首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
The effectiveness of constructing a geogrid-reinforced and pile supported embankment on soft ground to reduce differential settlement has been studied by pilot scale field tests and numerical analysis. Three-by-three pile groups with varying pile spacing were driven into a layer of soft ground, and a layer of geogrid was used as reinforcement over each pile group. Further, a 2-D numerical analysis has been conducted using the computer program FLAC 2D. The mechanisms of load transfer can be considered as a combination of embankment soil arching, geogrid tension, and stress transfer due to the difference in stiffness between pile and soft ground. Based on the pilot scale field tests and results of numerical analysis, we find that the geosynthetic reinforcement slightly interferes with soil arching, and helps reduce differential settlement of the soft ground. Also, the most effective load transfer and vertical stress reduction at the midspan between piles occurs when the pile cap spacing index D/b (D: pile cap spacing, b: diameter of pile) is 3.0.  相似文献   

2.
The effectiveness of constructing a geogrid-reinforced and pile supported embankment on soft ground to reduce differential settlement has been studied by pilot scale field tests and numerical analysis. Three-by-three pile groups with varying pile spacing were driven into a layer of soft ground, and a layer of geogrid was used as reinforcement over each pile group. Further, a 2-D numerical analysis has been conducted using the computer program FLAC 2D. The mechanisms of load transfer can be considered as a combination of embankment soil arching, geogrid tension, and stress transfer due to the difference in stiffness between pile and soft ground. Based on the pilot scale field tests and results of numerical analysis, we find that the geosynthetic reinforcement slightly interferes with soil arching, and helps reduce differential settlement of the soft ground. Also, the most effective load transfer and vertical stress reduction at the midspan between piles occurs when the pile cap spacing index D/b (D: pile cap spacing, b: diameter of pile) is 3.0.  相似文献   

3.
Behavior of Pile Group with Elevated Cap Subjected to Cyclic Lateral Loads   总被引:1,自引:1,他引:0  
The pile group with elevated cap is widely used as foundation of offshore structures such as turbines, power transmission towers and bridge piers, and understanding its behavior under cyclic lateral loads induced by waves, tide water and winds, is of great importance to designing. A large-scale model test on 3×3 pile group with elevated cap subjected to cyclic lateral loads was performed in saturated silts. The preparation and implementation of the test is presented. Steel pipes with the outer diameter of 114 mm, thickness of 4.5 mm, and length of 6 m were employed as model piles. The pile group was cyclic loaded in a multi-stage sequence with the lateral displacement controlled. In addition, a single pile test was also conducted at the same site for comparison. The displacement of the pile cap, the internal forces of individual piles, and the horizontal stiffness of the pile group are presented and discussed in detail. The results indicate that the lateral cyclic loads have a greater impact on pile group than that on a single pile, and give rise to the significant plastic strain in the soil around piles. The lateral loads carried by each row of piles within the group would be redistributed with loading cycles. The lateral stiffness of the pile group decreases gradually with cycles and broadly presents three different degradation patterns in the test. Significant axial forces were measured out in some piles within the group, owing to the strong restraint provided by the cap, and finally lead to a large settlement of the pile group. These findings can be referred for foundation designing of offshore structures.  相似文献   

4.
螺旋桩芯劲性复合桩(helix stiffened cement mixing pile,简称HSCM桩)是一种新型复合桩,其成桩工艺会对桩身及其承载性能有较大影响。为验证HSCM桩在软黏土中同步旋进注浆工艺的可行性,并研究其成桩参数对抗压承载性能的影响,设计了2组缩尺模型试验,包括不同叶片数量与钻进速度的HSCM桩与对比螺旋桩。通过在高岭土制备的软黏土中成桩,并进行抗压承载性能及桩身几何尺寸测试,分析HSCM桩的成桩参数与水泥土桩身间的关系。试验结果表明:同步旋进注浆工艺能够在螺旋桩周围形成倒圆台状的水泥土桩身,水泥土桩身的平均黏结直径约为叶片直径的1.17~1.35倍;适当增加叶片数量能够使水泥与土体充分拌和,提高水泥土桩身的完整性与连续性,以改善HSCM桩的成桩质量;钻进速度大幅提高会导致注浆量不足,减小水泥土桩身的黏结直径与刚度;试验条件下HSCM桩的抗压极限承载力是螺旋桩的3.83~3.93倍,桩径扩大提高了侧摩阻力,注浆工艺加固并提高了土体强度,弥补了叶片在旋进过程中扰动土体造成强度降低的问题。  相似文献   

