首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents an effective approach for achieving minimum‐cost designs for seismic retrofitting using nonlinear fluid viscous dampers. The damping coefficients of the dampers and the stiffness coefficients of the supporting braces are designed by an optimization algorithm. A realistic retrofitting cost function is minimized subject to constraints on inter‐story drifts at the peripheries of frame structures. The cost function accounts for costs related to both the topology and the sizes of the dampers. The behavior of each damper‐brace element is defined by the Maxwell model, where the force–velocity relation of the nonlinear dampers is formulated with a fractional power law. The optimization problem is first posed and solved as a mixed integer problem. For the reduction of the computational effort required in the optimization, the problem is then reformulated with continuous variables only and solved with a gradient‐based algorithm. Material interpolation techniques, which have been successfully applied in topology optimization and in multi‐material optimization, play a key role in achieving practical final design solutions with a reasonable computational effort. Promising results attained for 3‐D irregular frames are presented and discussed. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

2.
In this study, several mass dampers were designed and fabricated to suppress the seismic responses of a ¼‐scale three‐storey building structure. The dynamic properties of the dampers and structure were identified from free and forced vibration tests. The building structure with or without the dampers was, respectively, tested on a shake table under the white noise excitation, the scaled 1940 El Centro earthquake and the scaled 1952 Taft earthquake. The dampers were placed on the building floors using the sequential procedure developed by the authors in previous studies. Experimental results indicated that the multiple damper system is substantially superior to a single tuned mass damper in mitigating the floor accelerations even though the multiple dampers are sub‐optimal in terms of tuning frequency, damping and placement. These results validated the sequential procedure for placement of the multiple dampers. The structure was also analysed numerically based on the shake table excitation and the identified structure and damper parameters for all test cases. Numerical and experimental results are in good agreement, validating the dynamic properties identified. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
A methodology for the optimal design of supplemental viscous dampers for regular as well as irregular yielding shear‐frames is presented. It addresses the problem of minimizing the added damping subject to a constraint on an energy‐based global damage index (GDI) for an ensemble of realistic ground motion records. The applicability of the methodology for irregular structures is achieved by choosing an appropriate GDI. For a particular choice of the parameters comprising the GDI, a design for the elastic behavior of the frame or equal damage for all stories is achieved. The use of a gradient‐based optimization algorithm for the solution of the optimization problem is enabled by first deriving an expression for the gradient of the constraint. The optimization process is started for one ‘active’ ground motion record which is efficiently selected from the given ensemble. If the resulting optimal design fails to satisfy the constraints for other records from the original ensemble, additional ground motions (loading conditions) are added one by one to the ‘active’ set until the optimum is reached. Two examples for the optimal designs of supplemental dampers are given: a 2‐story shear frame with varying strength distribution and a 10‐story shear frame. The 2‐story shear frame is designed for one given ground motion whereas the 10‐story frame is designed for an ensemble of twenty ground motions. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

4.
The effectiveness of hysteretic passive devices to protect and mitigate the response of a structure under seismic loading is well established by both analytical and experimental research. Nevertheless, a systematic and well‐established methodology for the topological distribution and size of these devices in order to achieve a desired structural response performance does not exist. In this paper, a computational framework is proposed for the optimal distribution and design of yielding metallic buckling restrained braces (BRB) and/or friction dampers within steel moment‐resisting frames (MRF) for a given seismic environment. A Genetic Algorithm (GA) is used to solve the resulting discrete optimization problem. Specific examples involving two three‐story, four‐bay steel MRFs and a six‐story, three‐bay steel MRF retrofitted with yielding and/or friction braces are considered. The seismic environment consists of four synthetic ground motions representative of the west coast of the United States with 5% probability of exceedance in 50 years. Non‐linear time‐history analyses are employed to evaluate the potential designs. As a result of the evolutionary process, the optimal placement, strength and size of the dampers are obtained throughout the height of the steel MRF. Furthermore, the developed computational approach for seismic design based upon GAs provides an attractive procedure for design of MRFs with hysteretic passive dampers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
The optimal design and placement of controllers at discrete locations is an important problem that will have impact on the control of civil engineering structures. Though algorithms exist for the placement of sensor/actuator systems on continuous structures, the placement of controllers on discrete civil structures is a very difficult problem. Because of the nature of civil structures, it is not possible to place sensors and actuators at any location in the structure. This usually creates a non‐linear constrained mixed integer problem that can be very difficult to solve. Using genetic algorithms in conjunction with gradient‐based optimization techniques will allow for the simultaneous placement and design of an effective structural control system. The introduction of algorithms based on genetic search procedures should increase the rate of convergence and thus reduce the computational time for solving the difficult control problem. The newly proposed method of simultaneously placing sensors/actuators will be compared to a commonly used method of sensors/actuators placement where sensors/actuators are placed sequentially. The savings in terms of energy requirements and cost will be discussed. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

