Direct measurements of sensible heat fluxes were conducted over a grass surface at Ladner, British Columbia, using yaw-sphere-thermometer eddy-correlation systems. The results show that for half-hour averaging periods, there is no phase-lag between sensible heat and net radiation flux densities. Field comparison of two yaw-sphere-thermometer systems gave good and consistent agreement. At a height of 2 m above ground and a horizontal crosswind separation of 1.5 m, less than 5% variability was noted in the measured heat fluxes. For a 19-m horizontal separation, the variability was less than 20%. The aridity index (α) advanced by Priestley and Taylor (1972), is shown to be a potentially useful climatic indicator. 相似文献
4.
A modified infrared CO2 gas analyzer, a small thermocouple assembly, a heated-thermocouple anemometer for horizontal wind, and a propeller-type vertical wind sensor were used to measure the eddy fluxes of heat and CO2 above a corn crop. Experimental results of these fluxes are discussed. The main sources of errors of the eddy fluxes using these instruments were estimated:
- Sensors with a time constant of 0.5 s appear to be fast enough to detect most of the vertical CO2 transfer as long as the sensors are located at least one meter above the crop surface.
- The deviation from steady-state conditions for 10-min periods was found to have a significant effect on the eddy flux estimates.
- Temperature fluctuations of the air sample passing through the CO2 infrared gas analyzer were found to be non-negligible but could be easily corrected.
- A 1° misalignment of the vertical anemometer affected these eddy fluxes by less than 10% under all circumstances studied.
5.
Modelling surface turbulent fluxes in stable conditions 总被引:3,自引:0,他引:3
6.
近地面层湍流通量观测误差的比较 总被引:5,自引:1,他引:5
本文根据误差理论分析并比较了在近地面层内各种间接确定湍流通量方法的观测误差。空气动力学法由于采用不同的通用函数将造成很大的误差。H扣除法确定潜热通量,当Bowen比较小时误差较小,Bowen比B>1之后误差随B的增大迅速增长。在相同的观测条件下间接法确定湍流通量以Bowen比法和组合法误差最小,实例计算表明组合法的精度最高。 相似文献
7.
Gordon A. McBean 《Boundary-Layer Meteorology》1973,4(1-4):265-274
In order to parameterize the surface fluxes, it is desirable first to understand the turbulent transfer processes. In this paper the spectral correlation coefficients for momentum, heat and moisture transfer from the Ladner, BOMEX and Suffield experiments are compared. Near-neutral to unstable stratifications were examined. Differences between heat and momentum transfer processes were found and the differences increased with instability. The transfer of a passive scalar, such as moisture was found to be dependent on the active-scalar/passive-scalar correlation. 相似文献
8.
Y. Shao M. Sogalla M. Kerschgens W. Brücher 《Meteorology and Atmospheric Physics》2001,78(3-4):157-181
Summary
In this paper, we examine the effects of land-surface heterogeneity on the calculation of surface-energy and momentum fluxes
in a meso-scale atmospheric model. A series of numerical experiments has been carried out with a combination of different
resolutions for the atmosphere and the land surface, which allows an examination of the aggregation and dynamic effects associated
with land-surface heterogeneity. The numerical results show that for a given atmospheric model resolution, increased land-surface
resolution leads to better estimates of surface-energy and momentum fluxes, and for a given land-surface resolution, increased
atmospheric model resolution also improves the estimates of these fluxes. This latter result contradicts the prevailing view
that subgrid variation in atmospheric data plays only a minor role in estimating the fluxes. It is also shown that subgrid
land-surface heterogeneity leads to increased turbulent fluctuations. The responsible mechanisms of this effect are both the
subgrid variation of surface-energy fluxes and their impact upon the development of convective cells. It is suggested that
subgrid atmospheric motions induced by surface heterogeneity may be an important factor which needs to be considered in subgrid
closure schemes for atmospheric models.
Received August 28, 2000/Revised June 1, 2001 相似文献
9.
