1.
El Bahariya Oasis is a part of the great groundwater reservoir of the Western Desert of Egypt. The different stratigraphic units, the water-bearing zones, aquifer potentiality conditions, and the favorable locations for drilling new wells were evaluated by carrying out 24 Schlumberger vertical electrical soundings (VESs), along with the data of some wells drilled in the near vicinity of the measuring sites. The results of the interpreted field data revealed the presence of ten distinctive subsurface geoelectric layers; a thin surface, dry loose sand and gravel, sandy clay and shale interclations, saturated coarse sand layer, shale and clay, and saturated fine sandstone and saturated coarse sandstone. The aquifer is a multilayer aquifer with different thicknesses represented by the fourth, sixth, eighth, and tenth geoelectric layers. Results also revealed that the thicknesses of the water-bearing horizons increase towards the east direction, consequently the aquifer potentiality increases. Therefore, the best production well locations are in that direction. Depth to water starts from 40 m at VES no. 14 and increases gradually toward the east to reach 66 m at VES no. 5. Hydrogeochemical analysis of two groundwater samples taken from Ein El Ezza and well no. 2 showed that groundwater in the study area is suitable for agricultural purposes but not for human consumption due to the high iron content. Recommendations concerning site selection for drilling new productive groundwater wells are given.  相似文献   

2.
Siliyin spring is one of the many natural fresh water springs in the Western Desert of Egypt. It is located at the central part of El-Fayoum Delta, which is a potential place for urban developments and touristic activities. Integrated geoelectrical survey was conducted to facilitate mapping the groundwater resources and the shallow subsurface structures in the area. Twenty-eight transient electromagnetic (TEM) soundings, three vertical electrical soundings (VES) and three electrical resistivity tomography (ERT) profiles were carried out around the Siliyin spring location. The dense cultivation, the rugged topography and the existence of infra structure in the area hindered acquiring more data. The TEM data were inverted jointly with the VES and ERT, and constrained by available geological information. Based on the inversion results, a set of geoelectrical cross-sections have been constructed. The shallow sand to sandy clay layer that forms the shallow aquifer has been completely mapped underneath and around the spring area. Flowing of water from the Siliyin spring is interconnected with the lateral lithological changes from clay to sand soil. Exploration of the extension of Siliyin spring zone is recommended. The interpretation emphasizes the importance of integrating the geoelectrical survey with the available geological information to obtain useful, cheap and fast lithological and structural subsurface information.  相似文献   

3.
The current study aimed to evaluate hydrogeologically the Nubian sandstone aquifer in El-Bahariya Oasis. It represents the main water-bearing horizon in the study area and consists of continental elastic sediments, mainly sandstone alternating with shale and clays. The general flow lines are directed from SW to NE direction, as detected from the constructed potentiometric head contour map. The piezometric surface reaches 149 m in El-Heiz area at the southern part, while it reaches 90 m at the northern, reflecting higher pressure head of the aquifer in the southern part. The map also illustrates that the southern part is considered as the most promising location for development. The structural elements play an important role in the deposition and distribution of the sedimentary succession of the Nubian sandstone sediments. Consequently, this sedimentary pattern affects the occurrences and movements of the groundwater within the aquifer system. Along the structurally high areas, in the study area, the piezometric head increases, while the reverse is recorded along the structurally low areas. The step-drawdown tests data were carried out by calculating the aquifer loss coefficient (B) and the well loss constant (C). The B values are smaller compared with C values, indicating that the aquifer under pressure has a behavior of leaky aquifer; therefore, it shows hydraulic connection with surrounding formation. The values of well efficiency range from 78.50% to 87.76%. Analysis of 12 pumping test data (constant discharge tests) was carried out in order to calculate the Nubian aquifer hydraulic parameters (transmissivity, hydraulic conductivity, and storage coefficient). The transmissivity values decrease from 3,045 m2/day in the southern part (El-Heiz area) to 236 m2/day in the northeastern part (El-Harra area). Accordingly, the aquifer classified as a high to moderate potentiality. Transmissivity contour map observes gradual increase of transmissivity values from the southern to northeastern direction. This may be due to the increase of shale or clay content in the concerned aquifer in that direction. The storage coefficient values range between 1.04 × 10?4 and 5.22 × 10?3, as obtained from the results of pumping test analysis, which ensure that the Nubian sandstone aquifer is classified as semi-confined to confined aquifer type. The S values show a decrease from southwest to northeast direction as detected from S-map. The hydraulic conductivity values vary from to 0.46 m/day in the northern part to 10.88 m/day in the southern part with an average of 5.67 m/day. According to the classification based on K values, the aquifer is mainly composed of coarse sand.  相似文献   

