首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
螺旋桩芯劲性复合桩(helix stiffened cement mixing pile,简称HSCM桩)是一种新型复合桩,其成桩工艺会对桩身及其承载性能有较大影响。为验证HSCM桩在软黏土中同步旋进注浆工艺的可行性,并研究其成桩参数对抗压承载性能的影响,设计了2组缩尺模型试验,包括不同叶片数量与钻进速度的HSCM桩与对比螺旋桩。通过在高岭土制备的软黏土中成桩,并进行抗压承载性能及桩身几何尺寸测试,分析HSCM桩的成桩参数与水泥土桩身间的关系。试验结果表明:同步旋进注浆工艺能够在螺旋桩周围形成倒圆台状的水泥土桩身,水泥土桩身的平均黏结直径约为叶片直径的1.17~1.35倍;适当增加叶片数量能够使水泥与土体充分拌和,提高水泥土桩身的完整性与连续性,以改善HSCM桩的成桩质量;钻进速度大幅提高会导致注浆量不足,减小水泥土桩身的黏结直径与刚度;试验条件下HSCM桩的抗压极限承载力是螺旋桩的3.83~3.93倍,桩径扩大提高了侧摩阻力,注浆工艺加固并提高了土体强度,弥补了叶片在旋进过程中扰动土体造成强度降低的问题。  相似文献   

2.
Abstract

Helical piles are used mainly to resist tension forces generated by uplift and overturning moments of various structures, therefore they have been suggested as a potential alternative to driven piles as offshore pile because they provide a large uplift capacity due to the anchor effect of the helix. To date no standards are available for the assessment of the use of helical piles in the offshore environment. State-of-the art installation and uplift capacity assessment is based on field onshore tests on small helical piles. The purpose of this review is to critically evaluate the current knowledge on helical piles considering uplift capacity, cyclic load, installation torque models and the parameters affecting the installation torque, to understand whether they can be considered for potential offshore applications. The paper could be of valuable interest for engineers and contractors involved in the offshore installation of piles.  相似文献   

3.
Drilled displacement (DD) piles with a screw-shaped shaft (referred to as DD piles) are installed using a continuous full thread hollow rod (without a displacement body) inserted and advanced in the soil by both a vertical force and a torque. As a type of newly developed pile, current understanding of the bearing mechanism of DD piles is unsatisfactory, which restricts their further applications in engineering. The primary aim of this paper is to study the bearing mechanism of this type of pile using a numerical method. First, a numerical model for calculating the bearing capacity of the DD piles was created and validated by a laboratory test. Then, the effects of the parameters of pile–soil interface, soil strength, and pile geometrical parameters on the bearing mechanism of the DD piles were investigated in parametric studies. The results of parametric studies show that the limit shear stress on the pile–soil interface, the friction angle of surrounding sand, screw pitch, and thread width significantly influence the bearing capacity of the DD piles, whereas the friction coefficient at the pile–soil interface and the thread thickness have little effect. Based on the results of the parametric studies, the failure mechanism of the DD piles under vertical load is analyzed. Finally, an equation for predicting the ultimate bearing capacities of helical piles based on cylindrical shear failure was used for estimating the bearing capacity of the DD piles, and the calculated results were verified with the numerical results.  相似文献   

4.
桩基础是我国海上风电工程中应用最为广泛的基础形式,其中嵌岩桩因其施工难度大,承载力高备受关注。与其他类型的桩基础不同,嵌岩桩的水平承载力不仅受到围岩强度的影响,更与其成桩质量与灌浆材料的强度相关。采用有限元方法分析了嵌岩深度、桩基直径与壁厚、桩身倾斜度等多种因素对嵌岩桩水平承载力的影响,提出了确定嵌岩桩水平极限抗力的标准。研究表明:桩与围岩间的灌浆环会先于桩身发生破坏,因此可将灌浆环受拉破坏作为判断嵌岩桩达到水平极限承载力的标准;桩身倾斜度对嵌岩桩的水平极限承载力影响较大,直径和壁厚的增加,均能提高桩基的水平承载力。  相似文献   

5.
Abstract

A closure on the recent discussion regarding the review on the behavior of helical piles as a potential offshore foundation system by the Authors is presented. Installation torque, uplift capacity, installation effects, model pile, installation speed and results proposed by Discussers are commented.  相似文献   

6.
Abstract

An experimental study of the performance of concrete pipe piles during installation under different penetration speeds and static load tests on the piles in sand is presented. The applied jacking force, the amount of pile penetration, length of soil plug formed and ultimate bearing capacity were measured during the model tests. The results showed that the concrete pipe piles were partially plugged and the behavior of the soil plug was significantly affected by the penetration speed. The lower the penetration speed, the larger the soil plug formed which in turn leads to a greater ultimate bearing capacity. The size of soil plug can be evaluated by the m value defined as the ratio of the volume of the soil plug to that of the penetrated pile wall. The relationship between the m value and the penetration speeds can be used to estimate the amount of soil plug and the depth of penetration for an open-ended concrete pipe pile jacked into sand.  相似文献   

