首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Calcium isotopic compositions of sixteen Ca‐bearing USGS geological reference materials including igneous and sedimentary rocks are reported. Calcium isotopic compositions were determined in two laboratories (GPMR, State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan; and CIG, Centre for Isotope Geochemistry, University of California, Berkeley) using the 42Ca‐48Ca double‐spike technique by thermal ionisation mass spectrometry. As opposed to common cation exchange resin, a micro‐column filled with Ca‐selective resin (DGA resin) was used in order to achieve high recovery (> 96%) and efficient separation of Ca from the sample matrix. The intermediate measurement precision was evaluated at 0.14‰ (2s) for δ44/40CaSRM915a at GPMR, based on replicate measurements of pure Ca reference material NIST SRM 915a, NIST SRM 915b and seawater. Overall, the measurement uncertainties in both laboratories were better than 0.15‰ at the 2s level. Result validation was carried out for all available data sets. The Ca isotopic compositions of USGS reference materials are not only in agreement between GPMR and CIG, but also in agreement with previously published data within quoted uncertainties. The comprehensive data set reported in this study serves as a reference for both quality assurance and interlaboratory comparison of high precision Ca isotopic study.  相似文献   

2.
In this study, to evaluate whether bias free Ca isotope ratios can be properly achieved by thermal ionisation mass spectrometry (TIMS) using the 42Ca–43Ca double‐spike technique without chemical purification, a series of comparable experiments (with or without column chemistry) were made on Ca‐dominated minerals and rocks. Minerals, including fluorite, calcite, titanite and apatite, displayed similar Ca isotope ratios with Δ44/40Cawith‐without ranging from ?0.02 to +0.07‰. For Ca‐rich rocks, we mainly focused on the carbonates since they are the main repositories of Ca at the surface of the Earth. Coral, stalagmite, carbonatite, dolomite, marble and limestone are studied here. Interestingly, δ44/40CaSRM 915a of these minerals and rocks without chemical purification displayed little drift compared with that of rocks with chemical purification, with Δ44/40Cawith‐without merely spanning from ?0.04 to +0.04‰. This implies that Ca isotope ratios can be achieved without column chemistry, possibly due to a property of TIMS in which Ca ions are only ionised at a target temperature and with a specific activator without ionising other ions. Therefore, for Ca‐dominated minerals or rocks, we suggest that column chemistry is unnecessary if they are totally dissolved and mixed in proper proportion with the 42Ca–43Ca double spike for TIMS measurement.  相似文献   

3.
We report mass‐independent and mass‐dependent Ca isotopic compositions for thirteen geological reference materials, including carbonates (NIST SRM 915a and 915b), Atlantic seawater as well as ten rock reference materials ranging from peridotite to sandstone, using traditional ε and δ values relative to NIST SRM 915a, respectively. Isotope ratio determinations were conducted by independent unspiked and 43Ca‐48Ca double‐spiked measurements using a customised Triton Plus TIMS. The mean of twelve measurement results gave ε40/44Ca values within ± 1.1, except for GSP‐2 that had ε40/44Ca = 4.04 ± 0.15 (2SE). Significant radiogenic 40Ca enrichment was evident in some high K/Ca samples. At an uncertainty level of ± 0.6, all reference materials had the same ε43/44Ca and ε48/44Ca values. We suggest the use of δ44/42Ca to report mass‐dependent Ca isotopic compositions. The precision under intermediate measurement conditions for δ44/42Ca over eight months in our laboratory was ± 0.03‰ (with n ≥ 8 repeat measurements). Measured igneous reference materials gave δ44/42Ca values ranging from 0.27‰ to 0.54‰. Significant Ca isotope fractionation may occur during magmatic and metasomatism processes. Studied reference materials with higher (Dyn/Ybn) tend to have lower δ44/42Ca, implying a potential role of garnet in producing magmas with low δ44/42Ca. Sandstone GBW07106 had a δ44/42Ca value of 0.22‰, lower than all igneous rocks studied so far.  相似文献   

