首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A procedure for the determination of chlorine by the isotope dilution technique (ID) using negative thermal ionisation mass spectrometry (N-TIMS) is described. Silicate samples of about 10 mg were spiked and decomposed with hydrofluoric acid, and chlorine was isolated by precipitation of silver chloride after neutralisation with Ca(OH)2. The ammonical solution of AgCl was then subjected to N-TIMS. Replicate analyses of rock reference materials, typically of JB-1 and JR-1, demonstrated the high quality of the analyses (precision for Cl was ± 1-2%). We present here the most precise data sets of chlorine concentrations in nine igneous rock reference materials, three basalts (JB-1, JB-2, JB-3), two andesites (JA-3, AGV-1), two rhyolites (JR-1, JR-2) and two granodiorites (JG-3, GSP-1). The chlorine concentrations found ranged from 152 μg g-1 in AGV-1 to 1008 μg g-1 in JR-1. Our results presented here are partly (but not completely) in agreement with recommended values, where they are available. The N-TIMS ID technique can thus be used as a means of determining low chlorine contents in silicate materials to high precision.  相似文献   

2.
Molybdenum concentrations in eleven USGS geochemical reference materials AGV-1, BCR-1, BHVO-1, BIR-1, DNC-1, DTS-1, G-2, GSP-1, MAG-1, PCC-1 and W-2 were measured by isotope dilution thermal ionisation mass spectrometry (ID-TIMS). In every case but one, the concentrations determined in this study were significantly lower than the current consensus values. Molybdenum concentrations determined by ID-TIMS are inherently more accurate and precisions may be up to an order of magnitude higher than those measured by other analytical techniques.  相似文献   

3.
A precise and simple method for the determination of lithium concentrations in small amounts of silicate sample was developed by applying isotope dilution-inductively coupled plasma-mass spectrometry (ID-ICP-MS). Samples plus a Li spike were digested with HF-HClO4, dried and diluted with HNO3, and measured by ICP-MS. No matrix effects were observed for 7Li/6Li in rock solutions with a dilution factor (DF) of 97 at an ICP power of 1.7 kW. By this method, the determination of 0.5 μg g-1 Li in a silicate sample of 1 mg can be made with a blank correction of < 1%. Lithium contents of ultrabasic to acidic silicate reference materials (JP-1, JB-2, JB-3, JA-1, JA-2, JA-3, JR-1 and JR-2 from the Geological Survey of Japan, and PCC-1 from the US Geological Survey) and chondrites (three different Allende and one Murchison sample) of 8 to 81 mg were determined. The relative standard deviation (RSD) was typically < 1.7%. Lithium contents of these samples were further determined by isotope dilution-thermal ionisation mass spectrometry (ID-TIMS). The relative differences between ID-ICP-MS and ID-TIMS were typically < 2%, indicating the high accuracy of ID-ICP-MS developed in this study.  相似文献   

4.
Isotope dilution (ID) mass spectrometry is a primary method of analysis suited for the accurate and precise measurement of several trace elements in geological matrices. Here we present mass fractions and respective uncertainties for Cr, Cu, Ni, Sn, Sr and Zn in 10 silicate rock reference materials (BCR‐2, BRP‐1, BIR‐1, OU‐6, GSP‐2, GSR‐1, AGV‐1, RGM‐1, RGM‐2 and G‐3) obtained by the double ID technique and measuring the isotope ratios with an inductively coupled plasma‐mass spectrometer equipped with collision cell. Test portions of the samples were dissolved by validated procedures, and no further matrix separation was applied. Addition of spikes was designed to achieve isotope ratios close to unity to minimise error magnification factors, according to the ID theory. Radiogenic ingrowth of 87Sr from the decay of 87Rb was considered in the calculation of Sr mass fractions. The mean values of our results mostly agree with reference values, considering both uncertainties at the 95% confidence level, and also with ID data published for AGV‐1. Considering all results, the means of the combined uncertainties were < 1% for Sr, approximately 2% for Sn and Cu, 4% for Cr and Ni and almost 6% for Zn.  相似文献   

5.
The concentration of boron was determined in twenty one geochemical reference materials (silicate rocks) by isotope dilution inductively coupled plasma-mass spectrometry. Boron was extracted from the rocks using HF digestion, suppressing boron volatilisation through boron-mannitol complexation. Sample solutions, in a diluted HCl matrix, were analysed by ICP-MS without any separation of boron from the matrix elements. The results obtained were in agreement with the literature data and indicate that using the described procedure, trace amounts of boron can be very easily determined in complex matrices with rapidity and precision. With the instrumentation and reagents used in this study, this procedure can be used for the determination of 0.5 μg g−1 boron in a 15 0 mg silicate rock sample. Replicate analyses of the twenty one geochemical reference materials (GRM), ranging in boron concentration from 1.35 to 15 7 μg g−1, yielded precisions (relative standard deviation) varying between 0.9 and 9.8%.  相似文献   