7.
Abstract

In onshore and offshore fields of ocean engineering, piles are used as foundation systems for various structures. Piles are classified into different types depending on their materials, geometries, and particularly, installation methods, which have advantages or limitations. Companies and engineers have developed a new group of piles, because of necessity to improve their performance in terms of increasing the bearing capacity, reducing impacts of traditional installation procedures, implementing by low- torque power equipment, and utilizing them in widely different ground conditions, including in a marine environment. In the present study, three different models of a new pile with an expander body are introduced to increase the shaft and pile-toe diameters and its self-expansion in the embedment depth under the titles of the Bubble pile (BP), Self-Expanded pile (SEP) and Wing pile (WP). The main subject of this research is to achieve increased bearing capacity, reduced installation effects, and decreased required installation torque. The frustum-confining vessel of Amirkabir University of Technology (FCV-AUT) was employed for this purpose. Up to 14 axial compressive and tensile load tests were carried out on different model piles on sand collected from Anzali shore located on the northern coast of Caspian Sea in Iran, with relative densities of 45% to 50% within FCV-AUT. Comparing the performance of introduced pile with traditional pile corresponding to the same characteristics, the results indicated a significant increase in the axial bearing capacity and reduced disturbance effect of the pile. Also, a lower installation torque of the SE pile was required compared to the helical pile. The test results also demonstrated that the new pile could resist considerable compressive and uplift loads, and could be a possible alternative to traditional piles in the onshore sector.  相似文献   

8.
Abstract

Open‐pipe piles are widely used for offshore structures. During the initial stage of installation, soil enters the pile at a rate equal to the pile penetration. As penetration continues, the inner soil cylinder may develop sufficient frictional resistance to prevent further soil intrusion, causing the pile to become plugged. The open‐ended pile then assumes the penetration characteristics of a closed‐ended pile. The mode of pile penetration significantly alters the soil‐pile interaction during and after installation. This affects the ultimate static bearing capacity (mainly in granular materials), the time‐dependent pile capacity (in clays), and the dynamic behavior and analysis of the piles.

Following a summary demonstrating the effects of pile plugging, a review of the common view of offshore pile plugging is undertaken. The interpretation of plugging by referring to the average plug length has led to the erroneous conclusion that in most piles significant plugging action does not occur.

Establishment of an analogy between soil samplers and open‐ended piles enabled correct identification of plugging by referring to the incremental changes in plug length. Examination of case histories of plugging of offshore piles revealed that beyond a certain penetration depth‐to‐diameter ratio, most piles are plugged.  相似文献   

9.
Helical piles are structural deep foundation elements, which can be categorized as torque-driven piles without any limitations to implement in marine situations. Different methods are used to predict the axial capacity of helical piles, such as static analysis, but have some limitation for this type of piles on marine conditions. In situ testing methods as supplement of static analysis have been rarely used for helical piles. In geotechnical engineering practice, the most common in situ tests particularly applicable for coastal or offshore site investigation are cone penetration test (CPT) and piezocone penetration test (CPTu). The CPT is simple, repeatable, and prepares the continuous records of soil layers. In this paper, a data bank has been compiled by collecting the results of static pile load tests on thirty-seven helical piles in ten different sites including CPT or CPTu data. Axial capacities of thirty-seven helical piles in different sites were predicted by direct CPT methods and static analysis. Accuracy estimation of ten direct CPT methods to predict the axial capacity of helical piles was investigated in this study. Comparisons have been made among predicted values and measured capacity from the pile load tests. Results indicated that the recently developed methods such as NGI-05 (2005), ICP-05 (2005), and UWA-05 (2005) predicted axial capacity of helical piles more accurately than the other methods such as Meyerhof (1983), Schmertmann (1978), Dutch (1979), LCPC (1982), or Unicone (1997). However, more investigations are required to establish better correlation between CPT data and axial capacity of helical piles.  相似文献   

10.
In offshore engineering, pile foundations are commonly constructed in marine deposits to support various structures such as offshore platforms. These piles are subjected to lateral cyclic loading due to wind, wave action, and drag load from ships. In this paper, centrifuge model tests are conducted to investigate the response of the existing single piles due to lateral cyclic loading. The cyclic loading was simulated by a hydraulic actuator. It is found that the residual lateral movement and bending strain are induced in the existing pile after each loading–unloading cycle. This is because plastic deformation is induced in the soil surrounding the existing pile during each loading–unloading cycle. By increasing the applied loads during cyclic loading–unloading process, the lateral movements and bending strains induced in the pile head increase simultaneously. As the cyclic loading varies from 10 to 50 kN, the residual pile head movement increases from 40 to 154?mm, and the residual bending strain of the existing pile varies from 100 to 260 με. The ratio of residual to the maximum pile head movements varies from 0.17 to 0.22, while the ratio of residual to the maximum bending strains is in a range of 0.12–0.55.  相似文献   