6.
Buildings are continually subject to dynamic loads, such as wind load, seismic ground motion, and even the load from internal utility machines. The recent trend of constructing more flexible high‐rise buildings underscores the importance of including viscoelastic dampers in building designs. Viscoelastic dampers are used to control the dynamic response of a building. If the seismic design is based only on the linear response spectrum, considerable error may occur when calculating the seismic response of a building; rubber viscoelastic dampers show non‐linear hysteretic damping that is quite different from viscous damping. This study generated a non‐linear response spectrum using a non‐linear oscillator model to simulate a building with viscoelastic dampers installed. The parameters used in the non‐linear damper model were obtained experimentally from dynamic loading tests. The results show that viscoelastic dampers effectively reduce the seismic displacement response of a structure, but transmit more seismic force to the structure, which essentially increases its seismic acceleration response. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

7.
There has been a significant increase in the size of building structures in recent years. Huge structures such as high‐rise buildings and large‐domed stadiums require high‐performance structural control, including the use of high‐capacity dampers, especially in an earthquake‐prone country like Japan. The objective of the present study was the enhancement of both human and structural safety in such structures through the development of a rate‐dependent type of damper with a high damping capacity. Among the various available types of rate‐dependent dampers, the authors focused on the oil damper owing to its stable performance against long‐duration vibrations. The target maximum damping force was 6000 kN, which is higher than that of any existing oil damper utilized in building structures. The authors developed a novel concept for achieving this high capacity while maintaining the size of the damper within acceptable dimensions from an architectural point of view. The concept involves the use of multiple damper units that produce mechanically parallel damping forces spatially arranged in series. As a prototype, a 1500‐kN oil damper was fabricated by combining three 500‐kN dampers. The 1500‐kN prototype damper was conceived as a full‐scale prototype of a damper that is more slender than comparable commercially available dampers in Japan, and as a scaled model of the proposed 6000‐kN damper. Sinusoidal loading tests were conducted on the prototype damper using a frequency range of 0.1–1.5 Hz and a velocity range of 0.4–300 mm/s. The results confirmed that the damper produced the design damping forces. The results of earthquake loading tests also revealed that the damper exerted a stable damping force against a large earthquake and maintained its performance after the earthquake. The damper is particularly effective against earthquakes with long‐period components that could increase the temperature of a damper. This is afforded by its high heat capacity compared to conventional dampers. Considering that the proposed 6000‐kN damper will generate a damping force that is about 2–3 times that of the strongest conventional oil damper, existing manufacturer test machines would be inadequate for evaluating its full performance characteristics. To address this issue, the authors also propose a test method for evaluating the overall damping force. The method is premised on the fact that the characteristic feature of the proposed damper is its combination of multiple damper units. The overall performance is thus evaluated using the test results for the individual damper units while the other dampers are bypassed. This method was verified by the results of the abovementioned sinusoidal loading tests, with the error for the 1500‐kN prototype damper found to be less than 5%. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
The aim of this paper was to propose a design guideline for using visco‐elastic dampers for the control of building structures subjected to earthquake loading as well as suspension roof structures subjected to wind loading. The active control algorithm was used to calculate the control forces. Based on the single‐mode approach the control forces were transformed to the forces which visco‐elastic dampers can provide. Application of the method to the design of the building structure with passive damping devices in the bracing system and to the suspension roof with dampers was studied. Through the application of optimal control theory a systematic design procedure to implement dampers in structures is proposed. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

