首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The out‐of‐plane response of walls in existing stone masonry buildings is one of the major causes of vulnerability commonly observed in post‐earthquake damage surveys. In this context, a shaking table (ST) test campaign was carried out on a full‐scale masonry façade mainly focusing on the characterization of its out‐of‐plane overturning behaviour. The structure tested on the ST is a partial reproduction of an existing building from Azores, damaged during the 9 July 1998 Faial earthquake. The definition of the tested specimen as well as the selection of the input ground motion is reported in this paper. A specific emphasis is given to the definition of the time‐history to be applied during the tests because it was felt as an essential and crucial part of the work to obtain the desired overturning behaviour. The accelerogram to be imposed was selected from a large set of accelerograms (74) by means of a step‐by‐step procedure on the basis of several numerical analyses resorting to the rocking response of rigid blocks. A companion paper (Part 2) focuses on the ST test results and detailed data interpretation. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
3.
The definition of adequate simplified models to assess the in‐plane load‐bearing capacity of masonry piers, in terms of both strength and displacement, plays a fundamental role in the seismic verification of masonry buildings. In this paper, a critical review of the most widespread strength criteria present in the literature and codes to interpret the failure modes of piers (rocking, crushing, bed joint sliding or diagonal cracking) are proposed. Models are usually based on an approximate evaluation of the stress state produced by the external forces in a few points/sections and on its assessment with reference to a limit strength domain. The aim of the review is to assess their reliability by discussing the hypotheses, which they are based on (assumed stress states; choice of reference points/sections on which to assess the pier strength; characteristics of the limit strength domain) and to verify the conditions for their proper use in practice, in terms of both stress fields (depending on the geometry of the pier, boundary conditions and applied loads) and types of masonry (i.e. regular brick masonry vs rubble stone masonry). In order to achieve these objectives, parametric nonlinear finite element analyses are performed and different experimental data available in the literature are analysed and compared. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

4.
The role of masonry infills in the seismic behavior of reinforced concrete buildings has been widely studied in terms of their strength and stiffness contribution in the in‐plane (IP) direction, while fewer studies have been carried out on their response and modeling in the out‐of‐plane (OOP) direction. In this paper, the state of the art in code and literature provisions regarding infills' OOP capacity and seismic demand is presented, together with a review of the experimental tests that have been carried out to investigate infills' OOP behavior and the effects of IP‐OOP interaction. This review aims to collect an experimental database that is used to evaluate the effectiveness of literature and code provisions and to propose a semiempirical approach both for predicting infills' OOP strength, stiffness, and displacement capacity and for modeling the effects of IP displacement demand on OOP behavior and vice versa. Then, the state of the art on modeling of infills' OOP behavior and IP‐OOP interaction is presented together with a new macro model based on the proposed formulations and conceived to represent the IP and OOP behavior by taking into account the mutual interaction effects. Finally, the proposed model is used for an example application on two case‐study buildings, showing the effects of taking into account or neglecting the IP‐OOP interaction phenomena.  相似文献   

5.
