首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Inversion of band-limited TEM responses   总被引:2,自引:0,他引:2  
It is shown that the electromagnetic (EM) spectrum is characterized by strong amplitude-modulated transmitters operating in the target bandwidth of transient electromagnetic (TEM) measurements. As these transmitters cause significant noise in TEM soundings, it is mandatory to band-limit the input signals to improve the signal-to-noise ratio and thereby the depth of exploration. Band-limitation will distort the TEM responses, which leads to erroneous inversion results if the applied low-pass filters are not accounted for in the inversion scheme. We incorporate the low-pass filters in the inversion scheme and test the inversion approach on theoretical and field data. Inversion of band-limited theoretical responses results in recovery of erroneous resistivity models if the filters are not included in the inversion scheme. By contrast, inversion of band-limited theoretical and field data, for which the applied low-pass filters are included in the inversion scheme, leads to recovery of similar resistivity models, independent of the applied cut-off frequencies.  相似文献   

2.
 A study of the geoelectrical structure of the central part of Piton de la Fournaise volcano (Réunion, Indian Ocean) was made using direct current electrical (DC) and transient electromagnetic soundings (TEM). Piton de la Fournaise is a highly active oceanic basaltic shield and has been active for more than half a million years. Joint interpretation of the DC and TEM data allows us to obtain reliable 1D models of the resistivity distribution. The depth of investigation is of the order of 1.5 km but varies with the resistivity pattern encountered at each sounding. Two-dimensional resistivity cross sections were constructed by interpolation between the soundings of the 1D interpreted models. Conductors with resistivities less than 100 ohm-m are present at depth beneath all of the soundings and are located high in the volcanic edifice at elevations between 2000 and 1200 m. The deepest conductor has a resistivity less than 20 ohm-m for soundings located inside the Enclos and less than 60–100 ohm-m for soundings outside the Enclos. From the resistivity distributions, two zones are distinguished: (a) the central zone of the Enclos; and (b) the outer zone beyond the Enclos. Beneath the highly active summit area, the conductor rises to within a few hundred meters of the surface. This bulge coincides with a 2000-mV self-potential anomaly. Low-resistivity zones are inferred to show the presence of a hydrothermal system where alteration by steam and hot water has lowered the resistivity of the rocks. Farther from the summit, but inside the Enclos, the depth to the conductive layers increases to approximately 1 km and is inferred to be a deepening of the hydrothermally altered zone. Outside of the Enclos, the nature of the deep, conductive layers is not established. The observed resistivities suggest the presence of hydrated minerals, which could be found in landslide breccias, in hydrothermally altered zones, or in thick pyroclastic layers. Such formations often create perched water tables. The known occurrence of large eastward-moving landslides in the evolution of Piton de la Fournaise strongly suggests that large volumes of breccias should exist in the interior of the volcano; however, extensive breccia deposits are not observed at the bottom of the deep valleys that incise the volcano to elevations lower than those determined for the top of the conductors. The presence of the center of Piton de la Fournaise beneath the Plaine des Sables area during earlier volcanic stages (ca. 0.5 to 0.150 Ma) may have resulted in broad hydrothermal alteration of this zone. However, this interpretation cannot account for the low resistivities in peripheral zones. It is not presently possible to discriminate between these general interpretations. In addition, the nature of the deep conductors may be different in each zone. Whatever the geologic nature of these conductive layers, their presence indicates a major change of lithology at depth, unexpected for a shield volcano such as Piton de la Fournaise. Received: 3 November 1999 / Accepted: 15 September 1999  相似文献   