9.
A series of large‐scale dynamic tests was conducted on a passively controlled five‐story steel building on the E‐Defense shaking table facility in Japan to accumulate knowledge of realistic seismic behavior of passively controlled structures. The specimen was tested by repeatedly inserting and replacing each of four damper types, that is, the buckling restrained braces, viscous dampers, oil dampers, and viscoelastic dampers. Finally, the bare steel moment frame was tested after removing all dampers. A variety of excitations was applied to the specimen, including white noise, various levels of seismic motion, and shaker excitation. System identification was implemented to extract dynamic properties of the specimen from the recorded floor acceleration data. Damping characteristics of the specimen were identified. In addition, simplified estimations of the supplemental damping ratios provided by added dampers were presented to provide insight into understanding the damping characteristics of the specimen. It is shown that damping ratios for the specimen equipped with velocity‐dependent dampers decreased obviously with the increasing order of modes, exhibiting frequency dependency. Damping ratios for the specimen equipped with oil and viscoelastic dampers remained constant regardless of vibration amplitudes, whereas those for the specimen equipped with viscous dampers increased obviously with an increase in vibration amplitudes because of the viscosity nonlinearity of the dampers. In very small‐amplitude vibrations, viscous and oil dampers provided much lower supplemental damping than the standard, whereas viscoelastic dampers could be very efficient. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
In real‐time hybrid simulations (RTHS) that utilize explicit integration algorithms, the inherent damping in the analytical substructure is generally defined using mass and initial stiffness proportional damping. This type of damping model is known to produce inaccurate results when the structure undergoes significant inelastic deformations. To alleviate the problem, a form of a nonproportional damping model often used in numerical simulations involving implicit integration algorithms can be considered. This type of damping model, however, when used with explicit integration algorithms can require a small time step to achieve the desired accuracy in an RTHS involving a structure with a large number of degrees of freedom. Restrictions on the minimum time step exist in an RTHS that are associated with the computational demand. Integrating the equations of motion for an RTHS with too large of a time step can result in spurious high‐frequency oscillations in the member forces for elements of the structural model that undergo inelastic deformations. The problem is circumvented by introducing the parametrically controllable numerical energy dissipation available in the recently developed unconditionally stable explicit KR‐α method. This paper reviews the formulation of the KR‐α method and presents an efficient implementation for RTHS. Using the method, RTHS of a three‐story 0.6‐scale prototype steel building with nonlinear elastomeric dampers are conducted with a ground motion scaled to the design basis and maximum considered earthquake hazard levels. The results show that controllable numerical energy dissipation can significantly eliminate spurious participation of higher modes and produce exceptional RTHS results. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
12.
A simplified design procedure (SDP) for preliminary seismic design of frame buildings with structural dampers is presented. The SDP uses elastic‐static analysis and is applicable to structural dampers made from viscoelastic (VE) or high‐damping elastomeric materials. The behaviour of typical VE materials and high‐damping elastomeric materials is often non‐linear, and the SDP idealizes these materials as linear VE materials. With this idealization, structures with VE or high‐damping elastomeric dampers can be designed and analysed using methods based on linear VE theory. As an example, a retrofit design for a typical non‐ductile reinforced concrete (RC) frame building using high‐damping elastomeric dampers is developed using the SDP. To validate the SDP, results from non‐linear dynamic time history analyses (NDTHA) are presented. Results from NDTHA demonstrate that the SDP estimates the seismic response with sufficient accuracy for design. It is shown that a non‐ductile RC frame building can be retrofit with high‐damping elastomeric dampers to remain essentially elastic under the design basis earthquake (DBE). Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

