首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 921 毫秒
1.
史鹏飞  吴斌 《地震学刊》2009,(3):300-305
对拟负刚度阻尼减振结构的动力特性与减振效果进行了研究。首先,证明了采用拟负刚度控制方法时,结构响应与外荷载之间满足齐次性;其次,对拟负刚度阻尼减振结构的加速度放大系数和位移放大系数进行了研究,并与粘滞阻尼减振结构的加速度放大系数和位移放大系数进行了比较;最后,对地震荷栽作用下拟负刚度阻尼减振结构的减振效果进行了分析。研究结果表明:当外荷载与结构的频率比大于1或结构的周期较长时,拟负刚度控制对结构绝对加速度的控制效果要好于粘滞阻尼减振结构的控制效果,对结构位移的控制效果要差于粘滞阻尼减振结构的控制效果。  相似文献   

2.
Viscous fluid dampers have proved to be effective in suppressing unwanted vibrations in a range of engineering structures. When dampers are fitted in a structure, a brace is typically used to attach them to the main structure. The stiffness of this brace can significantly alter the effectiveness of the damper, and in structures with multiple dampers, this can be a complex scenario to model. In this paper, we demonstrate that the effects of the brace compliance on the damper performance can be modelled by way of a first‐order filter. We use this result to formulate a procedure that calculates the stiffness required by the supporting brace to provide a specified effectiveness of the damping action. The proposed procedure assumes that viscous dampers have been sized in a previous design step based on any optimal methodology in which, as is usually the case, the presence of supporting braces and their dynamic effects were neglected. Firstly considering a one degree‐of‐freedom system, we show that the proposed method ensures a desired level of damper efficiency for all frequencies within a selected bandwidth. Then the analysis is extended to the case of multi‐degree‐of‐freedom systems to show that the design criteria can be applied in a straightforward and successful manner to more complex structures. © 2014 The Authors. Earthquake Engineering & Structural Dynamics published by John Wiley & Sons Ltd.  相似文献   

3.
This paper presents a direct displacement-based design procedure for seismic retrofit of existing buildings using nonlinear viscous dampers according to equivalent linear systems. Unlike conventional methods, the equivalent linear viscous damping provided by the nonlinear viscous dampers is derived based on the assumption that the average energy dissipated between the linear and the nonlinear viscous dampers is equal. Also, the equivalent period and viscous damping for the equivalent linear systems which are used for representing the behavior of bare frames (the buildings without dampers) are derived from the concept of average storage energy and average dissipated energy, respectively. It is shown from nonlinear time-history analyses that the nonlinear action of the retrofitted structures can be reasonably captured by the presented direct displacement-based procedure.  相似文献   

4.
Previous studies have demonstrated the good performance of friction dampers in symmetric frame structures subjected to earthquake excitation. This paper examines their effectiveness in asymmetric structures where lateral-torsional coupling characterizes the behaviour. A parametric study is first performed employing an idealized single-storey structure; this is followed by the example of a three-dimensional 5-storey prototype structure equipped with friction dampers. The parametric results show that it is necessary to tune the friction damped braces with respect to both the stiffness of the braces and the slip load of the devices. For properly tuned structures, maximum response for all magnitudes of eccentricity between the centres of stiffness and mass is reduced to levels equal to or less than that of the corresponding symmetric structure. Compared to this prediction, the prototype structure with friction damped bracing exhibits the desired improvement in performance; namely, the devices slip at all storey levels while the frames remain elastic.  相似文献   

5.
阻尼器是一种效果良好的减震装置,将阻尼器安装于结构中能够适时为结构体系提供阻尼力,从而减小地震作用对结构的破坏。黏滞阻尼器对振动的反应比较敏感,在结构受到较小振动时就可以发挥其减震效果,其阻尼力会随着振动周期和使用状态温度的不同而变化。当地震发生时,安装在结构中的阻尼器会消减地震作用,降低传导到主结构体系的地震能量,减小结构相对位移。本文介绍了黏滞阻尼器的工作原理和安装有黏滞阻尼器的结构体系的阻尼比的计算方法,对减震结构的减震效果的评析方法做出探讨,并以一安装有黏滞阻尼器的台湾某既有钢框架结构为例,分析了(1)该结构在遭受地震作用时的地震反应;(2)该结构体系在不同地震作用水平时的阻尼比,包括主体结构阻尼比和黏滞阻尼器阻尼比;(3)结构安装黏滞阻尼器后的减震效果。实例对本文的减震评析方法和减震效果进行了说明和分析,计算及分析结果表明利用黏滞阻尼器加固既有结构能够取得较好的减震效果,本文所提减震效果评析方法是一种实用有效的评析方法,对类似工程的减震评析具有一定的参考价值。  相似文献   

