首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Experimental proof is provided of an unconventional seismic design concept, which is based on deliberately underdesigning shallow foundations to promote intense rocking oscillations and thereby to dramatically improve the seismic resilience of structures. Termed rocking isolation, this new seismic design philosophy is investigated through a series of dynamic centrifuge experiments on properly scaled models of a modern reinforced concrete (RC) bridge pier. The experimental method reproduces the nonlinear and inelastic response of both the soil‐footing interface and the structure. To this end, a novel scale model RC (1:50 scale) that simulates reasonably well the elastic response and the failure of prototype RC elements is utilized, along with realistic representation of the soil behavior in a geotechnical centrifuge. A variety of seismic ground motions are considered as excitations. They result in consistent demonstrably beneficial performance of the rocking‐isolated pier in comparison with the one designed conventionally. Seismic demand is reduced in terms of both inertial load and deck drift. Furthermore, foundation uplifting has a self‐centering potential, whereas soil yielding is shown to provide a particularly effective energy dissipation mechanism, exhibiting significant resistance to cumulative damage. Thanks to such mechanisms, the rocking pier survived, with no signs of structural distress, a deleterious sequence of seismic motions that caused collapse of the conventionally designed pier. © 2014 The Authors Earthquake Engineering & Structural Dynamics Published by John Wiley & Sons Ltd.  相似文献   

2.
第四纪地层中断层同震错动行为的离心机试验研究   总被引:3,自引:0,他引:3       下载免费PDF全文
运用试验地球物理学的原理和方法来研究认识当地震发生时在第四纪地层中断层同震错动行为的有关特征,为减轻地震灾害相关问题进行基础研究.原创了在试验模型中预制断层的方法来模拟第四纪地层中存在的断层,用离心机模拟试验研究第四纪地层中不同活动年代、不同上断点深度断层的同震错动行为,特别是地表破坏(地表形变和破裂)特征,取得了新的明确认识,给出了不同场地条件下建设工程应对地震地表破裂造成直接破坏的避让距离.因此这项工作不但有着基础科研意义,而且具有对工程建设防震减灾的实际应用意义.  相似文献   

3.
水下爆破对大坝影响的离心模拟试验研究   总被引:4,自引:0,他引:4  
由于离心机能够在原型应力条件下模拟爆破对大坝的影响。本文使用中国水利水电科学研究院研制的离心模拟爆破系统,在不同重力加速度之下研究了在不同水深,距坝面不同距离的情况下雷管爆破对于大坝的影响。  相似文献   

4.
The investigation on the seismic behavior of dams becomes crucial but is limited to lack of experimental or field data. This paper aims to experimentally simulate two major dam types of earth-core rock-fill dam and concrete-faced rock-fill dam by dynamic centrifuge tests to investigate the seismic response of the dam. A series of staged centrifuge tests was performed by applying real earthquake records from 0.05 to 0.5g. The distributions of amplification ratio differed depending on the magnitude of earthquake loading and the zoning condition. The amplification ratio at the crest increased in the bedrock acceleration that exceeds 0.3g and strongly influenced by the loosening behavior of the upper part. The residual settlements and horizontal displacement at the dam crest were small. Shallow surface sliding was dominant failure. The maximum tensile stress on the face slab by dynamic loading occurred at a height of around 4/5 near the upstream water level. Finally, two-dimensional numerical simulations were performed in an effort to simulate the centrifuge models. The centrifuge tests and numerical analysis obtained mostly comparable results, thus confirming that centrifuge modeling reasonably simulates the seismic behavior of dams.  相似文献   

5.
总结了土工动力离心模型试验在边坡的地震响应、动力破坏机理、液化大变形和土与结构物动力相互作用等研究中的应用现状,提出了目前边坡动力模型试验中存在的问题,以及今后的发展方向。  相似文献   

6.
Evaluation of pile foundation response to lateral spreading   总被引:7,自引:0,他引:7  
The effects of liquefaction on deep foundations are very damaging and costly, and they keep recurring in many earthquakes. The first part of the paper reviews the field experience of deep foundations affected by liquefaction during earthquakes in the last few decades, as well as the main lessons learned. The second part of the paper presents results of physical modeling of deep foundations in the presence of liquefaction conducted by the authors and others at the 100g-ton RPI centrifuge. In the last decade centrifuge modeling has been identified as a key tool to identify and quantify mechanisms, calibrate analyses and evaluate retrofitting strategies for pile foundations. Results are presented of centrifuge models of instrumented pile foundations subjected to lateral spreading, including single pile and pile groups, 2- and 3-layer soil profiles, mass and stiffening elements above ground to incorporate the effect of the superstructure, and evaluation of proposed retrofitting strategies. Interpretations of these centrifuge experiments and their relation to field observations and soil properties.  相似文献   