The present work reports on an in situ experimental test campaign carried out on abandoned traditional masonry houses after the 9th July 1998 earthquake that seriously hit the Faial island of Azores. For the testing purposes, an experimental test setup was developed based on a self‐equilibrated scheme, which is herein described reporting on the advantages and drawbacks of this in situ test setup. Five specimens were tested aiming at characterizing the out‐of‐plane behavior of stone masonry walls and strengthening solutions recommended for post‐earthquake interventions. A detailed comparison between solutions' efficiency is presented including a cost vs benefit analysis. In order to assess the efficiency of the developed test setup for other applications on stone masonry walls, an in‐plane test on an existing URM panel is also presented. Several related issues are discussed, namely the advantages of dealing with the real boundary conditions and the capacity of providing valuable information of the response, as well as a detailed analysis of the obtained results. The authors believe that this work provides an increase in knowledge on the seismic behavior of the existing masonry constructions, resulting from the development of an in situ test setup and the efficiency quantification of strengthening solutions. Therefore, the work is thought to positively contribute for the preservation of architectural heritage and for its seismic vulnerability reduction. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
The evaluation of the dynamic behaviour of rocking elements is directly correlated to the energy dissipated because of the impacts at the base interface, which can be represented by means of a coefficient of restitution. This schematization is commonly accepted as representative of the out‐of‐plane response of stone masonry walls. An experimental campaign (in a lab environment) aiming at assessing the value of this coefficient for a sacco granite masonry wall is presented in this work. The rocking motion at a predefined bed joint level was induced in the tested specimens in order to validate a novel test setup designed to assess the coefficient of restitution value by means of a realistic reproduction of the rocking behaviour of a single element, under the hypothesis of an infinitely stiff system above the bed joint level. As the main objective of the work was to assess the rocking behaviour of a masonry wall that looses energy at the impacts at a certain joint level, the flexural behaviour was not desirable and had to be avoided. For this purpose, a test setup based on the equivalent block approach was developed. In the final section of this work, comparisons between experimental and numerical results are presented together with some preliminary conclusions on the appropriate modelling strategy and the values of the coefficient of restitution to be used for the seismic assessment of the out‐of‐plane rocking behaviour of this type of sacco stone masonry walls. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
Two models of masonry infilled reinforced concrete frame buildings were tested at the shaking table. Models were built in the reduced scale 1:4 using the materials produced in accordance to modelling demands of true replica modelling technique. The first model represented a one‐storey box‐like building and the second one the two‐stories building with plan shaped in the form of a letter H. Models were shaken with the series of horizontal sine dwell motions with gradually increasing amplitude. Masonry infills of tested models were constructed of relatively strong bricks laid in weak mortar. Therefore, typical cracks developed and propagated along mortar beds without cracking of bricks or crushing of infill corners. Data collected from tests will be used in future evaluation, verification and development of computational models for prediction of in‐plane and out‐of‐plane behaviour of masonry infills. The responses of tested models can be well compared with global behaviour of real structures using the modelling rules. The similarity of local behaviour of structural elements, e.g. reinforced concrete joints, is less reliable due to limitations in modelling of steel reinforcement properties. The model responses showed that buildings designed according to Eurocodes are able to sustain relatively high dynamic excitations due to a significant level of structural overstrength. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

8.
This study focuses on the seismic safety evaluation of masonry buildings in Turkey for in‐plane failure modes using fragility curves. Masonry buildings are classified and a set of fragility curves are generated for each class. The major structural parameters in the classification of masonry buildings are considered as the number of stories, load‐bearing wall material, regularity in plan and the arrangement of walls (required length, openings in walls, etc.), in accordance with the observations from previous earthquakes and field databases. The fragility curves are generated by using time history (for demand) and pushover (for capacity) analyses. From the generated sets of fragility curves, it is observed that the damage state probabilities are significantly influenced from the number of stories and wall material strength. In the second stage of the study, the generated fragility curves are employed to estimate the damage of masonry buildings in Dinar after the 1995 earthquake. The estimated damage by fragility information is compared with the inspected visual damage as assessed from the Damage Evaluation Form. For the quantification of fragility‐based damage, a single‐valued index, named as ‘vulnerability score’ (VS), is proposed. There seems to be a fair agreement between the two damage measures. In addition to this, decisions regarding the repair or demolition of masonry buildings in Dinar due to visual damage inspection are on comparable grounds with the relative measure obtained from VS of the same buildings. Hence, the fragility‐based procedure can provide an alternative for the seismic safety evaluation of masonry buildings in Turkey. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

9.