4.
The advent of multiple collector-inductively coupled plasma-mass spectrometry has provided an impetus to the study of isotope abundance variations in natural materials. In particular, the study of "non-traditional" stable isotopes has revealed isotope fractionation variations caused by a range of physiochemical and biological mechanisms. The magnitude of these variations may be < 1 per mil per mass unit, but are significant in terms of the experimental uncertainties involved, provided rigorous mass spectrometric protocols are followed. The double spike technique can be used effectively to evaluate isotope fractionation effects for both multiple collector-inductively coupled plasma-mass spectrometry and thermal ionisation mass spectrometry. The demanding nature of this research implies the need for internationally-accepted reference materials so that interlaboratory comparisons can be made with confidence. At present, isotopically certified reference materials are unavailable for many elements, including Cu, Zn, Mo and Cd, and it is important that this situation be rectified as soon as practicable. Until such time as isotopically certified reference materials become available for every element, stable isotope geochemists should adopt a common reference material as the standard for each element so that rigorous interlaboratory comparisons can be made.  相似文献   

5.
Measurement of Ba isotope ratios of widely available reference materials is required for interlaboratory comparison of data. Here, we present new Ba isotope data for thirty‐four geological reference materials, including silicates, carbonates, river/marine sediments and soils. These reference materials (RMs) cover a wide range of compositions, with Ba mass fractions ranging from 6.4 to 1900 µg g?1, SiO2 from 0.62% to 90.36% m/m and MgO from 0.08% to 41.03% m/m. Accuracy and precision of our data were assessed by the analyses of duplicate samples and USGS rock RMs. Barium isotopic compositions for all RMs were in agreement with each other within uncertainty. The variation of δ138/134Ba in these RMs was up to 0.7‰. The shale reference sample, affected by a high degree of chemical weathering, had the highest δ138/134Ba (0.37 ± 0.03‰), while the stream sediment obtained from a tributary draining carbonate rocks was characterised by the lowest δ138/134Ba (?0.30 ± 0.05‰). Geochemical RMs play a fundamental role in the high‐precision and accurate determination of Ba isotopic compositions for natural samples with similar matrices. Analyses of these RMs could provide universal comparability for Ba isotope data and enable assessment of accuracy for interlaboratory data.  相似文献   

6.
The Cr isotope ratios of terrestrial and extra-terrestrial materials are emerging as one of the most important tracers in geosciences. Previous studies on Cr isotopic measurements using TIMS have found that there is residual Cr isotopic fractionation between the mass-fractionation-corrected 53Cr/52Cr and 54Cr/52Cr ratios, which may cause an offset of obtained ratios from the reference values. The residual fractionation was thought to be caused by the evaporation of Cr-oxide species during thermal ionisation, but the mechanism by which this residual fractionation could be reduced remained unclear. Here we revisit the issue of residual fractionation and propose that this problem can be alleviated by utilising W filaments instead of conventionally used Re filaments for Cr ionisation. Using W filaments, the formation of CrO+ was suppressed during heating as the filament temperature was ~ 100 °C lower than when Re filaments were used. In repeated measurement of a carbonaceous chondrite, the intermediate precisions of 53Cr/52Cr and 54Cr/52Cr ratios in the W filament runs were two to three times better than those of the Re filament runs. Therefore, the new finding of this study will be of key importance for future studies of Cr isotopes for terrestrial and extra-terrestrial materials.  相似文献   

7.
Molybdenum concentrations in eleven USGS geochemical reference materials AGV-1, BCR-1, BHVO-1, BIR-1, DNC-1, DTS-1, G-2, GSP-1, MAG-1, PCC-1 and W-2 were measured by isotope dilution thermal ionisation mass spectrometry (ID-TIMS). In every case but one, the concentrations determined in this study were significantly lower than the current consensus values. Molybdenum concentrations determined by ID-TIMS are inherently more accurate and precisions may be up to an order of magnitude higher than those measured by other analytical techniques.  相似文献   

