首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 781 毫秒
1.
近断层脉冲型地震动作用下隔震结构地震反应分析   总被引:17,自引:5,他引:17  
隔震结构在远震场地减震效果良好,但是近断层地震动的明显的长周期速度和位移脉冲运动可能对隔震建筑等长周期结构的抗震性能和设计带来不利影响,需要深入探讨。本文首先讨论近断层地震动的长周期脉冲运动特征,然后以台湾集集地震8条典型近震记录和其它4条常用近震记录以及4条远震记录作为地震动输入,对两幢安装铅芯橡胶隔震支座的钢筋混凝土框架隔震结构进行非线性地震反应时程分析,通过比较探讨了算例计算结果,定量说明隔震结构的近震脉冲效应显著,是隔震设计不容忽视的问题。  相似文献   

2.
In cities and urban areas, building structures located at close proximities inevitably interact under dynamic loading by direct pounding and indirectly through the underlying soil. Majority of the previous adjacent building pounding studies that have taken the structure–soil–structure interaction (SSSI) problem into account have used simple lumped mass–spring–dashpot models under plane strain conditions. In this research, the problem of SSSI‐included pounding problem of two adjacent symmetric in plan buildings resting on a soft soil profile excited by uniaxial earthquake loadings is investigated. To this end, a series of SSSI models considering one‐directional nonlinear impact elements between adjacent co‐planar stories and using a method for direct finite element modeling of 3D inelastic underlying soil volume has been developed to accurately study the problem. An advanced inelastic structural behavior parameter, the seismic damage index, has been considered in this study as the key nonlinear structural response of adjacent buildings. Based on the results of SSSI and fixed base case analyses presented herein, two main problems are investigated, namely, the minimum building separation distance for pounding prevention and seismic pounding effects on structural damage in adjacent buildings. The final results show that at least three times, the International Building Code 2009 minimum distance for building separation recommended value is required as a clear distance for adjacent symmetric buildings to prevent the occurrence of seismic pounding. At the International Building Code‐recommended distance, adjacent buildings experienced severe seismic pounding and therefore significant variations in storey shear forces and damage indices. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
Moat wall pounding occurs when a base-isolated building displaces beyond the provided clearance and collides with the surrounding retaining wall, inducing very high floor accelerations and interstory drifts. Previous studies on moat wall pounding typically employ simplified models of the superstructure, with a uniaxial contact spring used to model the entire moat wall. Consequently, researchers have developed sophisticated contact models to estimate the normal-direction contact force that is generated during seismic pounding. This study examines how the choice in contact model affects the seismic response of a base-isolated building subjected to impact-inducing ground excitation. Five widely used state-of-the-art contact models are summarized and implemented into an experimentally-calibrated numerical model of a base-isolated moment frame. Results of nonlinear dynamic time history analyses are shown in detail for one ground motion, followed by a larger parametric study across 28 near-fault ground motions. This work shows that peak impact force and base acceleration are moderately sensitive to the choice in contact model, while upper floor accelerations and interstory drifts are practically not affected.  相似文献   

