首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
基于能量分析的地震损伤性能评估   总被引:7,自引:0,他引:7  
结合能量分析法和文献[1]提出的钢筋混凝土框架结构“三水准”地震损伤性能目标,采用改进的双参数线性组合地震损伤模型,本文提出了基于能量分析的地震损伤性能评估方法;通过算例说明了本文提出的抗震性能评估方法不仅能够准确地分析结构在大震作用下的地震损伤性能,而且思路简洁、计算方便、可用于结构抗震性能评估;另外,本文提出的地震损伤模型具有较强的灵活性,可适用于不同钢筋混凝土构件和结构的抗震性能评估。  相似文献   

2.
Passive energy dissipation devices are increasingly implemented in frame structures to improve their performance under seismic loading. Most guidelines for designing this type of system retain the requirements applicable to frames without dampers, and this hinders taking full advantage of the benefits of implementing dampers. Further, assessing the extent of damage suffered by the frame and by the dampers for different levels of seismic hazard is of paramount importance in the framework of performance‐based design. This paper presents an experimental investigation whose objectives are to provide empirical data on the response of reinforced concrete (RC) frames equipped with hysteretic dampers (dynamic response and damage) and to evaluate the need for the frame to form a strong column‐weak beam mechanism and dissipate large amounts of plastic strain energy. To this end, shake‐table tests were conducted on a 2/5‐scale RC frame with hysteretic dampers. The frame was designed only for gravitational loads. The dampers provided lateral strength and stiffness, respectively, three and 12 times greater than those of the frame. The test structure was subjected to a sequence of seismic simulations that represented different levels of seismic hazard. The RC frame showed a performance level of ‘immediate occupancy’, with maximum rotation demands below 20% of the ultimate capacity. The dampers dissipated most of the energy input by the earthquake. It is shown that combining hysteretic dampers with flexible reinforced concrete frames leads to structures with improved seismic performance and that requirements of conventional RC frames (without dampers) can be relieved. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
Current seismic design requirements for special concentrically braced frames (SCBFs) in chevron configurations require that the beams supporting the braces be designed to resist the demands resulting from the simultaneous yielding of the tension brace and degraded, post-buckling strength of the compression brace. Recent research, including large-scale experiments and detailed finite-element analyses, has demonstrated that limited beam yielding is not detrimental to chevron braced frame behavior and actually increases the story drift at which the braces fracture. These findings have resulted in new expressions for computing beam demands in chevron SCBFs that reduce the demand in the tension brace to be equal to the expected compressive capacity at buckling of the compression brace. In turn, the resultant force on the beam is reduced as is the required size of the beam. Further study was undertaken to investigate the seismic performance of buildings with SCBFs, including chevron SCBFs with and without yielding beams and X-braced frames. Prototype three- and nine-story braced frames were designed using all three framing systems, that is, chevron, chevron with yielding beams, and X SCBFs, resulting in six building frames. The nonlinear dynamic response was studied for ground motions simulating two different seismic hazard levels. The results were used to characterize the seismic performance in terms of the probability of salient damage states including brace fracture, beam vertical deformation, and collapse. The results demonstrate that the seismic performance of chevron SCBFs with limited beam yielding performs as well as or better than the conventionally designed chevron and X SCBFs.  相似文献   