4.
A combination of vertical electrical soundings (VES), 2D electrical resistivity imaging (ERI) surveys and borehole logs were conducted at Magodo, Government Reserve Area (GRA) Phase 1, Isheri, Southwestern Nigeria, with the aim of delineating the different aquifers present and assessing the groundwater safety in the area. The Schlumberger electrode array was adopted for the VES and dipole-dipole array was used for the 2D imaging. The maximum current electrode spread (AB) was 800 m and the 2D traverse range between 280 and 350 m in the east-west direction. The thickness of impermeable layer overlying the confined aquifer was used for the vulnerability ratings of the study area. Five lithological units were delineated: the topsoil, clayey sand, unconsolidated sand which is the first aquifer, a clay stratum and the sand layer that constitutes the confined aquifer horizon. The topsoil thickness varies from 0.6 to 2.6 m, while its resistivity values vary between 55.4 and 510.6 Ω/m. The clayey sand layers have resistivity values ranging from 104.2 to 143.9 Ω/m with thickness varying between 0.6 and 14.7 m. The resistivity values of the upper sandy layer range from 120.7 to 2195.2 Ω/m and thickness varies from 3.3 to 94.0 m. The resistivity of the clay layer varies from 11.3 to 96.1 Ω/m and the thickness ranges from 29.6 to 76.1 m. The resistivity value of the confined aquifer ranges between 223 and 1197.4 Ω/m. The longitudinal conductance (0.0017–0.02 mhos) assessment of the topsoil shows that the topsoil within the study area has poor overburden protective capacity, and the compacted impermeable clay layer shows that the underlying confined aquifer is well protected from contamination and can be utilized as a source of portable groundwater in the study area. This study therefore enabled the delineation of shallow aquifers, the variation of their thicknesses and presented a basis for safety assessment of groundwater potential zones in the study area.  相似文献   

5.
Electrical geophysical surveys in the mode of vertical electrical soundings (VES) and continuous vertical electrical soundings (CVES) were conducted in the León-Chinandega plains, northwestern Nicaragua, in order to obtain detailed information about the geometry of the different hydrogeological layers in the aquifer and depth to the basement. A total of 51 VES were carried out within the plains. The results show a complex structure towards the north east of the area, and the southwestern part of the plains presents a smoother stratification. The geoelectrical measurements and borehole information indicate that the basement topography is characterized by hills and deep valleys with highly variable basement depths. Fifty CVES where done in a smaller area in the center of the plain. The resistivity data yielded considerable information revealing the existence of two main geo-electrical units. The combined interpretation of geological and geophysical data shows an environment typical of sedimentary volcanic coastal plains. The information collected during this investigation provides valuable data for estimating the fresh-water resources of the León-Chinandega aquifer system and for development of a groundwater management plan.  相似文献   

6.
Geoelectrical resistivity investigation using Vertical Electrical Sounding (VES) technique was conducted at Port Blair, South Andaman Island, to locate the fractures in different formations and to decipher its groundwater potential. A total of 40 VES were carried out covering the entire study area using Schlumberger electrode configuration out of which 34 VES fall in Andaman Flysch formations and the remaining VES in Ophiolite formations. The interpreted resistivity results were integrated with nine borehole lithologs for the subsurface analysis. The combination of VES with borehole litholog data has provided a close correspondence on subsurface hydrogeological conditions. The interpreted VES data of various formations showed drastic variations in the resistivity ranging from higher in Ophiolite, moderate in Andaman Flysch and very low in valleys of Andaman Flysch formations. The study further revealed that the weathered and fractured volcanics of Ophiolite groups of rocks and sandstone that occur in the Andaman Flysch formations constitute the productive water bearing zones categorized as good groundwater potential zone. Based on the geoelectrical parameters, viz., thickness of layers and the layer resistivity values, a groundwater potential map was prepared, in which good, moderate, and poor groundwater zones were demarcated. Further, numerical, spatial and litho-geoelectric models of resistivity were analyzed in terms of groundwater potential and these models have thus enabled to prepare a comprehensive groundwater development and management plans proving its efficacy in this art of exploratory investigations.  相似文献   

