首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A gusset plate is subjected to forces induced from a buckling‐restrained brace (BRB) and frame action. In this study, a performance‐based design method of the gusset connections incorporating a BRB and frame actions is investigated. The force demands resulting from the BRB axial force are computed from the generalized uniform force method. The force demands induced from the frame action effects primarily result from beam shear. A conservative method, which considers the beam axial force effect and the thereafter reduced beam flexural capacity possibly developed at the gusset tips, is adopted in estimating the maximum beam shear. An improved equivalent strut model is used to represent the gusset plate subjected to the frame action effect. The total force demands of the gusset connection are combined from the BRB force and the frame actions. For design purposes, the stress distributions on the gusset interfaces are linearized. The maximum von Mises stress combining the normal and shear stresses is considered as the demand for the gusset plate design. In order to verify the effectiveness of the proposed design method, experiments on a two‐story full‐scale buckling‐restrained braced frame (BRBF) were performed. The chevron and single diagonal brace configurations were arranged in the second and the first stories, respectively. Two different corner gusset connection configurations including one single corner gusset and one coupled corner gusset connection, where two braces in adjacent stories joined at the same beam‐to‐column joint, were tested. The BRBF specimen was subjected to cyclically increasing lateral displacements with a maximum frame drift of 0.04 rad. The maximum story drifts reached 0.035 and 0.061 rad. in the first and the second stories, respectively. At the end of the tests, no fractures were observed on any of the gusset interfaces. Along the gusset interfaces, the normal and shear stress distributions computed from the proposed design procedures and the FEM analysis correlated well with the experimental results. This paper concludes with the procedure and recommendations for the performance‐based design of gusset connections. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
The design of a three‐story buckling‐restrained braced frame (BRBF) with a single‐diagonal sandwiched BRB and corner gusset was evaluated in cyclic tests of a one‐story, one‐bay BRBF subassembly and dynamic analyses of the frame subjected to earthquakes. The test focused on evaluating (1) the seismic performance of a sandwiched BRB installed in a frame, (2) the effects of free‐edge stiffeners and dual gusset configurations on the corner gusset behavior, (3) the frame and brace action forces in the corner gusset, and (4) the failure mode of the BRBF under the maximum considerable earthquake level. The subassembly frame performed well up to a drift of 2.5% with a maximum axial strain of 1.7% in the BRB. Without free‐edge stiffeners, the single corner gusset plate buckled at a significantly lower strength than that predicted by the specificationof American Institute of Steel Construction (2005). The buckling could be eliminated by using dual corner gusset plates similar in size to the single gusset plate. At low drifts, the frame action force on the corner gusset was of the same magnitude as the brace force. At high drifts, however, the frame action force significantly increased and caused weld fractures at column‐to‐gusset edges. Nonlinear time history analyses were performed on the three‐story BRBF to obtain seismic demands under both design and maximum considerable levels of earthquake loading. The analytical results confirmed that the BRB and corner gusset plate achieved peak drift under cyclic loading test. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
This paper is Part II of a two‐part paper describing a full‐scale 3‐story 3‐bay concrete‐filled tube (CFT)/buckling‐restrained braced frame (BRBF) specimen tested using psuedo‐dynamic testing procedures. The first paper described the specimen design, experiment, and simulation, whereas this paper focuses on the experimental responses of BRBs and BRB‐to‐gusset connections. This paper first evaluates the design of the gusset connections and the effects of the added edge stiffeners in improving the seismic performance of gusset connections. Test results suggest that an effective length factor of 2.0 should be considered for the design of the gusset plate without edge stiffeners. Tests also confirm that the cumulative plastic deformation (CPD) capacity of the BRBs adopted in the CFT/BRBF was lower than that found in typical component tests. The tests performed suggest that the reduction in the BRB CPD capacities observed in this full‐scale frame specimen could be due to the significant rotational demands imposed on the BRB‐to‐gusset joints. A simple method of computing such rotational demands from the frame inter‐story drift response demand is proposed. This paper also discusses other key experimental responses of the BRBs, such as effective stiffness, energy dissipation, and ductility demands. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

4.
