1.
This paper aims to extend the consecutive modal pushover (CMP) procedure for estimating the seismic demands of two-way unsymmetric-plan tall buildings subjected to bi-directional seismic ground motions taking the effects of higher modes and torsion into account. Multi-stage and single-stage pushover analyses are carried out in both X and Y directions. Inelastic seismic responses obtained by multi-stage and single-stage pushover analyses for X and Y directions are combined using the SRSS combination scheme. The final seismic responses are determined by enveloping the combined results of multi-stage and single-stage pushover analyses. To evaluate the accuracy of the proposed procedure, it is applied to two-way unsymmetric-plan tall buildings which include torsionally stiff and torsionally flexible systems. The results derived from the CMP procedure are compared with those from nonlinear response history analysis (NL-RHA), as a benchmark solution. Moreover, the advantages of the proposed procedure are demonstrated by comparing the results derived from the CMP to those from pushover analysis with uniform and fundamental effective mode distributions. The proposed procedure is able to accurately predict amplification or de-amplification of the seismic displacements at the flexible and stiff edges of the two-way unsymmetric-plan tall buildings by considering the effects of higher modes and torsion. The extended CMP procedure can accurately estimate the peak inelastic responses, such as displacements and storey drifts. The CMP procedure features a higher potential in estimating plastic hinge rotations at both flexible and stiff sides of unsymmetric-plan tall buildings under bi-directional seismic excitation when compared to the uniform and fundamental effective mode force distributions.  相似文献   

2.
An envelope‐based pushover analysis procedure is presented that assumes that the seismic demand for each response parameter is controlled by a predominant system failure mode that may vary according to the ground motion. To be able to simulate the most important system failure modes, several pushover analyses need to be performed, as in a modal pushover analysis procedure, whereas the total seismic demand is determined by enveloping the results associated with each pushover analysis. The demand for the most common system failure mode resulting from the ‘first‐mode’ pushover analysis is obtained by response history analysis for the equivalent ‘modal‐based’ SDOF model, whereas demand for other failure modes is based on the ‘failure‐based’ SDOF models. This makes the envelope‐based pushover analysis procedure equivalent to the N2 method provided that it involves only ‘first‐mode’ pushover analysis and response history analysis of the corresponding ‘modal‐based’ SDOF model. It is shown that the accuracy of the approximate 16th, 50th and 84th percentile response expressed in terms of IDA curves does not decrease with the height of the building or with the intensity of ground motion. This is because the estimates of the roof displacement and the maximum storey drift due to individual ground motions were predicted with a sufficient degree of accuracy for almost all the ground motions from the analysed sets. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
Performance based design becomes an effective method for estimating seismic demands of buildings. In asymmetric plan tall building the effects of higher modes and torsion are crucial. The consecutive modal pushover (CMP) procedure is one of the procedures that consider these effects. Also in previous studies the influence of soil-structure interaction (SSI) in pushover analysis is ignored. In this paper the CMP procedure is modified for one-way asymmetric plan mid and high-rise buildings considering SSI. The extended CMP (ECMP) procedure is proposed in order to overcome some limitations of the CMP procedure. In this regard, 10, 15 and 20 story buildings with asymmetric plan are studied considering SSI assuming three different soil conditions. Using nonlinear response history analysis under a set of bidirectional ground motion; the exact responses of these buildings are calculated. Then the ECMP procedure is evaluated by comparing the results of this procedure with nonlinear time history results as an exact solution as well as the modal pushover analysis procedure and FEMA 356 load patterns. The results demonstrate the accuracy of the ECMP procedure.  相似文献   