7.
The integrated geophysical interpretation for the different geophysical tools such as resistivity and gravity is usually used to define the structural elements, stratigraphic units, groundwater potentiality, and depth to the basement rocks. In the present work, gravity and resistivity data were utilized for detecting the groundwater aquifer and structural elements, as well as the upper and lower surfaces of the subsurface basaltic sheet in an area located at the eastern side of Ismailia Canal, northeastern Greater Cairo, Egypt. Two hundred and ten gravity stations were measured using an Autograv instrument through a grid pattern of 50?×?50 m. The different required corrections were carried out, such as drift, elevation, tide, and latitude corrections. The final corrected data represented by the Bouguer anomaly map were filtered using high- and low-pass filters into regional and residual gravity anomaly maps. The resulting residual gravity anomaly map was used for gravity modeling to calculate the depths to the upper and lower surfaces of the basaltic sheet. The resulting gravity models indicated that the depths to the upper surface of the basaltic sheet are ranged between 26 and 314 m, where the shallower depths were found around the southern and eastern parts. The depths to the lower surface of the basaltic sheet are varied from 86 to 338 m, and the thickness of the basaltic sheet is ranged from 24 to 127 m, where the biggest thicknesses were found around the southern and northern parts of the study area. Forty-two vertical electrical soundings (VES) were carried out using Schlumberger configuration with AB/2 spacings ranged from 1.5 to 500 m. 1D quantitative interpretation was carried out through manual and analytical interpretations. The VES data were also inverted assuming a 3D resistivity distribution. The results from the 3D resistivity inversion indicated that the subsurface section consists of sand, sandstone, and sandy–clays of Miocene deposits overlying the basalts. Such basaltic features (of Oligocene age) are underlain by Gabal Ahmar Formation of Oligocene deposits, which are composed of sand and sandstone. Therefore, two aquifers were deduced in the area. The first is the Miocene aquifer (shallower) and the other is the Oligocene aquifer (deeper).  相似文献   

8.
The El Minia governorate lies within the Nile Valley, surrounded by calcareous plateaus to the east and west. The present study focuses on the hydrogeochemistry of the Eocene limestone aquifer at some wadis in the east El Minia governorate, Eastern Desert, Egypt. Hydrogeologically, two main aquifers are encountered in the study area, namely the Maghagha marly limestone and the Samalut chalky limestone aquifers. The Maghagha aquifer is composed of alternating layers of marly limestone and shale with thicknesses ranging from 3.49 m to 177.05 m and a groundwater depth ranging from 8.5 m to 59.27 m which reflects low groundwater potentiality. The groundwater salinity representing this aquifer ranges from 603.5 mg/L to 978.5 mg/L, reflecting fresh water type. Samalut aquifer is made up of chalky, cavernous and fractured limestone with thickness ranging from 30 m to 205 m and groundwater depth ranging from 9 m to 86.77 m, which indicates good groundwater potential. The groundwater salinity of the concerned aquifer ranges from 349.7 mg/L to 2043.9 mg/L, reflecting fresh to possibly brackish water types. Groundwater in the study area is of meteoric water origin; recent recharge is mainly controlled through the presence of fractures and their densities. The majority of groundwater samples in the study area are suitable for drinking and irrigation purposes.  相似文献   