7.
The use of a single-bowl continuous-flow centrifuge (CFC, Sharples-Pennwalt Model AS-12) for dewatering suspended sediment from large volumes of river water is evaluated. Sediment-recovery efficiency of 86-91 per cent is comparable to that of other types of CFC units. The recovery efficiency is limited by the particle-size distribution of the feed water and by the limiting particle diameter that is retained in the centrifuge bowl. The limiting particle diameter, using the parameters for this study (bowl radius = 10.5cm; bowl length = 71.1 cm; rotational velocity = 16000 r min?1; flow rate = 2 L min?1, and an assumed hydrated particle density = 1.7 gm cm?3), is 370 nm. There seems to be no particle-size fractionation within the centrifuge bowl—the median particle size was the same at the top as at the bottom. Particle electrophoretic mobility plays some role in fractionation of particles within the centrifuge. The mobility ranged from ?1.19 to ?2.01 × 10?8 m2 V?1 s?1, which is typical of clays coated with organic matter, the charge of which is partially neutralized by divalent cations and iron. Contamination by trace metals and organics is minimized by coating all surfaces that come in contact with the sample with either FEP or PFA Teflon and using a removable FEP Teflon liner in the centrifuge bowl. Because of the physical and chemical factors affecting particle fractionation within the centrifuge, care must be exercised in interpreting the environmental consequences of particles collected by continuous-flow centrifugation.  相似文献   

8.
A method for collecting suspended sediment samples has been developed that pumps a discharge-weighted volume of water from fixed depths at four to 40 locations across a river and separates the suspended sediment in the sample using a continuous-flow centrifuge. The efficacy of the method is evaluated by comparing the particle size distributions of sediment collected by the discharge-weighted pumping method with the particle size distributions of sediment collected by depth integration and separated by gravitational settling. The pumping method was found to undersample the suspended sand sized particles (> 63 μm) but to collect a representative sample of the suspended silt and clay sized particles (< 63 μm). The centrifuge separated the silt and clay sized particles (< 63 μm) into three fractions. Based on the average results of processing 17 samples from the Mississippi River and several of its large tributaries in 1990, about 10% of the silt and clay sized material was trapped in a centrifuge bowl-bottom sealing unit containing the nozzle and consisted of mostly medium and coarse silt from 16 to 63 μm. About 74% was retained on a Teflon liner in the centrifuge bowl and consisted of sizes from 0–1 to 63 μm. About 9% was discharged from the centrifuge in the effluent and was finer than 0–1 μm. About 7% was lost during the processes of removing the wet sediment fractions from the centrifuge, drying and weighing. The success of the discharge-weighted pumping method depends on how homogeneously the silt and clay sized particles (< 63 μm) are distributed in the vertical direction in the river. The degree of homogeneity depends on the composition and degree of aggregation of the suspended sediment particles.  相似文献   

9.
This paper outlines the results of an experimental program carried out on centrifuge models of cantilevered and propped retaining walls embedded in saturated sand. The main aim of the paper is to investigate the dynamic response of these structures when the foundation soil is saturated by measuring the accelerations and pore pressures in the soil, displacements and bending moment of the walls. A comparison among tests with different geometrical configurations and relative density of the soil is presented. The centrifuge models were subjected to dynamic loading in the form of sinusoidal accelerations applied at the base of the models. This paper also presents data from pressure sensors used to measure total earth pressure on the walls. Furthermore, these results are compared with previous dynamic centrifuge tests on flexible retaining walls in dry sand.  相似文献   

10.
1 Introduction Soil and soil-structure systems exhibit complex response patterns during earthquake-induced liquefaction. These patterns depend on geotechnical properties, in-situ stress conditions and interaction with subsurface structural elements. Seismic records of full- scale systems during case histories provide a valuable source of information on the associated response mechanisms. However, the response of these systems is commonly monitored at sparsely distributed locations only, mostly…  相似文献   

11.
Lateral spreads are complex dynamic phenomena that are challenging to represent numerically. In this paper numerical models are developed and calibrated using the displacement, acceleration, and pore water pressure time histories recorded in a free-field lateral spreading centrifuge test. The calibrated numerical model then is used to predict another free-field lateral spreading centrifuge test using the same soil profile but different input acceleration time history. The computed response shows good agreement with the centrifuge test measurements. This paper demonstrates that even in a large strain problem, such as lateral spreading, small strain damping plays an important role in numerical simulation results; it also shows the need to have pressure dependent dilation parameters in the employed soil constitutive model implemented in order to simultaneously reproduce measurements of pore water pressure, acceleration and lateral displacement.  相似文献   