The corner gusset plates in a steel braced frame can be subjected to forces not only from the brace but also from the effects of the frame actions. In this study, several finite element models are constructed to analyze the gusset‐to‐beam and gusset‐to‐column interface forces. It is found that the frame actions affect the gusset interface force distributions significantly. A simplified strut model to represent the gusset plate is adopted to evaluate the frame action forces. In addition, the generalized uniform force method is adopted as it provides more freedom for designers to configure the gusset plate shapes than using the uniform force method. In this paper, a performance‐based design method is proposed. The gusset interface force demands take into account the combined effect of the brace maximum axial force capacity and the peak beam shear possibly developed in the frame. The specimen design and key results of a series of full‐scale three‐story buckling‐restrained braced frame (BRBF) hybrid tests are discussed. The gusset interface cracks observed at inter‐story drift greater than 0.03 radians can be well predicted by using the proposed design method. The BRBF tests and analyses confirm that the proposed design method is reasonable. The effectiveness of varying the width of gusset edge stiffeners in reducing the gusset tip stress concentrations is also investigated. This paper concludes with recommendations for the seismic design of BRBF corner gusset plates. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
A series of hybrid and cyclic loading tests were conducted on a three‐story single‐bay full‐scale buckling‐restrained braced frame (BRBF) at the Taiwan National Center for Research on Earthquake Engineering in 2010. Six buckling‐restrained braces (BRBs) including two thin BRBs and four end‐slotted BRBs, all using welded end connection details, were installed in the frame specimen. The BRBF was designed to sustain a design basis earthquake in Los Angeles. In the first hybrid test, the maximum inter‐story drift reached nearly 0.030 rad in the second story and one of the thin BRBs in the first story locally bulged and fractured subsequently before the test ended. After replacing the BRBs in the first story with a new pair, a second hybrid test with the same but reversed direction ground motion was applied. The maximum inter‐story drifts reached more than 0.030 rad and some cracks were found on the gusset welds in the second story. The frame responses were satisfactorily predicted by both OpenSees and PISA3D analytical models. The cyclic loading test with triangular lateral force distribution was conducted right after the second hybrid test. The maximum inter‐story drift reached 0.032, 0.031, and 0.008 rad for the first to the third story, respectively. This paper then presents the findings on the local bulging failure of the steel casing by using cyclic test results of two thin BRB specimens. It is found that the steel casing bulging resistance can be computed from an equivalent beam model constructed from the steel core plate width and restraining concrete thickness. This paper concludes with the recommendations on the seismic design of thin BRB steel casings against local bulging failure. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
A two‐story buckling‐restrained brace (BRB) frame was tested under bidirectional in‐plane and out‐of‐plane loading to evaluate the BRB stability and gusset plate design. The test comprised pseudo‐dynamic loadings using the 1999 Chi‐Chi earthquake scaled to the 50%, 10%, and 2% probability of exceedance in 50 years and a cyclic regime of increasing amplitudes of up to 3.0% story drift ratio (SDR). The specimen had a unique configuration where the beams were connected to the columns through shear tabs welded to the column flanges and bolted to the beam webs. Stable hysteretic behavior with only minor cracking at the gusset‐to‐column welds was observed under the pseudo‐dynamic tests, with maximum in‐plane and out‐of‐plane SDRs of 2.24% and 1.47% respectively. Stable behavior continued into the cyclic test where fracture of the gusset‐to‐column welds occurred in the first cycle to simultaneous bidirectional SDR of 3.0%. The observed BRB stability is consistent with a methodology developed for BRB frames under simultaneous in‐plane and out‐of‐plane drifts. The specimen behavior was studied using a finite element model. It was shown that gusset plates are subjected to a combination of BRB force and frame action demands, with the latter increasing the gusset‐to‐beam and gusset‐to‐column interface demands by an average of 69% and 83% respectively. Consistent with the test results, failure at the gusset‐to‐column interfaces is computed when frame action demands are included, thus confirming that not considering frame action demands may results in unconservative gusset plate designs. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

7.