8.
The interest in variations of barium (Ba) stable isotope amount ratios in low and high temperature environments has increased over the past several years. Characterisation of Ba isotope ratios of widely available reference materials is now required to validate analytical procedures and to allow comparison of data obtained by different laboratories. We present new Ba isotope amount ratio data for twelve geological reference materials with silicate (AGV‐1, G‐2, BHVO‐1, QLO‐1, BIR‐1, JG‐1a, JB‐1a, JR‐1 and JA‐1), carbonate (IAEA‐CO‐9) and sulfate matrices (IAEA‐SO‐5 and IAEA‐SO‐6) relative to NIST SRM 3104a. In addition, two artificially fractionated in‐house reference materials BaBe12 and BaBe27 (δ137/134Ba = ?1.161 ± 0.049‰ and ?0.616 ± 0.050‰, respectively) are used as quality control solutions for the negative δ‐range. Accuracy of our data was assessed by interlaboratory comparison between the University of Bern and the United States Geological Survey (USGS). Data were measured by MC‐ICP‐MS (Bern) and TIMS (USGS) using two different double spikes for mass bias correction (130Ba–135Ba and 132Ba–136Ba, respectively). MC‐ICP‐MS measurements were further tested for isobaric and non‐spectral matrix effects by a number of common matrix elements. The results are in excellent agreement and suggest data accuracy.  相似文献   

9.
报道了三种玄武岩标准样品(BCR-2、BIR-1a和GBW 07105)的铁铜锌同位素数据。实验使用HNO3-HF混合酸消解玄武岩标准样品;AGMP-1阴离子交换树脂分离提纯样品中的铜铁锌,利用多接收等离子体质谱仪(MC-ICPMS)测定铁铜锌同位素比值,分析过程中使用样品-标准-样品交叉法校正仪器的质量分馏。实验得到BCR-2、BIR-1a和GBW 07105标准样品的高精度铁铜锌同位素组成(95%置信水平的不确定度)分别为:δ56FeBCR-2-IRMM014=0.070‰±0.018‰(2SD),δ65 CuBCR-2-SRM976=0.16‰±0.04‰(2SD),δ66 ZnBCR-2-IRMM3702=-0.072‰±0.020‰(2SD);δ56 FeBIR-1a-IRMM014=0.044‰±0.026‰(2SD),δ65CuBIR-1a-SRM976=0.027‰±0.019‰(2SD),δ66 ZnBIR-1a-IRMM3702=0.085‰±0.032‰(2SD);δ56FeGBW 07105-IRMM014=0.126‰±0.039‰(2SD),δ65 CuGBW 07105-SRM976=0.12‰±0.01‰(2SD),δ66ZnGBW 07105-IRMM3702=0.22‰±0.03‰(2SD)。这些数据在误差(不确定度)范围内与国际上已发表的数据是一致的。三个玄武岩标准样品的铁铜锌同位素组成数据的发表为铁铜锌同位素研究提供了统一的标准,使地质样品的铁铜锌同位素数据的质量监控成为可能。  相似文献   

10.
The interest in the study of gallium (Ga) stable isotope fractionation in low‐ and high‐temperature environments has increased significantly in the last few years. However, a unified reference material (RM) is still lacking for the Ga isotope research community, which hinders interlaboratory comparison between different groups. Consequently, certification of Ga isotopic reference materials for interlaboratory comparison is of high priority. In this study, Ga isotope ratio data for ten geological RMs including silicates, shales and ferromanganese nodules, and two pure Ga RMs including NIST SRM 994 and NIST SRM 3119a reported by three different groups, were determined by MC‐ICP‐MS. Sample matrices of geological RMs were separated by a two‐column separation method with the use of AG MP‐1M and AG 50‐X8 resin, separately, and quantitative recoveries of > 99% Ga were obtained for all geological RMs. Instrumental mass bias was corrected by the combined calibrator‐sample bracketing and internal normalisation model. Validation of the proposed method was performed by analysing synthetic solutions. After normalisation of all available δ71Ga data of geological RMs to a single Ga RM, results obtained in our study are in agreement with previously reported results.  相似文献   