4.
Seismic pounding of base‐isolated buildings has been mostly studied in the past assuming unidirectional excitation. Therefore, in this study, the effects of seismic pounding on the response of base‐isolated reinforced concrete buildings under bidirectional excitation are investigated. For this purpose, a three‐dimensional finite element model of a code‐compliant four‐story building is considered, where a newly developed contact element that accounts for friction and is capable of simulating pounding with retaining walls at the base, is used. Nonlinear behavior of the superstructure as well as the isolation system is considered. The performance of the building is evaluated separately for far‐fault non‐pulse‐like ground motions and near‐fault pulse‐like ground motions, which are weighted scaled to represent two levels of shaking viz. the design earthquake (DE) level and the risk‐targeted maximum considered earthquake (MCER) level. Nonlinear time‐history analyses are carried out considering lower bound as well as upper bound properties of isolators. The influence of separation distance between the building and the retaining walls at the base is also investigated. It is found that if pounding is avoided, the performance of the building is satisfactory in terms of limiting structural and nonstructural damage, under DE‐level motions and MCER‐level far‐fault motions, whereas unacceptably large demands are imposed by MCER‐level near‐fault motions. In the case of seismic pounding, MCER‐level near‐fault motions are found to be detrimental, where the effect of pounding is mostly concentrated at the first story. In addition, it is determined that considering unidirectional excitation instead of bidirectional excitation for MCER‐level near‐fault motions provides highly unconservative estimates of superstructure demands. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
Earthquake-induced building collapse and progressive collapse due to accidental local failure of vertical components are the two most common failure modes of reinforced concrete (RC) frame structures. Conventional design methods usually focus on the design requirements of a specific hazard but neglect the interactions between different designs. For example, the progressive collapse design of an RC frame often yields increased reinforcement and flexural strength of the beams. As a result, the seismic design principle of “strong-column-weak-beam” may be violated, which may lead to unfavorable failure modes and weaken the seismic performance. To avoid these adverse effects of the progressive collapse design on the seismic resistance of RC frames, a novel structural detailing is proposed in this study. The proposed detailing technique intends to concurrently improve the seismic and progressive collapse performances of an RC frame by changing the layout of the newly added longitudinal reinforcement against progressive collapse without introducing any additional reinforcement. A six-story RC frame is used as the prototype building for this investigation. Both cyclic and progressive collapse tests are conducted to validate the performance of the proposed structural detailing. Based on the experimental results, detailed finite element (FE) models of the RC frame with different reinforcement layouts are established. The seismic and progressive collapse resistances of different models are compared based on the incremental dynamic analysis (IDA) and nonlinear dynamic alternate path (AP) methods, respectively. The results indicate that the proposed structural detailing can effectively resolve the conflict between the seismic and progressive collapse designs.  相似文献   

6.
Past earthquake experiences indicate that most buildings designed in accordance with modern seismic design codes could survive moderate‐to‐strong earthquakes; however, the financial loss due to repairing cost and the subsequent business interruption can be unacceptable. Designing building structures to meet desired performance targets has become a clear direction in future seismic design practice. As a matter of fact, the performance of buildings is affected by structural as well as non‐structural components, and involves numerous uncertainties. Therefore, appropriate probabilistic approach taking into account structural and non‐structural damages is required. This paper presents a fuzzy–random model for the performance reliability analysis of RC framed structures considering both structural and non‐structural damages. The limit state for each performance level is defined as an interval of inter‐storey drift ratios concerning, respectively, the non‐structural and structural damage with a membership function, while the relative importance of the two aspects is reflected through the use of an appropriate cost function. To illustrate the methodology, herein the non‐structural damage is represented by infill masonry walls. The probabilistic drift limits for RC components and masonry walls from the associated studies are employed to facilitate the demonstration of the proposed model in an example case study. The results are compared with those obtained using classical reliability model based on single‐threshold performance definition. The proposed model provides a good basis for incorporating different aspects into the performance assessment of a building system. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

7.
孙臻  刘伟庆 《地震工程学报》2020,42(6):1369-1376
为了研究不同设计参数条件下基础隔震结构非线性响应的概率密度演化特征,采用两质点模型来模拟基础隔震结构,隔震层与上部结构分别采用Bouc-Wen模型与刚度退化的Bouc-Wen模型来描述其非线性特征,运用概率密度演化理论,进行隔震结构非线性随机地震响应的概率密度演化分析。采用基于物理的随机地震动模型生成人工地震动,提出基础隔震结构非线性随机地震响应的概率密度演化分析的基本步骤。通过改变基础隔震结构的设计参数,同时考虑激励的随机性,研究基础隔震结构非线性随机地震响应的概率密度演化规律。结果表明,基础隔震结构的阻尼比、周期比和屈重比取合理范围,能使隔震结构上部和下部的位移可控。  相似文献   