5.
Abstract

Pipes buried in soft ground can be damaged due to the vertical and lateral movement of the ground during the construction of the embankment. To investigate such a movement of the soft ground, full-scale tests using embankment piles and stabilizing piles were conducted for 70?days. A pile-supported embankment has been used to reduce the deformation of soft ground by transferring the embankment load through piles to the firm layer below the soft ground, whereas stabilizing piles have been employed to resist the lateral earth pressure that is induced in soft ground by embankment loads. The Coupling Area (CA), which was defined as the quantitative index to determine the resistance effect of both settlement and lateral flow of the soft ground when the embankment was reinforced, is adapted. The analysis results of the CA indicate that the piled embankment was more effective for preventing the damage to buried pipe installed near the embankment, while the stabilizing piles had almost the same effect as the piled embankment when the pipe was buried far away from the embankment.  相似文献   

6.
In this article, two full-scale pile loading tests were conducted to observe the field performance of the super-long bored piles, and a simplified approach for nonlinear analysis of the load-displacement behavior of a single pile was presented. The field tests on piles indicates that, under the maximum test load, more than 70% of the pile top settlement is caused by the compression of pile shaft. For practical purposes, the pile top settlement can be reduced through improving the pile shaft strength. When the load reaches the maximum test load, the proportion of the load carried by the pile tip is approximately 30%. The super-long pile is functioning as an end-bearing friction pile. The skin friction at shallow depth is fully mobilized and decreases from a peak value with increasing load. However, the skin friction of deeper soil is not fully developed due to less relative displacement. Furthermore, a BoxLucas1 model is used to capture the relationship between unit skin friction and pile-soil relative displacement, whereas a hyperbolic model is used to describe the relationship between toe stress and pile base displacement. Based on the BoxLucas1 model and the hyperbolic model, a load transfer method is used to clarify the response of a single pile, and a computational flow chart is developed. The efficiency and accuracy of the present method is verified using the field tests on piles. The proposed simple analytical approach is economical and efficient, resulting in savings in time and cost.  相似文献   

7.
Abstract

An experimental study of the performance of concrete pipe piles during installation under different penetration speeds and static load tests on the piles in sand is presented. The applied jacking force, the amount of pile penetration, length of soil plug formed and ultimate bearing capacity were measured during the model tests. The results showed that the concrete pipe piles were partially plugged and the behavior of the soil plug was significantly affected by the penetration speed. The lower the penetration speed, the larger the soil plug formed which in turn leads to a greater ultimate bearing capacity. The size of soil plug can be evaluated by the m value defined as the ratio of the volume of the soil plug to that of the penetrated pile wall. The relationship between the m value and the penetration speeds can be used to estimate the amount of soil plug and the depth of penetration for an open-ended concrete pipe pile jacked into sand.  相似文献   

8.
Slender piles embedded in soft ground or liquefied soil may buckle under vertical load. In this paper, both small- and large-scale model tests are conducted to investigate the buckling mechanisms of a slender pile and the lateral earth pressure acting on the pile. To observe the buckling of a slender pile, the strain-controlled loading method is adopted to apply a vertical load. When the two ends of a slender pile are hinged, the buckling mechanisms of small- and large-scale model tests are same. It should be noted that this applies only to a system with a small ratio of pile bending stiffness to soil bending stiffness. An applied vertical load increases with an increasing pile head settlement until it reaches the critical buckling load. By further increasing the pile head settlement, the measured load approaches the critical buckling load. In the large-scale model test, the measured lateral earth pressure (i.e., active and passive) acting on the slender pile varies linearly with the lateral pile displacement when the measured range is 3–5?m beneath the ground. A critical buckling calculation method has been adopted to compare with the conventional “m” method. The two-sided earth pressure calculation method can achieve more approximate results with the model test.  相似文献   

