1.
A bridge health monitoring system is presented based on vibration measurements collected from a network of acceleration sensors. Sophisticated structural identification methods, combining information from the sensor network with the theoretical information built into a finite element model for simulating bridge behavior, are incorporated into the system in order to monitor structural condition, track structural changes and identify the location, type and extent of damage. This work starts with a brief overview of the modal and model identification algorithms and software incorporated into the monitoring system and then presents details on a Bayesian inference framework for the identification of the location and the severity of damage using measured modal characteristics. The methodology for damage detection combines the information contained in a set of measurement modal data with the information provided by a family of competitive, parameterized, finite element model classes simulating plausible damage scenarios in the structure. The effectiveness of the damage detection algorithm is demonstrated and validated using simulated modal data from an instrumented R/C bridge of the Egnatia Odos motorway, as well as using experimental vibration data from a laboratory small-scaled bridge section.  相似文献   

2.
This paper presents the application of system identification (SI) to long‐span cable‐supported bridges using seismic records. The SI method is based on the System Realization using Information Matrix (SRIM) that utilizes correlations between base motions and bridge accelerations to identify coefficient matrices of a state‐space model. Numerical simulations using a benchmark cable‐stayed bridge demonstrate the advantages of this method in dealing with multiple‐input multiple‐output (MIMO) data from relatively short seismic records. Important issues related to the effects of sensor arrangement, measurement noise, input inclusion, and the types of input with respect to identification results are also investigated. The method is applied to identify modal parameters of the Yokohama Bay Bridge, Rainbow Bridge, and Tsurumi Fairway Bridge using the records from the 2004 Chuetsu‐Niigata earthquake. Comparison of modal parameters with the results of ambient vibration tests, forced vibration tests, and analytical models are presented together with discussions regarding the effects of earthquake excitation amplitude on global and local structural modes. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

3.
Output‐only modal identification is needed when only structural responses are available. As a powerful unsupervised learning algorithm, blind source separation (BSS) technique is able to recover the hidden sources and the unknown mixing process using only the observed mixtures. This paper proposes a new time‐domain output‐only modal identification method based on a novel BSS learning algorithm, complexity pursuit (CP). The proposed concept—independent ‘physical systems’ living on the modal coordinates—connects the targeted constituent sources (and their mixing process) targeted by the CP learning rule and the modal responses (and the mode matrix), which can then be directly extracted by the CP algorithm from the measured free or ambient system responses. Numerical simulation results show that the CP method realizes accurate and robust modal identification even in the closely spaced mode and the highly damped mode cases subject to non‐stationary ambient excitation and provides excellent approximation to the non‐diagonalizable highly damped (complex) modes. Experimental and real‐world seismic‐excited structure examples are also presented to demonstrate its capability of blindly extracting modal information from system responses. The proposed CP is shown to yield clear physical interpretation in modal identification; it is computational efficient, user‐friendly, and automatic, requiring little expertise interactions for implementations. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
A procedure which involves a non‐linear eigenvalue problem and is based on the substructure method is proposed for the free‐vibration analysis of a soil–structure system. In this procedure, the structure is modelled by the standard finite element method, while the unbounded soil is modelled by the scaled boundary finite element method. The fundamental frequency, and the corresponding radiation damping ratio as well as the modal shape are obtained by using inverse iteration. The free vibration of a dam–foundation system, a hemispherical cavity and a hemispherical deposit are analysed in detail. The numerical results are compared with available results and are also verified by the Fourier transform of the impulsive response calculated in the time domain by the three‐dimensional soil–structure–wave interaction analysis procedure proposed in our previous paper. The fundamental frequency obtained by the present procedure is very close to that obtained by Touhei and Ohmachi, but the damping ratio and the imaginary part of modal shape are significantly different due to the different definition of damping ratio. This study shows that although the classical mode‐superposition method is not applicable to a soil–structure system due to the frequency dependence of the radiation damping, it is still of interest in earthquake engineering to evaluate the fundamental frequency and the corresponding radiation damping ratio of the soil–structure system. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