9.
Electrical imaging of the groundwater aquifer at Banting,Selangor, Malaysia   总被引:1,自引:0,他引:1  
A geophysical study was carried out in the Banting area of Malaysia to delineate groundwater aquifer and marine clay layer of the alluvial Quaternary deposits of Beruas and Gula Formations. The Beruas Formation is formed by peat and clayey materials as well as silt and sands, whereas the Gula Formation consists of clay, silt, sand and gravels. Both Formations were deposited on top of the Carboniferous shale of the Kenny Hill Formation. A 2-D geoelectrical resistivity technique was used. Resistivity measurement was carried out using an ABEM SAS 4000 Terrameter. The 2-D resistivity data of subsurface material for each survey line was calculated through inverse modelling and then compared with borehole data. The resistivity images of all the subsurface material below the survey lines show similar pattern of continuous structure of layering or layers with some lenses with resistivity ranging from 0.1 to 50 Ωm. The upper layer shows resistivity values ranging from 0.1 to 10 Ωm, representing a clay horizon with a thickness up to 45 m. The second layer with depth varies from 45 to 70 m below surface and has resistivity values ranging from 10 to 30 Ωm. Borehole data indicate coarse sand with some gravels for this layer, which is also the groundwater aquifer in the study area. The lowermost layer at a depth of 70 m below ground level shows resistivity values ranging from 30–50 Ωm and can be correlated with metasedimentary rocks consisting of shale and metaquartzite.  相似文献   

10.
A novel study on using geoelectrical resistivity, soil property, and hydrogeochemical analysis methods for delineating and mapping of heavy metal in aquifer system is presented in this paper. A total of 47 surveys of geoelectrical resistivity with Wenner configuration were conducted to determine the subsurface and the groundwater characteristics. The groundwater sample from 53 existing wells and 2 new wells has been analyzed to derive their water chemical content. The chemical analysis was done on the soil sample obtained from new two wells and from selected locations. The water and soil chemical analysis results from the new two wells were used as calibration in resistivity interpretation. The occurrence of heavy metal in aquifer system was expected to detect using the geoelectrical resistivity survey for the whole study area. The result of groundwater analysis shows that the groundwater sample contains a relatively low concentration of Fe (<?0.3 mg/L) elongating from the south up to the middle region. While in the middle and the northwestern, Fe concentration is relatively high (around 12 mg/L). Chemical analysis of soil sample shows that in the lower resistivity zone (<?18 Ωm), Al and Fe concentrations are comparatively high with an average of 68,000 and 40,000 mg/kg, respectively. Starting from the middle to the northwestern zone, the resistivity value appears to be low. It is definitely caused by higher Al and Fe concentration within the soil, and it is supported also by lower total anion content in the groundwater. While the resistivity value of more than 40 Ωm in aquifers is obtained in the zone which Fe concentration is relatively lower in the soil but not present in the groundwater. Correlation Fe concentration in the soil and Fe concentration in the groundwater sample shows the trend of positively linear; however, the Al concentration in soil has no correlation with Al content in groundwater. Finally, the probability of high heavy metal zone in the aquifer system is easily delineated by the distribution of geoelectrical resistivity presented in depth slice shapes which extend from the Boundary Range Composite Batholith in the north to the northwest.  相似文献   

11.
Recently, the deterioration of water quality in the coastal zones of Lekki Peninsula area of Lagos due to saltwater infiltration into the freshwater aquifer has become a major concern. With the aim of providing valuable information on the hydrogeologic system of the aquifers, the subsurface lithology and delineating the groundwater salinity, vertical electrical resistivity (VES) sounding survey was carried out utilizing surface Schlumberger electrode arrays, and electrode spacing varying between 1 and 150 m. The DC resistivity surveys revealed significant variations in subsurface resistivity. Also, the VES resistivity curves showed a dominant trend of decreasing resistivity with depth (thus increasing salinity). In general, the presence of four distinct resistivity zones were delineated viz.: the unconsolidated dry sand (A) having resistivity values ranging between 125 and 1,028 Ωm represent the first layer; the fresh water-saturated soil (zone B) having resistivity values which correspond to 32–256 Ωm is the second layer; the third layer (zone C) is interpreted as the mixing (transition) zone of fresh with brackish groundwater. The resistivity of this layer ranges from 4 to 32 Ωm; while layer four (zone D) is characterized with resistivities values generally below 4 Ωm reflecting an aquifer possibly containing brine. The rock matrix, salinity and water saturation are the major factors controlling the resistivity of the formation. Moreover, this investigation shows that saline water intrusion into the aquifers can be accurately mapped using surface DC resistivity method.  相似文献   