9.
Pile foundations subjected to cyclic load is an age-old problem dealt with for decades by geotechnical engineers. The ocean environment necessitates the piles supporting offshore structures to be designed against lateral cyclic loading initiated by wave action. Substantial experimental and analytical investigations have already been conducted by the author and other researchers. The quasi-static load reversal induces deterioration in the strength and stiffness of the soil-pile system introducing progressive reduction in the bearing capacity as well as settlement of the pile foundation, the degree of such degradation has been observed to be a function of the cyclic load parameters and the type of soil. Based on these observations, a design recommendation has been attempted in this paper for piles subjected to cyclic load in cohesive soil.  相似文献   

10.
Abstract

Helical piles have emerged as an attractive foundation system for offshore applications with renewed interest from the offshore community. Significant research gap currently exists in transferring this technology offshore and this paper discusses how existing and emerging knowledge can be successfully used to bridge some of the gaps. We focus on the Coupled Eulerian Lagrangian (CEL) large deformation finite element (LDFE) modelling technique that is commercially available and can be used to model the three-dimensional installation process with consideration of strain rate and softening effects in soft offshore clays. A helical pile of L?=?7.5?m long is modelled with one or two large-diameter helices (D?=?2?m) attached to a central shaft of d?=?0.5?m in diameter.The net effect of strain rate and softening is to increase the installation torque. The measured torque is within the range of 200–400?kN.m for the offshore clay and the pile geometry studied. Additional helices increase the uplift force but to a lesser degree than that of the measured torque. Remoulding induced strength reduction is found to be within the range of 25–33% of the intact clay strength. Issues of extracting and reusing offshore helical pile foundations are discussed.  相似文献   

11.
ABSTRACT

Oil and its derivatives contaminate many soils and not only affect their chemical and biological properties but also their geotechnical properties. As oil contamination may deteriorate the functioning of piles, this paper addresses the effects of oil contamination on soil–pile interactions. Axial compressive bearing capacities of two close-ended, instrumented piles were investigated in different oil-contaminated sand using frustum confining vessel. Three different oils (gasoil, crude oil, and used motor oil) at different contamination levels were considered and using some strain gauges, the toe, shaft, and the net total bearing capacity of piles, as well as load distributions along the pile length, were derived. The results show that the presence of oil between soil particles has considerable adverse effects on bearing capacities of model piles, especially the shaft bearing capacity. The oil viscosity and percentage, as well as the contaminated sand bed thickness around the piles, are the most influential parameters. The higher the oil viscosity and oil content, the lower the values of the piles’ bearing capacities in comparison to the uncontaminated sand. With some modifications on the bearing capacity parameters of CFEM method, a good agreement was observed between measured and calculated bearing capacity values.  相似文献   

12.
Abstract

Open‐pipe piles are widely used for offshore structures. During the initial stage of installation, soil enters the pile at a rate equal to the pile penetration. As penetration continues, the inner soil cylinder may develop sufficient frictional resistance to prevent further soil intrusion, causing the pile to become plugged. The open‐ended pile then assumes the penetration characteristics of a closed‐ended pile. The mode of pile penetration significantly alters the soil‐pile interaction during and after installation. This affects the ultimate static bearing capacity (mainly in granular materials), the time‐dependent pile capacity (in clays), and the dynamic behavior and analysis of the piles.

Following a summary demonstrating the effects of pile plugging, a review of the common view of offshore pile plugging is undertaken. The interpretation of plugging by referring to the average plug length has led to the erroneous conclusion that in most piles significant plugging action does not occur.

