Shape Factors for Permeability Tests in Boreholes and Piezometers   总被引:3,自引:0,他引:3  
  相似文献   

3.
4.
We extend Bouwer and Rice (1976) slug test theory to incorporate background head trends that may be important in incompressible material of low permeability k. The extension, which features a convolution integral of the background head, is closed form for linear trends. A sensitivity study suggests that a rising background head can diminish the head changes associated with a slug-out test and underestimate k if it is ignored, as does falling background trend with a slug-in test. A falling background head can reinforce slug-in test head change and, if ignored, can overestimate k, as does a rising background head with a slug-out test. The simple extension is verified by field tests in glacial till and stratified drift deposits in eastern Massachusetts.  相似文献   

5.
Interpretation of Slug and Packer Tests in Anisotropic Aquifers   总被引:5,自引:0,他引:5  
  相似文献   

6.
7.
8.
The accelerated production and replacement of new electrical and electronic equipment demonstrates a tendency for the proportional increase in the generation of e‐waste. Developing countries experience similar social and environmental consequences from this trend, which compounds the other challenges associated with the already poor solid waste management in these regions. Moreover, the dangerous composition of some e‐waste amplifies the problems related to managing these materials. This mini‐review presents a brief overview of e‐waste management in Brazil, including technical aspects, scientific studies, and the challenges ahead. With the Brazilian National Policy of Solid Waste already in place, technical and scientific studies endorse measures that range from incorporating the informal recycling sector into the e‐waste management sector to encouraging the expansion of the recycling industry. All such actions, combined with an intensified commitment of electronic equipment manufacturers to reverse logistics, can improve e‐waste management in Brazil.  相似文献   

9.
Evaluating the Volume of Porous Medium Investigated During Slug Tests   总被引:1,自引:0,他引:1  
  相似文献   

10.
Improving the Quality of Parameter Estimates Obtained from Slug Tests   总被引:2,自引:0,他引:2  
  相似文献   

11.
Slug testing is frequently employed to calculate aquifer transmissivity and hydraulic conductivity. The van der Kamp technique for interpreting slug test data which experience force-free water level oscillations is not routinely employed because it requires adjusting equations to match the observed well response data. This adjustment can be rapid and convenient when a commercial spreadsheet is employed.  相似文献   

12.
The majority of slug tests done at sites of shallow groundwater contamination are performed in wells screened across the water table and are affected by mechanisms beyond those considered in the standard slug‐test models. These additional mechanisms give rise to a number of practical issues that are yet to be fully resolved; four of these are addressed here. The wells in which slug tests are performed were rarely installed for that purpose, so the well design can result in problematic (small signal to noise ratio) test data. The suitability of a particular well design should thus always be assessed prior to field testing. In slug tests of short duration, it can be difficult to identify which portion of the test represents filter‐pack drainage and which represents formation response; application of a mass balance can help confirm that test phases have been correctly identified. A key parameter required for all slug test models is the casing radius. However, in this setting, the effective casing radius (borehole radius corrected for filter‐pack porosity), not the nominal well radius, is required; this effective radius is best estimated directly from test data. Finally, although conventional slug‐test models do not consider filter‐pack drainage, these models will yield reasonable hydraulic conductivity estimates when applied to the formation‐response phase of a test from an appropriately developed well.  相似文献   

13.
Slug tests are a widely used technique to estimate aquifer hydraulic parameters and the test data are generally interpreted with analytical solutions under various assumptions. However, these solutions are not convenient when slug tests are required to be analyzed in a three‐dimensional model for complex aquifer‐aquitard systems. In this study, equivalent well blocks (EWB) are proposed in numerical modeling of slug test data with MODFLOW. Multi‐well slug tests in partially penetrating wells with skin zones can be simulated. Accuracy of the numerical method is demonstrated by benchmarking with analytical solutions. The EWB method is applied in a case study on slug tests in aquitards in the Pearl River Delta, China.  相似文献   