利用2006年南京地区边界层外场观测资料对摩擦速度(u*)和摩擦温度(θ*)的几种计算方案进行了比较.u*计算方案的比较结果表明:在不稳定条件下,Pleim方案计算结果同实测值相比,二者在量值及变化趋势上都有较好的一致性;而在稳定条件下,计算结果较差,为此本文给出了一个新的计算方案,结果表明,改进方案有效的提高了u*计算精度,平均相对误差由56%降低到21%.θ*计算方案的比较结果表明:基于动力粗糙度和热力粗糙度相等的Lee方案计算误差较大,而引入阻尼项的Wesely方案计算结果较前者有明显改进. 相似文献
10.
In this paper we revise the similarity theory for the stably stratified atmospheric boundary layer (ABL), formulate analytical
approximations for the wind velocity and potential temperature profiles over the entire ABL, validate them against large-eddy
simulation and observational data, and develop an improved surface flux calculation technique for use in operational models. 相似文献
11.
G. Pigeon A. Lemonsu C. S. B. Grimmond P. Durand O. Thouron V. Masson 《Boundary-Layer Meteorology》2007,124(2):269-290
This study quantifies the processes that take place in the layer between the mean building height and the measurement level
of an energy balance micrometeorological tower located in the dense old core of a coastal European city. The contributions
of storage, vertical advection, horizontal advection and radiative divergence for heat are evaluated with the available measurements
and with a three-dimensional, high-resolution meteorological simulation that had been evaluated against observations. The
study focused on a summer period characterized by sea-breeze flows that affect the city. In this specific configuration, it
appears that the horizontal advection is the dominant term. During the afternoon when the sea breeze is well established,
correction of the sensible heat flux with horizontal heat advection increases the measured sensible heat flux up to 100 W m−2. For latent heat flux, the horizontal moisture advection converted to equivalent latent heat flux suggests a decrease of
50 W m−2. The simulation reproduces well the temporal evolution and magnitude of these terms. 相似文献
12.
13.
几种计算湍流能量和通量方法的比较 总被引:1,自引:0,他引:1
本文利用超声脉动风速仪和白金丝脉动温度仪,分别测量了三维风速u、v、w和温度T的瞬时脉动值.根据这些风、温高频测量值,用几种不同的计算方法计算了湍流能量和动量、热量通量.计算结果表明,由于大气中湍涡尺度很宽,对于不同尺度的湍流量,选用合理的计算方法,能够得到正确的计算结果,并节省计算时间. 相似文献
14.
15.
The interaction of turbulent and radiative transfer applied to a number of plausible atmospheric situations in the surface layer under the stably stratified condition is discussed.The calculated results show that the long-wave radiative flux has a great influence upon the thermal structure of the surface layer, and that it usually acts in such a way as to weaken the thickness of the constant turbulent heat flux layer. In the case of low wind velocities and strongly stable stratifications, the thickness of the turbulent heat flux layer will become very thin and/or inexistent. 相似文献
16.
If oceanic models are to be driven with transient atmospheric input, data from standard daily analyses or from an atmospheric GCM simulation can be used. The question arises whether these “FF-data” (FF = field forcing) are appropriate to be used as a realistic oceanic forcing in the form of wind stress and turbulent heat fluxes.A series of different FF-data sets is compared with respective “LF-data” (LF = local forcing) derived from in situ weathership observations. We believe these LF data to be the most accurate and reliable long year maritime time series. The study is restricted to 8 Atlantic weatherships and January conditions and to fields obtained with the Hamburg University GCM or derived from analyses of the German Weather Service (DWD).It turns out that DWD based FF data sets are suitable only if long year mean values are required. In general, the interannual and synoptic scale variability is too small for all FF data sets. With respect to the windstress, the empirical formulae to obtain the surface wind (from the sea level pressure field) together with the usage of a windspread dependent drag coefficient yield the best though still unsatisfying results. The approach using generalized similarity theory gives worse results with respect to the synoptic scale and interannual variability.The GCM simulated data set is systematically biased over wide regions which is partly due to a shift in the model's quasistationary Icelandic Low and an increased temperature at the model's lowest level. The transients are simulated at some positions even poorer than those analysed by the DWD, but at other positions superior though still weaker than the LF data's. 相似文献
17.