6.
This paper briefly outlines the production and certification of reference materials at the Central Geological Laboratory (CGL) of Mongolia. The marketing of CRMs produced in Mongolia, as well as problems encountered in internationally recognised certification attempts and some proposed solutions, are discussed. The basic elements of the CGL’s strategy for the development of the CRM sector are to produce high quality CRMs according to the requirements of internationally recognised norms, to consider the market needs, to certify the RMs at the international level and to widely advertise them to the geochemical community. The CGL has already established the basis for the further development of this sector by, for instance, accreditation under ISO/IEC 17025, by modernising its preparation technology, by cooperation with international organisations in the field of CRMs and by permanent participation in the International Association of Geoanalysts’ GeoPT™ proficiency testing programme.  相似文献   

7.
We present a multi-element technique for the simultaneous determination of twelve trace elements in geological materials by combined isotope dilution (ID) sector field inductively coupled plasma-mass spectrometry (SF-ICP-MS) following simple sample digestion. In addition, the concentrations of fourteen other trace elements have been obtained using the ID determined elements as internal standards. This method combines the advantages of ID (high precision and accuracy) with those of SF-ICP-MS (multi-element capability, fast sample processing without element separation) and overcomes the most prevailing drawbacks of ICP-MS (matrix effects and drift in sensitivity). Trace element concentration data for BHVO-1 (n = 5) reproduced to within 1–3% RSD with an accuracy of 1–2% relative to respective literature values for ID values and 2–3% for all other values. We have applied this technique to the analysis of seventeen geological reference materials from the USGS, GSJ and IAG. The sample set also included the new USGS reference glasses BCR-2G, BHVO-2G and BIR-1G, as well as the MPI-DING reference glasses KL2-G and ML3B-G, and NIST SRM 612. Most data agreed within 3–4% with respective literature data. The concentration data for the USGS reference glasses agreed in most cases with respective data of the original rock powder within the combined standard uncertainty of the method (2–3%), except the U concentration of BIR-1G, which showed a three times higher concentration compared to BIR-1.  相似文献   

8.
Two independent articles published more than a decade ago pointed to the potential of the somewhat neglected K‐Ca system for very precise K‐Ca dating and thermochronology, but have not been followed up since. In the first of these articles, highly precise determination of K and hence the K/Ca ratio in lunar granites showed the feasibility of K‐Ca dates of micas with an analytical precision known so far in only U‐Pb and Ar/Ar dating. In the second article, it was shown that responses of the K‐Ca and Rb‐Sr isotopic systems in micas subjected to a slow post‐metamorphic cooling could provide new insights into thermochronology. Crucial to the follow‐up of these two promising leads is the development of a simple and user‐friendly method for routine high precision K determination in real samples, such as the one described in this report.  相似文献   

9.
Mass fractions of Sn and In were determined in sixteen geological reference materials including basaltic/mafic (BCR‐2, BE‐N, BHVO‐1, BHVO‐2, BIR‐1, OKUM, W‐2, WS‐E), ultramafic (DTS‐2b, MUH‐1, PCC‐1, UB‐N) and felsic/sedimentary reference materials (AGV‐2, JA‐1, SdAR‐M2, SdAR‐H1). Extensive digestion and ion exchange separation tests were carried out in order to provide high yields (> 90% for Sn, > 85% for In), low total procedural blanks (~ 1 ng for Sn, < 3 pg for In) and low analytical uncertainties for the elements of interest in a variety of silicate sample matrices. Replicate analyses (= 2–13) of Sn–In mass fractions gave combined measurement uncertainties (2u) that were generally < 3% and in agreement with literature data, where available. We present the first high‐precision In data for reference materials OKUM (32.1 ± 1.5 ng g?1), DTS‐2b (2.03 ± 0.25 ng g?1), MUH‐1 (6.44 ± 0.30 ng g?1) and PCC‐1 (3.55 ± 0.35 ng g?1) as well as the first Sn data for MUH‐1 (0.057 ± 0.010 μg g?1) and DTS‐2b (0.623 ± 0.018 μg g?1).  相似文献   