4.
An approximation approach of seismic analysis of two‐way asymmetric building systems under bi‐directional seismic ground motions is proposed. The procedures of uncoupled modal response history analysis (UMRHA) are extended to two‐way asymmetric buildings simultaneously excited by two horizontal components of ground motion. Constructing the relationships of two‐way base shears versus two‐way roof translations and base torque versus roof rotation in ADRS format for a two‐way asymmetric building, each modal pushover curve bifurcates into three curves in an inelastic state. A three‐degree‐of‐freedom (3DOF) modal stick is developed to simulate the modal pushover curve with the stated bifurcating characteristic. It requires the calculation of the synthetic earthquake and angle β. It is confirmed that the 3DOF modal stick is consistent with single‐degree‐of‐freedom modal stick in an elastic state. A two‐way asymmetric three‐story building was analyzed by UMRHA procedure incorporating the proposed 3DOF modal sticks. The analytical results are compared with those obtained from nonlinear response history analysis. It is shown that the 3DOF modal sticks are more rational and effective in dealing with the assessment of two‐way asymmetric building systems under two‐directional seismic ground motions. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

5.
A simplified procedure is proposed to predict the largest peak seismic response of an asymmetric building to horizontal bi-directional ground motion, acting at an arbitrary angle of incidence. The main characteristics of the proposed procedure is as follows. (1) The properties of two independent equivalent single-degree-of-freedom models are determined according to the principal direction of the first modal response in each nonlinear stage, rather than according to the fixed axis based on the mode shape in the elastic stage; the principal direction of the first modal response in each nonlinear stage is determined based on pushover analysis results. (2) The bi-directional horizontal seismic input is simulated as identical spectra of the two horizontal components, and the contribution of each modal response is directly estimated based on the unidirectional response in the principal direction of each. (3) The drift demand at each frame is determined based on four pushover analyses considering the combination of bi-directional excitations. In the numerical example, nonlinear time-history analyses of six four-story torsionally stiff (TS) asymmetric buildings are carried out considering various directions of seismic inputs, and these results are compared with the predicted results. The results show that the proposed procedure satisfactorily predicts the largest peak response displacement at the flexible-side frame of a TS asymmetric building.  相似文献   

6.
A pushover procedure with a load pattern based on the height-wise distribution of the combined modal story shear and torsional moment is proposed to estimate the seismic response of 3D asymmetric-plan building frames. Contribution of the higher modes and torsional response of asymmetric-plan buildings are incorporated into the proposed load pattern. The proposed pushover method is a single-run procedure, which enables tracing the nonlinear response of the structure during the analysis and averts the elusiveness of conducting multiple pushover analyses. The proposed method has been used to estimate the response of two moment-resisting building frames with 9 and 20 stories. The obtained results indicate the appropriate accuracy and efficiency of the proposed procedure in estimating the trend of the drift profiles of the structures resulted from nonlinear time history analyses.  相似文献   

7.
An Erratum has been published for this article in Earthquake Engng. Struct. Dyn. 2004; 33:1429. Based on structural dynamics theory, the modal pushover analysis (MPA) procedure retains the conceptual simplicity of current procedures with invariant force distribution, now common in structural engineering practice. The MPA procedure for estimating seismic demands is extended to unsymmetric‐plan buildings. In the MPA procedure, the seismic demand due to individual terms in the modal expansion of the effective earthquake forces is determined by non‐linear static analysis using the inertia force distribution for each mode, which for unsymmetric buildings includes two lateral forces and torque at each floor level. These ‘modal’ demands due to the first few terms of the modal expansion are then combined by the CQC rule to obtain an estimate of the total seismic demand for inelastic systems. When applied to elastic systems, the MPA procedure is equivalent to standard response spectrum analysis (RSA). The MPA estimates of seismic demand for torsionally‐stiff and torsionally‐flexible unsymmetric systems are shown to be similarly accurate as they are for the symmetric building; however, the results deteriorate for a torsionally‐similarly‐stiff unsymmetric‐plan system and the ground motion considered because (a) elastic modes are strongly coupled, and (b) roof displacement is underestimated by the CQC modal combination rule (which would also limit accuracy of RSA for linearly elastic systems). Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