11.
We have developed a new database named GeoReM ( http://georem.mpch-mainz.gwdg.de ) for reference materials and isotopic standards of geochemical and mineralogical interest. Reference samples include rock powders originating from the USGS, GSJ, GIT-IWG, synthetic and natural reference glasses originating from NIST, USGS, MPI-DING, as well as mineral (e.g., 91500 zircon), isotopic (e.g., La Jolla, E&A, NIST SRM 981), river water and seawater reference materials. GeoReM is a relational database, which strongly follows the concept of the three EARTHCHEM databases. It contains published analytical and compilation values (major and trace element concentrations, radiogenic and stable isotope ratios), important metadata about the analytical values, such as uncertainty, uncertainty type, method and laboratory. Sample information and references are also included. Three different ways of interrogating the database are possible: (1) sample names or material types, (2) chemical criteria and (3) bibliography. Some typical applications are described. GeoReM currently (October 2005) contains more than 750 geological reference materials, 6000 individual sets of results and references to 650 publications.  相似文献   

12.
Here we describe high‐precision molybdenum isotopic composition measurements of geological reference materials, performed using multi‐collector inductively coupled plasma‐mass spectrometry (MC‐ICP‐MS). Purification of Mo for isotopic measurements was achieved by ion exchange chromatography using Bio‐Rad AG® 1‐X8 anion exchange resin. Instrumental mass bias was corrected using 100Mo‐97Mo double spiking techniques. The precision under intermediate measurement conditions (eighteen measurement sessions over 20 months) in terms of δ98/95Mo was 0.10‰ (2s). The measurement output was approximately four times more efficient than previous techniques, with no compromise in precision. The Mo isotopic compositions of seven geochemical reference materials, seawater (IAPSO), manganese nodules (NOD‐P‐1 and NOD‐A‐1), copper‐molybdenum ore (HV‐2), basalt (BCR‐2) and shale (SGR‐1b and SCo‐1), were measured. δ98/95Mo values were obtained for IAPSO (2.25 ± 0.09‰), NOD‐P‐1 (?0.66 ± 0.05‰), NOD‐A‐1 (?0.48 ± 0.05‰), HV‐2 (?0.23 ± 0.10‰), BCR‐2 (0.21 ± 0.07‰), SCo‐1 (?0.24 ± 0.06‰) and SGR‐1b (0.63 ± 0.02‰) by calculating δ98/95Mo relative to NIST SRM 3134 (0.25‰, 2s). The molybdenum isotopic compositions of IAPSO, NOD‐A‐1 and NOD‐P‐1 obtained in this study are within error of the compositions reported previously. Molybdenum isotopic compositions for BCR‐2, SCo‐1 and SGR‐1b are reported for the first time.  相似文献   

13.
Calcium Isotopic Composition of Various Reference Materials and Seawater   总被引:1,自引:0,他引:1  
A compilation of δ44/40Ca (δ44/40Ca) data sets of different calcium reference materials is presented, based on measurements in three different laboratories (Institute of Geological Sciences, Bern; Centre de Géochimie de la Surface, Strasbourg; GEOMAR, Kiel) to support the establishment of a calcium isotope reference standard. Samples include a series of international and internal Ca reference materials, including NIST SRM 915a, seawater, two calcium carbonates and a CaF2 reference sample. The deviations in δ44/40Ca for selected pairs of reference samples have been defined and are consistent within statistical uncertainties in all three laboratories. Emphasis has been placed on characterising both NIST SRM 915a as an internationally available high purity Ca reference sample and seawater as representative of an important and widely available geological reservoir. The difference between δ44/40Ca of NIST SRM 915a and seawater is defined as -1.88 O.O4%o (δ44/42CaNISTSRM915a/Sw= -0.94 0.07%o). The conversion of values referenced to NIST SRM 915a to seawater can be described by the simplified equation δ44/40CaSa/Sw44/40CaSa/NIST SRM 915a - 1.88 (δ44/42CaSa/Sw44/42CaSa/NIST SRM 915a - 0.94). We propose the use of NIST SRM 915a as general Ca isotope reference standard, with seawater being defined as the major reservoir with respect to oceanographic studies.  相似文献   

