首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 912 毫秒
1.
采用硝酸-氢氟酸-过氧化氢于微波消解仪中分解样品,电感耦合等离子体质谱法测定贵州遵义地区某黑色页岩中稀有稀土元素的含量。对页岩标准物质(GBW 07107)和水系沉积物地球化学成分分析标准物质(GBW07305、GBW 07310)的分析,测定值与标准值相一致。对黑色页岩的分析结果较好,方法精密度(RSD,n=6)各元素均小于4%,加标回收率为97.9%~100.1%。方法准确度高、简单、快捷,一次溶样可同时测定多种元素。  相似文献   

2.
The methodologies developed in this work comprise ion-exchange separation of interfering elements from rare earth elements (Fe, Al and Ca), by using resin minicolumns (Dowex-50W-X8 200-400 mesh) for the determination of La, Ce, Nd, Sm, Eu, Gd, Dy, Ho, Er, Yb and Lu by inductively coupled plasma-atomic emission spectrometry, using both off-line and on-line continuous flow systems. These methods can be used to determine rare earth elements in common silicate rocks, such as granite, basalt, rhyolite and andesite. Thirteen geochemical reference materials were used to evaluate the accuracy and precision of the off-line and on-line methods. Chondrite-normalized diagrams were obtained and compared to values reported in the literature. When compared to conventional procedures, the proposed methods provide fast and low cost rare earth elements determinations in the analysis of silicate rocks. Eighteen samples per hour could be analysed by the proposed method using the automated procedure for the determination of the eleven rare earth elements.  相似文献   

3.
采用电感耦合等离子体质谱,硝酸-氢氟酸-双氧水增压密闭消解样品,实现了苹果中43种元素含量的同时测定。比较了采取干样和鲜样进行多元素同时测定时的相关性,干样和鲜样中元素比值为0.9~1.1,证实了干样和鲜样测定结果具有很好的一致性。各元素的检出限在0.000 9~2.862 0μg/L,相对标准偏差为1.13%~3.45%。比较了不同元素在果皮和果肉中的分布,结果表明:果皮中的元素含量明显高于果肉,稀土元素在果皮富集明显。  相似文献   

4.
微波密闭消解-等离子体质谱法测定岩石样品中的稀土元素   总被引:17,自引:14,他引:17  
马英军  刘丛强 《岩矿测试》1999,18(3):189-192
建立了有微波密封HF+HNO3消解样品,等离子体质谱测定岩石样品中15个稀土元素的分方法。用该方法对国内外岩石标准品进行测定,结果表明稀土元素的测定值与标准值之间的相对偏差小于5%,检出限为(0.1-0.9)*10^-9,多次测定结果的相对标准偏差在1.3%-5.2%。各类实际岩石样品中稀土元素的分析结果均与地质规律相符,进一步证明了方法的可靠性。  相似文献   

5.
稀土稀有稀散元素现代仪器测试全新方法的建立   总被引:1,自引:0,他引:1  
本文系统总结了自2011年以来在三稀矿产实验测试方面取得的新进展。重点介绍了离子相稀土单元素浸泡提取实验研究、稀土原产地Nd同位素与微量元素示踪技术研究、离子吸附型稀土样品野外现场快速定性定量手持X射线荧光(XRF)分析研究成果。结果表明,采用25%硫酸铵浸泡提取,电感耦合等离子体光、质谱(ICP- AES、ICP- MS)测定,可以清晰反映出各稀土元素的浸泡提取率;采用高精度多接收电感耦合等离子体质谱仪(MC- ICP- MS)进行稀土矿石中Nd143/Nd144同位素比值测定,其比值差异可以示踪不同稀土矿石产地;通过精确测试分析不同产地稀土精矿样品中的稀土和其他微量元素含量,并进行数据相关性分析和数据分类分析,通过Y、Be和Bi三种元素含量的比较,可以判断稀土精矿来源;野外现场快速分析,20分钟可完成1件样品测试,不仅可定性判断是否为离子吸附型稀土,同时可定量各离子相稀土单元素含量,与室内精确分析结果符合性良好,可为我国离子吸附型稀土矿床的找矿快速筛查提供技术支撑。 同时介绍了混合酸微波分解样品- 电感耦合等离子体光、质谱(ICP- AES、ICP- MS)同时测定钨矿石、钼矿石、铌钽矿石中的多种稀有稀散稀土元素含量的方案。该方案的特点在于采用了耐氢氟酸体系,尤其对高含量W、Nb、Ta样品更具优势,否则易产生水解,导致测定结果系统偏低。同时梳理总结了我国常见三稀矿石地质样品的特点,针对不同矿种、不同矿床样品类型与基体特点,以及所测试元素种类的不同,研究建立了专门针对“稀有、稀散、稀土元素”现代仪器分析的10个全新的配套方法及其相应的技术指标(准确度、精密度、检出限),可满足地质矿产实验室测试质量管理的规范要求,而且为我国三稀金属矿产资源的战略调查、国家重点研发计划“深地锂资源探测”和四川甲基卡等地找矿突破做出了贡献。  相似文献   