8.
杜永峰  黄小宁  李慧 《地震工程学报》2018,40(5):879-882,896
利用基于性能的结构可靠度分析方法,对基础隔震钢筋混凝土框剪结构进行分析研究。选取20条实际地震动记录,以0.2g为步长对结构地震动参数PGA进行调幅后,建立了140个结构-地震动样本空间。选取上部结构的最大层间位移角、隔震层位移为量化指标,对每一个样本进行动力非线性时程分析后,将结构响应进行统计得到结构在各地震动强度下超越极限破坏状态的概率,将其绘制成基础隔震钢筋混凝土框剪结构的易损性曲线并利用整体可靠度方法分析结构发生倒塌的可靠度指标。该方法直观地反映了结构发生倒塌的概率,为结构的地震损失评估提供依据。  相似文献   

9.
The nonlinear response of structures is usually evaluated by considering two accelerograms acting simultaneously along the orthogonal directions. In this study, the infl uence of the earthquake direction on the seismic response of building structures is examined. Three multi-story RC buildings, representing a very common structural typology in Italy, are used as case studies for the evaluation. They are, respectively, a rectangular plan shape, an L plan shape and a rectangular plan shape with courtyard buildings. Nonlinear static and dynamic analyses are performed by considering different seismic levels, characterized by peak ground acceleration on stiff soil equal to 0.35 g, 0.25 g and 0.15 g. Nonlinear dynamic analyses are carried out by considering twelve different earthquake directions, and rotating the direction of both the orthogonal components by 30° for each analysis(from 0° to 330°). The survey is carried out on the L plan shape structure. The results show that the angle of the seismic input motion signifi cantly infl uences the response of RC structures; the critical seismic angle, i.e., the incidence angle that produces the maximum demand, provides an increase of up to 37% in terms of both roof displacements and plastic hinge rotations.  相似文献   

10.
The effect of different structures configurations on the collision between adjacent planar RC building frames subjected to strong earthquakes is examined in this paper. Two 5‐storey and two 8‐storey frames, regular or with setbacks, are combined together to produce nine different pairs of adjacent RC structures. These pairs of buildings are subjected to six strong ground motions that are absolutely compatible with the design process. Various parameters are investigated such as maximum displacements, permanent displacements, members' ductility and internal forces and interstorey drift ratios. It is concluded that the effect of collision of adjacent frames seems to be unfavourable for most of the cases and, therefore, the structural pounding phenomenon is rather detrimental than beneficial. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
In this study the seismic pounding response of adjacent multi-degree-of-freedom(MDOF) buildings with bilinear inter-story resistance characteristics is investigated through dimensional analysis. The application of dimensional analysis leads to a condensed presentation of the response, and the remarkable self-similarity property for bilinear MDOF buildings with inelastic collision is uncovered. It is shown that when the response is expressed in the appropriate dimensionless form, response spectra for any intensity of the excitation collapse to a single master curve. The reduced Π set explicitly describes the interaction between the colliding structures. The effect of pounding on the MDOF building's response is illustrated using three well-divided spectral regions(amplifi ed, de-amplifi ed and unaffected regions). Parametric studies are conducted to investigate the effects of the story stiffness of structures, the story stiffness ratio and mass ratio of adjacent buildings, the structural inelastic characteristics and the gap size values. Results show that(i) the infl uence of system stiffness ratio to the lighter and more fl exible building is more signifi cant in the fi rst spectral region, where the maximum response of the building is amplifi ed because of pounding; and(ii) the velocity and pounding force of the heavier and stiffer building is unexpectedly sensitive to the mass ratio of adjacent buildings.  相似文献   

12.
为了提高钢筋混凝土建筑结构的抗震性能,分析多维地震作用下钢筋混凝土建筑结构的抗连续倒塌能力,结合钢筋混凝土建筑结构特性、节点构造特点以及其在多维地震作用下的破坏机理,采用离散单元法建立结构连续倒塌的理论模型,对建筑结构连续倒塌过程进行数值模拟。基于数值模拟化结果,通过备用荷载路径法,实现建筑结构的抗连续倒塌分析。仿真实验结果得出,所提方法能实现对建筑结构抗连续倒塌的准确分析,且在多维地震作用下建筑结构扭转的幅度明显变大,结构顶层位移发散状态显著,不同楼层会产生不同的层间位移以及薄弱部位,建筑结构的抗连续倒塌性能随着失效构件位置的提升而增强。  相似文献   