10.
International carbon and oxygen isotope calibration material NBS 19 and reference materials NBS 18, International Atomic Energy Agency (IAEA)-CO-1 and IAEA-CO-8 are prepared from naturally occurring rock specimens of marble and carbonatite. Mineralogical and chemical analysis showed that only NBS 19 and IAEA-CO-1 represent essentially pure samples of calcite containing < and minimal (< 1%) quantities of quartz. In contrast, both NBS 18 and IAEA-CO-8, although primarily composed of calcite, are contaminated by a range of additional phases. NBS 18 was estimated to contain 1% Fe-dolomite and trace (< 1%) quantities of apatite and quartz. IAEA-CO-8 was estimated to contain at least 4% non-carbonate material (including apatite, barite, biotite and magnetite). NBS 18 and IAEA-CO-8 are both derived from samples of carbonatite and the calcite component of each material is characterised by appreciable substitution of Mg + Mn + Sr ± Fe ± Ba (Σ ≈ 14000–15000 μg g-1) for Ca. The observations reported in this study complement data in the literature detailing significant grain-scale isotopic heterogeneity in NBS 18 and IAEA-CO-8. Both data sets highlight the need for careful characterisation of calibration materials prior to distribution.  相似文献   

11.
During the past decade the work of ISO/REMCO, the International Organization for Standardization’s Technical Committee on Reference Materials, was dedicated to achieving global harmonisation, and true involvement of the member countries. The first major accomplishment was the clarification of the terminology in the definitions for reference material and certified reference material, which were published as an amendment to ISO Guide 30 in 2008. The next milestone was the recognition that ISO Guide 34 (‘General requirements for the competence of reference material producers’) be used in conjunction with ISO/IEC 17025 for the accreditation of reference material producers. The third edition of ISO Guide 34 published in November 2009, clarifies the acceptable procedures for the certification of reference materials. This paper will discuss the role of ISO/REMCO in formalising the procedures for the accreditation of reference material producers and the evolution of the terms reference material and certified reference material. The paper will conclude with a case study, where a primary method in a single laboratory – one of the recognised acceptable metrologically valid procedures according to ISO Guide 34 – was used for the certification of reference materials. The reference materials are South African Reference Material SARM 2 (Syenite), SARM 3 (Lujavrite) and SARM 4 (Norite) from the suite of six NIMROCs that were originally certified by the Council for Mineral Technology (MINTEK) in South Africa in the 1970s.  相似文献   

12.
Chromium (Cr) isotopes have been widely used in various fields of Earth and planetary sciences. However, high‐precision measurements of Cr stable isotope ratios are still challenged by difficulties in purifying Cr and organic matter interference from resin using double‐spike thermal ionisation mass spectrometry. In this study, an improved and easily operated two‐column chemical separation procedure using AG50W‐X12 (200–400 mesh) resin is introduced. This resin has a higher cross‐linking density than AG50W‐X8, and this higher density generates better separation efficiency and higher saturation. Organic matter from the resin is a common cause of inhibition of the emission of Cr during analysis by TIMS. Here, perchloric and nitric acids were utilised to eliminate organic matter interference. The Cr isotope ratios of samples with lower Cr contents could be measured precisely by TIMS. The long‐term intermediate measurement precision of δ53/52CrNIST SRM 979 for BHVO‐2 is better than ± 0.031‰ (2s) over one year. Replicated digestions and measurements of geological reference materials (OKUM, MUH‐1, JP‐1, BHVO‐1, BHVO‐2, AGV‐2 and GSP‐2) yield δ53/52CrNIST SRM 979 results ranging from ?0.129‰ to ?0.032‰. The Cr isotope ratios of geological reference materials are consistent with the δ53/52CrNIST SRM 979 values reported by previous studies, and the measurement uncertainty (± 0.031‰, 2s) is significantly improved.  相似文献   

13.
A new method has been developed for the simultaneous determination of Pb abundance and Pb isotopic composition with high precision and accuracy for small test portion masses by thermal ionisation mass spectrometry. In this method, a 205pb-204pb double spike is added to samples prior to the chemical separation of Pb, and the isotopic composition of the spike-sample mixture is determined rigorously by the double spike technique using a 207Pb-204Pb spike. The isotopic composition and concentration of Pb in the sample are then obtained by utilising the principle of isotope dilution. Using this technique, replicate determinations of Pb from NIST SRM 981 and GSJ JP-1 (peridotite; 0.07 μg g−1 Pb) were performed. The measured concentration and isotopic data were identical, within uncertainty, to published data or to data that were determined independently in this study. The application of this method to U-Pb dating and the determination of the "initial" Pb isotopic composition was also tested. Lead isotopic compositions and the concentrations of Pb, Th and U were determined for a single batch of samples, through the addition of 205pb-204pb, 230Th and 235U spikes to samples prior to chemical separation. Also in these experiments, we confirmed that this routine gives accurate data for Pb, Th and U concentrations and Pb isotopic compositions.  相似文献   