4.
Hysteretic energy dissipation in a structure during an earthquake is the key factor, besides maximum displacement, related to the amount of damage in it. This energy demand can be accurately computed only through a nonlinear time‐history analysis of the structure subjected to a specific earthquake ground acceleration. However, for multi‐story structures, which are usually modeled as multi‐degree of freedom (MDOF) systems, this analysis becomes computation intensive and time consuming and is not suitable for adopting in seismic design guidelines. An alternative method of estimating hysteretic energy demand on MDOF systems is presented here. The proposed method uses multiple ‘generalized’ or ‘equivalent’ single degree of freedom (ESDOF) systems to estimate hysteretic energy demand on an MDOF system within the context of a ‘modal pushover analysis’. This is a modified version of a previous procedure using a single ESDOF system. Efficiency of the proposed procedure is tested by comparing energy demands based on this method with results from nonlinear dynamic analyses of MDOF systems, as well as estimates based on the previous method, for several ground motion scenarios. Three steel moment frame structures, of 3‐, 9‐, and 20‐story configurations, are selected for this comparison. Bias statistics that show the effectiveness of the proposed method are presented. In addition to being less demanding on the computation time and complexity, the proposed method is also suitable for adopting in design guidelines, as it can use response spectra for hysteretic energy demand estimation. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
This paper presents shake‐table tests conducted on a two‐fifths‐scale reinforced concrete frame representing a conventional construction design under current building code provisions in the Mediterranean area. The structure was subjected to a sequence of dynamic tests including free vibrations and four seismic simulations in which a historical ground motion record was scaled to levels of increasing intensity until collapse. Each seismic simulation was associated with a different level of seismic hazard, representing very frequent, frequent, rare and very rare earthquakes. The structure remained basically undamaged and within the inter‐story drift limits of the ‘immediate occupancy’ performance level for the very frequent and frequent earthquakes. For the rare earthquake, the specimen sustained significant damage with chord rotations of up to 28% of its ultimate capacity and approached the upper bound limit of inter‐story drift associated with ‘life safety’. The specimen collapsed at the beginning of the ‘very rare’ seismic simulation. Besides summarizing the experimental program, this paper evaluates the damage quantitatively at the global and local levels in terms of chord rotation and other damage indexes, together with the energy dissipation demands for each level of seismic hazard. Further, the ratios of column‐to‐beam moment capacity recommended by Eurocode 8 and ACI‐318 to guarantee the formation of a strong column‐weak beam mechanism are examined. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

6.
普通钢筋混凝土低矮剪力墙抗震性能较差,其抗震性能的改善一直受到工程界的关注。总结了一些改善低矮剪力墙抗震性能的国内外研究成果,包括:开缝低矮剪力墙、带暗支撑低矮剪力墙、设耗能装置的低矮剪力墙和低矮组合剪力墙等。在此基础上,提出了一种新型耗能剪力墙,并进行了初步的试验研究。  相似文献   

7.
密肋复合墙板耗能性能及地震损伤分析   总被引:2,自引:0,他引:2  
根据15榀1/2比例密肋复合墙板在单调及低周反复荷载作用下的试验结果,对这种新型复合墙板的破坏形态、滞回性能、耗能能力和累积损伤模型等进行了分析,探讨了墙板累积损伤的发展过程和发育规律,提出了阶段损伤指数的概念,并通过损伤模型计算的破损结果与试件实际破坏特征对比,确定了墙板的阶段损伤界限值,可供工程实际抗震设计和评估参考。  相似文献   

8.
河北省测震台网中小地震矩震级的测定   总被引:3,自引:0,他引:3  
利用河北省测震台网的数字地震波形资料,反演了2008年12月至2010年4月62个中小地震的震源波谱参数,计算了这些地震的地震矩M0和矩震级Mw,利用正交回归分析方法得到了近震体波震级ML和Mw之间的关系式.  相似文献   

9.
An effective strategy of seismic retrofitting consists of installing nonlinear viscous dampers between the existing building, with insufficient lateral resistance, and some auxiliary towers, specially designed and erected as reaction structures. This allows improving the seismic performance of the existing building without any major alteration to its structural and nonstructural elements, which makes this approach particularly appealing for buildings with heritage value. In this paper, the nonlinear governing equations of the coupled lateral‐torsional seismic motion are derived from first principles for the general case of a multistory building connected at various locations in plan and in elevation to an arbitrary number of multistory towers. This formulation is then used to assess the performance of the proposed retrofitting strategy for a real case study, namely, a 5‐story student hall of residence in the city of Messina, Italy. The results of extensive time‐history analyses highlight the key design considerations associated with the stiffness of the reaction towers and the mechanical parameters of the nonlinear viscous dampers, confirming the validity of this approach.  相似文献   

10.
Seismic tests have been conducted on two 3‐storey structures protected with pressurized fluid‐viscous spring damper devices. One of the structures was a reinforced concrete frame with clay elements in the slabs, while the other one was a steel frame with steel/concrete composite slabs. The spring dampers were installed through K bracing in between the floors. The tests were performed by means of the pseudodynamic method, which allowed the use of large and full‐size specimens, and by implementing a specific compensation strategy for the strain‐rate effect at the devices. The test results allowed the verification of the adequacy of the attachment system as well as the comparison of the behaviour of the unprotected buildings with several protected configurations, showing the benefits of the application of the devices and the characteristics of their performance. The response of the protected structures was always safer than that of the unprotected ones mainly due to a significant increase of equivalent damping. The increase in the damping ratio depends on the level of deformation. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