The implementation of buckling‐restrained braces (BRBs) for new reinforced concrete frame (RCF) constructions is limited. This study investigates the seismic forces and stability in the BRBs and gussets of a 2‐story full‐scale RCF specimen by using Abaqus models and a newly proposed stability evaluation method. The hybrid and cyclic loading test results are accurately predicted by the Abaqus analyses. Existing methods for computing the gusset interface forces for steel buildings from both the brace and the frame actions are compared with the Abaqus results. The applicability of these methods for the BRB‐RCF design is critically evaluated. It is confirmed that the Parallel‐2 method is suitable for estimating the BRB force demand imposed on the corner gusset and the generalized uniform force method is good for the corner gusset at the base. In addition, existing stability evaluation methods for BRBs and gussets are applied to investigate the out‐of‐plane (OOP) buckling of the first‐story BRB observed at the end of tests. The proposed stability model incorporates the BRB restrainer's flexural effects and 4 rotational springs in assessing the BRB's buckling. This model confirms that the BRB and the gusset's OOP buckling limit states could be coupled and must be evaluated together. By incorporating the flexural effects of the steel casing and the infilled grout, the proposed model satisfactorily predicts the OOP buckling of the first‐story BRB and gussets. These research results can be used for the implementation of BRBs in new RC frame constructions.  相似文献   

8.
In‐plane buckling‐restrained brace (BRB) end rotation induced by frame action is a commonly observed phenomenon in buckling‐restrained braced frames (BRBFs). However, its effect on BRB end connection behavior has not yet been clear. In this study, four BRB end deformation modes for quick determination of end rotational demand are proposed for non‐moment BRBF considering different BRB arrangements, installing story of BRBs, and boundary condition of corner gussets connected with column base. Key factors affecting BRB end rotation and flexural moments are examined theoretically by parametric analysis. Subassemblage tests of seven BRB specimens under horizontal cyclic loading were conducted by adopting two loading frames to impose the expected BRB end deformations. It shows that BRB end rotation subjected BRB ends to significant flexural moments, leading to premature yielding of BRB ends or even tendency of end zone buckling. The deformation modes, the flexural rigidity of BRB ends, and the initial geometric imperfections of BRBs were found to have significant influence on BRB end connection behavior. The triggering moment induced by BRB end rotation was the main contributor to end flexural moment. However, the moment amplification effect induced by flexure of BRB end zones became prominent especially for small flexural rigidity of BRB ends. Implications and future research needs for design of BRB end connections are provided finally based on the theoretical and experimental results. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
This paper proposes a novel implementation of buckling‐restrained braces (BRB) in new reinforced concrete (RC) frame construction. Seismic design and analysis methods for using a proposed steel cast‐in anchor bracket (CAB) to transfer normal and shear forces between the BRB and RC members are investigated. A full‐scale two‐story RC frame with BRBs (BRB‐RCF) is tested using hybrid and cyclic loading test procedures. The BRBs were arranged in a zigzag configuration and designed to resist 70% of the story shear. The gusset design incorporates the BRB axial and RCF actions, while the beam and column members comply with ACI 318‐14 seismic design provisions. Test results confirm that the BRBs enhanced the RCF stiffness, strength, and ductility. The hysteresis energy dissipation ratios in the four hybrid tests range from 60% to 94% in the two stories, indicating that BRBs can effectively dissipate seismic input energy. When the inter‐story drift ratio for both stories reached 3.5% in the cyclic loading test, the overall lateral force versus deformation response was still very stable. No failure of the proposed steel CABs and RC discontinuity regions was observed. This study demonstrates that the proposed design and construction methods for the CABs are effective and practical for real applications. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