Experimental determination of turbulent fluxes over the heterogeneous LITFASS area: Selected results from the LITFASS-98 experiment 总被引:1,自引:0,他引:1
F. Beyrich S. H. Richter U. Weisensee W. Kohsiek H. Lohse H. A. R. de Bruin Th. Foken M. Göckede F. Berger R. Vogt E. Batchvarova 《Theoretical and Applied Climatology》2002,73(1-2):19-34
Summary ?During the LITFASS-98 experiment, local flux measurements were performed over five different types of underlying surface
(grass, barley, triticale, pine forest, water) in a heterogeneous landscape using eddy covariance and profile techniques over
a three week time period in June, 1998. Estimates of the area-integrated sensible heat flux during daytime were obtained from
continuous measurements with a large aperture scintillometer (LAS) along a 4.7 km path. The calculation of a mean diurnal
cycle of the fluxes during the experiment revealed significant differences between the main land use classes. A land-use weighted
average of the sensible heat flux was found to be in good agreement with the LAS based estimate, which in turn was supported
by other regionally integrated flux estimates from budget considerations and aircraft measurements for a few case studies.
The profiles of turbulent quantities measured along a 99 m-tower significantly deviate from “idealised” profiles measured
over homogeneous terrain. Peculiarities in the profile structure could be attributed to the heterogeneity of the terrain,
namely to the differences in the surface characteristics of the footprint areas for the different tower levels.
Received June 6, 2001; revised January 15, 2002; accepted April 4, 2002 相似文献
18.
The use of high frequency atmospheric turbulence properties (inertial subrange spectra, structure function parameters or dissipation rates) to infer surface fluxes of momentum, sensible heat and latent heat is more practical for most ocean going platforms than direct covariance measurement. The relationships required to deduce the fluxes from such data are examined in detail in this paper and several ambiguities and uncertainties are identified. It is noted that, over water, data on water vapor properties (the dimensionless functions for the mean profile, the structure function parameter and the variance transport term) are extremely sparse and the influence of sea spray is largely unknown. Special attention is given to flux estimation on the basis of the structure function formalism. Existing knowledge about the relevant similarity functions is summarized and discussed in light of the ambiguities identified above. 相似文献
19.