14.
Iron Isotopic Compositions of Geological Reference Materials and Chondrites   总被引:2,自引:0,他引:2  
High‐precision iron isotopic compositions for Fe‐bearing geological reference materials and chondrites with a wide range of matrices (e.g., silicates, oxides, organic‐bearing materials) are reported. This comprehensive data set should serve as a reference for iron isotopic studies across a range of geological and biological disciplines for both quality assurance and inter‐laboratory calibration. Where comparison is available, the iron isotopic compositions of most geological reference materials measured in this study were in agreement with previously published data within quoted uncertainties. Recommendations for the reporting of future iron isotopic data and associated uncertainties are also presented. Long‐term repeat analyses of all samples indicate that highly reproducible iron isotopic measurements are now obtainable (± 0.03‰ and ± 0.05‰ for δ56Fe and δ57Fe, respectively).  相似文献   

15.
We present boron isotope and concentration data from magmatic (komatiitic to rhyolitic) and sedimentary geological silicate and artificial glass reference materials that cover a wide spectrum of boron isotope compositions and boron concentrations. Boron isotope compositions were determined by TIMS (Cs2BO2+ -graphite and BO2- method) and boron concentrations by ICP-AES. Boron concentrations ranged from 7 to 159μ g-1 and agree within 14% with published values. Based on replicate analyses of individually prepared sample aliquots an overall external reproducibility of better than 10% was determined. The obtained δ11B values ranged from -12.6 to +13.6% and were reproducible within 1.1 % (2 RSD; excluding NTIMS) on the basis of individually prepared sample aliquots. The δ11B values of JA-1 (+5.3%), JB-3 (+5.9%) and JR-2 (+2.9%) overlap the published data within analytical uncertainty. For the first time δ11B values for the TB (-12.6%) and the MPI-DING glasses GOR-128-G (+13.6%), GOR-132-G (+7.1 %) and StHs6/80-G (-4.5%) are reported. The δ11B values obtained by the Cs2BO2+ -graphite and the BO2- method as well as the majority of δ11B values obtained using different sample preparation methods agree within analytical uncertainty. Therefore, we conclude that none of these analytical methods introduce any systematic error on the obtained δ11B values.  相似文献   

16.
Magnesium Isotope Compositions of Natural Reference Materials   总被引:1,自引:0,他引:1  
This study presents a chemical protocol for the separation of Mg that is particularly adapted to alkali‐rich samples (granite, soil, plants). This protocol was based on a combination of two pre‐existing methods: transition metals were first removed from the sample using an AG‐MP1 anion‐exchange resin, followed by the separation of alkalis (Na, K) and bivalent cations (Ca2+, Mn2+ and Sr2+) using a AG50W‐X12 cation‐exchange resin. This procedure allowed Mg recovery of ~ 10 0 ± 8%. The [Σcations]/[Mg] molar ratios in all of the final Mg fractions were lower than 0.05. The Mg isotope ratios of eleven reference materials were analysed using two different MC‐ICP‐MS instruments (Isoprobe and Nu Plasma). The long‐term reproducibility, assessed by repeated measurements of Mg standard solutions and natural reference materials, was 0.14‰. The basalt (BE‐N), limestone (Cal‐S) and seawater (BCR‐403) reference materials analysed in this study yielded δ26Mg mean values of ?0.28 ± 0.08‰, ?4.37 ± 0.11‰ and ?0.89 ± 0.10‰ respectively, in agreement with published data. The two continental rocks analysed, diorite (DR‐N) and granite (GA), yielded δ26Mg mean values of ?0.50 ± 0.08‰ and ?0.75 ± 0.14‰, respectively. The weathering products, soil (TILL‐1) and river water (NIST SRM 1640), gave δ26Mg values of ?0.40 ± 0.07‰ and ?1.27 ± 0.14‰, respectively. We also present, for the first time, the Mg isotope composition of bulk plant and organic matter. Rye flour (BCR‐381), sea lettuce (Ulva lactuva) (BCR‐279), natural hairgrass (Deschampsia flexuosa) and lichen (BCR‐482) reference materials gave δ26Mg values of ?1.10 ± 0.14‰, ?0.90 ± 0.19‰, ?0.50 ± 0.22‰ and ?1.15 ± 0.27‰ respectively. Plant δ26Mg values fell within the range defined by published data for chlorophylls.  相似文献   