8.
The modal pushover analysis (MPA) procedure, presently restricted to one horizontal component of ground motion, is extended to three‐dimensional analysis of buildings—symmetric or unsymmetric in plan—subjected to two horizontal components of ground motion, simultaneously. Also presented is a variant of this method, called the practical modal pushover analysis (PMPA) procedure, which estimates seismic demands directly from the earthquake response (or design) spectrum. Its accuracy in estimating seismic demands for very tall buildings is evaluated, demonstrating that for nonlinear systems this procedure is almost as accurate as the response spectrum analysis procedure is for linear systems. Thus, for practical applications, the PMPA procedure offers an attractive alternative whereby seismic demands can be estimated directly from the (elastic) design spectrum, thus avoiding the complications of selecting and scaling ground motions for nonlinear response history analysis. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
The effects of higher modes and torsion have a significant impact on the seismic responses of asymmetric-plan tall buildings.A consecutive modal pushover(CMP) procedure is one of the pushover methods that have been developed to consider these effects.The aim of this paper is to modify the(CMP) analysis procedure to estimate the seismic demands of one-way asymmetric-plan tall buildings with dual systems.An analysis of 10-,15-and 20-story asymmetric-plan buildings is carried out,and the results from the modified consecutive modal pushover(MCMP) procedure are compared with those obtained from the modal pushover analysis(MPA) procedure and the nonlinear time history analysis(NLTHA).The MCMP estimates of the seismic demands of one-way asymmetric-plan buildings demonstrate a reasonable accuracy,compared to the results obtained from the NLTHA.Furthermore,the accuracy of the MCMP procedure in the prediction of plastic hinge rotations is better than the MPA procedure.The new pushover procedure is also more accurate than the FEMA load distribution and the MPA procedure.  相似文献   

10.
This paper investigates the seismic response of tall cantilever wall buildings subjected to pulse type ground motion, with special focus on the relation between the characteristics of ground motion and the higher‐modes of response. Buildings 10, 20, and 40 stories high were designed such that inelastic deformation was concentrated at a single flexural plastic hinge at their base. Using nonlinear response history analysis, the buildings were subjected to near‐fault seismic ground motions and simple closed‐form pulses, which represented distinct pulses within the ground motions. Euler–Bernoulli beam models with lumped mass and lumped plasticity were used to model the buildings. The response of the buildings to the closed‐form pulses fairly matched that of the near‐fault records. Subsequently, a parametric study was conducted for the buildings subjected to three types of closed‐form pulses with a broad range of periods and amplitudes. The results of the parametric study demonstrate the importance of the ratio of the fundamental period of the structure to the period of the pulse to the excitation of higher modes. The study shows that if the modal response spectrum analysis approach is used — considering the first four modes with a uniform yield reduction factor for all modes, and with the square root of sum of squares modal combination rule — it significantly underestimates bending moment and shear force responses. A response spectrum analysis method that uses different yield reduction factors for the first and the higher modes is presented. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
For modal pushover analysis procedures, the model proposed by Ghobarah et al. (called the G model hereafter, 1999) has been extended to account for the contributions of transient higher modes to global seismic damage of structures excited by strong ground motions. The proposed model has physically and perfectly bridged the G model and the final softening model proposed by DiPasquale and Cakmak (1988). Modal damage indexes corresponding to all considered vibration modes are combined by the CQC rule or the SRSS rule. Incremental dynamic analysis (IDA) is performed on three example RC frames to validate the proposed model, and a comprehensive comparison is carried out. The demonstration indicates that the proposed model is easy to implement and reflects the influence of the transition in transient vibration periods and modes on structural damage evolution. Some limitations associated with the proposed model are also addressed. Further experimental validations are needed to improve the model in the future.  相似文献   

12.
An accurate estimation of the applied load pattern is an essential component in each pushover procedure. Recently, a number of adaptive pushover methods have been proposed in which the effects of the higher modes as well as the progressive changes in the dynamic characteristics of structures are taken into account to compute the applied load pattern. The basic shortcoming of these advanced pushover methods is related to employing the quadratic modal combination rule, whereby the sign reversals of the modal load vectors are suppressed. In this study, an improved displacement-based adaptive pushover method is developed in which the applied load pattern is computed using the factor modal combination rule(FMC). In the proposed procedure, multiple load patterns, depending on the number of the modes considered, are determined in order to take into account the sign reversals of different modal load vectors. The accuracy of the proposed method is verifi ed for seven moment resisting frame buildings of 3, 9 and 20 stories with regularity or vertically geometric and mass irregularities subjected to 60 earthquake ground motion records. The results showed that the proposed methodology is capable of reproducing the peak dynamic responses with very good accuracy.  相似文献   

