70 ,平均回击数为 3.76 ,39.8%为单次回击地闪。正地闪的多次回击只占 13.0 % ,且闪击之间的时间间隔也较大 ,算术平均值为 91.7ms。  相似文献   

14.
利用低光度相机首次观测到了2013年7月31日华北地区一次中尺度对流系统(MCS)上空产生的中高层Sprite放电现象。结合闪电定位、天气雷达等同步观测, 对一次MCS诱发的Sprite的形态学特征及其对应的母体闪电和雷暴系统的雷达回波特征等进行了详细分析。研究除发现了2例圆柱型、3例胡萝卜型和1例舞蹈型 Sprite外, 还发现了2例发光主体发育不完全的Y字型Sprite。估算的Sprite的底部平均高度低于61.8±3.5 km, 顶部平均高度为84.3±6.8 km。Sprite持续时间算术平均值为25.7±9.8 ms, 几何平均值为24.4 ms。Sprite的母体闪电均为正地闪, 峰值电流在+62.5~+106.2 kA之间, 算术平均值为+77.1±22.2 kA, 是本次MCS所有正地闪平均峰值电流的1.4倍。Sprite母体闪电的脉冲电荷矩变化(iCMC)在+475~+922 C km之间, 几何平均值为+571.0 C km。Sprite母体闪电发生在MCS雷达回波25~35 dBZ的层状云降水区, 弱回波(<30 dBZ)面积的突然增加对Sprite的产生有重要指示作用。Sprite易发生在MCS成熟—消散阶段正地闪比例(POP)显著增加的时段。在本次MCS消散阶段中, 有两个时间段可能有利于产生Sprite。在Sprite集中发生时间段, 北京闪电综合探测网(BLNET)探测到的正地闪比例为54.2%, 正地闪连续电流比例70.24%, 连续电流持续时间为58.17±50.31 ms, 有利于Sprite的产生。  相似文献   

15.
张廷龙  郄秀书  袁铁 《大气科学》2008,32(5):1221-1228
利用2002年夏季在青海省大通县进行的雷暴及闪电综合观测实验中所获取的6站GPS同步闪电电场变化资料,对8月4日一次下部具有大范围正电荷区的典型性雷暴过程的雷电特征进行详细研究。利用点电荷模式对16次负地闪和2次正地闪所包含的共65次回击所中和电荷源进行的非线性最小二乘法拟合研究发现,负地闪所中和的负电荷距离地面的相对高度在3~5 km,而两次正地闪所中和的雷暴云电荷在5~6 km的高度,表明该雷暴云呈三极性电荷结构。负地闪单次回击所中和电荷量平均为1.48 C,而两次正地闪都为单次回击且中和的电荷量分别为1.37 C和2.68 C。  相似文献   

16.
By using a high-speed video camera system (1000 frames s− 1) in correlation with fast and slow antenna systems, the negative cloud-to-ground (CG) flashes that struck the ground with more than one termination have been analyzed. This kind of stroke, named as multiple-ground terminations stroke (MGTS), was produced by different branches of the same stepped leader during quite a short time. Based on optical images, the 2D progression speed of leader branches was estimated to be in the range (0.9–2.0) × 105 m s− 1. The distance between adjacent striking points of MGTS was from 0.2 km to 1.9 km. The percentage of flashes with multiple-ground terminations occupied about 15% (9 out of 59) of the total negative CG flashes, with a range of 11%–20% in different areas in China. The time intervals between the two adjacent peaks ranged from 4 μs to 486 μs based on the E-field change caused by the MGTS. The flashes which had multiple striking points on the ground during quite a short time may be a common phenomenon in the lightning discharge process. It might produce more serious damage to facilities on the ground and should not be neglected in the design of lightning protection.  相似文献   

