1.
Six low abundance rock reference materials (basalt BIR-1, dunite DTS-1, dolerite DNC-1, peridotite PCC-1, serpentine UB-N and basalt TAFAHI) have been analysed for high field strength elements (Zr, Nb, Hf, Ta, Th and U), Rb, Sr, Mo, Sb, Cs, Tl and Bi at ng g−1 levels (in rock) by magnetic sector inductively coupled plasma-mass spectrometry after HF/HClO4 high pressure decomposition. The adopted method uses only indium as an internal standard. Detection limits were found to be in the range of 0.08 to 16.2 pg ml−1 in solution (equivalent to 0.08 to 16.2 ng g−1 in rock). Our data for high field strength elements, Rb, Sr, Mo, Sb, Cs, Tl and Bi for the six selected low abundance geological reference materials show general agreement with previously published data. Our Ta values in DTS-1 and PCC-1 (1.3 and 0.5 ng g−1) are lower than in previously published studies, providing smooth primitive mantle distribution patterns. Lower values were also found for Tl in BIR-1, DTS-1 and PCC-1 (2, 0.4 and 0.8 ng g−1). Compared with quadrupole ICP-MS studies, the proposed magnetic sector ICP-MS method can generally provide better detection limits, so that the measurement of high field strength elements, Rb, Sr, Mo, Sb, Cs, Tl and Bi at ng g−1 levels can be achieved without pre-concentration, ion exchange separation or other specialised techniques.  相似文献   

2.
We present a new method that determines precisely and accurately rare earth elements (REE) at the sub-ng g-1 level in ultramafic rocks based on acid dissolution and quadrupole ICP-MS with systematic interference corrections on each sample. The method is demonstrated by analyses of the international geochemical reference materials, PCC-1 (peridotite), DTS-1 (dunite) and DTS-2 (dunite) provided by the United States Geological Survey (USGS), and JP-1 (peridotite) issued by the Geological Survey of Japan (GSJ). Detection limits, as rock equivalent, were calculated to be 0.01-0.08 ng g-1 for our instrument, which is sufficiently low compared to the REE concentrations of ultramafic rocks. In addition, procedural blanks of the proposed method were 0.2-5 pg, which is negligible even for the ultra-low level REE determinations. Reproducibility obtained from separate dissolutions and measurements of USGS DTS-2 and GSJ JP-1 was 3-6%, which corresponds to the high-precision data obtained by ID-TIMS or magnetic sector field ICP-MS with a desolvating nebuliser. The REE data determined exhibit smooth chondrite-normalised REE patterns for all of the tested geochemical reference materials, and the abundances are in good agreement with recently published data.  相似文献   

3.
Rare earth element analyses are widely used in geology, environmental science and archaeology. Over the past decade inductively coupled plasma-mass spectrometry has become an important source of rare earth data on geological material. However, ICP-MS analysis of rock samples without pre-concentration can be problematic because of complex sample matrices that can generate significant molecular isobaric interferences on rare earth peaks and which need to be corrected. Such problems are exacerbated for ultramafic rocks because the low levels of rare earth elements demand more concentrated solutions in order to maintain signals above background levels. These high solid loads result in intra-run changes in instrument sensitivity which need to be monitored. Pre-concentration chemistries have been developed in order to avoid high solid loads but these are time-consuming and must offer quantitative recoveries or use a yield tracer. Here, we describe an alternative method for rare earth element analysis by ICP-MS, which involves no pre-concentration and is, therefore, able to deliver data rapidly. Our approach is to apply an external correction procedure, based on the analysis of a reference material closely matched in composition to the unknown samples, which allows correction for both interferences and variations in instrument sensitivity. Testing this method, we obtained accurate rare earth element results for basaltic rocks with a precision of about 2% (1s). We demonstrate that the method is also applicable to ultramafic rocks with abundances at ultra-trace (ng g−1) level and present data for twelve separate dissolutions of the peridotite USGS PCC-1 and four separate dissolutions of the dunite DTS-1 reference materials. The repeatability of the data is between 3% and 9% (1s).  相似文献   