6.
非线性黏滞阻尼减震结构基于位移的设计方法   总被引:1,自引:0,他引:1  
结合我国抗震设计规范,提出非线性黏滞阻尼减震结构基于位移的设计方法.根据减震结构的特点,将其性能划分为使用良好、人身安全和防止倒塌3个水平,并用层间位移角限值予以量化;以简化的方法计算非线性黏滞阻尼器的等效阻尼比.在此基础上将结构转化为等效单自由度体系,利用基于位移的设计方法对非线性黏滞阻尼减震结构进行设计,通过算例,介绍用该方法对框架结构进行非线性黏滞阻尼减震设计的设计过程.实例分析表明,提出的非线性黏滞阻尼减震结构基于位移的设计方法是可行的,并且与时程分析得出的平均结果吻合较好,而且该方法简单实用,便于操作,能够控制减震结构在不同强度水准地震作用下的性能.  相似文献   

7.
本文首先介绍了一幢安装了粘滞阻尼器的复杂体型高层方钢管混凝土框架结构的1/15缩尺模型的模拟地震振动台试验结果;在此基础上,建立了梁、柱构件的多弹簧模型并组建了整体结构的计算分析模型,运用此计算模型首先对试验模型结构进行了动力弹塑性时程分析,计算结果和试验结果吻合较好,验证了计算模型的正确性;最后,以同样方法对原型结构进行了计算分析,并结合试验结果研究探讨了此结构的抗震性能和阻尼器的消能减震效果。结果表明:该结构未出现明显的薄弱层,能够满足规范的抗震设防要求,阻尼器发挥了一定的消能减震效果,进一步提高了结构的抗震性能。  相似文献   

8.
通过钢-混凝土组合结构形式及在雀替位置处设置黏滞阻尼器,可提升仿古建筑枋-柱节点的力学性能。为研究其力学性能,共设计3个试件,包括2个附设黏滞阻尼器的试件及1个未附设黏滞阻尼器的对比试件,进行快速往复加载试验,分析加载全过程中试件的破坏特性及破坏机制,对其力学特性关键指标进行对比分析,包括恢复力特征曲线、骨架曲线、延性及刚度变化等。试验结果显示:采用钢-混凝土组合结构形式的仿古建筑双枋-柱节点力学性能得到一定幅度的提高;结构破坏时形成梁铰机制,符合抗震设计要求;在阑额与柱连接处设置黏滞阻尼器能有效提升节点的变形性能及承载能力,并在一定程度上抑制试件的刚度退化速率。总体上,结构整体抗震性能有大幅提高。  相似文献   

9.
非线性粘滞阻尼器消能结构减振效果分析   总被引:5,自引:1,他引:4  
应用并完善了非线性粘滞阻尼器消能结构地震反应预测的反应谱方法,通过与时程分析计算结果对比证明了方法的可行性。利用本方法研究了支撑刚度及阻尼器参数对非线性粘滞阻尼器减振效果的影响。通过数值分析,给出了位移降低率达到最佳时支撑刚度取值的建议式。提出了为保证剪力降低率不大于1时非线性粘滞阻尼器参数的控制方法。  相似文献   

10.
本文通过Maxwell模型模拟的黏滞阻尼器连接的2种不同相邻结构的地震反应分析,对阻尼器设置的位置和阻尼参数进行了同时优化。在El Centro波、Tianjin波和Taft波3种较典型的地震动作用下,分别对不同质量比和不同刚度比的主、子结构在无阻尼和有阻尼情况下进行了地震反应分析,并以主结构的顶层最大相对位移最小作为优化目标,寻求出最优的阻尼器摆放位置以及对应的最优阻尼系数。结果显示,当阻尼器选择合适的安放位置和合理的阻尼参数时,主、子结构的地震反应都会有一定程度的降低,从而收到较好的减震效果。  相似文献   

11.
非线性粘滞阻尼器消能结构设计方法探讨   总被引:2,自引:0,他引:2  
蒋通  贺磊 《世界地震工程》2007,23(1):134-140
在建立非线形粘滞阻尼器消能结构性能曲线的基础上,建议了依据减震性能目标确定阻尼器参数的概略设计方法。提出了多自由度非线性粘滞阻尼器消能结构的等效阻尼比计算公式。在此基础上建议了适用于多自由度非线性粘滞阻尼器消能结构地震反应预测的模态叠加法,方法与时程分析结果对比吻合良好。为使各层阻尼器参数更好地满足减震性能要求,提出了将概略设计得到的层阻尼器参数依据减振性能目标进行调整的方法。  相似文献   