5.
Damage assessment of a structure involves acquiring and identifying dynamic characteristics of the structure and using these characteristics to evaluate behavior and performance. In this study, an unsymmetrical three‐story steel structure (fabricated with one weak column in the first floor) was tested on shaking table and subjected to a series of earthquake excitations with increasing level of excitation back to back. Besides, white noise excitation was also applied in between the earthquake excitation to serve as the reference state. Both the traditional sensing system (accelerometer and linear variable differential transformer) and the local optical tracker system were implemented in the structure to collect the vibration‐based responses. For operational modal analysis, structural response from white noise excitation will be used in this study. First, the traditional system identification using global response data is used (multivariate autoregressive (AR)‐model) to extract system natural frequencies and mode shapes from all different set of white noise responses after earthquake excitation. The migration of AR‐coefficient ellipse error from each sensor response was used to identify the damage location. Second, blind source separation technique was used to identify the modal contribution of the structure from each test, which provide information to detect the damage severity. Finally, from the local optical tracker array data, the principal component analysis was applied to quantify the earthquake‐induce local stress of the structural member. Combine the result from damage detection using global measurement and the identified local element stress, one can locate and quantify the damage. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
7.
This paper proposes bi‐directional coupled tuned mass dampers (BiCTMDs) for the seismic response control of two‐way asymmetric‐plan buildings subjected to bi‐directional ground motions. The proposed BiCTMD was developed from the three‐degree‐of‐freedom modal system, which represents the vibration mode of a two‐way asymmetric‐plan building. The performance of the proposed BiCTMD for the seismic response control of elastic two‐way asymmetric‐plan buildings was verified by investigating the reductions of the amplitudes of the associated frequency response functions. In addition, the investigation showed that the proposed BiCTMD is effective in reducing the seismic damage of inelastic asymmetric‐plan buildings. Therefore, the BiCTMD is an effective approach for the seismic response control of both elastic and inelastic two‐way asymmetric‐plan buildings. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
A method for parametric system identification of classically damped linear system in frequency domain is adopted and extended for non‐classically damped linear systems subjected up to six components of earthquake ground motions. This method is able to work in multi‐input/multi‐output (MIMO) case. The response of a two‐degree‐of‐freedom model with non‐classical damping, excited by one‐component earthquake ground motion, is simulated and used to verify the proposed system identification method in the single‐input/multi‐output case. Also, the records of a 10 storey real building during the Northridge earthquake is used to verify the proposed system identification method in the MIMO case. In this case, at first, a single‐input/multi‐output assumption is considered for the system and modal parameters are identified, then other components of earthquake ground motions are added, respectively, and the modal parameters are identified again. This procedure is repeated until all four components of earthquake ground motions which are measured at the base level of the building are included in the identification process. The results of identification of real building show that consideration of non‐classical damping and inclusion of the multi‐components effect of earthquake ground motions can improve the least‐squares match between the finite Fourier transforms of recorded and calculated acceleration responses. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

9.
Two approximate methods for decomposing complicated inelastic dynamic responses of wall buildings into simple modal responses are presented. Both methods are based on the equivalent linear concept, where a non‐linear structure is represented by a set of equivalent linear models. One linear model is used for representing only one vibration mode of the non‐linear structure, and its equivalent linear parameters are identified from the inelastic response time histories by using a numerical optimizer. Several theoretical relations essential for the modal decomposition are derived under the framework of complex modal analysis. Various numerical examinations have been carried out to check the validity of the proposed modal decomposition methods, and the results are quite satisfactory in all cases. Fluctuating bending moment and shear at any location along the wall height contributed by each individual vibration mode can be obtained. Modal contributions to shear and flexural strength demands, as well as the corresponding modal properties, under various seismic loading conditions can also be identified and examined in detail. Furthermore, the effects of higher vibration modes on seismic demands of wall buildings are investigated by using the modal decomposition methods. Several new insights into the complicated inelastic dynamics of multi‐story wall buildings are presented. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

10.
This briefing describes the first deployment of a new electronic tracer (E‐tracer) for obtaining along‐flowpath measurements in subsurface hydrological systems. These low‐cost, wireless sensor platforms were deployed into moulins on the Greenland Ice Sheet. After descending into the moulin, the tracers travelled through the subglacial drainage system before emerging at the glacier portal. They are capable of collecting along‐flowpath data from the point of injection until detection. The E‐tracers emit a radio frequency signal, which enables sensor identification, location and recovery from the proglacial plain. The second generation of prototype E‐tracers recorded water pressure, but the robust sensor design provides a versatile platform for measuring a range of parameters, including temperature and electrical conductivity, in hydrological environments that are challenging to monitor using tethered sensors. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
Optimal transducer placement for health monitoring of long span bridge   总被引:7,自引:0,他引:7  
In experimental modal testing, the measurement locations and the number of measurements have a major influence on the quality of the results. In general, there are several alternative schemes for sensor placement, and the accuracy of the data increases as the number of sensors utilized increases. However, the number of transducers that can be attached to a real structure is limited by economic constraints. Therefore, algorithms that address the issue of limited instrumentation and its effects on resolution and accuracy are important from the standpoint of experimental modal analysis. The authors are particularly interested in structural dynamics based damage evaluation of large structures, and the development and implementation of suitable sensor location algorithms are critical for such a problem. A kinetic energy optimization technique (EOT) has been derived, and numerical issues are addressed and applied to real experimental data obtained from a model of an asymmetric long span bridge. Using experimental data from the bridge model, the algorithm proposed in this paper is compared to Kammer's EIM algorithm, which optimizes the transducer placement for identification and control purposes.  相似文献   