13.
Investigated are earthquake responses of one‐way symmetric‐plan, one‐storey systems with non‐linear fluid viscous dampers (FVDs) attached in series to a linear brace (i.e. Chevron or inverted V‐shape braces).Thus, the non‐linear damper is viscous when the brace is considered rigid or viscoelastic (VE) when the brace is flexible. The energy dissipation capacity of a non‐linear FVD is characterized by an amplitude‐dependent damping ratio for an energy‐equivalent linear FVD, which is determined assuming the damper undergoes harmonic motion. Although this formulation is shown to be advantageous for single‐degree‐of‐freedom (SDF) systems, it is difficult to extend its application to multi‐degree‐of‐freedom (MDF) systems for two reasons: (1) the assumption that dampers undergo harmonic motion in parameterizing the non‐linear damper is not valid for its earthquake‐induced motion of an MDF system; and (2) ensuring simultaneous convergence of all unknown amplitudes of dampers is difficult in an iterative solution of the non‐linear system. To date, these limitations have precluded the parametric study of the dynamics of MDF systems with non‐linear viscous or VE dampers. However, they are overcome in this investigation using concepts of modal analysis because the system is weakly non‐linear due to supplemental damping. It is found that structural response is only weakly affected by damper non‐linearity and is increased by a small amount due to bracing flexibility. Thus, the effectiveness of supplemental damping in reducing structural responses and its dependence on the planwise distribution of non‐linear VE dampers were found to be similar to that of linear FVDs documented elsewhere. As expected, non‐linear viscous and VE dampers achieve essentially the same reduction in response but with much smaller damper force compared to linear dampers. Finally, the findings in this investigation indicate that the earthquake response of the asymmetric systems with non‐linear viscous or VE dampers can be estimated with sufficient accuracy for design applications by analysing the same asymmetric systems with all non‐linear dampers replaced by energy‐equivalent linear viscous dampers. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

14.
A systematic method for optimal added damper placement in building structures is developed, taking into account the response amplification due to the surface ground. Non-linear amplification of the surface ground is described by an equivalent linear model. Hysteretic damping of the surface ground and radiational damping into the semi-infinite visco-elastic ground are included in the model. An original steepest direction search algorithm is applied to the interaction model. Closed-form expressions of the inverse of the coefficient matrix (tri-diagonal matrix) enable one to compute the transfer function and its derivative with respect to design variables very efficiently. It is shown that the ratio of the fundamental natural period of the structure to that of the surface ground is a key parameter for characterizing the optimal damper placement. Several examples for different soil conditions are presented to demonstrate the effectiveness and validity of the present method.  相似文献   

15.
A series of large‐scale real‐time hybrid simulations (RTHSs) are conducted on a 0.6‐scale 3‐story steel frame building with magneto‐rheological (MR) dampers. The lateral force resisting system of the prototype building for the study consists of moment resisting frames and damped brace frames (DBFs). The experimental substructure for the RTHS is the DBF with the MR dampers, whereas the remaining structural components of the building including the moment resisting frame and gravity frames are modeled via a nonlinear analytical substructure. Performing RTHS with an experimental substructure that consists of the complete DBF enables the effects of member and connection component deformations on system and damper performance to be accurately accounted for. Data from these tests enable numerical simulation models to be calibrated, provide an understanding and validation of the in‐situ performance of MR dampers, and a means of experimentally validating performance‐based seismic design procedures for real structures. The details of the RTHS procedure are given, including the test setup, the integration algorithm, and actuator control. The results from a series of RTHS are presented that includes actuator control, damper behavior, and the structural response for different MR control laws. The use of the MR dampers is experimentally demonstrated to reduce the response of the structure to strong ground motions. Comparisons of the RTHS results are made with numerical simulations. Based on the results of the study, it is concluded that RTHS can be conducted on realistic structural systems with dampers to enable advancements in resilient earthquake resistant design to be achieved. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
It is well known that the classical optimal control method requires all the state variables of the controlled system to be measurable and available for control feedback. However, for a high‐order or complex system some state variables are possibly unmeasurable in practice. In addition, the control cost will be higher if more sensors are used, because it is expensive to install sensors. On the other hand, when using the optimal control method with full‐state feedback, some state variables in control feedback have only a small effect on control performance. Neglecting these state variables does not affect the control performance greatly. Good control effectiveness can be obtained by using only the state variables that have a big effect on the control performance. So the questions become how to determine those state variables which have a big effect on the control performance? and how to design the optimal controller using only the determined state variables? The discrete sub‐optimal control method with partial‐state feedback is investigated in this paper. Firstly, the continuous control system and performance index are both transformed into discrete forms. Then the state variables, which have a big effect on the control performance, are determined using the second‐order sensitivity which is the second‐order derivative of the performance index with respect to control gain. The sub‐optimal controller is finally designed using only the determined state variables. Numerical examples are worked out to demonstrate the application of the proposed control algorithm. It is shown that the relative importance of each state variable can be indicated clearly by the second‐order sensitivity. The sub‐optimal control method presented is effective in reducing maximum responses of the structure. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