12.
安装粘滞阻尼器结构的抗震设计方法研究   总被引:11,自引:1,他引:10  
本文研究了安装粘滞阻尼器结构在常遇地震作用下层间最大剪力的分配情况,建立了层间最大构件力与层间最大剪力的关系以及层间最大附加力与层间最大剪力的关系,提出了该类结构在罕遇地震作用下层间弹塑性变形的简化计算方法,最后建议了安装滞阻尼器结构的抗震设计步骤。  相似文献   

13.
Viscous and other damping devices are often used as elements of seismic isolation systems. Despite the widespread application of nonlinear viscous systems particularly in Japan (with fewer applications in the USA and Taiwan), the application of viscous damping devices in isolation systems in the USA progressed intentionally toward the use of supplementary linear viscous devices due to the advantages offered by these devices. This paper presents experimental results on the behavior of seismically isolated structures with low damping elastomeric (LDE) and single friction pendulum (SFP) bearings with and without linear and nonlinear viscous dampers. The isolation systems are tested within a six‐story structure configured as moment frame and then again as braced frame. Emphasis is placed both on the acquisition of data related to the structural system (drifts, story shear forces, and isolator displacements) and on non‐structural systems (floor accelerations, floor spectral accelerations, and floor velocities). Moreover, the accuracy of analytical prediction of response is investigated based on the results of a total of 227 experiments, using 14 historic ground motions of far‐fault and near‐fault characteristics, on flexible moment frame and stiff braced frame structures isolated with LDE or SFP bearings and linear or nonlinear viscous dampers. It is concluded that when damping is needed to reduce displacement demands in the isolation system, linear viscous damping results in the least detrimental effect on the isolated structure. Moreover, the study concludes that the analytical prediction of peak floor accelerations and floor response spectra may contain errors that need to be considered when designing secondary systems. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
This paper evaluates the seismic resistance of steel moment resisting frames (MRFs) with supplemental fluid viscous dampers against collapse. A simplified design procedure is used to design four different steel MRFs with fluid viscous dampers where the strength of the steel MRF and supplemental damping are varied. The combined systems are designed to achieve performance that is similar to or higher than that of conventional steel MRFs designed according to current seismic design codes. Based on the results of nonlinear time history analyses and incremental dynamic analyses, statistics of structural and non‐structural response as well as probabilities of collapse of the steel MRFs with dampers are determined and compared with those of conventional steel MRFs. The analytical frame models used in this study are reliably capable to simulate global frame collapse by considering full geometric nonlinearities as well as the cyclic strength and stiffness deterioration in the plastic hinge regions of structural steel members. The results show that, with the aid of supplemental damping, the performance of a steel MRF with reduced design base shear can be improved and become similar to that of a conventional steel MRF with full design base shear. Incremental dynamic analyses show that supplemental damping reduces the probability of collapse of a steel MRF with a given strength. However, the paper highlights that a design base shear equal to 75% of the minimum design base shear along with supplemental damping to control story drift at 2% (i.e., design drift of a conventional steel MRF) would not guarantee a higher collapse resistance than that of a conventional MRF. At 75% design base shear, a tighter design drift (e.g., 1.5% as shown in this study) is needed to guarantee a higher collapse resistance than that of a conventional MRF. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
The insertion of fluid viscous dampers in building structures is an innovative technology that can improve significantly the seismic response. These devices could be very useful also in the retrofit of existing buildings. The effect of this typology of damping system is usually identified with an equivalent supplemental damping ratio, which depends on the maximum displacement of the structure, so that iterative procedures are required. In this paper, a simplified direct assessment method for nonlinear structures equipped with nonlinear fluid viscous dampers is proposed. The method proposed in this study is composed by two steps. The first one yields the direct estimate of the supplemental damping ratio provided by nonlinear viscous dampers in presence of a linear elastic structural response. The second step extends the procedure to structures with nonlinear behavior. Both graphical and analytical approaches have been developed. The proposed method has then been verified through several applications and comparisons with nonlinear dynamic analyses. Moreover, an investigation has been performed with regard to the influence of the relations that define the damping reduction factor and the hysteretic damping. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
A methodology for the optimal design of supplemental viscous dampers for framed structures is presented. It addresses the problem of minimizing the added damping subject to a constraint on the maximal interstorey angular drift for an ensemble of realistic ground motion records while assuming linear behaviour of the damped structure. The solution is achieved by actually solving an equivalent optimization problem of minimizing the added damping subject to a constraint on a maximal weighted integral on the squared angular drift. The computational effort is appreciably reduced by first using one ‘active’ ground motion record. If the resulting optimal design fails to satisfy the constraints for other ground motions from the original ensemble, additional ground motions (loading conditions) are added one by one to the ‘active’ set until the optimum is reached. An efficient selecting process which is presented herein will usually require one or two records to attain an optimum design. Examples of optimal designs of supplemental dampers are presented for a 2‐storey shear frame and a 10‐storey industrial frame. The 2‐storey shear frame is required to withstand one given ground motion whereas the 10‐storey frame is required to withstand an ensemble of twenty ground motions. The resulting viscously damped structures have envelope values of interstorey drifts equal or less than the target drifts. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