6.
对P507萃淋树脂分离稀土元素的条件进行了实验,拟定了以P507萃淋树脂为固定相,HCl为流动相分离4N级荧光材料Eu_2O_3中14种稀土杂质元素的流程,使被测杂质与基体Eu_2O_3达到了较好的分离;再用阳离子交换树脂分离被测液中非稀土杂质元素。选择了端视ICP-AES测量稀土杂质元素的最佳条件。称样量50mg时各杂质组分的测定下限(ug/g)为:CeO_2、Pr_6O_(11)、Nd_2O_3、Sm_2O_3、Tb_4O_7、Ho_2O_3、Er_2O_3,Tm_2O_3、Lu_2O_30.4,La_2O_3、Gd_2O_3、0.2,Dy_2O_3、Y_2O_30.04,Yb_2O_30.02。6次取样分析,各杂质组分加入量为10ug/g(CeO_2为2ug/g),加入回收率在84%~112%;RSD<13%。方法可用于纯度在99.99%~99.9995%Eu_2O_3中14种稀土杂质元素的测定。  相似文献   

7.
X射线荧光光谱法测定矿物中轻重稀土   总被引:5,自引:3,他引:5  
without Octupole Reaction System and the ICP-MS with ORSSHI Yan-zhi1, WANG Ying-feng1, HE Run-ju其含量转换为轻、重稀土的总量。方法已用于实际样品测定,结果与化学法相符,10次测定的相对标准偏差分别为:CeO2的RSD为1.43%,Y2O3的RSD为1.11%。  相似文献   

8.
用电感耦合等离子体质谱法(ICP-MS)测定地质样品中的稀土及难熔元素,混合酸敞开酸溶法和碱熔融法是两种主要的溶样方法。但地质样品组分复杂,元素之间存在相互共生的现象,对于特殊元素、特殊样品用传统酸溶法会造成部分元素消解不完全,使测定结果不准确;而碱熔法的操作过程繁琐,且溶液盐度高,易产生基体干扰和堵塞仪器进样系统。本文改进了传统四酸和五酸体系,采用氢氟酸-硝酸-硫酸敞开酸溶体系,用国家一级标准物质制作标准曲线测定15种稀土元素,方法准确度(ΔlgC)为0.001~0.027。同时改进了偏硼酸锂碱熔法,样品用偏硼酸锂碱熔提取,加入氢氧化钠调节溶液至碱性条件,所测元素与偏硼酸锂共沉淀后过滤分离熔剂,再用硝酸复溶测定15种稀土元素及铌钽锆铪。两种溶样方法的测定值与认定值的相对误差为1.09%~9.30%。将混合酸敞开酸溶法测定稀土元素、偏硼酸锂碱熔法测定铌钽锆铪的结果与其他实验室密闭酸溶法相比,两组数据的相对偏差为0.13%~15.32%。本实验表明,混合酸敞开酸溶法适用于测定地质样品中的稀土元素,偏硼酸锂碱熔法不仅适用于测定地质样品中的稀土元素及铌钽锆铪,也适用于测定如古老高压变质岩石及铝含量高的样品中的铌钽锆铪。  相似文献   