Establishment of an analogy between soil samplers and open‐ended piles enabled correct identification of plugging by referring to the incremental changes in plug length. Examination of case histories of plugging of offshore piles revealed that beyond a certain penetration depth‐to‐diameter ratio, most piles are plugged.  相似文献   

13.
Granular piles are frequently used as a method of improving soft grounds as they provide increased bearing capacity and reduce foundation settlements. However, in very soft clayey soils, they may not derive their load-carrying capacity by low confining pressure provided by the surrounding soil. In such circumstances, granular piles may be reinforced with suitable geosynthetic to increase its load-carrying capacity and to reduce excessive bulging. In this study, the performance of small group of geosynthetic-reinforced granular piles (GRGPs) is examined in terms of load-carrying capacity, settlement, and modulus by laboratory model tests. The parameters investigated include modulus of reinforcement material, area replacement ratio (ARR) based on the column diameter and reinforcement length. The results indicated that increasing the modulus of the reinforcement and the ARR based on the column diameter enhances the overall performance of the GRGP group. It was also observed that reinforcement on top portion of the granular pile is sufficient to substantially increase the load-carrying capacity of granular pile group.  相似文献   

14.
桩基础是我国海上风电工程中应用最为广泛的基础形式,其中嵌岩桩因其施工难度大,承载力高备受关注。与其他类型的桩基础不同,嵌岩桩的水平承载力不仅受到围岩强度的影响,更与其成桩质量与灌浆材料的强度相关。采用有限元方法分析了嵌岩深度、桩基直径与壁厚、桩身倾斜度等多种因素对嵌岩桩水平承载力的影响,提出了确定嵌岩桩水平极限抗力的标准。研究表明:桩与围岩间的灌浆环会先于桩身发生破坏,因此可将灌浆环受拉破坏作为判断嵌岩桩达到水平极限承载力的标准;桩身倾斜度对嵌岩桩的水平极限承载力影响较大,直径和壁厚的增加,均能提高桩基的水平承载力。  相似文献   

15.
In this study, the dynamic response of pile foundation in dry sandy soil excited by two opposite rotary machines was considered experimentally. A small scale physical model was manufactured to accomplish the experimental work in the laboratory. The physical model consists of two small motors supplied with eccentric mass (0.012?kg) and eccentric distance (20?mm) representing the two opposite rotary machines, an aluminum shaft as the pile, and a steel plate a pile cap. The experimental work was achieved taking the following parameters into considerations: pile embedment depth ratio (L/d, where L is the pile length and d is its diameter) and operating frequency of the rotary machines. All tests were conducted in medium dense fine sandy soil with 60% relative density. Twelve tests were performed to measure the change in load transferred through the pile’s tip to the underlying soil. To predict precisely the dynamic load that will be induced from the rotary machines, a mini load cell with a capacity of 100?kg was mounted between the aluminum plate (the machine base) and the steel plate (pile cap). The results revealed that, before machine operation, the pile tip load was approximately equal to the static load (machine and pile cap), whereas during machines’ operation, the pile tip load decreased for all embedment depth ratios and operating frequencies. This reduction was due to the action of skin friction that was mobilized along the pile during operation, and as a result the factor of safety against pile bearing failure increases. For all operating frequencies and pile lengths, the factor of safety against bearing failure increased during machines’ operation, where the pile tip load became less than its value before starting operation. During operation, the skin friction resistance mobilized along pile length led to decrease the bearing load.  相似文献   

16.
Static load tests on pile group with prototype size were carried out in order to study the behavior and the working properties of the cap—pile group—soil interaction in the pile group foundation. The soil resistance under the cap, the pile shaft resistance and the tip resistance were measured by installing various measuring gauges. Based on these test results, the cap—pile group—soil interaction characteristics were analyzed. The regulations of the soil reaction on the cap, the shaft resistance and the tip resistance of pile, the mechanism of load transfer have been discussed with comparison to the result of the single pile tests. The bearing capacity of pile group is greater than the sum of the bearing capacity of the single pile obtained from testing in the same site in pile group foundation in the case presented here.  相似文献   