13.
Scientific research proposing any type of device/technique for seismic protection of buildings is generally based on numerical models that adopt simplifications to make possible extensive analyses. This means that important details of the inelastic response could be neglected. Following this consideration, regardless of the device/technique invented, before it could be put into practice, an experimental verification of the actual structural performance should be conducted by full-scale tests at building level. This issue is investigated in the paper considering seismic retrofit of reinforced concrete (RC) framed structures by buckling-restrained braces (BRBs) as technique to be validated, while hybrid test is selected as tool for experimental validation at building level. The analysed seismic upgrading technique consists in the insertion of BRBs into the RC frame. The upgrading intervention is designed by a method developed in previous studies. This technique responds to an important need of the society. Indeed, existing RC frames showed high vulnerability in occurrence of past earthquakes when they were not originally conceived to sustain horizontal forces. The hybrid test is selected among the available experimental techniques because it allows the experimentation on full-scale specimens with reasonable cost. In this study, a substructure hybrid test was conducted and the results are here presented to (a) evaluate the effectiveness of the design method of BRBs for seismic upgrading, (b) investigate the integration of BRBs in existing RC frame, and (c) show the potentiality of the substructure hybrid test for the experimental verification of innovative techniques for seismic protection of buildings.  相似文献   

14.
Since most current seismic capacity evaluations of reinforced concrete(RC) frame structures are implemented by either static pushover analysis(PA) or dynamic time history analysis,with diverse settings of the plastic hinges(PHs) on such main structural components as columns,beams and walls,the complex behavior of shear failure at beam-column joints(BCJs) during major earthquakes is commonly neglected.This study proposes new nonlinear PA procedures that consider shear failure at BCJs and seek to assess the actual damage to RC structures.Based on the specifications of FEMA-356,a simplified joint model composed of two nonlinear cross struts placed diagonally over the location of the plastic hinge is established,allowing a sophisticated PA to be performed.To verify the validity of this method,the analytical results for the capacity curves and the failure mechanism derived from three different full-size RC frames are compared with the experimental measurements.By considering shear failure at BCJs,the proposed nonlinear analytical procedures can be used to estimate the structural behavior of RC frames,including seismic capacity and the progressive failure sequence of joints,in a precise and effective manner.  相似文献   

15.
This study explores seismic performance of steel frame buildings with SMA-based self-centering bracing systems using a probabilistic approach. The self-centering bracing system described in this study relies on superelastic response of large-diameter cables. The bracing systems is designed such that the SMA cables are always stressed in tension. A four-story steel frame building characterized until collapse in previous research is selected as a case-study building. The selected steel frame building is designed with SMA bracing systems considering various design parameters for SMA braces. Numerical models of these buildings are developed by taking into account the ultimate state of structural components and SMA braces as well as the effect of gravity frames on lateral load resistance. Nonlinear static analyses are conducted to assess the seismic characteristics of each frame and to examine the effect of SMA brace failure on the seismic load carrying capacity of SMA-braced frames. Incremental dynamic analyses (IDA) are performed to compute seismic response of the designed frames at various seismic intensity levels. The results of IDA are used to develop probabilistic seismic demand models for peak inter-story and residual inter-story drifts. Seismic demand hazard curves of peak and residual inter-story drifts are generated by convolving the ground motion hazard with the probabilistic seismic demand models. Results show that steel frames designed with SMA bracing systems provide considerably lower probability of reaching at a damage state level associated with residual drifts compared to a similarly designed steel moment resisting frame, especially for seismic events with high return periods. This indicates reduced risks for the demolition and collapse due to excessive residual drifts for SMA braced steel frames.  相似文献   