9.
锂能源金属的战略地位不断提高,与锂矿床及锂金属相关的研究也在不断跟进,锂矿区土壤重金属污染近年来持续受到关注,其含量分布情况值得深入研究。本文对亚洲最大的锂矿区——川西甲基卡根系土壤环境进行重金属含量监测,调查和评价锂矿区土壤重金属含量水平及其安全性。2016—2018年于川西甲基卡锂资源富集区采集根系土壤样品68件,采用电感耦合等离子体质谱法(ICP-MS)测定根系土壤Cd、As、Pb、Cr、Cu、Ni、Zn含量。测试结果表明,甲基卡矿区根系土壤Cd、As、Pb、Cr、Cu、Ni、Zn含量平均值分别为0.13、15.31、25.47、60.57、16.12、23.59、66.83mg/kg,与2018年8月最新颁布的农用地土壤标准对比,无一超标,均低于风险筛选值及管制值。常见矿床的尾矿库区土壤一般存在严重的重金属污染,而甲基卡尾矿库土壤重金属含量均低于环境标准限值,且矿业活动停止的三年期间尾矿库区根系土壤中Cd、As、Cr含量明显呈逐年下降趋势。本研究认为,选矿厂房及尾矿库周边根系土壤重金属由于人为源的存在有一定的富集现象,但不构成危害,废弃物对环境污染小。  相似文献   

10.
采用电感耦合等离子体质谱法(ICP-MS)测定伴生重晶石轻稀土矿中的稀土元素时,Ba以及轻稀土元素La、Ce、Pr、Nd、Sm等对中重稀土造成严重的质谱重叠干扰,因此在保证矿石完全消解的同时,若能选择合适的前处理方法实现目标元素与基体的有效分离,将有利于减少质谱干扰。本文采用过氧化钠-碳酸钠熔融分解伴生重晶石的稀土矿样品,熔融物用三乙醇胺溶液提取,将沉淀过滤去除硅、铁、锰、铝等大量基体元素,而稀土元素与钡、锶、钙等留存于沉淀中,沉淀经盐酸溶解后再用氨水进行二次沉淀,将稀土元素与伴生的高含量钡、锶、钙等元素分离,分离率超过96%,从而极大地降低了由钡的氧化物和氢氧化物对~(153)Eu等元素质量数的质谱干扰。轻稀土元素对中重稀土元素的干扰则通过测定高浓度的单元素标准溶液在m/z 138~175处的表观浓度来计算干扰校正系数,对干扰量进行扣除校正。该方法通过稀土矿石标准物质GBW07187、GBW07188验证,测定值与认定值的相对误差10%;应用于伴生重晶石稀土矿石实际样品分析,相对标准偏差(RSD,n=12)为0.5%~4.6%,证明了本方法可用于分析高钡矿石中的稀土元素。  相似文献   

11.
王冠  李华玲  任静  杨波  胡志中 《岩矿测试》2013,32(4):561-567
电感耦合等离子体质谱(ICP-MS)用于测定稀土元素经常会引起M+、MO+、MOH+离子的质谱重叠干扰,其中制约分析准确度和精密度的主要因素是多原子离子干扰,尤其是轻稀土元素的氧化物和氢氧化物对重稀土元素的干扰,以及钡的7个天然同位素形成的氧化物和氢氧化物对轻稀土元素的干扰.本文采用高温高压密闭消解地质样品,高分辨电感耦合等离子体质谱法(ICP-MS)测定其中的痕量稀土元素,研究了低、中、高三种分辨率模式下氧化物的干扰情况,确定了最佳的测定同位素和合适的分辨率.分析结果表明,在低、中分辨率模式下,轻稀土元素Ce、Pr、Nd、Sm的氧化物和Ba的氧化物干扰明显,Gd元素的测定值严重偏离;在高分辨模式下,Ba氧化物对Eu的干扰以及大部分轻稀土元素氧化物对重稀土元素的干扰基本可以消除,无需进行校正,而只有157Gd受到141pr16O的干扰突出,当样品中Pr/Gd的浓度比值大于100时,Gd的测量值必须进行数学校正.  相似文献   