4.
New concentrations for Au, Ir and Ag obtained by instrumental neutron activation analysis are presented for seventy geochemical reference materials. Results in agreement with literature values for Au and Ir down to concentrations of a few ng g−1 were obtained. For Au and Ir concentrations above 10 ng g−1, the repeatability of replicate analyses of reference materials was mostly better than 10%. For concentrations between 1 and 10 ng g−1 the RSD for Ir was 10–30%, whereas for Au it was higher and more variable (20–50%). In addition, concentrations for Cd and Hg are presented for some of the same reference materials. The high RSD at relatively high concentrations seen in gold for some RMs (e.g., WMG-1, WMS-1) did not exist for Ir and suggests homogeneity for this platinum-group element at the sub-sample size used in this study. For the following eight RMs, mostly ultramafic rocks (CHR-Pt+, OREAS-13P, OREAS-14P, PCC-1, UMT-1, WMG-1, WMS-1, WPR-1), Ir measurements agreed within ± 10% of mostly certified or recommended concentrations, which ranged from 2 ng g−1 to 6 μg g−1. For the reference material UB-N, iridium concentration compared favourably to published results obtained by isotope dilution ICP-MS methods and a previously unrecognised heterogeneity is inferred for Au, Hg and Sb, but not for the other measured elements.  相似文献   

5.
The high sensitivity, minimal oxide formation and single internal standard capability of high resolution inductively coupled plasma-mass spectrometry (HR-ICP-MS) is demonstrated in the direct determination of Sc, Y and REE in the international reference materials: basalts (BCR-1, BHVO-1, BIR-1, DNC-1), andesite (AGV-1) andultramafics (UB-N, PCC-1 and DTS-1). Time consuming ion exchange separation or preconcentration were found to be unnecessary. Smooth chondrite normalized plots of the REE in PCC-1 and DTS-1 were obtained in the range 0.8-50 ng g-1 (0.01-0.1x chondrite). Method precision was found to be digestion dependent with an average external repeatability of 2-4% for the basalts, AGV-1 and UB-N, and 10% for PCC-1 and DTS-1. The mass peak due to 45Sc was completely resolved from 29Si16O and 28Si16O1H spectral interferences using medium resolution, which casts doubt on the accuracy of Sc determinations using quadrupole ICP-MS. Literature values for Y in rock reference materials were found to be approximately 9% high after HR-ICP-MS and XRF analysis.  相似文献   

6.
The direct analysis of nickel sulfide fire assay buttons by UV laser ablation ICP-MS was used to determine the platinum-group elements and gold in the following reference materials: UMT-1, WPR-1, WMG-1, GPt-4, GPt-6 and CHR-Bkg. The instrument was calibrated with buttons prepared using quartz doped with the appropriate standard solutions. Analytical precision (RSD) was generally better than 10%, although occasional higher RSDs may infer local heterogeneities within nickel sulfide buttons. Good or excellent agreement was observed between analysed and reference material values except Rh in UMT-1 and WMG-1, which suffered an interference from copper. Detection limits calculated as 10 s quantitation limits were Au (1.7 ng g−1), Pd (3.3 ng g−1), Pt (8.3 ng g−1), Os (1.3 ng g−1), Rh (1 ng g−1), Ru (5 ng g−1) and Ir (0.7 ng g−1).  相似文献   

7.
Fifty-two trace elements in NIST SRM 614, 616 and MPI-DING BM90/21-G glass reference materials as well as in NIST SRM 612, USGS BCR2-G and other MPI-DING reference glasses (KL2-G, GOR132-G, GOR128-G, ATHO-G, Tl-G, StHs6/80-G and ML3B-G) were determined by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). Accurate ultra-low trace element abundances in the NIST SRM 614, 616 and BM90/21-G reference glasses down to lower ng g−1 levels were determined with relative standard deviations (RSD) of less than 10%. Limits of detection using He as carrier gas were up to two times lower than with Ar and were 0.004 to 0.12 μg g−1 for elements of lower mass numbers (amu < 85) and 0.002 to 0.06 μg g−1 for elements having amu < 85. The measured concentrations generally agree within 15% with previous studies except for B in NIST SRM 614 and 616, which appears to be heterogeneously distributed, and Co, Zn, Ga and Ag in NIST SRM 616 for which the existing data set is too small to evaluate the discrepancies. New values for As (0.593 μg g−1), Ag (0.361 μg g−1) and Cd (0.566 μg g−1) in NIST SRM 614 and new values for Na (94864 μg g−1) and As (0.276 μg g−1) in NIST SRM 616 are reported.  相似文献   