12.
An analytical model is developed to analyze the seismic response of gravity walls retaining and founded on dry sand, with special emphasis on tilting behaviour. A well verified two-dimensional finite element code is used for this purpose. The analytical model is verified by comparing predictions to results from three dynamic centrifuge tests, with satisfactory agreement. Moreover, sensitivity analyses are carried out for one of the centrifuge test conditions to understand how the results would change if the boundary conditions and rotational stiffness of the wall were changed.  相似文献   

13.
The present study aims to obtain p-y curves(Winkler spring properties for lateral pile-soil interaction) for liquefied soil from 12 comprehensive centrifuge test cases where pile groups were embedded in liquefiable soil. The p-y curve for fully liquefied soil is back-calculated from the dynamic centrifuge test data using a numerical procedure from the recorded soil response and strain records from the instrumented pile. The p-y curves were obtained for two ground conditions:(a) lateral spreading of liquefied soil, and(b) liquefied soil in level ground. These ground conditions are simulated in the model by having collapsing and non-collapsing intermittent boundaries, which are modelled as quay walls. The p-y curves back-calculated from the centrifuge tests are compared with representative reduced API p-y curves for liquefied soils(known as p-multiplier). The response of p-y curves at full liquefaction is presented and critical observations of lateral pile-soil interaction are discussed. Based on the results of these model tests, guidance for the construction of p-y curves for use in engineering practice is also provided.  相似文献   

14.
When designing buried structures using a performance-based framework, it is important to estimate their uplift displacement. A simplified method is proposed for predicting the uplift displacement of a hollow cylinder structure buried in shallow backfill based on the equilibrium of vertical forces acting on the structure during earthquakes. However, this method only provides the maximum value, which frequently is overestimated in practical applications. To offset this limitation, first, the uplift behavior of buried hollow cylinder structures subjected to strong earthquake motions was simulated. Then, two-dimensional effective stress analyses based on the multiple shear mechanism for soil were conducted, and the results were compared with the centrifuge test data. The soil parameters were evaluated based on laboratory test results. The seismic response data from 20 g centrifuge tests were analyzed, and the results were generally consistent with the results of centrifuge model tests. In particular, the effective stress model showed a reasonable ability to reproduce the varying degrees of uplift displacement depending on the geotechnical conditions of trench soils adjacent to the hollow cylinder structures buried in shallow ground.  相似文献   

15.
Many surviving ancient monuments are freestanding stone masonry structures, which appear to be vulnerable to horizontal dynamic loads such as earthquakes. However, such structures have stood for thousands of years despite numerous historic earthquakes. This study proposes a scaled-down dynamic centrifuge modelling test to study how these masonry structures resist seismic loading. The test is proposed for seismic risk assessments to evaluate risk of damage from a future seismic event. The seismic behaviour of a 3-storey, freestanding stone block structure has been modelled and tested within a centrifuge. Models were made at 3 different scales and dynamic tests were conducted using different centrifugal acceleration fields so that the behaviours could be transformed to an equivalent full-scale prototype and compared. Data from 2 earthquakes and a sweeping signal were used to simulate the effects of earthquake ground motion within the centrifuge. The acceleration and frequency responses at each storey height of the model were recorded in different centrifugal acceleration fields. Similar behaviours appeared when the results of the small-scale models were transformed to a full-size prototype scale. This confirms that the seismic behaviour of stone masonry structures can be predicted using scaled-down models.  相似文献   

16.
Understanding the soil–structure interaction (SSI) mechanism is crucial in the seismic design of nuclear power plant (NPP) containment systems. Although the numerical analysis method is generally used in seismic design, there is a need for experimental verification for the reliable estimation of SSI behavior. In this study a dynamic centrifuge test was performed to simulate the SSI behavior of a Hualien large-scale seismic test (LSST) during the Chi-Chi earthquake. To simulate the soil profile and dynamic soil properties of the Hualien site, a series of resonant column (RC) tests was performed to determine the model soil preparation conditions, such as the compaction density and the ratio of soil–gravel contents. The variations in the shear wave velocity (VS) profiles of the sand, gravel, and backfill layers in the model were estimated using the RC test results. During the centrifuge test, the VS profiles of the model were evaluated using in-flight bender element tests and compared with the in-situ VS profile at Hualien. The containment building model was modeled using aluminum and the proper scaling laws. A series of dynamic centrifuge tests was performed with a 1/50 scale model using the base motion recorded during the Chi-Chi-earthquake. In the soil layer and foundation level, the centrifuge test results were similar to the LSST data in both the time and frequency domains, but there were differences in the structure owing to the complex structural response as well as the material damping difference between the concrete in the prototype and aluminum in the model. In addition, as the input base motion amplitude was increased to a maximum value of 0.4g (prototype scale), the responses of the soil and containment model were measured. This study shows the potential of utilizing dynamic centrifuge tests as an experimental modeling tool for site specific SSI analyses of soil–foundation–NPP containment system.  相似文献   