14.
Forced gradient tracer tests between two boreholes can be used to study contaminant transport processes at the small field scale or investigate the transport properties of an aquifer. Full depth tests, in which tracer samples are collected just from the discharge of the abstraction borehole, often give rise to breakthrough curves with multiple peaks that are usually attributed to different flow paths through the aquifer that can rarely be identified from the test results alone. Tests in selected levels of the aquifer, such as those between packer‐isolated sections of the boreholes, are time consuming, expensive; and the identification of major transport pathways is not guaranteed. We present a method for simultaneously conducting multiple tracer tests covering the full depth of the boreholes, in which tracer sampling and monitoring is carried out by a novel multilevel sampling system allowing high frequency and cumulative sampling options. The method is applied to a tracer test using fluorescein conducted in the multilayered sandstone aquifer beneath the city of Birmingham, UK, producing six well‐defined tracer breakthrough curves.  相似文献   

15.
16.
17.
Transmissivity can be estimated by several well documented methods employing data from rising water level slug tests in wells. A very simple and relatively inexpensive system can be constructed to lower the water level in a well. Compressed air is injected through a sealed device called a well head manifold, which screws onto the casing top and contains an air pressure gauge, an air entry valve, a quick release valve and a multi-channel water level indicator or a pressure transducer. Either of the latter is lowered into the well prior to pressurization.
Compressed air is injected into the casing at a low rate through the manifold, depressing the water level a desired amount. After stabilization, the quick release valve is opened and the air pressure inside the casing is reduced to atmospheric pressure instantaneously; the water level then starts to rise. Successive elevations of the rising water level are determined with the indicator or transducer and their elapsed times from valve opening are recorded. Plots of water level recovery vs. time can then be used to estimate transmissivity by the published methods of Cooper, Bredehoeft and Papadopulos (1967), Ferris and Knowles (1954) and Hvorslev(1951).
All of the items used for construction, with the exception of the quick release valve, can be bought off the shelf. The valve can be easily constructed in a machine shop. The total cost of the device, exclusive of the transducer, should be less than $500.  相似文献   

18.
19.
The response of low‐ductility reinforced concrete (RC) frames, designed typically for a non‐seismic region, subjected to two frequencies of base excitations is studied. Five half‐scaled, two‐bay, two‐storey, RC frames, each approximately 5 m wide by 3.3 m high, were subjected to both horizontal and/or vertical base excitations with a frequency of 40 Hz as well as a lower frequency of about 4 Hz (close to the fundamental frequency) using a shake table. The imposed acceleration amplitude ranged from 0.2 to 1.2g. The test results showed that the response characteristics of the structures differed under high‐ and low‐frequency excitations. The frames were able to sustain high‐frequency excitations without damage but were inadequate for low‐frequency excitations, even though the frames exhibited some ductility. Linear‐elastic time‐history analysis can predict reasonably well the structural response under high‐frequency excitations. As the frames were not designed for seismic loads, the reinforcement detailing may not have been adequate, based on the crack pattern observed. The effect of vertical excitation can cause significant additional forces in the columns and moment reversals in the beams. The ‘strong‐column, weak‐beam’ approach for lateral load RC frame design is supported by experimental observations. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

20.
Multilevel piezometers are cost-effective monitoring devices for determining the three-dimensional distribution of solutes in ground water. Construction includes flexible tubing (plastic or Teflon®). Their sampling is subject to a number of'potential biases, particularly: (1) losses of volatile organic solutes via volatilization, (2) sorption onto the flexible tubing of the piezometers, (3) leaching of organics from this tubing, and (4) collection of unrepresentative samples due to inadequate piezometer flushing. It is shown that these biases are minimal or are easily controlled in most situations.
Another source of bias has been recognized. Organic solutes present in ground water above the screened level can penetrate the flexible plastic or Teflon tubing and contaminate the sampled water being drawn through this tubing. Laboratory tests and field results indicate this transmission causes low organic contaminant concentrations to be erroneously attributed to ground water which is free of such contaminants. The transmitted organics apparently desorb from the plastic tubing during flushing of even 40 piezometer volumes.
Recognition of this transmission problem provides for a better interpretation of existing organic contaminant distribution data. Caution is advised when considering the use of these monitoring devices in organic solute contaminant studies.  相似文献   