17.
Abstract

Pile foundation is the most popular option for the foundation of offshore wind turbines. The degradation of stiffness and bearing capacity of pile foundation induced by cyclic loading will be harmful for structure safety. In this article, a modified undrained elastic–plastic model considering the cyclic degradation of clay soil is proposed, and a simplified calculation method (SCM) based on shear displacement method is presented to calculate the axial degradated capacity of a single pile foundation for offshore wind turbines resisting cyclic loadings. The conception of plastic zone thickness Rp is introduced to obtain the function between accumulated plastic strain and displacement of soil around pile side. The axial ultimate capacity of single piles under axial cyclic loading calculated by this simplified analysis have a good consistency with the results from the finite element analysis, which verifies the accuracy and reliability of this method. As an instance, the behavior of pile foundation of an offshore wind farm under cyclic load is studied using the proposed numerical method and SCM. This simplified method may provide valuable reference for engineering design.  相似文献   

18.
Abstract

Mono-pile foundations have been widely used for offshore wind turbines principally due to their convenient construction and cost-effective nature. So far, little attention has been paid to large diameter “semi-rigid” piles that have distinct behaviours from flexible or ideally rigid piles. This paper presents a series of centrifuge model tests to study the deforming and bearing characteristics of a 5.9 dia. semi-rigid pile under lateral loadings in kaolin clay. For monotonic loading, a modified p–y curve analysis model considering rotational soil flow near the rotation centre of pile was proposed, highlighting the limitation of classic plane-strain based plasticity models to evaluate the ultimate lateral pile-soil resistance. For cyclic loading, a strong correlation between the degree of soil degradation and cyclic load amplitude was identified. Besides, a degradation factor model, accounting for various cyclic stress levels and soil depths, was proposed, which can be used to assess the accumulative displacement of semi-rigid piles under cyclic loadings in soft clay.  相似文献   

19.
利用室内半模试验和颗粒流数值模拟,揭示多层砂土地基扩底桩单桩抗压承载特性及变形特征。结果表明,通过对比分析极限承载力与H_h/D(持力层厚度与扩大头直径之比)的关系可以看出,单桩的抗压极限承载力随H_h/D逐渐增加,当H_h/D超过2.0时,极限承载力基本不再增加,此时的单桩抗压极限承载力稳定在300.01~303.25 N,是H_h/D=0.5时极限承载力(183.83 N)的1.65倍。扩大头下部土体发生局部压缩-剪切破坏,破坏面从扩大头底面边缘向斜下方扩展,在水平方向影响范围达到最大后逐渐向桩内侧收缩;荷载作用越大,地基破坏区域越大,相应的极限抗压承载力也越大;持力层厚度增加,扩大头分担的荷载比例增大,分担的荷载达到稳定需要的桩顶位移也越大,H_h=0.5 D试验扩大头分担的荷载比例稳定时为60%,对应的桩顶位移约为29 mm;桩顶位移达到33 mm后,H_h=1.0~3.0 D试验稳定在63%~65%之间;通过细观颗粒流理论对砂土移动特性的研究发现,持力层厚度从0.5 D增大至2.0 D,破坏面的起始扩展角度从31°增大至42°。数值模拟研究结果与模型试验数据吻合效果良好,证明该方法分析多层砂土地基扩底桩单桩抗压荷载传递机理是可行的。  相似文献   

20.
李静  史宏达 《海岸工程》2009,28(4):48-58
对我国近年出现的几种新型码头结构的研究进行了综述和分析。其中,遮帘式板桩码头结构减小了作用于前板桩上的土压力,使板桩码头在大水深情况下得以应用;双排大管桩码头结构使大管桩较高的轴向承载力和抗弯强度得到充分发挥;架空直立式码头解决了内河大水位差情况下建造码头的难题;椭圆型沉箱的应用避免了采用2个圆沉箱产生前后不均匀沉降的技术难题。最后,对上述新型结构的应用进行了总结。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