16.
Seismic fragility curves for fixed-base and base-isolated liquid storage tanks are developed under non-stationary earthquakes, and their seismic performance are compared. The correlation between different earthquake intensity measure (IM) parameters and peak response quantities of the base-isolated liquid storage tanks are investigated. The failure criteria are chosen based on (1) the elastic buckling strength of the tank wall, which is defined in terms of critical base shear and critical overturning moment, and (2) in terms of the critical isolation displacement. The uncertainty involved is considered in the earthquake characteristics. Non-stationary earthquake ground motions are generated using Monte Carlo (MC) simulation. Influence of the isolator characteristic parameters and modeling approaches on the seismic fragility of the base-isolated liquid storage tanks is also investigated. Peak ground acceleration is found to be the well correlated IM parameter with the peak response quantities of the base-isolated liquid storage tanks. Substantial decrease in the seismic fragility of the base-isolated liquid storage tanks is observed as compared to the fixed-base tanks. Significant influence of the isolator characteristic parameters on the seismic fragility of the base-isolated liquid storage tanks are reported in the present study.  相似文献   

17.
总结采用梁有效翼缘来考虑楼板及配筋对“强柱弱梁”机制形成的影响的实验和数值仿真研究。基于SAP2000采用三种侧向加载模式对RC框架结构不带楼板、不带楼板考虑梁刚度放大、带楼板的三个模型进行pushover分析,对力与位移的关系曲线、塑性铰的出铰顺序以及顶点位移与层间位移等方面进行探讨。结果表明:三个模型的“强柱弱梁”现象不带楼板的纯框架结构最明显,考虑梁刚度放大的模型次之,带楼板结构最不明显,证明负弯矩承载力和刚度等反映“强柱弱梁”的参数及塑性铰的出现顺序与楼板、板内配筋存在明显的对应关系;楼板及配筋影响框架结构的整体变形性能和塑性耗能能力,是抗震延性机制实现的重要影响因素。在后续的结构设计中,建议考虑实际楼板和钢筋建模进行计算分析。  相似文献   

18.
对建筑物灾变发生时经济损失和人员伤亡情况做出准确预估是未来建筑结构设计初期需要努力的方向。基于下一代性能化设计理论,通过精细化建模和动力时程分析对结构进行易损性分析,并以此得到抗震性能评估所需的各类地震响应参数,建立RC框架结构全概率抗震性能评估方法。以云南大学力行楼为例,通过地震损失预测得到了该栋建筑的经济损失、修复时间和人员伤亡情况。该方法直观清晰地展示了结果,便于业主及非本专业从业者理解。  相似文献   

19.
It is well known that the axial load plays an important role in the evaluation of the structural capacity of RC columns. In existing buildings this problem can be even more significant than in new ones, since the material can easily present poor mechanical properties. The paper is aimed at the investigation of the role of the axial load variation on the seismic performance of RC columns of a case-study, i.e. a doubly symmetric 4-storey RC building. The effects of the axial load variation have been checked on the first storey columns, by comparing the seismic response, measured in terms of chord rotation and shear force, with the corresponding capacity. The sensitivity of the seismic performance to the axial load is evaluated with special attention on the type of analysis adopted to determine the seismic response and on considering a wide range of values for the concrete strength. The study points out a non-negligible effect of the axial load variation on the seismic response of the case-study building, especially when combined to concrete strength variability.  相似文献   

20.
One of the main challenges in earthquake risk mitigation is the assessment of existing buildings not designed according to modern codes and the development of effective techniques to strengthen these structures. Particular attention should be given to RC frame structures with masonry infill panels, as demonstrated by their poor performance in recent earthquakes in Europe. Understanding the seismic behaviour of masonry‐infilled RC frames presents one of the most difficult problems in structural engineering. Analytical tools to evaluate infill–frame interaction and the failure mechanisms need to be further studied. This research intends to develop a simplified macro‐model that takes into account the out‐of‐plane behaviour of the infill panels and the corresponding in‐plane and out‐of‐plane interaction when subjected to seismic loadings. Finally, a vulnerability assessment of an RC building will be performed in order to evaluate the influence of the out‐of‐plane consideration in the building response. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   