Turbulent fluctuations of wind and temperature were measured using a three-component sonic anemometer at 8 m on a 30 m micro-meteorological tower erected at the Indian Institute of Technology (IIT) Kharagpur (22.3° N, 87.2° E), India, as part of the Monsoon Trough Boundary Layer Experiment (MONTBLEX). Diurnal and nocturnal variations of fluxes of sensible heat and momentum were estimated by the eddy correlation technique from 42 observations, each of 10 min duration during 6–8 July in the monsoon season of 1989. The estimated heat flux shows a diurnal trend while the momentum flux shows variability but no particular trend. The nocturnal heat flux changes sign intermittently.Fluctuations of vertical wind velocity
wand temperature when normalised with the respective scaling parameters u
*and * are found to scale with Z/L in accordance with the Monin-Obukhov similarity hypothesis: % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaeqOXdy2aaS% baaSqaaiaadEhaaeqaaOGaamiEaiaacIcacaWGAbGaai4laiaadYea% caGGPaWaaWbaaSqabeaacaaIXaGaai4laiaaiodaaaaaaa!3FE8!\[\phi _w x(Z/L)^{1/3} \], % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaeqOXdy2aaS% baaSqaaiabeI7aXbqabaGccaWG4bGaaiikaiaadQfacaGGVaGaamit% aiaacMcadaahaaWcbeqaaiaaigdacaGGVaGaaG4maaaaaaa!40A2!\[\phi _\theta x(Z/L)^{1/3} \] during unstable conditions and % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaeqOXdy2aaS% baaSqaaiaadEhaaeqaaOGaamiEaiaacIcacaWGAbGaai4laiaadYea% caGGPaaaaa!3D90!\[\phi _w x(Z/L)\], % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaeqOXdy2aaS% baaSqaaiabeI7aXbqabaGccaWG4bGaaiikaiaadQfacaGGVaGaamit% aiaacMcadaahaaWcbeqaaiabgkHiTiaaigdaaaaaaa!401F!\[\phi _\theta x(Z/L)^{ - 1} \] during stable conditions. Correlation coefficients for heat and momentum flux % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaeq4SdC2aaS% baaSqaaiaadEhacqaH4oqCaeqaaaaa!3A71!\[\gamma _{w\theta } \] and
uwshow stability dependence. For unstable conditions, % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaeq4SdC2aaS% baaSqaaiaadEhacqaH4oqCaeqaaaaa!3A71!\[\gamma _{w\theta } \] increases with increasing ¦Z/L¦ whereas
uwdecreases. During stable conditions, % MathType!MTEF!2!1!+-% feaafeart1ev1aaatCvAUfeBSjuyZL2yd9gzLbvyNv2CaerbuLwBLn% hiov2DGi1BTfMBaeXatLxBI9gBaerbd9wDYLwzYbItLDharqqtubsr% 4rNCHbGeaGqiVu0Je9sqqrpepC0xbbL8F4rqqrFfpeea0xe9Lq-Jc9% vqaqpepm0xbba9pwe9Q8fs0-yqaqpepae9pg0FirpepeKkFr0xfr-x% fr-xb9adbaqaaeGaciGaaiaabeqaamaabaabaaGcbaGaeq4SdC2aaS% baaSqaaiaadEhacqaH4oqCaeqaaaaa!3A71!\[\gamma _{w\theta } \] decreases with increasing Z/L while
uwdecreases very slowly from a value -0.36 to -0.37. 相似文献
20.
湍流通量计算方法和误差的比较研究 总被引:3,自引:1,他引:3
近地层的风、温、湿梯度以及辐射和土壤热通量资料在过去的几十年间被广泛地用于计算陆-气感热、潜热通量.然而,不同的计算方法之间存在一些差异,随意的选用可能会造成计算结果存在较大的误差.文中利用绿洲系统能量与水分循环过程观测试验的2005年6月甘肃金塔绿洲中部观测资料,在分析了观测期间近地层微气象特征的基础上,对鲍恩比法、空气动力学法(包含两种不同计算方案)和变分法计算的绿洲农田下垫面的湍流通量进行了比较,并通过敏感性实验和理论分析探讨了不同方法间计算结果的差异和误差的来源.结果表明:不同方法计算的湍流通量特征存在明显差异.鲍恩比法从理论上满足能量平衡关系,但在昼夜交替和夜晚时出现了计算不稳定现象,因此在这些时段不适用.变分法避免了鲍恩比法计算夜间湍流通量的不稳定性,而且二者计算的白天湍流通量有较好的相关性;同时变分法由于加入了辐射和土壤热通量信息,明显改善了空气动力学法白天的能量平衡状况;变分法计算得到的潜热通量对辐射和微气象条件有较为合理的响应;对数据误差的敏感性试验表明,鲍恩比法和空气动力学法应用于绿洲下垫面上对观测误差较为敏感,而变分法相对比较稳定.进一步的分析表明,鲍恩比法在-2<β<0的范围内由于方法本身局限而适用性较差;而空气动力学方法计算结果的差异和误差来源于所应用的相似性函数.因而与鲍恩比法和空气动力学法计算的湍流通量值相比较,变分法的计算结果更加合理和稳定,在绿洲下垫面有较好的适用性.该文研究方法和结果可为这些方法的使用提供参考. 相似文献