8.
We report new data on the trace element concentrations of Mg, Cr, Mn, Co, Ni, Cu, Zn, Sr, Cd, Ba, La, Ce, Nd, Pb and U in USGS carbonate reference materials (MACS-1 and MACS-2) and compare solution ICP-MS and LA-ICP-MS trace element determinations on landfill calcites using calibration to different reference materials (MACS-1 and MACS-2 carbonate and NIST SRM 612 glass). Very good agreement (differences below 10% relative) was found between laser ablation and solution ICP-MS data for MACS-1 with higher concentrations of trace elements (values between 100 and 150 μg g−1), with the exception of Cu and Zn. Similarly good agreement was found for MACS-2 with lower trace element concentrations (units to tens of μg g−1), with the exception of Cr, Co and Zn. The MACS-1 reference material for calibration of LA-ICP-MS was found to be extremely useful for in situ determination of trace elements in real-world carbonate samples (landfill calcites), especially those present in calcite in higher concentrations (Mn, Sr, Ba; < 5% RSD). Less accurate determinations were generally obtained for trace elements present at low concentrations (∼ units of μg g−1). In addition, good agreement was observed between the instrument calibration to MACS and NIST SRM 612 glass for in situ measurements of trace elements in landfill calcites K-2, K-3 and K-4 (differences below 15% relative for most elements). Thus, the application of MACS carbonate reference materials is promising and points to the need for the development of new carbonate reference materials for laser ablation ICP-MS.  相似文献   

9.
A simple and reliable method to separate rare earth elements (REE) from Mg, Fe, K, Na, Ca and Ba in ultramafic rocks has been developed, thereby concentrating their abundances. The sample (0.3 g) was digested with HF and HNO3 in a PTFE bomb, placed in a stainless steel container and, after drying, the insoluble residue was dissolved in 6 ml of 10% v/v HNO3. Following the addition of 50% triethanolamine and 30% m/v NaOH solution, the REE were precipitated along with Mg(OH)2, such that the majority of Fe, K and Na in the solution could be separated by centrifuging. The precipitate was dissolved in 1 ml HNO3 and a buffer solution of NH4Cl/NH4OH at pH = 9.0 was added to precipitate the REE along with any remaining Fe as Fe(OH)3, and so achieve separation from Mg, Ca and Ba, which remained in the solution. In this way, REE could be separated from major elements and were concentrated by a factor of about 60. The recovery of REE was more than 95% using this method. Four ultramafic rock reference materials, PCC-1 (USGS), JP-1 (GSJ), DZE-1, DZE-2 (IGGE) and one new proficiency testing sample GeoPT12 (GAS Serpentinite) were analysed by ICP-MS using indium as an internal standard. The quantitation limits were about 0.02–0.2 ng g−1. Smooth chondrite-normalised REE patterns were obtained with a precision for REE determination of about 2–9%.  相似文献   

10.
Data are reported for rare earth elements (REE) in three geological glass reference materials (BIR-1G, BHVO-2G and BCR-2G) using a UV (266 nm) laser ablation ICP-MS system and the classical (HF-HClO4) acid decomposition method, followed by conventional nebulisation ICP-MS. External calibration of laser ablation analyses was performed using NIST SRM reference materials with internal standardisation using 29Si and 44Ca. Replicate analyses of reference basaltic glasses yielded an analytical precision of 1-5% (RSD) for all the elements by solution ICP-MS and 1-8% (RSD) by laser ablation ICP-MS. The relative differences between the REE concentrations measured by solution and laser ablation ICP-MS compared with the reference values were generally less than 11 % for most elements. The largest deviations occurred for La determined by solution ICP-MS in BIR-1G. The results of both solution and laser ablation ICP-MS agreed well, generally better than 7%, with the exception of La, Pr and Sm in BIR-1G. The measured REE laser ablation data for BIR-1G, BHVO-2G and BCR-2G agreed with the previously published data on these basaltic reference glasses, within a range of 0-10% for most elements. No significant influences were observed for the predicted spectral interferences on some REE isotopes in the analysis of basaltic glasses.  相似文献   

11.
The microanalytical capability of laser ablation microprobe-inductively coupled plasma-mass spectrometry (LAM-ICP-MS) to determine ultra trace elemental concentrations has been demonstrated by the analysis of two low concentration glass standard reference materials, NIST SRM 614 and 616. Results for fifty two elements at concentrations in the low ng g-1 range are compared with those determined using secondary ion mass spectrometry (SIMS). Both techniques provide results at these concentrations that generally agree within 95% confidence limits, demonstrating the accuracy for ultra-trace level of in situ determinations by the two techniques. At concentrations of less than 20 ng g-1 in NIST SRM 616, an accuracy and precision of better than 10% has been obtained for most mono-isotopic rare earth elements, when a spot size of 50 μm is used. Limits of detection for selected elements were as low as 0.5 ng g-1.  相似文献   