14.
A simple and accurate method for the determination of Cr, Ni, Cu and Zn at μg g?1 levels in milligram‐sized bulk silicate materials is reported using isotope dilution high‐resolution inductively coupled plasma‐mass spectrometry (HR‐ICP‐MS) with a flow injection system. Silicate samples with Cr, Ni, Cu and Zn spikes were digested with HF‐HBr and Br2, and subsequently decomposed at 518 K in a Teflon bomb. In this procedure, all sulfides and chromite, major hosts of these elements, were completely decomposed, thus allowing for isotope equilibration between the sample and spike. Magnesium and Al fluorides formed after the digestion of the sample were removed by centrifugation, and the supernatant was directly aspirated into a HR‐ICP‐MS at a mass resolution of 7500, where interfering oxide ions, ArO+, CaO+, TiO+, CrO+ and VO+, were separated from Cr+, Ni+, Cu+ and Zn+. No matrix effects were observed down to a dilution factor of 50. Detection limits for these elements in silicate samples were < 0.04 μg g?1. The effectiveness of the technique was demonstrated by the analysis of 13 to 40 mg test portions of USGS and GSJ silicate reference materials with a major element composition ranging from andesite to peridotite, in addition to 8‐23 mg of the Smithsonian reference Allende. Both the reproducibility and the deviation from the reference value for most reference materials of various rock types were < 9%, and thus confirm that the method gives accurate analytical results for small sample sizes over a wide range of Cr, Ni, Cu and Zn contents. This method is, therefore, suitable for analysing small and/or precious bulk samples, such as meteorites, mantle peridotites and mineral separates, and for the characterisation of silicate and sulfide minerals for use as calibration samples in secondary ion mass spectrometry or laser ablation ICP‐MS.  相似文献   

15.
In this paper, we applied a reliable technique for measuring Fe isotope variations in coastal seawater at nanomolar levels. Iron was directly pre-concentrated from acidified seawater samples onto a nitrilotriacetic acid chelating resin and further purified using anion-exchange resin. Sample recovery, determined using a standard addition method, was essentially quantitative. Iron was then determined using a high-resolution multicollector ICP-MS (Neptune) coupled to an ApexQ desolvation introduction system. The external precision for δ56Fe values was 0.11‰ (2s) when using total a Fe quantity between 25 and 100 ng. We initially applied this technique to measure the Fe isotope composition of dissolved Fe from several coastal environments in the north-eastern United States and we observed a range of δ56Fe values between -0.9‰ and 0.1‰ relative to the IRMM-14 reference material. Iron isotope compositions of several reference water materials for inter-laboratory comparisons were also reported. Our results suggest that iron in coastal seawater, derived from benthic diagenesis and/or groundwater has negative Fe isotopic signatures that are distinct from other iron sources such as atmospheric deposition and rivers.  相似文献   

16.
The commonly used, but no longer available, reference materials NIST SRM 976 (Cu) and ‘JMC Lyon’ (Zn) were calibrated against the new reference materials ERM®‐AE633, ERM®‐AE647 (Cu) and IRMM‐3702 (Zn), certified for isotope amount ratios. This cross‐calibration of new with old reference materials provides a continuous and reliable comparability of already published with future Cu and Zn isotope data. The Cu isotope amount ratio of NIST SRM 976 yielded δ65/63Cu values of ?0.01 ± 0.05‰ and ?0.21 ± 0.05‰ relative to ERM®‐AE633 and ERM®‐AE647, respectively, and a δ66/64ZnIRMM‐3702 value of ?0.29 ± 0.05‰ was determined for ‘JMC Lyon’. Furthermore, we separated Cu and Zn from five geological reference materials (BCR‐2, BHVO‐2, BIR‐1, AGV‐1 and G‐2) using a two‐step ion‐exchange chromatographic procedure. Possible isotope fractionation of Cu during chromatographic purification and introduction of resin‐ and/or matrix‐induced interferences were assessed by enriched 65Cu isotope addition. Instrumental mass bias correction for the isotope ratio determinations by MC‐ICP‐MS was performed using calibrator‐sample bracketing with internal Ni doping for Cu and a double spike approach for Zn. Our results for the five geological reference materials were in very good agreement with literature data, confirming the accuracy and applicability of our analytical protocol.  相似文献   