12.
Partial‐strength composite steel–concrete moment‐resisting (MR) frame structures represent an open research field in seismic design from both a theoretical and an experimental standpoint. Among experimental techniques, vibration testing is a well‐known and powerful technique for damage detection, localization and quantification, where actual modal parameters of a structure at different states can be determined from test data by using system identification methods. However, the identification of semi‐rigid connections in framed structures is limited, and hence this paper focuses on a series of vibration experiments that were carried out on a realistic MR frame structure, following the application of pseudo‐dynamic and quasi‐static cyclic loadings at the European laboratory for structural assessment of the Joint Research Centre at Ispra, Italy, with the scope of understanding the structural behaviour and identifying changes in the dynamic response. From the forced vibration response, natural frequencies, damping ratios, modal displacements and rotations were extracted using the circle fitting technique. These modal parameters were used for local and global damage identification by updating a 3D finite element model of the intact structure. The identified results were then correlated with observations performed on the structure to understand further the underlying damage mechanisms. Finally, the latin hypercube sampling technique, a variant of the Monte Carlo method, was employed in order to study the sensitivity of the updated parameters of the 3D model to noise on the modal inputs. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A procedure is presented to determine new modal combination rules (both CQC and SRSS) for non‐classically damped structures. The procedure presented in this paper does not need the solution of any complex eigenvalue problem, in contrast to other methods found in the literature. Thus, the modal combination rules presented here are easily applicable, even by those engineers who are unaccustomed to using complex algebra. Moreover, these formulations show the further advantage of requiring the response spectra only for the target damping ratio value. So the use of approximated formulae, necessary for passing from the response spectrum with the target damping ratio value to other ones, is avoided. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

14.
Unlike conventional sensors that measure the passage of seismic waves at a single position, distributed vibration sensing systems, also known as distributed acoustic sensing systems, detect the passage of seismic waves by averaging a measurement of strain over a section of fibre‐optic cable. Distributed vibration sensing systems work by transmitting pulses of light down the fibre and measuring the phase of the Rayleigh backscatter. At random positions along the fibre, however, fading occurs; this is where the amplitude of the backscattered signal is very small due to cancellation of the scattered electric fields, resulting in anomalously noisy traces in a common source gather. This paper addresses the problem of fading in a particular form of distributed vibration sensors: a new optical arrangement of the instrumentation is described that allows the measurement to be carried out quasi‐simultaneously at multiple optical interrogation frequencies. The interrogation frequencies are chosen to be sufficiently different that their fading properties are distinct and the diversity thus obtained is used to aggregate the data obtained to substantially reduce the noise caused by fading. As well as reducing the effects of fading, the aggregation of the independent results can also help to reduce the overall noise of the measurement and improve the linearity of the distributed vibration sensing system.  相似文献   

15.
This paper discusses the dynamic tests, system identification, and modeling of a 10‐story reinforced concrete building. Six infill walls were demolished in 3 stages during the tests to introduce damage. In each damage stage, dynamic tests were conducted by using an eccentric‐mass shaker. Accelerometers were installed to record the torsional and translational responses of the building to the induced excitation, as well as its ambient vibration. The modal properties in all damage states are identified using 2 operational modal analysis methods that can capture the effect of the wall demolition. The modal identification is facilitated by a finite element model of the building. In turn, the model is validated through the comparison of the numerically and experimentally obtained modal parameters. The validated model is used in a parametric study to estimate the influence of structural and nonstructural elements on the dynamic properties of the building and to assess the validity of commonly used empirical formulas found in building codes. Issues related to the applicability and feasibility of system identification on complex structures, as well as considerations for the development of accurate, yet efficient, finite element models are also discussed.  相似文献   

16.
Based on the Hilbert–Huang spectral analysis, a method is proposed to identify multi‐degree‐of‐freedom (MDOF) linear systems using measured free vibration time histories. For MDOF systems, the normal modes have been assumed to exist. In this method, the measured response data, which are polluted by noises, are first decomposed into modal responses using the empirical mode decomposition (EMD) approach with intermittency criteria. Then, the Hilbert transform is applied to each modal response to obtain the instantaneous amplitude and phase angle time histories. A linear least‐square fit procedure is proposed to identify the natural frequency and damping ratio from the instantaneous amplitude and phase angle for each modal response. Based on a single measurement of the free vibration time history at one appropriate location, natural frequencies and damping ratios can be identified. When the responses at all degrees of freedom are measured, the mode shapes and the physical mass, damping and stiffness matrices of the structure can be determined. The applications of the proposed method are illustrated using three linear systems with different dynamic characteristics. Numerical simulation results demonstrate that the proposed system identification method yields quite accurate results, and it offers a new and effective tool for the system identification of linear structures in which normal modes exist. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