11.
Helical piles present a possible alternative to driven displacement piles in the offshore sector. While this type of pile is used widely in the onshore environment, design methods tend to be highly empirical and there is considerable uncertainty around the bearing resistance and the installation resistance required to install large diameter piles necessary to resist uplift. The paper combines a theoretical model for estimating torque resistance from the literature with a cone penetration test (CPT)-based model originally developed to estimate the axial resistance of helical piles and to predict the installation torque required to install piles in sand. The model appears to be able to capture the general installation behavior of piles across a range of scales and in various sand states.  相似文献   

12.
This study has evaluated the vertical bearing capacity by conducting static load tests for noise-free and vibration-free screw pretensioned spun high-strength concrete (PHC) piles installed using two different methods (end-squirting shoe and pre-boring methods). Vertical bearing capacity differences seem to occur due to the displacement of soils near the external circumference of a pile, depending on the installation method. A method by which to evaluate the bearing capacity of screw concrete piles is suggested by considering the equations that already have been used to calculate the bearing capacity of piles. Based on static load tests and analysis, the pile installed using the end-squirting shoe method was assumed to be a bored pile and it was reasonable to use the equation proposed by the Japanese Geotechnical Society. At the same time, the pile installed using the pre-boring method was deemed a low soil displacement pile and so it was reasonable to apply the equations proposed for calculating the bearing capacity of the driven pile suggested by the Architectural Institute of Japan.  相似文献   

13.
Granular piles are frequently used as a method of improving soft grounds as they provide increased bearing capacity and reduce foundation settlements. However, in very soft clayey soils, they may not derive their load-carrying capacity by low confining pressure provided by the surrounding soil. In such circumstances, granular piles may be reinforced with suitable geosynthetic to increase its load-carrying capacity and to reduce excessive bulging. In this study, the performance of small group of geosynthetic-reinforced granular piles (GRGPs) is examined in terms of load-carrying capacity, settlement, and modulus by laboratory model tests. The parameters investigated include modulus of reinforcement material, area replacement ratio (ARR) based on the column diameter and reinforcement length. The results indicated that increasing the modulus of the reinforcement and the ARR based on the column diameter enhances the overall performance of the GRGP group. It was also observed that reinforcement on top portion of the granular pile is sufficient to substantially increase the load-carrying capacity of granular pile group.  相似文献   

14.
Abstract

Helical piles have emerged as an attractive foundation system for offshore applications with renewed interest from the offshore community. Significant research gap currently exists in transferring this technology offshore and this paper discusses how existing and emerging knowledge can be successfully used to bridge some of the gaps. We focus on the Coupled Eulerian Lagrangian (CEL) large deformation finite element (LDFE) modelling technique that is commercially available and can be used to model the three-dimensional installation process with consideration of strain rate and softening effects in soft offshore clays. A helical pile of L?=?7.5?m long is modelled with one or two large-diameter helices (D?=?2?m) attached to a central shaft of d?=?0.5?m in diameter.The net effect of strain rate and softening is to increase the installation torque. The measured torque is within the range of 200–400?kN.m for the offshore clay and the pile geometry studied. Additional helices increase the uplift force but to a lesser degree than that of the measured torque. Remoulding induced strength reduction is found to be within the range of 25–33% of the intact clay strength. Issues of extracting and reusing offshore helical pile foundations are discussed.  相似文献   

15.
Abstract

In practice, how to quickly improve the bearing capacity of piles in a short time is of great significance. In view of this, a technique of setting grooves and installing PVDs (prefabricated vertical drains) at the surface of the pile is proposed in this investigation to accelerate the consolidation of the surrounding soil. A radial and circular consolidation model is established for permeable piles. The finite cosine transform, finite Weber transform, and discretization method are used to obtain a semi-analytical solution for the consolidation model with a mixed drainage boundary condition at the surface of the pile. The sensitivity of the consolidation process to the strip number and the width of PVDs is discussed. The results show that the technique of installing PVDs in piles could potentially improve the bearing capacity. When the area of drainage channels is fixed, the bearing capacity of permeable piles can be more effectively improved by using a higher strip number of PVDs and a smaller PVD width.  相似文献   