A new buckling restrained braced frame system is proposed for reinforced concrete building structures, which is featured by the zigzag configuration of the braces and the corresponding connection details. The connection details tend to separate the vertical and horizontal components of force imposed by the braces to be resisted by independent structural components to make the behavior of the connection easier to estimate and control. The performance of the brace connection details was evaluated through cyclic load testing on 1/2‐scale subassemblies of the proposed system, each of which consisted of a reinforced concrete part and a set of buckling restrained braces. To simplify the test control, the specimens were rotated 90° in the test and were loaded by two displacement controlled actuators. The test results show that the normal and the shear resistance of the gusset plate connection are essentially independent of each other. However, the rotation of the gusset plate with respect to the beam‐to‐column joint may result in nonuniform force distribution of the anchor bolts, the primary resistance for tensile force. At the same time, such rotation may also subject the concrete corbels, the primary shear resistance, to unfavorable tensile force. In addition, it is also confirmed that the buckling restrained braces performed well in the proposed system. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
A thin‐profile buckling‐restrained brace (thin‐BRB) consists of a rectangular steel casing and a flat steel core that is parallel to a gusset plate. A thin configuration reduces the width of the restraining member and thus saves usable space in buildings. However, deformable debonding layers, which cover the steel core plate in order to mitigate the difference between the peak tensile and compressive axial forces, provide a space for the steel core to form high mode buckling waves when the thin‐BRB is under compression. The wave crests squeeze the debonding layers and produce outward forces on the inner surface of the restraining member. If the restraining member is too weak in sustaining the outward forces, local bulging failure occurs and the thin‐BRB loses its compression capacity immediately. In order to investigate local bulging behavior, a total of 22 thin‐BRB specimens with a ratio of steel core plate to restraining steel tube depth ranging from 0.3 to 0.7 and axial yield force capacities ranging from 421 kN to 3036 kN were tested by applying either cyclically increasing, decreasing, or constant axial strains. The restraining steel tube widths of all the specimens were smaller than 200 mm and were infilled with mortar with a compressive strength of 97 MPa or 55 MPa. Thirteen of the 22 thin‐BRB specimens' restraining members bulged out when the compressive core strains exceeded 0.03. A seismic design method of the thin‐BRB in preventing local bulging failure is proposed in this study. Test and finite element model (FEM) analysis results suggest that the outward forces can be estimated according to the BRB compressive strength, steel core high mode buckling wavelength, and the debonding layer thickness. In addition, the capacity of the restraining member in resisting the outward forces can be estimated by using the upper bound theory in plastic analysis. Both the FEM analysis and test results indicate that the proposed method is effective in predicting the possibility of local bulging failure. Test results indicate that the proposed design method is conservative for thin‐BRB specimens with a large steel core plate to restraining steel tube depth ratio. This paper concludes with design recommendations for thin‐BRBs for severe seismic services. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
A series of pseudo‐dynamic tests (PDTs) of a full‐scale 3‐story 3‐bay buckling‐restrained braced frame (BRBF) using concrete‐filled tube columns was tested in the Taiwan National Center for Research on Earthquake Engineering using networked PDT techniques in October 2003. During the tests, real‐time experimental responses and video were webcasted to Internet viewers. The input ground motions adopted for the PDTs were chosen from the 1999 Chi‐Chi and the 1989 Loma Prieta earthquakes and scaled to represent three seismic hazard levels. This paper is in two parts, focusing on the investigations of the overall structure and the local members. This paper constitutes Part I and discusses the design, analytical investigations, and key experimental results of the specimen frame, such as the buckling of the brace‐to‐gusset joints. Part II of the paper, the companion paper, describes the gusset stiffening schemes and detailed experimental behavior of the BRBs and their connections. Experimental peak inter‐story drifts of 0.019 and 0.023 radians, prescribed for the design basis and the maximum credible earthquakes, respectively, are within the target design limits of 0.020 and 0.025 radians. These tests confirmed that the PISA3D and OpenSees nonlinear structural analysis computer programs can simulate the experimental peak shears and floor displacements well. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