12.
The city of Burdur, which is built on an alluvium aquifer, is located in one of the most seismically active zones in southwestern Turkey. The soil properties in the study site are characterized by unconsolidated and water-saturated sediments including silty, clayey and sandy units, and shallow groundwater level is the other characteristic of the site. Thus, the city is under soil liquefaction risk during a large earthquake. A resistivity survey including 189 vertical electrical sounding (VES) measurements was carried out in 2000 as part of a multi-disciplinary project aiming to investigate settlement properties in Burdur city and its vicinity. In the present study, the VES data acquired by using a Schlumberger array were re-processed with 1D and 2D inversion techniques to determine liquefaction potential in the study site. The results of some 1D interpretations were compared to the data from several wells drilled during the project. Also, the groundwater level map that was previously obtained by hydrological studies was extended toward north by using the resistivity data. 2D least-squares inversions were performed along nine VES profiles. This provided very useful information on vertical and horizontal extends of geologic units and water content in the subsurface. The study area is characterized by low resistivity distribution (<150 Ωm) originating from high fluid content in the subsurface. Lower resistivity (3–30 Ωm) is associated with the Quaternary and the Tertiary lacustrine sediments while relatively high resistivity (40–150 Ωm) is related to the Quaternary alluvial cone deposits. This study has also shown that the resistivity measurements are useful in the estimation of liquefaction risk in a site by providing information on the groundwater level and the fluid content in the subsurface. Based on this, we obtained a liquefaction hazard map for the study area. The liquefaction potential was classified by considering the resistivity distributions from 2D inversion of the VES profiles, the types of the sediments and the extended groundwater level map. According to this map, the study area was characterized by high liquefaction hazard risk.  相似文献   

13.
Integrated geoelectrical and hydrochemical surveys were used to investigate and delineate different types of groundwater in the Kuala Selangor alluvial aquifer. Previous hydrogeological borehole investigation showed that this aquifer contains several types of groundwater in relation to its salinity. The high salinity of the groundwater in some areas is believed to be due to either saltwater intrusion from the nearby sea or river infiltration during high tide season. The vertical electrical sounding (VES) method was employed to study and map the subsurface variation of resistivity in the area. For each sounding measurement, a total spread length of 300 m was obtained with a vertical depth penetration of about 60 to 75 m. Chemical analysis of the groundwater samples taken from both shallow and deep boreholes was carried out for the water quality determination. A total of 45 VES stations were succesfully established along three parallel roads with a direction almost perpendicular to the coastal line. The distance between stations varies from 1 to 2 km with a maximum length of about 60 km surveyed line. Results of the vertical electrical soundings as well as the hydrochemistry of the groundwater samples show that the soil and groundwater in the study area can be grouped into fresh and brackish water zones. The subsurface resisitivity sections derived from the VES study suggest that the area is dominated by brackish soil and groundwater zones, especially in the area towards the coast. This result appears to agree well with the groundwater pumped from boreholes scattered around in the area. Water drawn from boreholes near the coast showed higher salinity compared to the water pumped from inland boreholes. Chloride values greater than 250 mg/L are considered to represent the brackish zones whilst values less than 250 mg/L represents zones of fresh soil and groundwater.  相似文献   

14.
The Nubian Sandstone Aquifer (NSSA) is the main groundwater resource of the El-Bahariya Oasis, which is located in the middle of the Western Desert of Egypt. This aquifer is composed mainly of continental clastic sediments of sandstone with shale and clay intercalations of saturated thickness ranging between 100 and 1500 m. Vulnerability assessment to delineate areas that are more susceptible to contamination from anthropogenic sources has become an important element for sustainable resources management and land use planning. Accordingly, this research aims to estimate the vulnerability of NSSA by applying the DRASTIC model as well as utilising sensitivity analyses to evaluate the relative importance of the model parameters for aquifer vulnerability in the study area. The main objective is to demonstrate the combined use of the DRASTIC and the GIS techniques as an effective method for groundwater pollution risk assessment, and mapping the areas that are prone to deterioration of groundwater quality and quantity. Based on DRASTIC index (DI) values, a groundwater vulnerability map was produced using the GIS. The aquifer analysis in the study area highlighted the following key points: the northeastern and western parts of the NSSA were dominated by ‘High’ vulnerability classes while the northwestern and southeastern parts were characterised by ‘Medium’ vulnerability classes. The elevated central part of the study area displayed ‘Low’ aquifer vulnerability. The vulnerability map shows a relatively greater risk imposed on the northeastern part of the NSSA due to the larger pollution potential of intensive vegetable cultivation. Depth-to-water, topography and hydraulic conductivity parameters were found to be more effective in assessing aquifer vulnerability.  相似文献   