17.
Accurate prediction of the dynamic responses of a high-rise building subjected to dynamic loads such as earthquake and wind excitations requires the information of its structural dynamic properties such as modal parameters including natural frequencies and damping ratios. This paper presents the identification results of the modal parameters based on field vibration tests on a 600-m high skyscraper. A set of tests, including ambient vibration test (AVT) and free vibration test (FVT), were conducted on the skyscraper to identify its modal parameters. Firstly, this paper presents and discusses the modal parameters of the skyscraper assessed by several identification methods applied to the AVT measurements. These methods include the wavelet transform (WT) method, the stochastic subspace identification (SSI) method, and the random decrement technique (RDT). Secondly, an active mass damper (AMD) system with total mass 1000 tons equipped into the skyscraper was used to excite the building for estimation of the modal parameters by FVT. Thirdly, this paper presents observations on the structural dynamic behavior of the skyscraper with the operation of the AMD system during a typhoon event. The field measurement results show that the AMD system functioned efficiently for suppression of the wind-induced vibrations of the skyscraper during the typhoon. This paper aims to further understand the structural dynamic properties of super-tall buildings and provide useful information for structural design and vibration control of future skyscrapers.  相似文献   

18.
In this paper, a criterion is proposed for the choice of the optimal location of a limited number of recording sensors for reconstruction of seismic responses of multistorey frames. Reconstruction of unknown responses is performed by modelling through a spline shape function the evolution of the relative acceleration along the height of the building. The coefficients of the spline function are determined by interpolating available responses in terms of absolute accelerations taking into account boundary conditions. The optimal location for a given number of recording sensors is defined as the one corresponding to the minimum value of the global error evaluated on the whole set of reconstructed responses. The criterion has been verified by using simulated responses of numerical models of multistorey frames and responses recorded on real buildings during the Northridge earthquake. A physical characterization of the location of available sensors leading to the minimum global error between calculated and real responses is proposed in terms of effective modal participation factors relevant to the principal modes of the structure. This characterization allows for frames of known modal characteristics the definition of a criterion for the choice of the location of a limited number of sensors for monitoring or vibration control purposes. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

19.
A novel smart control system based on genetic algorithms (GAs) is proposed in this paper. The system is comprised of three parts: the fiber Bragg grating (FBG) sensor‐based sensing network for structural health monitoring, the GA‐based location optimizer for sensor arrangement, and the GA‐based controller for vibration mitigation under external excitation. To evaluate the performance of the proposed system, an eight‐story steel structure was designed specifically to represent a structure with large degrees of freedom. In total 16 FBG sensors were deployed on the structure to implement the concept of a reliable sensing network, and to allow the structure to be monitored precisely under any loading. The advantage of applying a large amount of information from the sensing system is proven theoretically by the GA‐based location optimizer. This result greatly supports the recent tendency of distributing sensors around the structure. Two intuitive GA‐based controllers are then proposed and demonstrated numerically. It is shown that the structure can be controlled more effectively by the proposed GA‐strain controller than by the GA‐acceleration controller, which represents the traditional control method. A shaking table test was carried out to examine the entire system. Experimental verification has demonstrated the feasibility of using this system in practice. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
This paper verifies the feasibility of the proposed system identification methods by utilizing shaking table tests of a full‐scale four‐story steel building at E‐Defense in Japan. The natural frequencies, damping ratios and modal shapes are evaluated by single‐input‐four‐output ARX models. These modal parameters are prepared to identify the mass, damping and stiffness matrices when the objective structure is modelled as a four degrees of freedom (4DOF) linear shear building in each horizontal direction. The nonlinearity in stiffness is expressed as a Bouc–Wen hysteretic system when it is modelled as a 4DOF nonlinear shear building. The identified hysteretic curves of all stories are compared to the corresponding experimental results. The simple damage detection is implemented using single‐input‐single‐output ARX models, which require only two measurements in each horizontal direction. The modal parameters are equivalent‐linearly evaluated by the recursive Least Squares Method with a forgetting factor. When the structure is damaged, its natural frequencies decrease, and the corresponding damping ratios increase. The fluctuation of the identified modal properties is the indirect information for damage detection of the structure. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   