The seismic performance tests of a full‐scale five‐story passively controlled steel building were conducted on the E‐Defense shaking table in Japan in March 2009. Before the tests, a blind prediction contest was held to allow researchers and practitioners from all over the world to construct analytical models and predict the dynamic responses of the steel frame specimen equipped with buckling‐restrained braces (BRBs) or viscous dampers (VDs). This paper presents the details of two refined prediction models made and results obtained before the tests. When the proposed analytical modeling techniques are adopted as in the two refined prediction models, the overall prediction accuracy is about 90%. Sensitivity studies conducted after the tests are also presented in this paper. The effects of varying each modeling feature on the response simulation accuracy have been investigated. The analytical results suggest that considering concrete full‐composite actions for beam members could improve prediction accuracy by about 20% against using the simplified bare steel beam model. Adopting refined BRB stiffness computed from incorporating finite‐element gusset stiffness only improves the overall prediction accuracy by 0.9%. Considering the BRB dynamic loading test results for analytical BRB strength reduces the error by 1.9%. For the VD frame, incorporating the brace and VD stiffness could improve the overall prediction accuracy by about 15%. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
为分析支撑布置方式、刚度比、结构总层数等因素在罕遇地震下对屈曲约束支撑框架结构动力响应的影响,借助有限元分析软件SAP2000,分别对6层、12层、18层屈曲约束支撑框架结构模型进行了罕遇地震下的时程分析,详细研究了多高层结构体系的层间位移角、底层剪力、支撑内力等随支撑布置方式、刚度比、结构总层数等因素变化的规律。分析表明,倒V较单斜布置更能有效降低底层剪力、增大支撑轴力、降低层间位移角,从而降低结构的地震响应,更有利于结构消能减震;随着结构总层数的增大,支撑的屈服层数呈现出增多的趋势;刚度比七为2—4时,能使较多层数的屈曲约束支撑参与到消能减震的过程之中,较好地实现抗震设防目标。  相似文献   

15.
Cyclic loading tests and finite element analyses on six novel all‐steel buckling‐restrained braces (BRBs) are conducted using different loading patterns to investigate the core plate high‐mode buckling phenomenon. The proposed BRB is composed of a core member and a pair of identical restraining members, which restrains the core member by using bolted shim spacers. The design of the proposed BRB allows the core plate to be visually inspected immediately following a major earthquake. If necessary, the pair of restraining members can be conveniently disassembled, and the damaged core plate can be replaced. Test results indicate that the proposed BRBs can sustain large cyclic strain reversals and cumulative plastic deformations in excess of 400 times the yield strain. Experimental and analytical results confirm that the high‐mode buckling wavelength is related to the core plate thickness and the applied loading patterns. The larger the axial compressive strain is applied, the shorter the high‐mode buckling wavelength would be developed. The buckling wavelength is about 12 times the core plate thickness when the high‐mode buckling shape is fully developed. However, it reduces to about 10 times the core plate thickness when a compressive core strain reaches greater than 0.03. The high‐mode bucking wavelength can be satisfactorily predicted using the proposed method or from the finite element analysis. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
Buckling‐restrained braces (BRBs) are widely used as ductile seismic‐resistant and energy‐dissipating structural members in seismic regions. Although BRBs are expected to exhibit stable hysteresis under cyclic axial loading, one of the key limit states is global flexural buckling, which can produce an undesirable response. Many prior studies have indicated the possibility of global buckling of a BRB before its core yields owing to connection failure. In this paper, BRB stability concepts are presented, including their bending‐moment transfer capacity at restrainer ends for various connection stiffness values with initial out‐of‐plane drifts, and a unified simple equation set for ensuring BRB stability is proposed. Moreover, a series of cyclic loading tests with initial out‐of‐plane drifts are conducted, and the results are compared with those of the proposed equations. © 2013 The Authors. Earthquake Engineering & Structural Dynamics published by John Wiley & Sons Ltd.  相似文献   

17.