15.
Twenty profiles of vertical electric soundings (VES) were obtained in a riverside alluvium at the Buyeo area, South Korea, to examine the variations of subsurface geology and associated groundwater chemistry. The combination of the VES data with the borehole data provided useful information on subsurface hydrogeologic conditions. The vestige of an ancient river channel (e.g. oxbow lake) was identified on the resistivity profiles by the lateral continuation of a near-surface perched aquifer parallel to the river. Such a perched aquifer is typically developed in the area with a clay-rich silty surface alluvium which prohibits the infiltration of oxygen. Therefore, groundwater below the oxbow lake shows a very low nitrate concentration and Eh values under the strong anoxic condition. The distribution of water resistivity is correlated with that of measured total dissolved solids concentration in groundwater, while the earth resistivity of the aquifer shows a significant spatial variation. It is interpreted that the earth resistivity of the aquifer is mainly controlled by the soil type rather than by the water chemistry in the study area.  相似文献   

16.
Twenty seven vertical electrical sounding (VES) profiles surrounding four known traverses were obtained in Ngor-Okpala local government area of Imo state to examine the subsurface geomaterials and the associated groundwater potential. The VES data, constrained by borehole data, provided useful information about the subsurface hydrogeologic and lithologic conditions. From the validated interpretation, the area assessed has loamy soil, medium grained sands, well-sorted medium-grained/gravelly sands and river sand as the lithologic succession from top to the bottom of the depth penetrated. The aquifers in the area were found in the medium-grained sands and well-sorted medium-coarse-grained sands. The aquifer depth for all-season groundwater that would be devoid of draw-down can be found at a depth range of 42–50 m. The resistivity maps of selected depths exhibit sharp resistivity changes at depth due mainly to undulating subsurface topography. A map of the distribution of the kσ-values shows that good quality groundwater can be found in most parts of the area.  相似文献   

17.
Integrated hydrogeochemical and geophysical methods were used to study the salinity of groundwater aquifers along the coastal area of north Kelantan. For the hydrogeochemical investigation, analysis of major ion contents of the groundwater was conducted, and other chemical parameters such as pH and total dissolved solids were also determined. For the geophysical study, both geoelectrical resistivity soundings and reflection seismic surveys were conducted to determine the characteristics of the subsurface and groundwater contained within the aquifers. The pH values range from 6.2 to 6.8, indicating that the groundwater in the study area is slightly acidic. Low content of chloride suggests that the groundwater in the first aquifer is fresh, with an average concentration of about 15.8 mg/l and high geoelectrical resistivity (>45 ohm m). On the other hand, the groundwater in the second aquifer is brackish, with chloride concentration ranging from 500 mg/l to 3,600 mg/l and very low geoelectrical resistivity (<45 ohm m) as well as high concentration of total dissolved solids (>1,000 mg/l). The groundwater in the third aquifer is fresh, with chloride concentrations generally ranging from 2 mg/l to 210 mg/l and geoelectrical resistivity of greater than 45 ohm m. Fresh and saltwater interface in the first aquifer is generally located directly in the area of the coast, but, for the second aquifer, both hydrogeochemical and geoelectrical resistivity results indicate that the fresh water and saltwater interface is located as far as 6 km from the beach. The considerable chloride ion content initially suggests that the salinity of the groundwater in the second aquifer is probably caused by the intrusion of seawater. However, continuous monitoring of the chloride content of the second aquifer indicated no significant changes with time, from which it can be inferred that the salinity of the groundwater is not affected by seasonal seawater intrusion. Schoeller diagrams illustrate that sulphate concentrations of the groundwater of the second aquifer are relatively low compared to those of the recent seawater. Therefore, this result suggests that the brackish water in the second aquifer is probably from ancient seawater that was trapped within the sediments for a long period of time, rather than due to direct seawater intrusion.  相似文献   