3.
The possibilities of reconstructing two-dimensional (2D) cross sections based on the data of the profile soundings by the transient electromagnetic method (TEM) with a single ungrounded loop are illustrated on three-dimensional (3D) models. The process of reconstruction includes three main steps: transformation of the responses in the depth dependence of resistivity ρ(h) measured along the profile, with their subsequent stitching into the 2D pseudo section; point-by-point one-dimensional (1D) inversion of the responses with the starting model constructed based on the transformations; and correction of the 2D cross section with the use of 2.5-dimensional (2.5D) block inversion. It is shown that single-loop TEM soundings allow studying the geological media within a local domain the lateral dimensions of which are commensurate with the depth of the investigation. The structure of the medium beyond this domain insignificantly affects the sounding results. This locality enables the TEM to reconstruct the geoelectrical structure of the medium from the 2D cross sections with the minimal distortions caused by the lack of information beyond the profile of the transient response measurements.  相似文献   

4.
A tensor magnetotelluric test survey was carried out in the region of Santa Catarina, located in the Chalco sub-basin of the Mexico Basin. The objective was to define the stratification at depth with an emphasis on the geometry of the main aquifer of that region which is partially known from DC resistivity soundings and drilling. High-quality magnetotelluric soundings could be recorded in the immediate vicinity of large urban zones because the sub-surface is very conductive. Interpretation shows that the solid bedrock is located at a depth of at least 800 m to the south and 1300 m to the north; it could, however, be much deeper. Using complementary DC resistivity sounding and well-logging data, three main layers have been defined overlying the bedrock. These layers are, from surface to bottom, an unsaturated zone of sand, volcanic ash and clay about 10 m thick, followed by a very conductive (1.5 ohm·m) 200 m thick layer of sand and ash with intercalated clay, saturated with highly mineralized water, and finally a zone with resistivity increasing gradually to 60 ohm·m. The investigated deep aquifer constitutes most of this third layer. It consists of a sequence of sand, gravel, pyroclastites and mainly fractured basalts. MT resistivity soundings and magnetic transfer functions also indicate that a shallow resistive structure is dipping, from the northwest, into the lacustrine deposits of the basin. This geologic feature is likely to be highly permeable fractured basaltic flows, which provide a channel by which water contaminated by the Santa Catarina landfill may leak into the basin.  相似文献   

5.
One simulation and two field examples from New Jersey illustrate resolution improvement in geoelectrical soundings applied to groundwater exploration. Layered-earth parameter resolution is derived from data obtained with the commonly used methods of resistivity, induced polarization (IP) and transient electromagnetic (TEM) soundings. Resolution improvement is achieved by simultaneous inversion of two or more data sets and by constraining parameters of the inverse problem. A quantitative analysis showing the contribution of IP data to the resolution of geo-electric sections is presented. Simultaneous inversion of simple IP data with conventional resistivity and resistivity-TEM data sets resulted in improved parameter resolution. IP data improved resolution in three ways: (1) by decoupling correlated layered-earth parameters, (2) by adding information to a geological interpretation about a second physical property, namely chargeability, and (3) by increasing the electrical information available.  相似文献   

6.
城市噪音主要指由于城市设施和人类活动 (如电网、管线、通讯设备、建筑物、交通等 )对电磁信号的干扰。克服城市噪音、提高信噪比是保证城市活断层的电磁探测能否成功的关键。因而 ,在福州市活断层的电磁试验探测中 ,噪音观测与分析被列为试验的一项重要内容 ① 。文中将主要讨论不同类型的噪音对高密度电法 (DC)和瞬变电磁法 (TEM)的影响 ,并提出一些实用的解决办法。试验表明 ,影响高密度电法观测质量的主要因素是地下噪音源 ,如地下管道、地下电缆等 ,地面以上噪音的影响相对较小。对于瞬变电磁法 ,不管地面以下还是地面以上的噪音源都将产生影响。但是 ,只要仪器的性能好 ,对不同噪音源采取相应的措施 ,可以获得满意的结果  相似文献   

