共查询到18条相似文献,搜索用时 78 毫秒
1.
2.
研究了利用二苯硫脲-甲基异丁酮泡塑振荡吸附富集Au、Ag的条件,并采用金试剂-TBP液珠萃取比色法测定地质样品中的金、银。方法的检出限:Au为0.5×10-9,Ag为5×10-9。 相似文献
3.
二苯硫脲—甲基异丁酮泡塑富集分离液珠萃取比色法测定地质样品中的金,银 总被引:1,自引:0,他引:1
研究了利用二苯硫脲-甲基异丁酮泡塑振荡吸附富集Au,Ag的条件,并采用金试剂-TBP液珠萃取比色法测定地质样品中的金,银,方法的检出限:Au为0.5×10^-9,Ag为5×10^-9。 相似文献
4.
黄原酯棉(CCX)是金的良好的吸附体,本文将吸附了金的CCX用灰化法解脱。操作简单快速、成本低,灰化时无臭味、残渣少。浸取液用三正辛胺-TBP(1:3)混合萃取-金试剂液珠比色法测定Au,其液珠凝聚好,灵敏度高,选择性和稳定性都比单用TBP有所提高。方法的测定范围0.0005-xx g/t、配备金的野外快速分析箱,可作现场分析。 相似文献
5.
二苯硫脲泡塑富集-原子吸收光谱法连续测定化探样品中金和银 总被引:1,自引:2,他引:1
传统的发射光谱、化学光谱、泡塑富集分离-原子吸收光谱法测定化探样品中的金和银,分析结果不稳定,效率低。本研究提出用50%的王水分解化探样品,负载二苯硫脲泡塑吸附金银,石墨炉和火焰原子吸收光谱法对金和银进行联合测定。在二苯硫脲浓度、吸附酸度、吸附温度、振荡时间等优化的实验条件下,金和银的回收率分别达到97.9%和98.8%,检出限为0.25 ng/g和0.038 μg/g,准确度(RE,n=9)为2.0%~14.0%和7.7%~13.3%,精密度(RSD,n=9)为3.1%~12.4%和5.1%~13.2%。经国家标准物质分析验证,测定值与标准值基本相符。该方法实现了在同一份溶液中同时测定金和银,与现行的石墨炉原子吸收光谱测定金、发射光谱测定银的方法相比,称样量达到10 g,样品的代表性显著增加,提高了准确度和精密度,简化了金银分析的程序,化学试剂用量少,分析成本低。 相似文献
6.
快速测定矿石中的银:二苯硫脲泡塑富集分离硫代米Chi酮—洗洁精全差示光度? 总被引:2,自引:0,他引:2
提出了一个二苯硫包塑富集分离硫代米Chi酮-洗洁精全差示光度法快速测定矿石中银的新方法。该法简单快速,准确度高,选择性好,易于操作,适用性好,易于操作,适用于野外和中小型矿山化验室快速测定矿石中的银。 相似文献
7.
甲基异丁基酮负载泡塑富集—原子吸收测定岩矿中痕量金银铊镉 总被引:4,自引:4,他引:4
研究了多种负载泡塑对Au、Ag、Ti、Cd的富集行为。提出了在HCI-KI-抗坏血酸介质中用甲基异丁基酮(MIBK)负载泡塑同时萃取,然后用2%硫脲-1%HCl解脱的富集方法,并采用火焰原子吸收连续测定地质样品中痕量Au、Ag、Tl和Cd,方法的测定下限(μg/g)分别为:0.2g、0.05、0.20和0.04。 相似文献
8.
提出了一个二苯硫脲泡塑富集分离硫代米蚩酮-洗洁精全差示光度法快速测定矿石中银的新方法。该法简单快速,准确度高,选择性好,易于操作,适用于野外和中小型矿山化验室快速测定矿石中的银。 相似文献
9.
目前在野外进行快速测定化探样品中微量铜的方法还不多见,本文报道了一个野外快速测定化探样品微量铜的新方法,该法基于在pH5乙酸缓冲溶液中,铜与5-Br-PADAP形成的有色络合物能够被磷酯原黄丁(TBP)的液珠萃取,形成的液珠灵敏度高,0-0.1ug之间的色阶可明显辨出,采用三酸酯棉富集分离铜^[1],灰化法解脱,称样0.5g,测定下限为每毫升0.2ug铜,该法操作简单快速,不需要特殊的仪器和通风设备,适用于野外进行化探样品中数量铜的快速测定。 相似文献
10.
在三苯磷-甲基异丁基酮萃取火焰原子吸收法测定化探样品的痕量银方法的基础上,用碘化钾代替三苯磷作为配合剂测定微量银,结果表明在15%的盐酸介质中,碘化钾溶液作配合剂,用MIBK溶液萃取效果甚佳,而且克服了三苯磷的有毒、成本高、不易保存、需现用现配等缺点。本法的检出限为0.010×10^-6,最佳测定范围0.015×10^-6 ̄5.000×10^-6。 相似文献
11.