This paper presents a detailed study on feasibility of un‐bonded fiber reinforced elastomeric isolator (U‐FREI) as an alternative to steel reinforced elastomeric isolator (SREI) for seismic isolation of un‐reinforced masonry buildings. Un‐reinforced masonry buildings are inherently vulnerable under seismic excitation, and U‐FREIs are used for seismic isolation of such buildings in the present study. Shake table testing of a base isolated two storey un‐reinforced masonry building model subjected to four prescribed input excitations is carried out to ascertain its effectiveness in controlling seismic response. To compare the performance of U‐FREI, same building is placed directly on the shake table without isolator, and fixed base (FB) condition is simulated by restraining the base of the building with the shake table. Dynamic response characteristic of base isolated (BI) masonry building subjected to different intensities of input earthquakes is compared with the response of the same building without base isolation system. Acceleration response amplification and peak response values of test model with and without base isolation system are compared for different intensities of table acceleration. Distribution of shear forces and moment along the height of the structure and response time histories indicates significant reduction of dynamic responses of the structure with U‐FREI system. This study clearly demonstrates the improved seismic performance of un‐reinforced masonry building model supported on U‐FREIs under the action of considered ground motions. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
This paper presents the results of an experimental investigation carried out to investigate the seismic performance of a two storey brick masonry house with one room in each floor. A half‐scale building constructed using single wythe clay brick masonry laid in cement sand mortar and a conventional timber floor and timber roof clad with clay tiles was tested under earthquake ground motions on a shaking table, first in the longitudinal direction and then in the transverse direction. In each direction, the building was subjected to different ground motions with gradually increasing intensity. Dynamic properties of the system were assessed through white‐noise tests after each ground motion. The building suffered increasing levels of damage as the excitations became more severe. The damage ranged from cracking to global/local rocking of different piers and partial out‐of‐plane failure of the walls. Nevertheless, the building did not collapse under base excitations with peak ground acceleration up to 0.8g. General behaviour of the tested building model during the tests is discussed, and fragility curves are developed for unreinforced masonry buildings based on the experimental results. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
This study presents a seismic fragility analysis of low‐rise masonry in‐filled (MI) reinforced concrete (RC) buildings using a proposed coefficient‐based spectral acceleration method. The coefficient‐based method, without requiring any complicated finite element analysis, is a simplified procedure for assessing the spectral acceleration demand (or capacity) of buildings subjected to earthquakes. This paper begins with a calibration of the proposed coefficient‐based method for low‐rise MI RC buildings using published experimental results obtained from shaking table tests. Spectral acceleration‐based fragility curves for low‐rise MI RC buildings under various inter‐story drift limits are then constructed using the calibrated coefficient‐based method. A comparison of the experimental and estimated results indicates that the simplified coefficient‐based method can provide good approximations of the spectral accelerations at peak loads of low‐rise MI RC buildings, if a proper set of drift‐related factors and initial fundamental periods of structures are used. Moreover, the fragility curves constructed using the coefficient‐based method can provide a satisfactory vulnerability evaluation for low‐rise MI RC buildings under a given performance level. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
Eight half‐scale brick masonry walls were tested to study two important aspects of confined masonry (CM) walls related to its seismic behavior under in‐plane and out‐of‐plane loads. Four solid wall specimens tested to investigate the role of type of interface between the masonry and tie‐columns, such as toothing varying from none to every course. The other four specimens with openings were tested to study the effectiveness of various strengthening options around opening to mitigate their negative influence. In the set of four walls, one wall was infilled frame while the other three were CM walls of different configurations. The experimental results were further used to determine the accuracy of various existing models in predicting the in‐plane response quantities of CM walls. Confined masonry walls maintained structural integrity even when severely damaged and performed much better than infill frames. No significant effect of toothing details was noticed although toothing at every brick course was preferred for better post‐peak response. For perforated walls, provision of vertical elements along with continuous horizontal bands around openings was more effective in improving the overall response. Several empirical and semi‐empirical equations are available to estimate the lateral strength and stiffness of CM walls, but those including the contribution of longitudinal reinforcement in tie‐columns provided better predictions. The available equations along with reduction factors proposed for infills could not provide good estimates of strength and stiffness for perforated CM walls. However, recently proposed relations correlating strength/stiffness with the degree of confinement provided reasonable predictions for all wall specimens. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
The critical parameters that influence the nonlinear seismic response of asymmetric‐plan buildings are identified by evaluating the effects of different asymmetries that may characterize the structure of a building as well as exploring the influence of the ground motion features. First, the main findings reported in the literature on both the linear and nonlinear dynamic response of asymmetric‐plan buildings are presented. The common findings and the conflicting conclusions reached in different investigations are pointed out. Then, the results of comprehensive nonlinear dynamic analyses performed for evaluating the seismic response of systems characterized by different strength and stiffness configurations, representative of a large class of asymmetric‐plan buildings, are reported. Findings from the study indicate that the building response changes when moving from the linear to the nonlinear range, so that the seismic behavior of asymmetric‐plan buildings, apart from the source of asymmetry, can be always classified as irregular. Additionally, it was observed that as the seismic demands cause amplification of system nonlinearity with increasing earthquake intensity, the maximum displacement demand in the different resisting elements tends to be reached with the same deformed configuration of the system. The resultant of the seismic forces producing such a maximum demand is located at the center of resistance and corresponds to the collapse mechanism of the system that provides the maximum lateral strength in the exciting direction of the seismic action. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

14.