17.
A procedure for the determination of chlorine by the isotope dilution technique (ID) using negative thermal ionisation mass spectrometry (N-TIMS) is described. Silicate samples of about 10 mg were spiked and decomposed with hydrofluoric acid, and chlorine was isolated by precipitation of silver chloride after neutralisation with Ca(OH)2. The ammonical solution of AgCl was then subjected to N-TIMS. Replicate analyses of rock reference materials, typically of JB-1 and JR-1, demonstrated the high quality of the analyses (precision for Cl was ± 1-2%). We present here the most precise data sets of chlorine concentrations in nine igneous rock reference materials, three basalts (JB-1, JB-2, JB-3), two andesites (JA-3, AGV-1), two rhyolites (JR-1, JR-2) and two granodiorites (JG-3, GSP-1). The chlorine concentrations found ranged from 152 μg g-1 in AGV-1 to 1008 μg g-1 in JR-1. Our results presented here are partly (but not completely) in agreement with recommended values, where they are available. The N-TIMS ID technique can thus be used as a means of determining low chlorine contents in silicate materials to high precision.  相似文献   

18.
The double‐spike method with multi‐collector inductively coupled plasma‐mass spectrometry was used to measure the Mo mass fractions and isotopic compositions of a set of geological reference materials including the mineral molybdenite, seawater, coral, as well as igneous and sedimentary rocks. The long‐term reproducibility of the Mo isotopic measurements, based on two‐year analyses of NIST SRM 3134 reference solutions and seawater samples, was ≤ 0.07‰ (two standard deviations, 2s, n = 167) for δ98/95Mo. Accuracy was evaluated by analyses of Atlantic seawater, which yielded a mean δ98/95Mo of 2.03 ± 0.06‰ (2s, n = 30, relative to NIST SRM 3134 = 0‰) and mass fraction of 0.0104 ± 0.0006 μg g?1 (2s, n = 30), which is indistinguishable from seawater samples taken world‐wide and measured in other laboratories. The comprehensive data set presented in this study serves as a reference for quality assurance and interlaboratory comparison of high‐precision Mo mass fractions and isotopic compositions.  相似文献   

19.
Magnesium isotopic compositions are reported for twenty‐four international geological reference materials including igneous, metamorphic and sedimentary rocks, as well as phlogopite and serpentine minerals. The long‐term reproducibility of Mg isotopic determination, based on 4‐year analyses of olivine and seawater samples, was ≤ 0.07‰ (2s) for δ26Mg and ≤ 0.05‰ (2s) for δ25Mg. Accuracy was tested by analysis of synthetic reference materials down to the quoted long‐term reproducibility. This comprehensive dataset, plus seawater data produced in the same laboratory, serves as a reference for quality assurance and inter‐laboratory comparison of high‐precision Mg isotopic data.  相似文献   

20.
Chromium (Cr) isotopes have been widely used in various fields of Earth and planetary sciences. However, high‐precision measurements of Cr stable isotope ratios are still challenged by difficulties in purifying Cr and organic matter interference from resin using double‐spike thermal ionisation mass spectrometry. In this study, an improved and easily operated two‐column chemical separation procedure using AG50W‐X12 (200–400 mesh) resin is introduced. This resin has a higher cross‐linking density than AG50W‐X8, and this higher density generates better separation efficiency and higher saturation. Organic matter from the resin is a common cause of inhibition of the emission of Cr during analysis by TIMS. Here, perchloric and nitric acids were utilised to eliminate organic matter interference. The Cr isotope ratios of samples with lower Cr contents could be measured precisely by TIMS. The long‐term intermediate measurement precision of δ53/52CrNIST SRM 979 for BHVO‐2 is better than ± 0.031‰ (2s) over one year. Replicated digestions and measurements of geological reference materials (OKUM, MUH‐1, JP‐1, BHVO‐1, BHVO‐2, AGV‐2 and GSP‐2) yield δ53/52CrNIST SRM 979 results ranging from ?0.129‰ to ?0.032‰. The Cr isotope ratios of geological reference materials are consistent with the δ53/52CrNIST SRM 979 values reported by previous studies, and the measurement uncertainty (± 0.031‰, 2s) is significantly improved.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号