7.
During the past two decades, the diagnosis and monitoring of polluted sites have become more important. Urban sites are particularly difficult to study, because they are contaminated with various pollutants, and there is a large physical and chemical heterogeneity. The heterogeneity comes from the landfilling of various solid wastes and remolded soil (endogenous or exogenous) from which they were constituted over time. Traditional techniques such as wells monitoring, are often insufficient to evaluate the extension of soil contamination.This is why we proposed a geoelectrical methodology from the fastest to the most information rich technique, showing all carry out and acquisition times: electromagnetic low frequency conductivity mapping, electrical resistivity profiles, chargeability profiles and spectral induced polarization (SIP) soundings. This strategy has been successfully applied to an urban site located in the Paris Basin (France). A conductivity map in relation with geochemical and lithological informations should provide us information to implement electrical resistivity and chargeability profiles. The latter allowed us to differentiate 3 main anomaly zones that have been determined. As interpretation of chargeability profiles is difficult, because it integrates polarization mechanisms with different relaxation times, we add spectral induced polarization soundings that provide us information concerning the contaminant nature. We determined the extension of an organic phase, and of 2 highly mineralized zones that could be linked to biodegraded and/or with pyrite areas. That theory is consistent with groundwater analysis and SIP data.The conclusion is that the suggested methodology is well suited to the study of urban contaminated sites including several different pollutants.  相似文献   

8.
Global warming is likely modifying the hydrological cycle of forested watersheds. This report set as objectives to: a) assess the hydrological variables interception loss, I, potential and actual evapo-transpiration, E, Et, runoff, Q, and soil moisture content, θ; b) evaluate whether these variables are presenting consistent trends or oscillations that can be associated to global warming or climate variability; and c) relate θ to the number of wildfires and the burned area in Durango, Mexico. A mass balance approach estimated daily variables of the water cycle using sub-models for I and Et to calculate Q and θ for a time series from 1945 to 2007. Regression and auto-regressive and moving averaging (ARIMA) techniques evaluated the statistical significance of trends. The cumulative standardized z value magnified and ARIMA models projected statistically similar monthly and annual time series data of all variables of the water cycle. Regression analysis and ARIMA models showed monthly and annual P, I, E, and Et, Q, and θ do not follow consistent up or downward linear tendencies over time with statistical significance; they rather follow oscillations that could be adequately predicted by ARIMA models (r2 ≥ 0.70). There was a consistent statistical association (p ≤ 0.05) of θ with the number of wildfires and the area burned regardless of the different spatial scales used in evaluating these variables. The analysis shows seasonal variability is increasing over time as magnifying pulses of dryness and wetness, which may be the response of the hydrological cycle to climate change. Further research must center on using longer time series data, testing seasonal variability with additional statistical analysis, and incorporating new variables in the analysis.  相似文献   

9.
A simple scaling relationship is shown to facilitate comparison, correlation and integration of data recorded using the common experimental configurations in electrical and electromagnetic depth sounding. Applications of the scheme to field data from typical geological and landfill environments show that it is robust and, where transient electromagnetic (TEM) data are available, enables easy identification and quantification of electrical static shift (galvanic distortion) in magnetotelluric and direct current (DC) sounding curves. TEM‐based procedures are suggested for both the direct removal of static shift in DC sounding curves and effective joint data inversion with the most‐squares criterion in the presence of static shift. A case study of aquifer characterization using sounding data from borehole sites in the Vale of York in England shows that static shift is a common problem in this glacial‐covered terrain and demonstrates the effectiveness of the proposed joint DC‐TEM inversion strategy in handling distorted soundings.  相似文献   

10.
The magnetotelluric (MT) method has been applied to the determination of the deep resistivity structure of the northeastern margin of the Parnaiba Basin. Transient electromagnetic (TEM) and MT data were collected in early 1999 along a 95 km long N–S line, extending from the coast across the projected subcrop position of a discontinuous fault found to the west of the study area that is believed to be a possible basin‐bounding fault. The MT data were processed to yield the TE‐ and TM‐mode responses and then corrected for static shift using central‐loop and single‐loop TEM data, respectively. Regularized 2D MT inversion was subsequently undertaken using a structured initial model with the near‐surface constrained by TEM inversion results. As a consistency check, we performed another set of 2D inversions using different smooth initial models. The various optimal 2D inversion models show clearly the presence of a major basement trough, over 2 km deep, located about 70 km from the coast. We interpret it as possibly marking the main basin margin and suggest that it may have implications for groundwater resource development in the area.  相似文献   