The evaluation of the out‐of‐plane behaviour of unreinforced walls is one of the most debated topics in the seismic assessment of existing masonry buildings. The discontinuous nature of masonry and its interaction with the remainder of the building make the dynamic modelling of out‐of‐plane response troublesome. In this paper, the results of a shaking table laboratory campaign on a tuff masonry, natural scale, U‐shaped assemblage (façade adjacent to transverse walls) are presented. The tests, excited by scaled natural accelerograms, replicate the behaviour of external walls in existing masonry buildings, from the beginning of rocking motion to overturning. Two approaches have been developed for modelling the out‐of‐plane seismic behaviour: the discrete element method and an SDOF analytic model. Both approaches are shown to be capable of reproducing the experimental behaviour in terms of maximum rotation and time history dynamic response. Finally, test results and numerical time history simulations have been compared with the Italian seismic code assessment procedures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
One of the main challenges in earthquake risk mitigation is the assessment of existing buildings not designed according to modern codes and the development of effective techniques to strengthen these structures. Particular attention should be given to RC frame structures with masonry infill panels, as demonstrated by their poor performance in recent earthquakes in Europe. Understanding the seismic behaviour of masonry‐infilled RC frames presents one of the most difficult problems in structural engineering. Analytical tools to evaluate infill–frame interaction and the failure mechanisms need to be further studied. This research intends to develop a simplified macro‐model that takes into account the out‐of‐plane behaviour of the infill panels and the corresponding in‐plane and out‐of‐plane interaction when subjected to seismic loadings. Finally, a vulnerability assessment of an RC building will be performed in order to evaluate the influence of the out‐of‐plane consideration in the building response. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
The paper proposes a systematic comparison between two methods of analysis that are well established in the field of earthquake engineering: nonlinear dynamic analysis and nonlinear static procedure (NSP), applied to the out‐of‐plane seismic response of two masonry façades representative of many ancient Italian churches. The comparison is based on extensive numerical analyses, which focus on the flexural and torsional mechanisms, while the in‐plane damage mechanisms and the possible detachment between the façade and the lateral walls because of a poor connection have been presently disregarded. The computations, both in the static and in the dynamic field, are based on a rigid body and spring model specifically implemented for this issue, computationally efficient and equipped with a realistic model of damage and hysteresis at the mesoscale. An innovative aspect of this study is the heuristic modelling of three‐wythe masonry, to include some typical texture effects on the macroscale nonlinear response. For each façade, two different masonry textures were considered, performing extensive dynamic analyses that offered a detailed overview about the performance under earthquakes of different intensities. In parallel, NSP and the classical N2‐based seismic assessment were applied. A critical discussion and comparison of the results of the two methods is presented to rationally appraise limits and opportunities. In particular, flexural and twisting out‐of‐plane mechanisms were clearly appraised in the dynamic field, whereas NSPs were not always able to describe the collapse, because they missed the partial failures determined by higher vibration modes, as could be expected. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
Observation of damage caused by the recent Abruzzo earthquake on April 6th 2009 showed how local interaction between infills and RC structures can lead to soft‐storey mechanisms and brittle collapses. Results of the present case study are based on observed damage caused by the earthquake in the zone of Pettino. Analytical model based on simulated design procedure was built up and time history analyses were employed to verify the causes of the structural collapse, as highlighted by observed damage. This failure mechanism was investigated taking into consideration all components of the ground motion. Nonlinear behavior of brick masonry infills was taken into account and two parametric hypotheses for infill mechanical properties were considered, given the uncertainties that typically characterize these nonstructural elements. Nonlinear modeling of infills was made by a three‐strut macro‐model aimed at considering both local and global interaction between RC frame and infills. Seismic input was characterized by the real signal registered during the mainshock near the case‐study structure. Different shear capacity models were considered in the assessment. Analytical results seem to confirm with good approximation the likely collapse scenario that damage observation highlighted; the lack of proper detailing in the columns made the local interaction between infills and RC columns and the strong vertical component of the ground motion to be the main causes of the brittle failure. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