12.
We found that the suppression of signals for 88Sr, 140Ce and 238U in rock solution caused by rock matrix in ICP-MS (matrix effects) was reduced at high power operation (1.7 kW) of the ICP. To make the signal suppression by the matrix negligible, minimum dilution factors (DF) of the rock solution for Sr, Ce and U were 600, 400 and 113 at 1.1, 1.4 and 1.7 kW, respectively. Based on these findings, a rapid and precise determination method for Rb, Sr, Y, Cs, Ba, REE, Pb, Th and U using FI (flow injection)-ICP-MS was developed. The amount of the sample solution required for FI-ICP-MS was 0.2 ml, so that 1.8 mg sample was sufficient for analysis with a detection limit of several ng g-1. Using this method, we determined the trace element concentrations in the USGS rock reference materials, DTS-1, PCC-1, BCR-1 and AGV-1, and the GSJ rock reference materials, JP-1, JB-1, -2, -3, JA-1, -2 and -3. The reproducibilities (RSD %) in replicate analyses (n=5) of BCR-1, AGV-1, JB-1, -2, -3, JA-1, -2, and -3 were < 6 %, and typically 2.5%. The difference between the average concentrations of this study for BCR-1 and those of the reference values were < 2%. Therefore, it was concluded that the method can give reliable data for trace elements in silicate rocks.  相似文献   

13.
We present new concentration data for twenty four lithophile trace elements in NIST certified reference material glasses SRM 610-SRM 611 in support of their use in microanalytical techniques. The data were obtained by solution ICP-MS and isotope dilution TIMS analysis of two different sample wafers. An overall assessment of these new results, also taking into account ion probe studies that have been published in the literature, shows that these wafers can be considered to be homogeneous. Therefore, individually analysed wafers are believed to be representative of the entire batch of the SRM 610-611 glasses. Possible exceptions are the alkali metals (and a few volatile or non-lithophile trace elements). The analysed concentrations range between 370 μg g−1 (Cs) and 500 μg g−1 (Sr) and agree well with published values. On the basis of our new data and data recently published in the literature we propose "preferred average" values for the elements studied. These values are, within a few percent, identical to those proposed by other workers.  相似文献   

14.
A method for the selective separation of Ag, Cd, Cr, Cu, Ni, Pb and Zn in traces from solutions of calcite (CaCO3), dolomite (CaMg(CO3)2) and gypsum (CaSO4.2H2O) before their determination by inductively coupled plasma-atomic emission spectrometry (ICP-AES) is presented. The expected interferences of Ca and Mg on intensities of trace analytes were removed by collecting the elements of interest with cobalt(III) hexamethylenedithiocar-bamate, Co(HMDTC)3. The flotation of aqueous solutions (1 l) of calcite, dolomite and gypsum was performed at pH 6.0, by 1.5 mg l−1 Co and 0.6 mmol l−1 HMDTC. To minimise the effect of the reaction between Ca/Mg, which restrains the function of the surfactant, careful selection of the most suitable foaming reagent was necessary. The accuracy of the method was established by analysing natural alkaline-earth minerals by the standard addition method as well as using the dolomite reference materials GBW 07114 and GSJ JDo-1. The ICP-AES limits of detection following flotation on different minerals were found to be 0.080 μg g−1 for Cd, 0.105 μg g−1 for Ag, 0.142 μg g−1 for Cu, 0.195 μg g−1 for Cr, 0.212 μg g−1 for Ni, 0.235 μg g−1 for Zn and 0.450 μg g−1 for Pb.  相似文献   

15.
The contents of total carbon, hydrogen, nitrogen and sulfur in twenty-seven geological reference materials, issued by five producer organisations (USGS, CCRMP, ANRT, NIST and GSJ) were determined using an automated simultaneous elemental analyser following combustion. In order to complete gasification of C and N in some geological materials, the combustion temperature needed to be greater than 1150 °C. The calibrator prepared from known amounts of reagent material was not adopted for more than 1.2% m/m of H. Unrealistically high values in certain materials supposed to contain less than 1000 μg g−1 S may be due mainly to memory effects. The limit of detection was 50 μg g−1 for C and N, 500 μg g−1 for H and 1000 μg g−1 for S. Although the blank value of C and N was always stable and less than one third of the detection limit, it had a slightly higher value for N and S. By repeating long-term analysis, high reproducibility for each of the four elements was verified. The method has been applied satisfactorily to a variety of geological reference materials, and recommended values for C, H and N for most of the reference materials studied have been tabulated.  相似文献   