13.
The extended N2 method taking into account higher mode effects in elevation   总被引:1,自引:0,他引:1  
The N2 method has been extended in order to take into account higher mode effects in elevation. The extension is based on the assumption that the structure remains in the elastic range when vibrating in higher modes. The seismic demand in terms of displacements and storey drifts can be obtained by enveloping the results of basic pushover analysis and the results of standard elastic modal analysis. The approach is consistent with the extended N2 method used for plan‐asymmetric buildings. The proposed procedure was applied to three variants of three steel frame buildings used in the SAC project. The structural response was investigated for two sets of ground motions. Different ground motion intensities were used in order to investigate the influence of the magnitude of plastic deformations. The N2 results were compared with the results of nonlinear response‐history analysis, two other pushover‐based methods (modal pushover analysis (MPA) and modified MPA (MMPA)), and pushover analysis without consideration of higher modes. It was found that a considerable influence of higher modes on storey drifts is present at the upper part of medium‐and high‐rise structures. This effect is the largest in the case of elastic behaviour and decreases with ground motion intensity. The higher mode effects also depend on the spectral shape. The approximate methods (extended N2, MPA and MMPA) are able to provide fair estimates of response in the case of the test examples. Accuracy decreases with the height of the building, and with the intensity of ground motion. The N2 results are generally conservative. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
The accuracy of the three‐dimensional modal pushover analysis (MPA) procedure in estimating seismic demands for unsymmetric‐plan buildings due to two horizontal components of ground motion, simultaneously, is evaluated. Eight low‐and medium‐rise structures were considered. Four intended to represent older buildings were designed according to the 1985 Uniform Building Code, whereas four other designs intended to represent newer buildings were based on the 2006 International Building Code. The median seismic demands for these buildings to 39 two‐component ground motions, scaled to two intensity levels, were computed by MPA and nonlinear response history analysis (RHA), and then compared. Even for these ground motions that deform the buildings significantly into the inelastic range, MPA offers sufficient degree of accuracy. It is demonstrated that PMPA, a variant of the MPA procedure, for nonlinear systems is almost as accurate as the well‐known standard response spectrum analysis procedure is for linear systems. Thus, for practical applications, the PMPA procedure offers an attractive alternative to nonlinear RHA, whereby seismic demands can be estimated directly from the (elastic) design spectrum. In contrast, the nonlinear static procedure specified in the ASCE/SEI 41‐06 Standard is demonstrated to grossly underestimate seismic demands for some of the unsymmetric‐plan buildings considered. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
结构Pushover分析的侧向力分布及高阶振型影响   总被引:52,自引:8,他引:44  
Pushover分析方法是逐渐得到广泛应用的一种评估结构抗震性能的简化方法,已被引入我国新的建筑结构抗震设计规范。侧向力分布的选取是结构Pushover分析中的一个关键问题,尤其高阶振型影响显著时其选取直接影响Pushover分析的结果。本文通过拟合规范反应谱,挑选了适用Ⅱ类场地的4条地震动记录和4条人工波,对比了典型地震动下非线性时程分析和采用5种不同侧向力分布的Pushover分析的5层、10层和15层钢筋混凝土结构在不同地震动强度时的反应。通过结构振型参与系数量化了各个结构的高阶振型的影响。研究发现,随着结构层数的增加和地震动强度的增加高阶振型的影响变大,侧向力的选取变得十分重要。本文对在高阶振型影响下钢筋混凝土框架结构的Pushover分析中侧向力的选取提出了建议。  相似文献   

16.
本文主要研究如何通过合理设计来提高高层钢结构的整体抗震能力。首先,给出了高层钢结构的非线性计算模型;其次,建立了高层钢结构在强地震动作用下的倒塌失效模式的极限状态判别准则;然后,通过模态pushover分析,研究了高层钢结构在水平地震作用下的损伤规律;最后,重点研究了高层钢结构的整体抗震能力的提高方法,提出了均匀损伤的设计方法,该方法通过消除结构的薄弱层,来达到提高高层钢结构的整体抗震能力的目的。通过对两栋20层的高层钢框架结构进行极限时程分析和极限pushover分析,验证了文中提出的均匀损伤的设计方法的可行性。本文的工作可为高层钢结构的抗地震倒塌设计提供参考依据。  相似文献   

