首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The scrap tire rubber pad(STRP) made by natural or synthetic rubber and high strength reinforcing cords exhibits substantial vertical stiffness and horizontal flexibility, and these properties can be regarded as suitable for seismic isolators for structures. The use of environmentally burdensome scrap tires as STRP isolators might be convenient as an efficient and low-cost solution for the implementation of aseismic design philosophy for low-to-medium rise buildings, especially in developing countries. Finite element analyses of unbonded square and strip-shaped STRP isolators subjected to a combination of axial and lateral loads are conducted to investigate its lateral deformation performance under seismic loading. The rubber of the isolator is modelled with Mooney-Rivlin hyperelastic and Prony viscoelastic materials, including the Mullins material damage effect. The influence of the length-to-width ratio and bearing height on the isolator performance is assessed in terms of the force-displacement relationship, horizontal stiffness, damping, and isolation periods. It is shown that the dependence of stiffness on the length-to-width ratio is significant in the longitudinal direction and minor in the transverse direction. The STRP isolators following the proposed design criteria are shown to satisfy the performance requirement at different levels of seismic demand specified by the ASCE/SEI 7-2010 seismic provisions.  相似文献   

2.
高层隔震建筑设计中隔震支座受拉问题分析   总被引:11,自引:0,他引:11  
高层建筑由于高宽比相对较大,倾覆效应明显,当采用隔震技术时,有可能使隔震支座出现拉应力,而通常使用的叠层橡胶隔震支座抗拉能力不强。因此,隔震支座受拉问题成为隔震技术在高层建筑中推广应用的主要障碍之一。本文提出了避免隔震支座受拉的上部结构布置原则及隔震层优化设计方法,并对目前隔震支座拉应力计算方法提出了改进建议。本文的研究工作可为工程设计提供借鉴,为隔震设计相关规范的修订提供依据。  相似文献   

3.
组合基础隔震在建筑工程中的应用   总被引:3,自引:1,他引:2  
隔震作为一种新的抗震技术,已广泛应用于新建和加固的建筑工程,同时,许多新型式的支座得到了开发和应用。组合基础隔震是一种新的隔震设计思想,能充分应用不同类型隔震支座的特性,有效降低上部结构地震反应。本文介绍了组合基础隔震在某一工程中的应用,工程中使用的支座包括普通橡胶隔震支座、铅芯橡胶隔震支座和弹性滑板支座三种类型,对全部使用支座进行了常规检测,结构计算采用等效线性法、能量包络法和时程反应分析等方法,计算结果表明:组合基础隔震能有效降低上部结构的反应,隔震层的变形控制在安全范围之内。  相似文献   

4.
The effects of damping in various laminated rubber bearings (LRB) on the seismic response of a ?‐scale isolated test structure are investigated by shaking table tests and seismic response analyses. A series of shaking table tests of the structure were performed for a fixed base design and for a base isolation design. Two different types of LRB were used: natural rubber bearings (NRB) and lead rubber bearings (LLRB). Three different designs for the LLRB were tested; each design had a different diameter of lead plug, and thus, different damping values. Artificial time histories of peak ground acceleration 0.4g were used in both the tests and the analyses. In both shaking table tests and analyses, as expected, the acceleration responses of the seismically isolated test structure were considerably reduced. However, the shear displacement at the isolators was increased. To reduce the shear displacement in the isolators, the diameter of the lead plug in the LLRB had to be enlarged to increase isolator damping by more than 24%. This caused the isolator stiffness to increase, and resulted in amplifying the floor acceleration response spectra of the isolated test structure in the higher frequency ranges with a monotonic reduction of isolator shear displacement. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

5.
Comparative study of the inelastic response of base isolated buildings   总被引:1,自引:0,他引:1  
This article presents a numeric comparative study of the inelastic structural response of base isolated buildings. The comparative study includes the following isolation systems: laminated rubber bearings, New Zealand one, pure friction and the frictional pendulum ones. The study is based on obtaining non‐linear response spectra for various design parameters using six earthquake records. Usually the base isolation of a new building seeks to maintain the structure in the linear elastic range. The response of old weak buildings or the response of new ones subjected to extreme earthquakes may not be, necessarily, in the aforementioned ideal elastic range. Consequently, it is important to characterize the response of isolated buildings responding inelastically. A conclusion from this research is that the isolators affect significantly the structural response of weak systems. Rubber isolators seem slightly less sensitive to plastification that may occur in the structure compared to friction isolators. Ductility demands in the structure are affected significantly by friction and neoprene protected systems, in particular sliding ones where larger demands are obtained. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