11.
高温超导磁强计在瞬变电磁法中的应用研究   总被引:3,自引:1,他引:2       下载免费PDF全文
通过对高温超导磁强计的不断完善,研制出了适合在瞬变电磁法中使用的高温超导磁强计,实现了在瞬变电磁法中直接测量磁场的目的.同时开展了瞬变电磁法感应磁场的数据处理与解释技术研究,开发了瞬变电磁法感应磁场的电性成像软件,可以对使用高温超导磁强计作传感器测得的瞬变电磁感应磁场数据进行处理与电性成像.野外实验表明:高温超导磁强计工作稳定,在瞬变电磁法中使用高温超导磁强计比使用感应线圈做传感器提高了勘探深度.  相似文献   

12.
《Geofísica Internacional》2014,53(3):333-341
Escollos Alijos is a large seamount located in the NE Pacific Ocean about 300 km off the Baja California Peninsula. Geochronology and geochemical analysis of volcanic rocks capping the seamount indicate recent magmatism that resulted from extensive differentiation of a mildly alkalic basalt parent magma.Escollos Alijos is located towards the eastern edge of a long-wavelength geoid undulation minimum, of up to -47 m with respect of the WGS84 ellipsoid, which extends over the northeastern Pacific Ocean. Subtracting from the geoid undulation its long-wavelength component and the undulation due to the seamount topography itself, a negative undulation anomaly persists that indicates a mass deficit at depth. Linear inversion of the undulation anomaly yields a region characterized by a negative density contrast, localized under the seamount at a depth between 9 and 13 km.The age and chemical composition of Escollos Alijos, and the inferred mass deficit suggest magma trapped between the oceanic crust and the uppermost mantle, which explains the magmatic activity in recent times.  相似文献   

13.
An attempt to resolve non-uniqueness in the interpretation of transient electromagnetic (TEM) sounding data using measured data alone is made. It is shown in the various examples studied that sufficiently early time measurements can be the determining factor in reducing the ambiguity caused by model equivalence. The early delay times thus play a dual role in transient soundings: they are responsible for resolving shallow structures and they may eliminate the ambiguity in the interpretation of geoelectric parameters of deeper targets. This is illustrated by the results of a follow-up TEM survey at the Dead Sea coast of Israel where the use of supplementary early time measurements allowed non-uniqueness in the determination of the depth to fresh/saline groundwater interface to be resolved.  相似文献   

14.
We present a new approach to polarization analysis of seismic noise recorded by three-component seismometers.It is based on statistical analysis of frequency-dependent particle motion properties determined from a large number of time windows via eigenanalysis of the 3-by-3,Hermitian,spectral covariance matrix.We applied the algorithm to continuous data recorded in 2009 by the seismic station SLM,located in central North America.A rich variety of noise sources was observed.At low frequencies (0.05 Hz) we observed a tilt-related signal that showed some elliptical motion in the horizontal plane.In the microseism band of 0.05-0.25 Hz,we observed Rayleigh energy arriving from the northeast,but with three distinct peaks instead of the classic single and double frequency peaks.At intermediate frequencies of 0.5-2.0 Hz,the noise was dominated by non-fundamental-mode Rayleigh energy,most likely P and Lg waves.At the highest frequencies (3 Hz),Rayleigh-type energy was again dominant in the form of Rg waves created by nearby cultural activities.Analysis of the time dependence of noise power shows that a frequency range of at least 0.02-1.0 Hz (much larger than the microseism band) is sensitive to annual,meteorologically induced sources of noise.  相似文献   