17.
In this paper a recently developed multimode pushover procedure for the approximate estimation of structural performance of asymmetric in plan buildings under biaxial seismic excitation is evaluated. Its main idea is that the seismic response of an asymmetric multi-degree-of-freedom system with \(N\) degrees of freedom under biaxial excitation can be related to the responses of \(N\) ‘modal’ equivalent single-degree-of-freedom (E-SDOF) systems under uniaxial excitation. The steps of the proposed methodology are quite similar to those of the well-known modal pushover analysis. However, the establishment of the (E-SDOF) systems is based on a new concept, in order to take into account multidirectional seismic effects. The proposed methodology does not require independent analysis in the two orthogonal directions and therefore the application of simplified superposition rules for the combination of seismic component effects is avoided. After a brief outline of the theoretical background and the application process, an extensive evaluation study is presented, which shows that, in general, the proposed methodology provides a reasonable estimation for the vast majority of the calculated response parameters.  相似文献   

18.
The pushover analysis (POA) procedure is difficult to apply to high-rise buildings, as it cannot account for the contributions of higher modes. To overcome this limitation, a modal pushover analysis (MPA) procedure was proposed by Chopra et al. (2001). However, invariable lateral force distributions are still adopted in the MPA. In this paper, an improved MPA procedure is presented to estimate the seismic demands of structures, considering the redistribution of inertia forces after the structure yields. This improved procedure is verified with numerical examples of 5-, 9- and 22-story buildings. It is concluded that the improved MPA procedure is more accurate than either the POA procedure or MPA procedure. In addition, the proposed procedure avoids a large computational effort by adopting a two-phase lateral force distribution..  相似文献   

19.
In this study a new method for nonlinear static analysis based on the relative displacements of stories is proposed that is able to be implemented in a single stage analysis and considers the effects of an arbitrary number of higher modes. The method is called the extended drift pushover analysis procedure (EDPA). To define the lateral load pattern, values of the relative displacements of stories are calculated using the elastic modal analysis and the modal combination factors introduced. For determining the combination factors, six different approaches are examined. Buildings evaluated in this study consist of four special steel moment-resisting frames with 10–30 stories. Responses including relative displacements of stories, story shear forces and rotation of plastic hinges in each story are calculated using the proposed approaches in addition to modal pushover analysis and nonlinear dynamic time history analyses. The nonlinear dynamic analysis is implemented using ten consistent earthquake records that have been scaled with regard to ASCE7-10. Distribution of response errors of story shears and plastic hinge rotations show that a major part of error corresponds to the second half of the buildings studied. Thus, the mentioned responses are corrected systematically. The final results of this study show that implementing the EDPA procedure using the third approach of this research is able to effectively overcome the limitations of both the traditional and the modal pushover analyses methods and predict the seismic demands of tall buildings with good accuracy.  相似文献   

20.
Nonlinear static (pushover) analysis has become a popular tool during the last decade for the seismic assessment of buildings. Nevertheless, its main advantage of lower computational cost compared to nonlinear dynamic time‐history analysis (THA) is counter‐balanced by its inherent restriction to structures wherein the fundamental mode dominates the response. Extension of the pushover approach to consider higher modes effects has attracted attention, but such work has hitherto focused mainly on buildings, while corresponding work on bridges has been very limited. Hence, the aim of this study is to adapt the modal pushover analysis procedure for the assessment of bridges, and investigate its applicability in the case of an existing, long and curved, bridge, designed according to current seismic codes; this bridge is assessed using three nonlinear static analysis methods, as well as THA. Comparative evaluation of the calculated response of the bridge illustrates the applicability and potential of the modal pushover method for bridges, and quantifies its relative accuracy compared to that obtained through other inelastic methods. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   