17.
This work analyses the waveshapes of continuing currents and parameters of M-components in positive cloud-to-ground (CG) flashes through high-speed GPS synchronized videos. The dataset is composed of only long continuing currents (with duration longer than 40 ms) and was selected from more than 800 flashes recorded in São José dos Campos (45.864°W, 23.215°S) and Uruguaiana (29.806°W, 57.005°S) in Southeast and South of Brazil, respectively, during 2003 to 2007 summers. The videos are compared with data obtained by the Brazilian Lightning Location System (BrasilDAT) in order to determine the polarity of each flash and select only positive cases. There are only two studies of waveshapes of continuing currents in the literature. One is based on direct current measurements of triggered lightning, in which four different types of waveshapes were observed; and the other is based on measurements of luminosity variations in high-speed videos of CG negative lightning, in which besides the four types above mentioned two additional types were observed. The present work is an extension of the latter, using the same method but now applied to obtain the waveshapes of positive CG lightning. As far as the authors know, this is the first report on M-components in positive continuing currents. We also have used the luminosity-versus-time graphs to observe their occurrence and measure some parameters (duration, elapsed time and time between two successive M-components), whose statistics are presented and compared in detail to the data for negative flashes. We have plotted a histogram of the M-components elapsed time over the total duration of the continuing current for positive flashes, which presented an exponential decay (correlation coefficient: 0.83), similar to what has been observed for negative flashes.  相似文献   

18.
利用三维(ADTD-2C)和二维(ADTD)闪电定位系统资料,对比分析了湖北省一次特大暴雨过程中两套系统闪电活动特征,得出以下结论:(1)本次过程中地闪多于云闪,二者均以负极性为主.(2)三维系统正地闪在地闪中的占比低于正云闪在云闪中的占比,高于二维系统正地闪在地闪中的占比.(3)三维系统雷电流幅值集中分布在0~30 ...  相似文献   

19.
In this study we analyze the effects of continuing current initiated by strokes following a new channel to ground in multiple stroke flashes using high-speed video records, electric field measurements from a fast antenna and lightning detection network data. We observed that the long continuing current initiated by a stroke that follows a new channel also obeys the pattern in the initiation of long continuing current suggested by Rakov and Uman [Rakov, V.A., Uman, M.A., 2003. Lightning: Physics and Effects, 687pp., Cambridge Univ. Press, New York.]. We also verify that the statement of Rakov and Uman [Rakov, V.A. and Uman, M.A., 1990. Some properties of negative cloud-to-ground lightning flashes versus stroke order, Journal of Geophysical Research. 95, 5447–5453.] reporting that: “...strokes initiating long continuing currents tend to have lower initial electric field peak than regular strokes” is valid for strokes that create a new channel to ground and are followed by long continuing current (CC). Apparently the reduction of peak current value (Ip) when the stroke is followed by a long CC is stronger than the Ip increase that is commonly observed when strokes follow a new channel. We also find that the “exclusion zone” proposed by Saba et al. [Saba, M.M.F., Pinto, O. Jr., Ballarotti, M.G., 2006a. Relation between lightning return stroke peak current and following continuing current, Geophysical Research Letters 33, L23807, doi:10.1029/2006GL027455.] is valid for new channels initiating CC, and finally we verify that a number of strokes in the same channel larger than four or the existence of a long CC current do not always consolidate the channel in a multiple stroke flash.  相似文献   

20.
广州地区雷暴过程云-地闪特征及其环境条件   总被引:5,自引:2,他引:3       下载免费PDF全文
应用雷电定位系统和高空观测资料并结合雷达回波资料, 对广州地区雷暴过程云-地闪特征进行分析, 并就有、无云-地闪出现的两组不同对流天气过程的环境条件进行了比较研究。结果表明:广州地区的雷暴过程以负的云-地闪为主, 负云-地闪所占比例在90%以上。云-地闪发生频率与雷暴系统强度演变有直接联系, 对于同一系统来说, 随着系统回波强度的增强, 云-地闪发生的频率也增高。但不同系统中, 云-地闪发生频率有很大不同, 回波强(弱)的对流系统并不意味着云-地闪发生的频率就高(低)。有云-地闪记录的对流天气过程具有更大的垂直切变、更高的相对风暴螺旋度以及更多的对流抑制能量, 云-地闪现象更易于出现在更加有组织和更强的对流系统中。研究还发现广州及周边城市区域对雷暴系统回波强度及云-地闪现象可能有影响, 两个典型个例分析表明, 雷暴系统移经城市区域时回波强度减弱, 云-地闪发生频率减小, 雷暴移过城市区域后, 强度可重新加强, 云-地闪发生频率增大。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号