16.
Foundation piles of the offshore oil platforms in the Bohai Bay are usually longer than 100 m with a diameter larger than 2 m.Driving such long and large-sized piles into the ground is a difficult task.It needs a comprehensive consider ation of the pile dimensions,soil properties and the hammer energy.Thoughtful drivability analysis has to be performed in the design stage.It has been shown that judging whether the soil column inside the pile is fully plugged,which makes the pile behave as close-ended,strongly influences the accuracy of drivability analysis.Engineering practice repeatedly indicates that the current methods widely used for soil plug judgment often give incorrect results,leading the designers to make a wrong decision.It has been found that this problem is caused by the ignorance of the bearing capacity provided by the soil surrounding the pile.Based on the Terzaghi’s bearing capacity calculation method for deep foundation,a new approach for judging soil plug status is put forward,in which the surcharge effect has been considered and the dynamic effect coefficient is included.This approach has been applied to some practical engineering projects successfully,which may give more reasonable results than the currently used method does.  相似文献   

17.
大直径钢管桩土塞效应的判断和沉桩过程分析   总被引:5,自引:0,他引:5  
港口工程和海洋工程中出现了越来越多的大直径超长钢管桩。由于这种桩直径较大,土塞的形成对桩的可打入性和承载力有较大的影响。鉴于此,根据大直径和超大直径钢管桩土塞性状的特殊性,考虑了桩直径对侧壁摩阻力、端阻力的影响,引入了尺寸效应系数,重新建立了土塞微分体的静力平衡方程,提出了采用改进的静力平衡法进行土塞效应判断,同时采用波动方程法近似模拟土塞与桩管内壁的相互作用,建立了简化的土塞与桩壁相互作用模型,并用该方法进行实际工程的打桩分析,分析结果表明该方法对土塞效应的判断、打桩过程的预测等与工程实测数据吻合较好。  相似文献   

18.
In this study, the dynamic response of pile foundation in dry sandy soil excited by two opposite rotary machines was considered experimentally. A small scale physical model was manufactured to accomplish the experimental work in the laboratory. The physical model consists of two small motors supplied with eccentric mass (0.012?kg) and eccentric distance (20?mm) representing the two opposite rotary machines, an aluminum shaft as the pile, and a steel plate a pile cap. The experimental work was achieved taking the following parameters into considerations: pile embedment depth ratio (L/d, where L is the pile length and d is its diameter) and operating frequency of the rotary machines. All tests were conducted in medium dense fine sandy soil with 60% relative density. Twelve tests were performed to measure the change in load transferred through the pile’s tip to the underlying soil. To predict precisely the dynamic load that will be induced from the rotary machines, a mini load cell with a capacity of 100?kg was mounted between the aluminum plate (the machine base) and the steel plate (pile cap). The results revealed that, before machine operation, the pile tip load was approximately equal to the static load (machine and pile cap), whereas during machines’ operation, the pile tip load decreased for all embedment depth ratios and operating frequencies. This reduction was due to the action of skin friction that was mobilized along the pile during operation, and as a result the factor of safety against pile bearing failure increases. For all operating frequencies and pile lengths, the factor of safety against bearing failure increased during machines’ operation, where the pile tip load became less than its value before starting operation. During operation, the skin friction resistance mobilized along pile length led to decrease the bearing load.  相似文献   

19.
The low side friction of piles in coral sand results in the low bearing capacity of foundations. In this paper, expansive concrete pile is utilized to improve the bearing capacity of pile foundations in coral sand. Both model tests and numerical simulation are performed to reveal the bearing mechanism of expansive concrete pile in coral sand.Results showed that the lateral earth pressure near pile increases obviously and the side friction of piles is improved,after adding expansion agent to the concrete. The horizontal linear expansion is 1.11% and the bearing capacity increased 41% for the pile, when 25% expansion agent is added. Results in finite element numerical simulation also show that ultimate bearing capacity increases with the increase of the linear expansion ratio. Besides, the area for obvious increase in side friction is below the surface of soil about three times the pile diameter, and the expansion leads to a high side friction sharing of the pile. Therefore, the cast-in-place expansive concrete pile is effective in improving the bearing capacity of piles in coral sand.  相似文献   

20.
ABSTRACT

An analytical solution is developed in this paper to investigate the vertical time-harmonic response of a large-diameter variable-section pile, and it considers the radial inhomogeneity of the surrounding soil caused by construction disturbance. First, the saturated soil surrounding the pile is described by Biot’s poroelastic theory and a series of infinitesimally thin independent layers along the shaft of the pile, and the pile is represented by a variable-section Rayleigh–Love rod. Then, the dynamic equilibrium equations of the soil and pile are solved to obtain an analytical solution for the impedance function at the pile top using the complex stiffness transfer method and impedance function transfer method. Finally, the proposed solution is compared with previous solutions to verify its reliability, and a parameter study is conducted to provide insights into the sensitivity of the vertical dynamic impedance of the pile and velocity response in low-strain integrity testing on defective piles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号