16.
Fifty elements in NIST SRM 614 and 616 glass reference materials were determined by laser ablation microprobe-inductively coupled plasma-mass spectrometry (LAM-ICP-MS). The values determined for NIST SRM 614 agreed well with the NIST-certified and information values (mean relative difference ± 3.6%), except for B, Sc and Sb. The values determined for NIST SRM 616 agreed with the NIST-certified and information values within a mean relative difference of ± 1.5%, except for B, Sc and Ga. In addition, at an 80 μm sampling scale, NIST SRM 614 and 616 glass discs were homogeneous for trace elements within the observed precisions of 5 and 15% (mean), respectively. Detection limits were in the range 0.01 - 0.3 μg g−1 for elements of lower mass numbers (amu < 80) and 1 - 10 ng g−1 for heavy elements (amu > 80). Detection at the sub ng g−1 level is possible for most of the heavy elements by using an ablation pit size larger than 10 0 μm.  相似文献   

17.
We present a revised method for the determination of concentrations of rare earth (REE) and other trace elements (Y, Sc, Zr, Ba, Hf, Th) in geological samples. Our analytical procedure involves sample digestion using alkaline fusion (NaOH-Na2O2) after addition of a Tm spike, co-precipitation on iron hydroxides, and measurement by sector field-inductively coupled plasma-mass spectrometry (SF-ICP-MS). The procedure was tested successfully for various rock types (i.e., basalt, ultramafic rock, sediment, soil, granite), including rocks with low trace element abundances (sub ng g−1). Results obtained for a series of nine geological reference materials (BIR-1, BCR-2, UB-N, JP-1, AC-E, MA-N, MAG-1, GSMS-2, GSS-4) are in reasonable agreement with published working values.  相似文献   

18.
The platinum-group elements (PGE) and gold have been determined in twenty international rock reference materials by inductively coupled plasma-mass spectrometry (ICP-MS) after pre-concentration by a nickel sulfide fire assay. It was possible to achieve determination limits for a 50 g sample that ranged from 1 pg g-1 (Rh) to 23 pg g-1 (Au). Compared to published certified and recommended values for rock reference materials, the trueness of the method was found to be good. However, in some cases we observed large deviations for all elements in the sub 10 ng g-1 range within individual reference sample splits. Our results show that the PGE and Au are inhomogeneously distributed in the reference materials analysed here, where they are present in low concentrations, using 50 g test portions.  相似文献   

19.
The concentration of boron was determined in twenty one geochemical reference materials (silicate rocks) by isotope dilution inductively coupled plasma-mass spectrometry. Boron was extracted from the rocks using HF digestion, suppressing boron volatilisation through boron-mannitol complexation. Sample solutions, in a diluted HCl matrix, were analysed by ICP-MS without any separation of boron from the matrix elements. The results obtained were in agreement with the literature data and indicate that using the described procedure, trace amounts of boron can be very easily determined in complex matrices with rapidity and precision. With the instrumentation and reagents used in this study, this procedure can be used for the determination of 0.5 μg g−1 boron in a 15 0 mg silicate rock sample. Replicate analyses of the twenty one geochemical reference materials (GRM), ranging in boron concentration from 1.35 to 15 7 μg g−1, yielded precisions (relative standard deviation) varying between 0.9 and 9.8%.  相似文献   

20.
National Institute of Science and Technology (NIST) silicate glass SRM 610 is widely used as a certified reference material for various micro-analytical techniques such as SIMS or laser ablation ICP-MS. SRM 610 has been nominally doped with sixty one trace elements at the 500 μg g−1 level, but certified concentration data exist for only a few of these elements. This study reports concentration data for fifty nine trace elements obtained by ICP-MS, SSMS, LIMS, TIMS, INAA, AAS, and PIXE analyses of two different SRM 610 wafers. Most elements fall within a 10% band around a median value of about 440 μg g−1. The REE concentrations are shown to be constant to 3% (1 σ), thus emphasizing the value of SRM 610 as a reference material for REE analyses.
Comparison of our values with published data suggests that different SRM 610 wafers are, within errors, chemically identical for most elements. Exceptions to this general rule appear to be restricted to elements which were partly lost during the production of the glass, e.g. Ag and Br. On the basis of six independent determinations of Rb concentrations, which are systematically lower by a few percent than the reported NIST value, we argue that the certified Rb concentration may not be representative for all distributed SRM 610 wafers.  相似文献   