6.
New types of fiber‐reinforced rubber‐based seismic isolators have been a research interest for a number of engineers in the past decade. These new types of isolators can have similar seismic performances compared with the conventional ones. In most of the previous researches, the fiber‐reinforced rubber‐based isolators is usually manufactured with placing fiber sheets between precut rubber layers with the use of a bonding agent. This research differs from the previous researches in terms of manufacturing process, use of fiber mesh instead of fiber sheets, and use of lead in the core for some of the bearings. The aim of this research is to provide comparisons in fundamental seismic response properties of the new type of fiber mesh reinforced isolators and conventional isolators. In this scope, four pairs of fiber mesh reinforced elastomeric bearings and four pairs of steel‐reinforced elastomeric bearings are subjected to various levels of compression stresses and cyclic shear strains under constant vertical pressure. The tested types of isolators are fiber mesh reinforced elastomeric bearing, fiber mesh reinforced elastomeric bearing with lead core, steel‐reinforced elastomeric bearings, and steel‐reinforced elastomeric bearings with lead core. In this research, steel‐reinforced bearings are called conventional isolators. The major advantage for fiber mesh reinforced bearings observed during the tests is that these isolators can develop a considerable low horizontal stiffness compared with the conventional isolators. The damping characteristics of the new and conventional types are similar to each other. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
In this paper, the effectiveness of the base isolation on steel storage tanks has been investigated through numerical models and then checked by shaking table tests on a reduced scale (1:14) model of a real steel tank, typically used in petrochemical plants. In the experimental campaign the floating roof has also been taken into account. The tests have been performed on the physical model both in fixed and isolated base configurations; in particular two alternative base isolation systems have been used: high‐damping rubber bearings devices and sliding isolators with elasto‐plastic dampers. Finally, a comparison between experimental and numerical results has also been performed. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
Conventional steel-based rubber bearings are being replaced by fiber reinforced elastomeric isolators (FREI) due to their high weight and manufacturing cost. Compared to existing rubber bearings, FREIs have superior performance and as a result can control the seismic response of structures more efficiently. This study aims to simulate the performance of rectangular carbon FREIs (C-FREIs) produced through a simple and cost-effective manufacturing process. Additionally, the effect of different factors including the number and the thickness of rubber layers, as well as the thickness of carbon fiber reinforced sheets are investigated on the performance of C-FREIs through sensitivity analyses based on the results obtained from finite element simulations. The results show that by increasing the number and thickness of rubber layers, the efficiency of C-FREIs degrades in terms of vertical strength and damping capacity, however, the performance improves in terms of lateral flexibility. Another important observation is that the increasing thickness of fiber-reinforced layers can increase the vertical rigidity of the base isolator. The vertical stiffness has the most sensitivity to the thickness of elastomeric layers and the thickness of CFR sheets while, when the number of rubber layers increases, the effective lateral stiffness is mostly affected.  相似文献   

9.
The development of an efficient energy-dissipating mechanism that works in conjunction with laminated elastomeric bearings in order to reduce the lateral deformation of the isolation system has always been a goal of base isolation research. Theoretically, this deformation will be reduced to the minimum if damping augmentation of the isolation system can reach a critical value. However, augmenting the isolation damping may cause some unwanted side effects. The purpose of this paper is to study the influence of isolation damping on the seismic response of heavily damped base-isolated buildings. The base isolation system is assumed to be linearly viscoelastic and is analysed using the complex mode method. Solutions derived by using perturbation techniques for a two-degree-of-freedom system and the computer simulation for a multiple-degree-of-freedom system reveal that augmenting the isolation damping can reduce efficiently the deformation of the isolation system, but at the price of increasing the high-frequency vibration in the superstructure. When the damping ratio of the isolation system is beyond some level, increasing the isolation damping will enlarge the extreme values of the base and superstructural accelerations. It is also found that approximate solutions derived from the use of classical damping and classical modes of vibration in the seismic analysis of heavily damped base isolation systems can be substantially in error.  相似文献   

10.
组合橡胶支座及橡胶支座与柱串联系统的水平刚度计算方法   总被引:11,自引:0,他引:11  
目前基础隔震建筑中应用的叠层橡胶支座都是等截面的,其水平刚度是以遭遇强烈地震为依据设计的,当遭遇中小地震时水平刚度将偏大,致使上部结构的减震效果比遭遇设计地震时明显减小,而由两个不同截面橡胶支座组成的组合橡胶支座在不同强度地震时均能发挥较好设计的隔震效果。  相似文献   