Braced frames are one of the most economical and efficient seismic resisting systems yet few full‐scale tests exist. A recent research project, funded by the National Science Foundation (NSF), seeks to fill this gap by developing high‐resolution data of improved seismic resisting braced frame systems. As part of this study, three full‐scale, two‐story concentrically braced frames in the multi‐story X‐braced configuration were tested. The experiments examined all levels of system performance, up to and including fracture of multiple braces in the frame. Although the past research suggests very limited ductility of SCBFs with HSS rectangular tubes for braces recent one‐story tests with improved gusset plate designs suggest otherwise. The frame designs used AISC SCBF standards and two of these frames designs also employed new concepts developed for gusset plate connection design. Two specimens employed HSS rectangular tubes for bracing, and the third specimen had wide flange braces. Two specimens had rectangular gusset plates and the third had tapered gusset plates. The HSS tubes achieved multiple cycles at maximum story drift ratios greater than 2% before brace fracture with the improved connection design methods. Frames with wide flange braces achieved multiple cycles at maximum story drift greater than 2.5% before brace fracture. Inelastic deformation was distributed between the two stories with the multi‐story X‐brace configuration and top story loading. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
The debonding mechanism has a significant effect on the performance of a buckling‐restrained brace (BRB). In this paper, a method for estimating the compression strength adjustment factor for any given BRB core strain is presented. Experimental investigations were conducted on four BRBs to examine the efficiency of four different debonding materials in reducing the difference between the cyclic peak compression and tension. Test results indicate that chloroprene rubber is very easy to install and very effective in minimizing the difference between the compressive and tensile capacities. The excellent performance of 13 full‐scale welded end‐slot BRBs (WES‐BRBs) is illustrated through experiments. Cyclic loading test results of a 12.5‐m long jumbo WES‐BRB reveal that its peak compressive strength exceeds 16,800 kN and its maximum core strain reaches 0.035. All WES‐BRBs show satisfactory performance with a very stable hysteresis response, modest peak compressive to tensile strength ratio, and very predictable axial stiffness. These specimens sustain a cumulative plastic deformation of greater than 400 times the yield deformation. The hysteresis responses can be satisfactorily predicted by using a two‐surface plasticity analytical model. Advantages of the welded end‐slot connections are also presented through a discussion on the effects of the BRB yield region length ratio on the effective stiffness, the yield story drift, and the core strain level. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
防屈曲耗能支撑研究与应用的新进展   总被引:3,自引:0,他引:3  
周云  唐荣  钟根全  王浩 《地震学刊》2012,(4):393-407
防屈曲耗能支撑是一种性能优良的新型耗能减震构件。本文阐述了防屈曲耗能支撑的构成和基本原理,根据约束构件的不同材料形式,将防屈曲耗能支撑划分为混凝土约束型防屈曲耗能支撑、全钢型防屈曲耗能支撑和装配式防屈曲耗能支撑。分别介绍了防屈曲耗能支撑的类型与性能、防屈曲耗能支撑框架分析与子结构试验,以及防屈曲耗能支撑在工程中的应用情况和标准化。指出了防屈曲耗能支撑研究和推广应用中存在的问题,给出了今后研究与应用的建议。  相似文献   

20.
The authors developed a buckling‐restrained brace that enables increased design freedom at both ends of the core plate and strict quality control while providing stable hysteresis characteristics even under high strains. The buckling‐restrained brace can be formed by welding a core plate covered with unbonded material to a pair of mortar‐filled channel steels (steel mortar planks) as a restraining part. The use of this approach enables visual confirmation of the status of the mortar filling and also facilitates standardizing structural members and member‐by‐member quality control. Specimens of a buckling‐restrained brace with different steel mortar plank heights are fabricated to adjust the restraining force, along with specimens with different core plate width‐to‐thickness ratios. The tests were conducted to reveal the hysteretic characteristics of the braces, as well as their cumulative plastic strain energy, elastoplastic properties, and stiffening properties. A performance evaluation formula as well as a buckling‐restrained brace design method using the test results is proposed. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