17.
In this study, a high‐precision method for the determination of Sm and Nd concentrations and Nd isotopic composition in highly depleted ultramafic rocks without a preconcentration step is presented. The samples were first digested using the conventional HF + HNO3 + HClO4 method, followed by the complete digestion of chromite in the samples using HClO4 at 190–200 °C and then complete dissolution of fluoride formed during the HF decomposition step using H3BO3. These steps ensured the complete digestion of the ultramafic rocks. The rare earth elements (REEs) were separated from the sample matrix using conventional cation‐exchange chromatography; subsequently, Sm and Nd were separated using the LN columns. Neodymium isotopes were determined as NdO+, whereas Sm isotopes were measured as Sm+, both with very high sensitivity using single W filaments with TaF5 as an ion emitter. Several highly depleted ultramafic rock reference materials including USGS DTS‐1, DTS‐2, DTS‐2b, PCC‐1 and GSJ JP‐1, which contain extremely low amounts of Sm and Nd (down to sub ng g?1 level), were analysed, and high‐precision Sm and Nd concentration and Nd isotope data were obtained. This is the first report of the Sm‐Nd isotopic compositions of these ultramafic rock reference materials except for PCC‐1.  相似文献   

18.
One or two gram aliquots of twelve reference materials with low platinum-group element (PGE) abundances (Ir concentrations ranging from 30 to 510 pg g-1) were analysed by isotope dilution ICP-MS using an on-line chromatographic matrix separation after acid digestion in a high pressure asher (HPA-S) to determine the concentrations of Ru, Pd, Re, Ir and Pt. Osmium concentrations were determined via ID-ICP-MS but as volatile OsO4, whereas Rh concentrations were calculated by comparing the peak areas of the chromatographic peak with that of a standard solution. Validation of the method was performed and the concepts of traceability and measurement uncertainty were applied to assure comparability. The reference materials BCR-2, BHVO-1, BHVO-2, BIR-1, DNC-1, EN026 10D-3, MAG-1, RGM-1, SCo-1, SDO-1, TDB-1 and W-2 were investigated to test for their usefulness for certification. The use of TDB-1 is highly recommended because it is homogeneous at the two gram level and many values based on several different analytical procedures have been published. It is recommended that our efforts should focus on the certification of this reference material to reduce the uncertainties of its currently certified values (Pd and Pt only) and to assign certified values to the other PGE and Re. It is necessary to have at least one well-characterised RM for validation of methods applied to the analysis of PGE and Re in low abundance samples, although the matrix of TDB-1 might not completely match those of many samples.  相似文献   

19.
Isotope dilution calibration has been applied to the determination of Zr and Hf in whole rocks by laser ablation (LA)-ICP-MS. Enriched isotopes were added during the preparation of flux-free, synthetic whole rock glasses and homogenised through a combination of grinding and fusion. This method avoids problems, such as solution instability and the chemical resistance of minerals such as zircon, inherent in acid digestion sample preparation. The use of isotope dilution removes the need for external calibration using certified reference material glasses such as NIST SRM 612 for which certified Zr and Hf values are not available. The precision of Zr and Hf determinations were found to be < 1% and 3.5% respectively, limited by Poisson counting statistics which contributed to 50% of the final precision of analysis. Measured values correlate closely with compiled literature values.  相似文献   

20.
Geological reference materials (RMs) with variable compositions and NIST SRM 612 were analysed by isotope dilution mass spectrometry for bulk rock concentrations of chalcogen elements (sulfur, selenium and tellurium), rhenium and platinum‐group elements (PGEs: Ru, Pd, Os, Ir and Pt), including the isotope amount ratios of 187Os/188Os. All concentrations were obtained from the same aliquot after HCl‐HNO3 digestion in a high pressure asher at 320 °C. Concentrations were determined after chemical separation by negative TIMS, ICP‐MS and hydride generation ICP‐MS (Se, Te). As in previous studies, concentrations of the PGEs in most RMs were found to be highly variable, which may be ascribed to sample heterogeneity at the < 1 g level. In contrast, S, Se and Te displayed good precision (RSD < 5%) in most RMs, suggesting that part of the PGE budget is controlled by different phases, compared with the chalcogen budget. The method may minimise losses of volatile chalcogens during the closed‐system digestion and indicates the different extent of heterogeneity of chalcogens, Re and PGEs in the same sample aliquot. OKUM, SCo‐1, MRG‐1, DR‐N and MAG‐1 are useful RMs for the chalcogens. NIST SRM 612 displays homogenous distribution of S, Se, Te, Pt and Pd in 30 mg aliquots, in contrast with micro‐scale heterogeneity of Se, Pd and Pt.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号