11.
This paper describes the results of shaking table tests to ascertain the ultimate behavior of slender base‐isolated buildings and proposes a time history response analysis method, which can predict the ultimate behavior of base‐isolated buildings caused by buckling fracture in laminated rubber bearings. In the tests, a base‐isolated structure model weighing 192 kN supported by four lead rubber bearings is used. The experimental parameters are the aspect ratio of height‐to‐distance between the bearings and the shape of and the axial stress on the bearings. The test results indicate that the motion types of the superstructure at large input levels can be classified into three types: the sinking type; the uplift type; and the mixed type. These behaviors depend on the relationship between the static ultimate lateral uplifting force on the superstructure and the lateral restoring characteristics of the base‐isolated story. In the analysis method, bearing characteristics are represented by a macroscopic mechanical model that is expanded by adding an axial spring to an existing model. Nonlinear spring characteristics are used for its rotational, shear, and axial spring. The central difference method is applied to solve the equation of motion. To verify the validity of the method, simulation analysis of the shaking table tests are carried out. The results of the analysis agree well with the test results. The proposed model can express the buckling behavior of bearings in the large deformation range. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
Experimental Investigations on Laminated Rubber Bearings   总被引:1,自引:0,他引:1  
Increasing application of base isolation as a seismic protection method has subsequently increased its analytical and experimental studies. Being the most critical part of the base isolated buildings, accurate evaluation of structural properties and precise modeling of isolation devices is of utmost importance in predicting the response of the buildings during the earthquakes. This technical note is concerned with experimental study on laminated rubber bearings. Free vibration and harmonic base excitation tests are performed on a three-storey building model to evaluate the properties of the structure, efficiency of the system, and effect of base excitations. It is found that these experimental methods can effectively be used for this purpose.  相似文献   

13.
本文研究土与结构相互作用(SSI)对多层及中高层基础隔震建筑地震需求及隔震效率的影响规律,隔震层采用LRB铅芯橡胶与LNR普通橡胶隔震支座组合,就我国现行《建筑抗震设计规范》(GB50011-2010)中软土场地设置隔震层问题做探讨。提出土与基础隔震结构相互作用的简化计算模型,对不同场地及隔震设计目标下的多层及中高层基础隔震结构进行时程分析。研究表明:软土场地基础隔震建筑隔震层的有效隔震效率相对于硬土场地有所下降,必须通过设置具有一定规格的LRB支座来满足隔震目标。本文给出了铅芯橡胶支座极限变形需求随建筑层高及隔震目标变化的规律。  相似文献   

14.
A comprehensive parametric study on the inelastic seismic response of seismically isolated RC frame buildings, designed for gravity loads only, is presented. Four building prototypes, with 23 m × 10 m floor plan dimensions and number of storeys ranging from 2 to 8, are considered. All the buildings present internal resistant frames in one direction only, identified as the strong direction of the building. In the orthogonal weak direction, the buildings present outer resistant frames only, with infilled masonry panels. This structural configuration is typical of many existing RC buildings, realized in Italy and other European countries in the 60s and 70s. The parametric study is based on the results of extensive nonlinear response‐time history analyses of 2‐DOF systems, using a set of seven artificial and natural seismic ground motions. In the parametric study, buildings with strength ratio (Fy/W) ranging from 0.03 to 0.15 and post‐yield stiffness ratio ranging from 0% to 6% are examined. Three different types of isolation systems are considered, that is, high damping rubber bearings, lead rubber bearings and friction pendulum bearings. The isolation systems have been designed accepting the occurrence of plastic hinges in the superstructure during the design earthquake. The nonlinear response‐time history analyses results show that structures with seismic isolation experience fewer inelastic cycles compared with fixed‐base structures. As a consequence, although limited plastic deformations can be accepted, the collapse limit state of seismically isolated structures should be based on the lateral capacity of the superstructure without significant reliance on its inherent hysteretic damping or ductility capacity. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
In many applications of seismic isolation, such as in high‐rise construction, lightweight construction, and structures with large height‐to‐width aspect ratios, significant tension forces can develop in bearings, raising concerns about the possible rupture of elastomeric bearings and the uplift of sliding bearings. In this paper, a novel tension‐resistant lead plug rubber bearing (TLRB) with improved tension‐resisting capabilities is developed and experimentally and numerically assessed. This TLRB consists of a common lead plug rubber bearing (LRB) and several helical springs. After describing the theory underlying the behavior of the TLRB, the mechanical properties of reduced‐scale prototype bearings are investigated through extensive horizontal and vertical loading tests. The test results indicate that TLRBs can improve the shear stiffness and tension resistance capacity even under significant tensile loads. A series of shaking table tests on scaled models of high‐rise buildings with different aspect ratios were conducted to investigate the dynamic performance of the TLRB and the seismic responses of base‐isolated high‐rise buildings. Three different cases were considered in the shaking table tests: a fixed base condition and the use of TLRB and LRB isolation systems. The results of the shaking table test show that (a) base‐isolated systems are effective in reducing the structural responses of high‐rise buildings; (b) an isolated structure's aspect ratio is an important factor influencing its dynamic response; (c) TLRBs can endure large tensile stresses and avoid rupture on rubber bearings under strong earthquakes; and (d) the experimental and numerical results of the responses of the models show good agreement. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