12.
Experimental and analytical procedures devised for measurement of rare earth element (REE) abundances using a secondary ion mass spectrometer (ion microprobe) are described. This approach is more versatile than the conventional techniques such as neutron activation analysis and isotope dilution mass spectrometry by virtue of its high spatial resolution that allows determination of REE abundances in small domains (10-20 micron) within individual mineral phases. The ion microprobe measurements are performed at a low mass-resolving power adopting the energy-filtering technique (Zinner and Crozaz 1986) for removal and suppression of unresolved complex molecular interferences in the REE masses of interest. Synthetic standards are used for determining various instrument specific parameters needed in the data deconvolution procedure adopted for obtaining REE abundances. Results obtained from analysis of standards show that our ion microprobe may be used for determining REE abundances down to ppm range with uncertainties of ∼ 10 to 15%. Abundances of rare earth and several other refractory trace elements in a set of early solar system objects isolated from two primitive carbonaceous chondrites were determined using the procedures devised by us. The results suggest that some of these objects could be high temperature nebular condensates, while others are products of melting and recrystallization of precursor nebular solids in a high temperature environment.  相似文献   

13.
杜梅  刘晓杰 《岩矿测试》2014,33(2):218-223
包头矿中的稀土总量根据提取稀土的工艺流程,含量范围为0.0x%~0.x%。对于高含量稀土总量(20%~80%)的测定,国家标准采用草酸盐重量法,但该方法分离干扰元素的步骤多,流程长。应用电感耦合等离子体发射光谱法不需复杂的分离步骤即可测定稀土元素,但由于受到精密度的限制,测定高含量稀土总量的波动范围较大,不易得到准确结果。本文针对包头稀土矿组成复杂、酸溶难于分解的情况,建立了应用碱熔处理样品,电感耦合等离子体发射光谱(ICP-AES)测定稀土总量的方法。用氢氧化钠、过氧化钠溶解样品,水提取熔融物,各种元素以离子或氢氧化物形式进入溶液,过滤除去铝、硅、磷等杂质元素及大量的钠盐,减小了基体元素及共存元素的干扰;以钪为内标校正仪器波动及基体效应的影响,无需基体匹配即可测定稀土总量。对于稀土总量在30%~50%的样品,相对标准偏差小于0.7%,对于稀土总量在2%的样品,相对标准偏差小于1.2%;各稀土元素回收率为98.0%~103.3%。本方法比国家标准方法简便,与文献中应用ICP-AES测定高含量稀土总量的方法相比精密度有很大改善,可快速准确地测定包头稀土矿中2%~50%的稀土总量。  相似文献   

14.
电感耦合等离子体质谱法测定井间示踪剂中稀土元素   总被引:2,自引:3,他引:2  
以甲醇为稀释剂,用电感耦合等离子体质谱法快速测定稀土示踪剂中17个稀土元素。研究表明,在优化的稀释剂甲醇浓度为2%(体积分数)、pH<2.47的条件下测定稀土元素,方法精密度(RSD)为1.23%~2.83%,日间6次测定的精密度为2.25%~4.76%,各稀土元素线性关系良好,检出限为2.0~9.0 ng/L;17个稀土元素的加标回收率为85%~108%,满足痕量元素分析要求。  相似文献   

15.
碳酸盐岩中碳酸盐矿物稀土元素分析方法进展   总被引:1,自引:0,他引:1  
碳酸盐岩中测定碳酸盐矿物的稀土元素主要有酸溶-ICP-MS和LA-ICP-MS方法.酸溶-ICP-MS方法用盐酸、硝酸溶解碳酸盐矿物,但也能溶解部分非碳酸盐矿物,而影响分析结果;用醋酸溶样可避免非碳酸盐矿物的干扰,但可能没有溶样完全,同样影响分析结果.LA-ICP-MS是应用激光对碳酸盐矿物进行原位剥蚀,将蒸发物导入ICP-MS进行分析,对不合粘土等的碳酸盐矿物最有效,由于激光束光斑较大,且碳酸盐岩中普遍含有微小的粘土矿物,可能也存在不确定性.总体而言,酸溶-ICP-MS和LA-ICP-MS获得的稀土元素页岩标准化配分模式及主要参数相似,均可用于沉积环境的示踪.  相似文献   