12.
泡塑富集-硫代米蚩酮萃取微珠比色法在野外测金的应用 总被引:5,自引:0,他引:5
在野外交通不便和无电力条件下,应用泡塑富集-硫代米蚩酮微珠萃取比色法,实现了5~1200ng/g金的测定,结果与室内化学光谱法比较,无明金样品的相对误差可控制在60%以内,含明金样品的相对误差基本在100%~500%,可以满足化探找金及异常查证的要求。方法能有效地指导化探找金工作。 相似文献
13.
Marc Constantin 《Geostandards and Geoanalytical Research》2009,33(1):115-132
New concentrations for Au, Ir and Ag obtained by instrumental neutron activation analysis are presented for seventy geochemical reference materials. Results in agreement with literature values for Au and Ir down to concentrations of a few ng g−1 were obtained. For Au and Ir concentrations above 10 ng g−1 , the repeatability of replicate analyses of reference materials was mostly better than 10%. For concentrations between 1 and 10 ng g−1 the RSD for Ir was 10–30%, whereas for Au it was higher and more variable (20–50%). In addition, concentrations for Cd and Hg are presented for some of the same reference materials. The high RSD at relatively high concentrations seen in gold for some RMs (e.g., WMG-1, WMS-1) did not exist for Ir and suggests homogeneity for this platinum-group element at the sub-sample size used in this study. For the following eight RMs, mostly ultramafic rocks (CHR-Pt+, OREAS-13P, OREAS-14P, PCC-1, UMT-1, WMG-1, WMS-1, WPR-1), Ir measurements agreed within ± 10% of mostly certified or recommended concentrations, which ranged from 2 ng g−1 to 6 μg g−1 . For the reference material UB-N, iridium concentration compared favourably to published results obtained by isotope dilution ICP-MS methods and a previously unrecognised heterogeneity is inferred for Au, Hg and Sb, but not for the other measured elements. 相似文献
14.
泡沫塑料分离富集原子吸收法测定氰化液中金和银 总被引:1,自引:0,他引:1
研究了装有聚醚型泡沫塑料和三苯基膦负载聚醚型泡沫塑料的吸附柱对Au,Ag的分离富集的条件,并应用于氰化液、解吸液和电解液中Au和Ag测定中的预富集,Au和Ag的回收率均>98%。对含Au量为0.91μg/ml,含Ag量0.36μg/ml的试样,经过10次测定,其相对标准偏差分别为1.22%和2.31%。 相似文献
15.
研究了碘化钾-甲基异丁基甲酮(KI—MIBK)萃取-火焰原子吸收分光光度法连续测定地球化学样品中痕量银、镉和铊的主要条件。通过对火焰原子吸收分光光度计气路控制系统及雾化器的改进,较大地改善了萃取-火焰原子吸收分光光度法测定银、镉和铊的稳定性和灵敏度。选择萃取酸度为1.2mol/L HCl、水相和有机相体积配比为3:1~4:1,方法精密度(RSD,n=12)为Ag4.5%~9.6%、Cd1.5%~7.9%、T14.5%~5.4%,检出限(3s)为Ag0.004μg/g、Cd0.007μg/g、T10.011μg/g,符合多目标地球化学调查样品测试及质量监控要求。用国家一级标准物质和密码组合标准物质进行验证,测试结果令人满意。 相似文献
16.
X射线荧光靶线内标法测定金首饰中的银 总被引:7,自引:1,他引:7
采用X射线荧光靶线内标法测定黄金饰品中银含量,当w(Ag)<10%时,测定的标准偏差小于001%,测量平均值与标准值的偏差亦小于001%;当w(Ag)<8%时,测定的标准偏差小于004%,测量平均值与标准值的偏差小于007%。方法能较好地补偿了表面形状对测定结果的影响,适用w(Au)>92%的饰品中银的测定 相似文献
17.
试样经焙烧、王水分解后,在8%的王水介质中,MIBK负载泡塑吸附[AuCl_4]~-。灰化吸附泡塑或硫脲溶液解脱,用中子活化法测定Au。取10g样品,可测定0.000x~xxμg/g的Au。用于金标样的定值,具有良好的精密度和准确度。 相似文献
18.
泡塑分离冷原子荧光测定金矿中微量汞 总被引:2,自引:0,他引:2
冷蒸气原子荧光测Hg,Au的最大允许量为0.5μg。一些金矿样品中Au的含量较高,在分析中如不分离Au而直接测Hg,将产生严重负干扰。本文试验表明:在5%~15%的王水介质中,小于10μg量的Hg不被泡塑吸附;500μgAu被定量吸附,同时被吸附的有Sb、Tl等元素。Se、Te的干扰用K_2Cr_2O_7氧化消除。本法操作简便、快速,分离效果好,成功地应用于金矿样品中Hg的测定。 相似文献