17.
Optimal design of viscoelastic dampers using eigenvalue assignment   总被引:1,自引:0,他引:1  
In this study a procedure for determining the optimum size and location of viscoelastic dampers is proposed using the eigenvalue assignment technique. Natural frequencies and modal damping ratios, required to realize a given target response, are determined first by the convex model. Then the desired dynamic structural properties are realized by optimally distributing the damping and stiffness coefficients of viscoelastic dampers using non‐linear programming based on the gradient of eigenvalues. This optimization method provides information on the optimal location as well as the magnitude of the damper parameters. The proposed procedure is applied to the retrofit of a 10‐story shear frame, and to a three‐dimensional structure with an asymmetric plan. The analysis results confirm that the responses of model structures retrofitted by the proposed method correspond well with the given target response. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

18.
This paper deals with steel moment frames combined with hysteretic dampers. Specifically, it examines the strength of dampers required to minimize damage to moment frames under earthquake loading. The important structural variables are the ratio of the dampers' shear strength to the maximum resistance, termed β in this study, and the relative stiffness between the damper and the main frame, termed k. The equivalent viscous damping ratio of the entire structural system is affected by the quantities β and k and the ductility ratio of the main frame. The optimum dampers' strength ratio (βopt), which maximizes the equivalent viscous damping ratio, was formulated as a function of k, and it was found that βopt is independent of the ductility ratio of the main frame. Earthquake response analysis confirmed that damage to the main frame can be significantly reduced by hysteretic dampers and minimized at the value of βopt. © 1998 John Wiley & Sons, Ltd.  相似文献   

19.
巨子型有控结构体系中黏滞阻尼器参数研究   总被引:2,自引:0,他引:2  
巨子型有控结构体系(Mega-sub Controlled Structure System,即MSCSS)是一种新型的超高层建筑结构体系.本文针对MSCSS的构造特点,提出一种安装黏滞阻尼器的新的布置方案,通过研究该布置方案中取不同黏滞阻尼器参数时巨子型有控结构体系在罕遇地震作用下的动力响应,提出了与该结构体系动力特...  相似文献   

20.
Passive energy dissipation devices are increasingly implemented in frame structures to improve their performance under seismic loading. Most guidelines for designing this type of system retain the requirements applicable to frames without dampers, and this hinders taking full advantage of the benefits of implementing dampers. Further, assessing the extent of damage suffered by the frame and by the dampers for different levels of seismic hazard is of paramount importance in the framework of performance‐based design. This paper presents an experimental investigation whose objectives are to provide empirical data on the response of reinforced concrete (RC) frames equipped with hysteretic dampers (dynamic response and damage) and to evaluate the need for the frame to form a strong column‐weak beam mechanism and dissipate large amounts of plastic strain energy. To this end, shake‐table tests were conducted on a 2/5‐scale RC frame with hysteretic dampers. The frame was designed only for gravitational loads. The dampers provided lateral strength and stiffness, respectively, three and 12 times greater than those of the frame. The test structure was subjected to a sequence of seismic simulations that represented different levels of seismic hazard. The RC frame showed a performance level of ‘immediate occupancy’, with maximum rotation demands below 20% of the ultimate capacity. The dampers dissipated most of the energy input by the earthquake. It is shown that combining hysteretic dampers with flexible reinforced concrete frames leads to structures with improved seismic performance and that requirements of conventional RC frames (without dampers) can be relieved. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号