11.
基于皖东北地区多层砌体校舍抗震性能调查,结合汶川地震的震害,对皖东北地区中小学多层砌体校舍的特点、抗震能力进行阐述,运用易损性概率分析法对所调查的校舍进行震害预测,并提出了相应的防震减灾对策,以期为该地区校舍安全工程提供参考.  相似文献   

12.
为了研究装配式混凝土金属消能减震连接体系的抗震性能,对金属消能减震连接体系和普通预制装配式框架进行了数值仿真分析,分析了消能器不同设计参数对该体系抗震性能的影响。分析结果表明:金属消能减震连接体系的抗震性能优于普通预制装配式框架,屈服位移有显著提高,较好的延缓了梁端的破坏,对梁端保护作用明显,并且有效的解决了梁端后浇区施工困难的问题;金属消能器腹板高度越小耗能效果越好,但初始刚度及承载力也越小;翼缘板厚度越小消能器越早屈服耗能,但过小的翼缘板厚度会导致耗能能力不足,并且应变过大会导致其与梁柱连接部位被破坏;随着消能器高度的增加,构件跨中弯矩越大,也越早屈服耗能,但过大的消能器高度会导致其弯曲变形严重。  相似文献   

13.
A new concept to determine state of the damage in concrete gravity dams is introduced. The Pine Flat concrete gravity dam has been selected for the purpose of the analysis and its structural capacity, assuming no sliding plane and rigid foundation, has been estimated using the two well‐known methods: nonlinear static pushover (SPO) and incremental dynamic analysis (IDA). With the use of these two methods, performance and various limit states of the dam have been determined, and three damage indexes have been proposed on the basis of the comparison of seismic demands and the dam's capacity. It is concluded that the SPO and IDA can be effectively used to develop indexes for seismic performance evaluation and damage assessment of concrete gravity dams. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
The mechanical characteristics of earthquake‐resistant structures and the ground motion properties that have an important influence on the seismic performance of structures with asymmetric load–deformation behaviour, are identified from the results obtained from a parametric study of the dynamic response of single‐degree‐of‐freedom systems. The dynamic response of tilted single and multi‐degree‐of‐freedom systems, designed according to Mexican requirements for the design of asymmetric structures is studied. After a general understanding of this phenomenon is offered, shortcomings in current design requirements for tilted structures are discussed. Research needs to establish a rational design approach of this type of structures are identified. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

15.
提出了一种新型扇形盘式效能器(fanshaped disc-type energy dissipator,FDED),阐明了其原理、特点,导出其设计要点和设计理论,采用数值方法分析了FDED的减震性能,研究不同设计参数对FDED减震性能的影响。结果表明:FDED设计原理可行,减震机理明确,其转盘式的构造可起到有效的位移放大效果,使得消能器在小激励位移下发挥耗能作用;FDED具有明显的双线性恢复力特性和稳定的耗能性能,等效黏滞阻尼系数可达50%以上;阻尼件中橡胶硬度的改变对FDED初始刚度的影响不敏感,但对FDED屈服后刚度和等效黏滞阻尼系数的影响较为明显。随着橡胶硬度的增大,FDEDE的屈服后刚度上升,等效黏滞阻尼系数降低;保持阻尼层中橡胶层的总厚度不变,通过增减叠层钢板改变单层橡胶层的厚度对于调整FDED的减震性能影响不大;调整铅芯直径的大小主要影响FDED的屈服力和耗能性能。随着铅芯直径的增大,FDED的屈服力也增大,耗能能力逐渐提高。  相似文献   