A simplified numerical model was used to investigate the out‐of‐plane seismic response of vertically spanning unreinforced masonry (URM) wall strips. The URM wall strips were assumed to span between two flexible diaphragms and to develop a horizontal crack above the wall mid‐height. Three degrees of freedom were used to accommodate the wall displacement at the crack height and at the diaphragm connections, and the wall dynamic stability was studied. The equations of dynamic motion were obtained using principles of rocking mechanics of rigid bodies, and the formulae were modified to include semi‐rigid wall behaviour. Parametric studies were conducted that included calculation of the wall response for different values of diaphragm stiffness, wall properties, applied overburden, wall geometry and earthquake ground motions. The results of the study suggest that stiffening the horizontal diaphragms of typical low‐rise URM buildings will amplify the out‐of‐plane acceleration demand imposed on the wall and especially on the wall–diaphragm connections. It was found that upper‐storey walls connected to two flexible diaphragms had reduced stability for applied earthquake accelerograms having dominant frequency content that was comparable with the frequency of the diaphragms. It was also found that the applied overburden reduced wall stability by reducing the allowable wall rotations. The results of this study suggest that the existing American Society of Civil Engineers recommendations for assessment of vertically spanning walls overestimate the stability of top‐storey walls in multi‐storey buildings in high‐seismic regions or for walls connected to larger period (less stiff) diaphragms. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
Seismic assessment of existing unreinforced masonry buildings represents a current challenge in structural engineering. Many historical masonry buildings in earthquake regions were not designed to withstand seismic loading; thus, these structures often do not meet the basic safety requirements recommended by current seismic codes and need to be strengthened considering the results from realistic structural analysis. This paper presents an efficient modelling strategy for representing the nonlinear response of unreinforced masonry components under in‐plane cyclic loading, which can be used for practical and accurate seismic assessment of masonry buildings. According to the proposed strategy, generic masonry perforated walls are modelled using an equivalent frame approach, where each masonry component is described utilising multi‐spring nonlinear elements connected by rigid links. When modelling piers and spandrels, nonlinear springs are placed at the two ends of the masonry element for describing the flexural behaviour and in the middle for representing the response in shear. Specific hysteretic rules allowing for degradation of stiffness and strength are then used for modelling the member response under cyclic loading. The accuracy and the significant potential of the proposed modelling approach are shown in several numerical examples, including comparisons against experimental results and the nonlinear dynamic analysis of a building structure. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
Multi‐storey buildings made of cross‐laminated timber panels (X‐lam) are becoming a stronger and economically valid alternative in Europe compared with traditional masonry or concrete buildings. During the design process of these multi‐storey buildings, also their earthquake behaviour has to be addressed, especially in seismic‐prone areas such as Italy. However, limited knowledge on the seismic performance is available for this innovative massive timber product. On the basis of extensive testing series comprising monotonic and reversed cyclic tests on X‐lam panels, a pseudodynamic test on a one‐storey X‐lam specimen and 1D shaking table tests on a full‐scale three‐storey specimen, a full‐scale seven‐storey building was designed according to the European seismic standard Eurocode 8 and subjected to earthquake loading on a 3D shaking table. The building was designed with a preliminary action reduction factor of three that had been derived from the experimental results on the three‐storey building. The outcomes of this comprehensive research project called ‘SOFIE – Sistema Costruttivo Fiemme’ proved the suitability of multi‐storey X‐lam structures for earthquake‐prone regions. The buildings demonstrated self‐centring capabilities and high stiffness combined with sufficient ductility to avoid brittle failures. The tests provided useful information for the seismic design with force‐based methods as defined in Eurocode 8, that is, a preliminary experimentally based action reduction factor of three was confirmed. Valid, ductile joint assemblies were developed, and their importance for the energy dissipation in buildings with rigid X‐lam panels became evident. The seven‐storey building showed relatively high accelerations in the upper storeys, which could lead to secondary damage and which have to be addressed in future research. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号