15.
A magnetotelluric survey was carried out in order to contribute to the definition of the deep structure of the Phlegraean Fields area affected by the bradyseismic crisis begun in the summer 1982. In a preliminary campaign carried out in autumn 1983, the MT measurements were made in eight sites, located between 0.3 and 5 km from the Harbour of Pozzuoli and affected by different degrees of uplift.In a second campaign (autumn, 1984) seven of the first eight MT soundings were repeated and four new sites were investigated, one of which located in a stable zone 10 km away from Pozzuoli.MT measurements show the presence of a thick conductive layer (<1 m) thinned underneath the town of Pozzuoli, where its top reaches the minimum depth (1.2–2 km). The upper horizon of this layer has a greater concavity than that produced by surface deformation. Below the conductive layer, the substratum became progressively more resistive with depth. This resistive basement is well defined in the soundings located far away from Pozzuoli. Here, on the contrary, a zone or body much more conductive than its surroundings is detected. This conductive body could correspond to a high temperature magmatic intrusion, probably already solidified, with a rough cylindrical shape with a base diameter of 1.5±0.5 km.Introducing into the obtained model the depth of the conductive horizon desumed from the deep geothermal wells, the top of the intrusive body would lye at 3–4 km depth.A small uplift of this body related to tectonic readjustments eventually induced by strong earthquakes recently occurred in near zones could explain the surface deformation observed during the present bradyseismic crisis.  相似文献   

16.
The inversion of induced‐polarization parameters is important in the characterization of the frequency electrical response of porous rocks. A Bayesian approach is developed to invert these parameters assuming the electrical response is described by a Cole–Cole model in the time or frequency domain. We show that the Bayesian approach provides a better analysis of the uncertainty associated with the parameters of the Cole–Cole model compared with more conventional methods based on the minimization of a cost function using the least‐squares criterion. This is due to the strong non‐linearity of the inverse problem and non‐uniqueness of the solution in the time domain. The Bayesian approach consists of propagating the information provided by the measurements through the model and combining this information with a priori knowledge of the data. Our analysis demonstrates that the uncertainty in estimating the Cole–Cole model parameters from induced‐polarization data is much higher for measurements performed in the time domain than in the frequency domain. Our conclusion is that it is very difficult, if not impossible, to retrieve the correct value of the Cole–Cole parameters from time‐domain induced‐polarization data using standard least‐squares methods. In contrast, the Cole–Cole parameters can be more correctly inverted in the frequency domain. These results are also valid for other models describing the induced‐polarization spectral response, such as the Cole–Davidson or power law models.  相似文献   

17.
Electromagnetic soundings with the fields of natural (magnetotelluric (MT), and audio magnetotelluric (AMT)) and high-power controlled sources have been carried out in the region of the SG-6 (Tyumen) and SG-7 (En-Yakhin) superdeep boreholes in the Yamal-Nenets autonomous district (YaNAD). In the controlled-source soundings, the electromagnetic field was generated by the VL Urengoi-Pangody 220-kV industrial power transmission line (PTL), which has a length of 114 km, and ultralow-frequency (ULF) Zevs radiating antenna located at a distance of 2000 km from the signal recording sites. In the soundings with the Urengoi-Pangody PTL, the Energiya-2 generator capable of supplying up to 200 kW of power and Energiya-3 portable generator with a power of 2 kW were used as the sources. These generators were designed and manufactured at the Kola Science Center of the Russian Academy of Sciences. The soundings with the Energiya-2 generator were conducted in the frequency range from 0.38 to 175 Hz. The external generator was connected to the PTL in upon the agreement with the Yamal-Nenets Enterprise of Main Electric Networks, a branch of OAO FSK ES of Western Siberia. The connection was carried out by the wire-ground scheme during the routine maintenance of PTL in the nighttime. The highest-quality signals were recorded in the region of the SG-7 (En-Yakhin) superdeep borehole, where the industrial noise is lowest. The results of the inversion of the soundings with PTL and Zevs ULF transmitter completely agree with each other and with the data of electric logging. The MT-AMT data provide additional information about the deep structure of the region in the low-frequency range (below 1Hz). It is established that the section of SG-6 and SG-7 boreholes contains conductive layers in the depth intervals from 0.15 to 0.3 km and from 1 to 1.5 km. These layers are associated with the variations in the lithological composition, porosity, and fluid saturation of the rocks. The top of the poorly conductive Permian-Triassic complex is identified at a depth of about 7 km. On the basis of the MT data in the lowest frequency band (hourly and longer periods) with the observations at the Novosibirsk observatory taken into account, the distribution of electric resistivity up to a depth of 800 km is reconstructed. This distribution can be used as additional information when calculating the temperature and rheology of the lithosphere and upper mantle in West Siberia. The results of our studies demonstrate the high potential of the complex electromagnetic soundings with natural and controlled sources in the study of deep structure of the lithosphere and tracing deep oil-and-gas-bearing horizons in the sedimentary cover of the West Siberian Platform within the Yamal-Nenets autonomous district.  相似文献   