16.
后河岩体位于华北克拉通南缘崤山北部,岩体侵位于太古宙太华超群地层中,主要岩性是黑云母石英二长岩和黑云母二长花岗岩。黑云母石英二长岩和黑云母二长花岗岩的锆石U-Pb年龄分别为(131.0±1.8) Ma和(127.3±1.0) Ma。地球化学特征表明二者均具有富钾(K2O/Na2O =1.00~1.51)、过铝(A/CNK =1.12~1.17)、贫镁(Mg#=26~34)的特征,属高钾钙碱性系列的过铝质花岗岩。轻重稀土元素分馏程度较高,富集轻稀土,亏损重稀土,总体富集大离子亲石元素(LILE)而亏损高场强元素(HFSE),Eu异常不明显(δEu=0.84~0.97),(La/Yb)N比值高。Hf同位素特征显示,εHf(t)具有明显的负值(-17.8~-9.5),TDM2主要集中在2.3~1.7 Ga。综上所述,早白垩世后河岩体是华北克拉通南缘加厚下地壳部分熔融的产物,形成于地壳由挤压加厚向伸展减薄转换的阶段。  相似文献   

17.
胡璇 《岩矿测试》2020,39(6):954-960
采用电感耦合等离子体发射光谱法(ICP-OES)测定铝土矿中的稀土氧化物时,酸溶往往造成溶样不彻底,高温碱熔时大量的熔剂会降低稀土元素的发射强度,同时由于稀土氧化物含量(0.0010%~0.050%)较低,存在铝、铁等基体干扰,难以准确测定。本文采用氢氧化钠熔融铝土矿样品,熔融物用热水浸取,三乙醇胺溶液掩蔽铝和铁,乙二胺四乙酸二钠溶液络合钙、镁等干扰元素,稀土氢氧化物留存于沉淀中,沉淀经盐酸溶解进入待测液,从而将稀土元素与熔剂和基体元素分离。实验结果表明:标准溶液无需基体匹配,各稀土氧化物标准曲线的线性相关系数均不小于0.9999,检出限在0.0002%~0.0015%之间;按照实验方法分析实际样品中稀土氧化物的含量,测定结果的相对标准偏差(RSD,n=6)为2.0%~4.6%,回收率为85.2%~104.4%。本方法与电感耦合等离子体质谱法(ICP-MS)相比,两种方法的测定结果无显著性差异。  相似文献   

18.
近年来,着地质学科的研究需要,稀土元素的分析手段不断向深度发展。为了制作稀土球粒陨石标准化分布型武图,要求准确测定痕量稀土元素,同时还由于各种岩石的基体变化不一,造岩元素所产生的谱线干扰以及可变的背景干扰都给痕量稀土元素的测定带来困难,所以,一般都需要进行预处理,将岩石的主元素分离,并使稀土元素相对浓缩。  相似文献   

19.
离子吸附型稀土中离子相稀土的准确测定对稀土矿体资源评价具有重要意义。离子相稀土以羟基或水合羟基的形式吸附在黏土矿物上,可与强电解质(Mg~(2+)、NH_4~+等)交换解吸进入溶液。前人以硫酸铵为淋滤液,实现了离子相稀土的解吸、提取,但在溶液浓度、浸取过程等方面选择各异,淋滤浸取率(60%~90%)差异大,未形成高效、统一的浸取方法,不利于离子相稀土元素的精确测定。本文通过对比实验规范了硫酸铵淋滤离子相稀土的各项淋滤参数(固液比、硫酸铵浓度、样品最佳称样量、浸泡时间),减少了淋滤过程中离子相稀土的损失,浸取率达到88%~98%,进而利用ICP-MS测定离子相稀土分量。方法检出限为0. 05~5. 11 ng/g;三类岩性离子吸附型稀土样品的精密度为:火山岩1. 80%~10. 01%,变质岩1. 06%~7. 27%,沉积岩1. 72%~7. 58%。协作实验室的分析结果验证了本方法的可靠性和准确性。本方法操作简便,分析效率高,为建立相关的行业标准乃至国家标准奠定了基础。  相似文献   

20.
用高氯酸-氢氟酸-硝酸消解样品,样品中的难溶组分被有效浸取,电感耦合等离子体发射光谱法测定土壤样品中稀土元素及稀散元素等54种组分。通过筛选分析谱线、合理设置背景扣除位置及干扰元素校正系数,改善了光谱干扰。方法经国家一级土壤标准物质分析验证,结果与标准值吻合,相对标准偏差低于6.0%。方法可测组分多,试剂用量少,简便快速,劳动强度低,能够满足基体组成复杂的区域土壤地球化学调查样品分析的要求,也为其他地球化学样品中相关组分的分析提供借鉴。  相似文献   