17.
A new computational framework is developed for the design and retrofit of building structures by considering aseismic design as a complex adaptive process. For the initial phase of the development within this framework, genetic algorithms are employed for the discrete optimization of passively damped structural systems. The passive elements may include metallic plate dampers, viscous fluid dampers and viscoelastic solid dampers. The primary objective is to determine robust designs, including both the non‐linearity of the structural system and the uncertainty of the seismic environment. Within the present paper, this computational design approach is applied to a series of model problems, involving sizing and placement of passive dampers for energy dissipation. In order to facilitate our investigations and provide a baseline for further study, we introduce several simplifications for these initial examples. In particular, we employ deterministic lumped parameter structural models, memoryless fitness function definitions and hypothetical seismic environments. Despite these restrictions, some interesting results are obtained from the simulations and we are able to gain an understanding of the potential for the proposed evolutionary aseismic design methodology. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

18.
A numerical solution based on the Steffensen stable point iterative method is proposed to resolve the transcendental frequency equation of a stay cable-damper system. The frequency equation, which considers clamped supports and fl exural rigidity of the cable, is intended to investigate the infl uence of the parameters of the cable damper system on its dynamic characteristics. Two factors involved in the design and construction phases, the damping coeffi cient induced by external dampers and the cable tension, are the focus of this study. Their impact on modal frequencies and damping ratios in these two phases of cable-damper systems are investigated by resolving the equation with the proposed solution. It is shown that the damping coeffi cient and cable tension exert more noticeable effects on the modal damping ratios than on the modal frequencies of stay cable-damper systems, and the two factors can serve as design variables in the design phase and as adjustment factors in the construction phase. On the basis of the results, a roadmap for system-level optimal design of stay cable-damper systems that can achieve global optimal vibration suppression for the entire bridge is proposed and discussed.  相似文献   

19.
Viscoelastic–plastic (VEP) dampers are hybrid passive damping devices that combine the advantages of viscoelastic and hysteretic damping. This paper first formulates a semi‐analytical procedure for predicting the peak response of nonlinear SDOF systems equipped with VEP dampers, which forms the basis for the generation of Performance Spectra that can then be used for direct performance assessment and optimization of VEP damped structures. This procedure is first verified against extensive nonlinear time‐history analyses based on a Kelvin viscoelastic model of the dampers, and then against a more advanced evolutionary model that is calibrated to characterization tests of VEP damper specimens built from commercially available viscoelastic damping devices, and an adjustable friction device. The results show that the proposed procedure is sufficiently accurate for predicting the response of VEP systems without iterative dynamic analysis for preliminary design purposes. A design method based on the Performance Spectra framework is then proposed for systems equipped with passive VEP dampers and is applied to enhance the seismic response of a six‐storey steel moment frame. The numerical simulation results on the damped structure confirm the use of the Performance Spectra as a convenient and accurate platform for the optimization of VEP systems, particularly during the initial design stage. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
In this paper, the effectiveness of different design solutions for tuned mass dampers (TMD) applied to high‐rise cross‐laminated (X‐Lam) timber buildings as a means to reduce the seismic accelerations was investigated. A seven‐storey full‐scale structure previously tested on shaking table was used as a reference. The optimal design parameters of the TMDs, i.e. damping and frequency ratios, were determined by using a genetic algorithm on a simplified model of the reference structure, composed by seven masses each representing one storey. The optimal solutions for the TMDs were then applied to a detailed finite element model of the seven‐storey building, where the timber panels were modelled with shell elements and the steel connectors with linear spring. By comparing the numerical results of the building with and without multiple TMDs, the improvement in seismic response was assessed. Dynamic time‐history analyses were carried out for a set of seven natural records, selected in accordance with Eurocode 8, on the simplified model, and for Kobe earthquake ground motion on the detailed model. Results in terms of acceleration reduction for different TMD configurations show that the behaviour of the seven‐storey timber building can be significantly improved, especially at the upper storeys. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   