16.
Despite the inherently advantages of the box column, finding the best option for the I beam to the box column connection is the main challenge in using the box column as a structural member for special moment frames. In this paper, the seismic performance of unreinforced connection, weakened connection and strengthened connection was evaluated through a comprehensive experimental program. The seismic comparisons were fabricated by assessing the strength, ductility and energy dissipation in each configuration. Three full scale tests with several connections were carried out. All the specimens were subjected to cyclic loading and prior to failure by forming a plastic hinge in the beam, all the connections managed to reach an inelastic rotation of more than 6.0% rad. The experimental and analytical results showed that the seismic performance of the strengthened connection with flange and shear plates turned out to be the most effective in the beam to the box column connection. Moreover, the normalized stress distribution of the continuity plates revealed that the possibility of the weld fracture in unreinforced connection is more than other specimens.  相似文献   

17.
Reinforced concrete waffle‐flat plate (WFP) structures present 2 important drawbacks for use as a main seismic resisting system: low lateral stiffness and limited ductility. Yet the former can serve a positive purpose when, in parallel, the flexible WFP structure is combined with a stiff system lending high‐energy dissipation capacity, to form a “flexible‐stiff mixed structure.” This paper experimentally investigates the seismic performance of WFP structures (flexible system) equipped with hysteretic dampers (stiff system) through shake‐table tests conducted on a 2/5‐scale test specimen. The WFP structure was designed only for gravitational loads. The lateral strength and stiffness provided by the dampers at each story were, respectively, about 3 and 7 times greater than those of the bare WFP structure. The mixed system was subjected to a sequence of seismic simulations representing frequent to very rare ground motions. Under the seismic simulations associated with earthquakes having return periods ranging from 93 to 1894 years, the WFP structure performed in the level of “immediate occupancy,” with maximum interstory drifts up to about 1%. The dampers dissipated most (75%) of the energy input by the earthquake.  相似文献   

18.
由于流体本身的粘滞性和摩擦性,使得地震波在含油气地层中传播时衰减形成低频阴影.通过对叠后地震资料做时频分解,分析地层衰减特征,是当前除了AVO技术之外,比较流行的直接识别流体和气藏的技术.本文基于波动方程正演,模拟了地震波对含油气地层的响应.然后采用连续小波变换分析不同尺度剖面的瞬时能量特征,提取分频剖面上每一个点的峰值能量对应的频率,得到瞬时峰值能量频率剖面.通过分析瞬时峰值能量频率剖面,分析了地震波在地下介质中传播时的衰减特征.最后应用此方法对实际地震剖面进行了分析,验证了其有效性.  相似文献   

19.
Shaking table tests were conducted on a scaled reinforced concrete waffle–flat plate structure. It represented a conventional construction design under current building codes in the Mediterranean area. The test structure was subjected to a sequence of four seismic simulations of increasing magnitude. Each simulation was associated with a seismic hazard level characterized by the mean return period PR. The test structure performed well for the simulations associated with PR = 95, 475 and 975 years but collapsed under the maximum considered earthquake of PR = 2475 years. Damage concentrated at column bases, where the maximum chord rotation reached 93% of the ultimate capacity, and at the transverse beams of the exterior plate‐to‐column connection that failed in torsion. It is shown that most (from 85% to 90%) of the energy input by the earthquake that contributes to damage is dissipated by the plate. The capacity curve of the tested structure estimated from the experimental base shear vs. top displacement relationship allowed us to compute the overstrength (1.4). It is close to the maximum established by European code EN 1998‐1 (1.5). Based on a detailed study of the test results, potential updates to current codes and design recommendations are suggested. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

20.
耐震时程法(ETA)仅需少量的非线性时程分析,便可以掌握结构倒塌破坏的全过程。但是,此方法目前较少应用于结构倒塌失效分析。本文探讨了耐震时程曲线的特性及拟合思路,以钢筋混凝土框架为研究对象,应用ETA方法分析了钢筋混凝土框架的地震响应及损伤发展。研究结果:(1)混凝土框架结构的地震响应分析结果表明:采用ETA方法分析时结构顶点位移和层间位移角与采用IDA方法分析时接近,而最大基底剪力会略大;但是,两种方法的结果相关系数均接近于1。(2)强震下的结构倒塌分析结果表明:ETA方法能较为准确的预测结构的塑性铰分布、塑性铰出现概率及塑性铰发展顺序。当采用多条耐震时程加速度曲线作为输入时,评估结果准确性更高。由于ETA方法仅需进行少量几条耐震时程分析且计算高效,因此ETA方法可以成为预测结构失效模式的高效方法。  相似文献   