16.
The nuclear accident at Fukushima Daiichi in March 2011 has led the nuclear community to consider seismic isolation for new large light water and small modular reactors to withstand the effects of beyond design basis loadings, including extreme earthquakes. The United States Nuclear Regulatory Commission is sponsoring a research project that will quantify the response of low damping rubber (LDR) and lead rubber (LR) bearings under loadings associated with extreme earthquakes. Under design basis loadings, the response of an elastomeric bearing is not expected to deviate from well‐established numerical models, and bearings are not expected to experience net tension. However, under extended or beyond design basis shaking, elastomer shear strains may exceed 300% in regions of high seismic hazard, bearings may experience net tension, the compression and tension stiffness will be affected by isolator lateral displacement, and the properties of the lead core in LR bearings will degrade in the short‐term because of substantial energy dissipation. New mathematical models of LDR and LR bearings are presented for the analysis of base isolated structures under design and beyond design basis shaking, explicitly considering both the effects of lateral displacement and cyclic vertical and horizontal loading. These mathematical models extend the available formulations in shear and compression. Phenomenological models are presented to describe the behavior of elastomeric isolation bearings in tension, including the cavitation and post‐cavitation behavior. The elastic mechanical properties make use of the two‐spring model. Strength degradation of LR bearing under cyclic shear loading due to heating of lead core is incorporated. The bilinear area reduction method is used to include variation of critical buckling load capacity with lateral displacement. The numerical models are coded in OpenSees, and the results of numerical analysis are compared with test data. The effect of different parameters on the response is investigated through a series of analyses. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
For the purpose of predicting the large‐displacement response of seismically isolated buildings, an analytical model for elastomeric isolation bearings is proposed. The model comprises shear and axial springs and a series of axial springs at the top and bottom boundaries. The properties of elastomeric bearings vary with the imposed vertical load. At large shear deformations, elastomeric bearings exhibit stiffening behavior under low axial stress and buckling under high axial stress. These properties depend on the interaction between the shear and axial forces. The proposed model includes interaction between shear and axial forces, nonlinear hysteresis, and dependence on axial stress. To confirm the validity of the model, analyses are performed for actual static loading tests of lead–rubber isolation bearings. The results of analyses using the new model show very good agreement with the experimental results. Seismic response analyses with the new model are also conducted to demonstrate the behavior of isolated buildings under severe earthquake excitations. The results obtained from the analyses with the new model differ in some cases from those given by existing models. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
A series of numerical experiments on the performance of different base isolation systems for a non-uniform shear beam structure is carried out. Several base isolation systems are considered and the peak relative displacements and the maximum absolute accelerations of the base-isolated structure and its base raft under a variety of conditions are evaluated. Several sensitivity analyses for variations in properties of the base isolator and the structure are carried out. A number of different earthquake excitations are also used in the study. The results show that performances of the base isolation systems are not sensitive to small variations in their natural period, damping or friction coefficient. The presence of a frictional element in the isolators reduces their sensitivity to severe variations in frequency content and amplitude of the ground acceleration. In particular, the resilient-friction base isolators with or without sliding upper plate perform reasonably well under a variety of loading conditions. The rubber bearing type, however, leads to the lowest peak transmitted accelerations for moderate intensity earthquakes.  相似文献   

19.
本文提出了一种基于叠层橡胶支座的大高宽比高层建筑分段隔震结构形式,并对同一高层建筑结构分别采用基础隔震、层间隔震和分段隔震三种不同形式时进行了数值模拟对比分析。结果表明,采用分段隔震形式可明显减小高层建筑结构的顶层侧向位移、中间隔震层的相对位移和下支柱端应力,使结构的侧向位移集中于两个隔震层上,耗散了大部分地震输入能量,保障了与隔震层相连的构件的安全性,防止了由于支座受拉或剪压破坏导致上部结构倾覆倒塌现象的发生。  相似文献   

20.
滑移摩擦隔震系统在多向地面运动作用下的试验研究   总被引:7,自引:2,他引:7  
基础隔震通常只考虑隔离水平地面运动,而对竖向地面运动的影响注意不够,本文进行了滑移摩擦隔震系统的振动台房屋模型试验,研究多向地面运动输入时上部结构反应和隔震系统的性能,试验中分别对模型输入了不同方向的地震动,其中包括水平单向、水平双向、水平和竖向及三向地震动输入,对试验结果进行了分析比较,结果表明竖向地震动输入对上部结构的水平地震反应有显著影响,同时在橡胶隔震支座中产生了竖向拉力。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号