17.
Based on a centrifuge model test and distinct element method(DEM), this study provides new insights into the uplift response of a shallow-buried structure and the liquefaction mechanism for saturated sand around the structure under seismic action. In the centrifuge test, a high-speed microscopic camera was installed in the structure model, by which the movements of particles around the structure were monitored. Then, a two-dimensional digital image processing technology was used to analyze the microstructure of saturated sand during the shaking event. Herein, a numerical simulation of the centrifuge experiment was conducted using a two-phase(solid and fl uid) fully coupled distinct element code. This code incorporates a particle-fl uid coupling model by means of a "fi xed coarse-grid" fl uid scheme in PFC3D(Particle Flow Code in Three Dimensions), with the modeling parameters partially calibrated based on earlier studies. The physical and numerical models both indicate the uplifts of the shallow-buried structure and the sharp rise in excess pore pressure. The corresponding micro-scale responses and explanations are provided. Overall, the uplift response of an underground structure and the occurrence of liquefaction in saturated sand are predicted successfully by DEM modeling. However, the dynamic responses during the shaking cannot be modeled accurately due to the restricted computer power.  相似文献   

18.
This study attempts to propose dynamic centrifuge model tests as a method of seismic risk assessment in order to discover how stone architectural heritages with masonry structures have endured seismic load, and whether there is any possibility of future earthquake damage. Dynamic centrifuge tests have been conducted for one fifteenth scale models of Seok-ga-tap and the five-storey stone pagoda of Jeongnimsa temple site, which are Korean representative stone pagodas. In order to make input motions of the earthquake simulator, site investigation and site-specific response analysis have been performed. The models of two stone pagodas, which have the same number of pieces with the real structures, have been produced and the dynamic centrifuge tests have been conducted for the model pagodas. Accelerometers were attached at different heights of the pagoda. The measured acceleration records and frequency responses were analysed during dynamic centrifuge test. Two real earthquake records, Hachinohe and Ofunato earthquakes and a sweeping signal with ranged frequency were utilised for input motions of dynamic centrifuge tests to evaluate the behaviour of the stone pagodas. For Seok-ga-tap models, it was observed that acceleration tends to be amplified with height. The third floor body shows at most 2.5 amplification of acceleration in comparison to the surface ground. The amplification was at a frequency of 3.83 Hz and it was considered as the natural frequency of the pagoda. For the five-storey stone pagoda, the seismic wave energy significantly reduced while it passed the first body floor, and then the peak acceleration was gradually amplified upwards. It was found that the pagodas did not collapse when the peak acceleration of ground surface was raised to 0.4 g. Given that the maximum design seismic acceleration specified in Korean seismic design guide is 0.22 g and the amplification ratio of peak acceleration in the supporting ground of the pagodas ranges from 1.45 to 1.74, it can be shown that the two pagodas are stable against 2400-year return period earthquake level, and have excellent seismic performance.  相似文献   

19.
砂土自由场地震响应的离心机试验研究   总被引:3,自引:1,他引:2  
离心机模型试验是研究岩土地震工程问题的有效手段。本文使用层状剪切箱,通过干落法制备了均匀的砂土模型,进行了离心机振动试验;观测了振动过程中孔隙水压力的发展,土体的加速度响应、侧向变形以及竖向沉降。结果表明,土体的运动和变形与孔隙水压力的发展密切相关,但离心机中的试验现象和现场观测的现象存在显著区别。研究结果增强了对振动过程中土-水之间相互作用机理的理解,同时为自由场地震响应分析方法的验证提供了基础数据。  相似文献   

20.
为了确定框架结构弹塑性时程分析时输入地震动记录的调幅方法,本文利用一个1/40比例的框架结构振动台试验研究了四种地震动记录调幅方法的适用性。利用四种地震动记录调幅方法对20条地震动记录调幅,通过振动台依次输入不同周期的框架结构中,通过分析结构顶层的层间位移角和最大加速度两个参数的变异系数,确定最适宜此种结构体系的地震动记录调幅方法。研究表明,当结构的基本周期可以准确确定时,利用S_a(T_1)调幅方法得到的地震动记录引起结构响应的离散程度最小;当结构的基本周期不确定时,利用MIV调幅方法得到的地震动记录引起结构响应的离散程度最小;当周期有30%的变化时,ASCE调幅方法引起结构的最大加速度的变异系数波动不大,相对比较稳定;无论何时PGA调幅方法得到的变异系数都是最大,表明此法得到的离散程度最大。建议在对框架结构进行时程分析时,对于确定性周期的结构采用S_a(T_1)调幅方法,对于不确定性周期的结构采用MIV调幅方法,ASCE和PGA调幅方法不宜采用。  相似文献   