18.
The feasibility of electromagnetic gradiometer measurements   总被引:1,自引:0,他引:1  
The quantities measured in transient electromagnetic (TEM) surveys are usually either magnetic field components or their time derivatives. Alternatively it might be advantageous to measure the spatial derivatives of these quantities. Such gradiometer measurements are expected to have lower noise levels due to the negative interference of ambient noise recorded by the two receiver coils. Error propagation models are used to compare quantitatively the noise sensitivities of conventional and gradiometer TEM data. To achieve this, eigenvalue decomposition is applied on synthetic data to derive the parameter uncertainties of layered-earth models. The results indicate that near-surface gradient measurements give a superior definition of the shallow conductivity structure, provided noise levels are 20–40 times smaller than those recorded by conventional EM instruments. For a fixed-wing towed-bird gradiometer system to be feasible, a noise reduction factor of at least 50–100 is required. One field test showed that noise reduction factors in excess of 60 are achievable with gradiometer measurements. However, other collected data indicate that the effectiveness of noise reduction can be hampered by the spatial variability of noise such as that encountered in built-up areas. Synthetic data calculated for a vertical plate model confirm the limited depth of detection of vertical gradient data but also indicate some spatial derivatives which offer better lateral resolution than conventional EM data. This high sensitivity to the near-surface conductivity structure suggests the application of EM gradiometers in areas such as environmental and archaeological mapping.  相似文献   

19.
Determination of impedances is necessary in order to eliminate some shortcoming of our knowledge about structures of the exciting source fields and their fickleness. The experimental impedances for induction soundings result from the impedance boundary conditions or heuristic models. The simplified models give just a rough idea of their domain of applicability. Impedances can depend on many factors, including the exciting field structures of several source types which are present in the period range of the mantle soundings (104−4×108 s). The problem in the mantle investigations arises if impedances measured by different methods have to be jointly inverted in order to essentially prolongate the analyzed period range and hence to increase the reliability and depth of induction soundings on land. The subject of our work is an analysis of the known magnetotelluric and magnetovariation impedances to suggest a physically substantiated approach for their joint inversions.  相似文献   

20.
Buried Quaternary valleys in Denmark are complex structures filled with various deposits consisting primarily of glacio-lacustrine clay, till and meltwater sand, and gravel. The valleys are important geophysical targets, because they often contain significant volumes of groundwater used for public water supply. About 700 km of buried valley structures have been imaged in the western part of Denmark by the transient electromagnetic (TEM) method. The ability to map the valleys depends primarily on valley geometry, infill architecture and the resistivity of the fill sediments as well as the substratum. One-dimensional (1-D) inversion models of the TEM soundings have been used to construct contour maps of 20 m average resistivities and depth to a good conductor, which provide images for geological interpretation. Images of buried valley morphology, fill properties, infill architecture, such as cut-and-fill structures, valley distribution and valley generations, are characterized for case studies from Hornsyld, Holstebro and the Vonsild/Agtrup areas of Denmark.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