18.
El Alamein-El-Dabaa area lies in the western Mediterranean coastal zone of Egypt with about 50 km long. The aims of the present study are the shallow groundwater aquifer determination and calculate the electric parameters of the overburden to achieve the easiest way for detecting groundwater contamination and considered it during the planning of new development project(s). To attain this target, 44 vertical resistivity soundings using Schlumberger array of the maximum AB/2?=?1000 m in the form of four profiles were carried out. From the interpretation results, six geoelectrical layers have been established in the area, and iso-resistivity, depth to water, and isopach contour maps are presented. Four geoelectrical cross-sections (two geoelectrical cross-sections are parallel to the Mediterranean shoreline and the other two are normal to the Mediterranean shoreline) have been constructed. According to this work, the upper part of the Oolitic Limestone represents the shallow groundwater aquifer in this area and can be distinguished into two zones. The upper zone is brackish, whereas the lower one is saline. The geoelectrical succession reveals that the aquifer is free type. The depth to water ranges between 20 and 63 m; therefore, it is the choice as the best sites for groundwater exploitation. In the area under study, the depth to water and the thickness of the brackish increase towards the south side as well as the depth to the brackish water. The Dar-Zarrouk parameters clarified that there are some parts that may contaminate pathways and other parts are not.  相似文献   

19.
A large number of valleys and basin systems are present in the northwestern part of the Himalayas in Pakistan which form significant aquifers in the region. Hydrogeophysical investigations in the western part of Nowshera District, a part of the intermontane Peshawar basin, were undertaken to help to determine the availability of groundwater resources in the region. Thirty vertical electrical resistivity soundings (VES) were acquired using a Schlumberger expanding array configuration with a maximum current electrode spacing (AB/2) of 150 m in delineating the groundwater potential in the study area. The results of the interpreted VES data using a combination of curve matching technique and computer iterative modeling methods suggest that the area is underlain by 3 to 5 geo-electric layers. The interpretation results showed that the geo-electrical succession consists of alluvium comprising of alternating layers of clay, silty clay, fine to coarse sands, sand with gravels and gravels of variable thickness. High subsurface resistivity values are correlated with gravel–sand units and low resistivity values with the presence of clays and silts. The modeled VES results were correlated with the pumping tests results and lithological logs of the existing wells. The pumping test suggests the transmissivity of the aquifer sediments is variable corresponding to different sediments within the area. The gravel–sand intervals having high resistivity value show high transmissivity values, whereas clay–silt sediments show low transmissivities. It is concluded that majority of the high resistive gravel–sand sediments belong to an alluvial fan environment. These gravel–sand zones are promising zones for groundwater abstraction which are concentrated in the central part of the study area.  相似文献   

20.
Two geophysical techniques were integrated to map the groundwater aquifers on complex geological settings, in the crystalline basement terrain in northeast Nuba Mountains. The water flow is structurally controlled by the northwest–southeast extensional faults as one of several in-situ deformational patterns that are attributed to the collision of the Pan-African oceanic assemblage of the Nubian shield against the pre-Pan African continental crust to the west. The structural lineaments and drainage systems have been enhanced by the remote sensing technique. The geophysical techniques used are: vertical electrical soundings (VES) and electrical resistivity tomography (ERT), in addition to hydraulic conductivity measurements. These measurements were designed to overlap in order to improve the producibility of the geophysical data and to provide a better interpretation of the hydrogeological setting of the aquifer complex structure. Smooth and Block inversion schemes were attempted for the observed ERT data to study their reliability in mapping the different geometries in the complex subsurface. The VES data was conducted where ERT survey was not accessible, and inverted smoothly and merged with the ERT in the 3D resistivity grid. The hydraulic conductivity was measured for 42 water samples collected from the distributed dug wells in the study area; where extremely high saline zones were recorded and have been compared to the resistivity values in the 3D model.  相似文献   