首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A detailed seasonal study of soil vapor intrusion at a cold climate site with average yearly temperature of 1.9 °C was conducted at a house with a crawlspace that overlay a shallow dissolved‐phase petroleum hydrocarbon (gasoline) plume in North Battleford, Saskatchewan, Canada. This research was conducted primarily to assess if winter conditions, including snow/frost cover, and cold soil temperatures, influence aerobic biodegradation of petroleum vapors in soil and the potential for vapor intrusion. Continuous time‐series data for oxygen, pressure differentials, soil temperature, soil moisture, and weather conditions were collected from a high‐resolution monitoring network. Seasonal monitoring of groundwater, soil vapor, crawlspace air, and indoor air was also undertaken. Petroleum hydrocarbon vapor attenuation and biodegradation rates were not significantly reduced during low temperature winter months and there was no evidence for a significant capping effect of snow or frost cover that would limit oxygen ingress from the atmosphere. In the residual light nonaqueous phase liquid (LNAPL) source area adjacent to the house, evidence for biodegradation included rapid attenuation of hydrocarbon vapor concentrations over a vertical interval of approximately 0.9 m, and a corresponding decrease in oxygen to less than 1.5% v/v. In comparison, hydrocarbon vapor concentrations above the dissolved plume and below the house were much lower and decreased sharply within a few tens of centimeters above the groundwater source. Corresponding oxygen concentrations in soil gas were at least 10% v/v. A reactive transport model (MIN3P‐DUSTY) was initially calibrated to data from vertical profiles at the site to obtain biodegradation rates, and then used to simulate the observed soil vapor distribution. The calibrated model indicated that soil vapor transport was dominated by diffusion and aerobic biodegradation, and that crawlspace pressures and soil gas advection had little influence on soil vapor concentrations.  相似文献   

2.
The occurrence of aerobic biodegradation in the vadose zone between a subsurface source and a building foundation can all-but eliminate the risks from methane and petroleum vapor intrusion (PVI). Understanding oxygen availability and the factors that affect it (e.g., building sizes and their distribution) are therefore critical. Uncovered ground surfaces allow oxygen access to the subsurface to actively biodegrade hydrocarbons (inclusive of methane). Buildings can reduce the net flux of oxygen into the subsurface and so reduce degradation rates. Here we determine when PVI and methane risk is negligible and/or extinguished; defined by when oxygen is present across the entire sub-slab region of existing or planned slab-on-ground buildings. We consider all building slab sizes, all depths to vapor sources and the effect of spacings between buildings on the availability of oxygen in the subsurface. The latter becomes critical where buildings are in close proximity or when increased building density is planned. Conservative assumptions enable simple, rapid and confident screening should sites and building designs comply to model assumptions. We do not model the aboveground “building” processes (e.g., air exchange), and assume the slab-on-ground seals the ground surface so that biodegradation of hydrocarbons is minimized under the built structure (i.e., the assessment remains conservative). Two graphs represent the entirety of the outcomes that allow simple screening of hydrocarbon vapors based only on the depth to the source of vapors below ground, the concentration of vapors within the source, the width of the slab-on-ground building, and the gap between buildings; all independent of soil type. Rectangular, square, and circular buildings are considered. Comparison with field sites and example applications are provided, along with a simple 8-step screening guide set in the context of existing guidance on PVI assessment.  相似文献   

3.
Aerobic biodegradation of vapor-phase petroleum hydrocarbons was evaluated in an intact soil core from the site of an aviation gasoline release. An unsaturated zone soil core was subjected to a flow of nitrogen gas, oxygen, water vapor, and vapor-phase hydrocarbons in a configuration analogous to a biofilter or an in situ bioventing or sparging situation. The vertical profiles of vapor-phase hydrocarbon concentration in the soil core were determined by gas chromatography of vapor samples. Biodegradation reduced low influent hydrocarbon concentrations by 45 to 92 percent over a 0.6-m interval of an intact soil core. The estimated total hydrocarbon concentration was reduced by 75 percent from 26 to 7 parts per million. Steady-state concentrations were input to a simple analytical model balancing advection and first-order biodegradation of hydrocarbons. First-order rate constants for the major hydrocarbon compounds were used to calibrate the model to the concentration profiles. Rate constants for the seven individual hydrocarbon compounds varied by a factor of 4. Compounds with lower molecular weights, fewer methyl groups, and no quaternary carbons tended to have higher rate constants. The first-order rate constants were consistent with kinetic parameters determined from both microcosm and tubing cluster studies at the field site.  相似文献   

4.
Aerobic biodegradation can contribute significantly to the attenuation of petroleum hydrocarbons vapors in the unsaturated zone; however, most regulatory guidance for assessing potential human health risks via vapor intrusion to indoor air either neglect biodegradation in developing generic screening levels or allow for only one order of magnitude additional attenuation for aerobically degradable compounds, which may be overly conservative in some cases. This paper describes results from three-dimensional numerical model simulations of vapor intrusion for petroleum hydrocarbons to assess the influence of aerobic biodegradation on the attenuation factor for a variety of source concentrations and depths for residential buildings with basements and slab-on-grade construction. The simulations conducted in this study provide a framework for understanding the degree to which bioattenuation will occur under a variety of scenarios and provide insight into site conditions that will result in significant biodegradation. This improved understanding may be used to improve the conceptual model of contaminant transport, guide field data collection and interpretation, and estimate semi-site-specific attenuation factors for combinations of source concentrations, source depth, oxygen distribution, and building characteristics where site conditions reasonably match the scenarios simulated herein.  相似文献   

5.
This study evaluates the theory, and some practical aspects of using temperature measurements to assess aerobic biodegradation in hydrocarbon contaminated soil. The method provides an easily applicable alternative for quantifying the rate of biodegradation and/or evaluating the performance of in situ remediation systems. The method involves two nonintrusive procedures for measuring vertical temperature profiles down existing monitoring wells; one using a thermistor on a cable for one‐time measurements and the other using compact temperature data loggers deployed for 3‐month to 1‐year period. These vertical temperature profile measurements are used to identify the depth and lateral extent of biodegradation as well as to monitor seasonal temperature changes throughout the year. The basic theory for using temperature measurements to estimate the minimum rate of biodegradation will be developed, and used to evaluate field measurements from sites in California where biodegradation of spilled petroleum hydrocarbons is due to natural processes. Following, temperature data will be used to evaluate the relative rates of biodegradation due to natural processes and soil vapor extraction (SVE) at a former refinery site in the North‐Central United States. The results from this study show that the temperature method can be a simple, cost effective tool for assessing biodegradation in the soil, and optimizing remediation systems at a wide variety of hydrocarbon spill sites.  相似文献   

6.
In this study, we present a petroleum vapor intrusion (PVI) tool implemented in Microsoft® Excel® using Visual Basic for Applications and integrated within a graphical interface. The latter helps users easily visualize two‐dimensional soil gas concentration profiles and indoor concentrations as a function of site‐specific conditions such as source strength and depth, biodegradation reaction rate constant, soil characteristics and building features. This tool is based on a two‐dimensional explicit analytical model that combines steady‐state diffusion‐dominated vapor transport in a homogeneous soil with a piecewise first‐order aerobic biodegradation model, in which rate is limited by oxygen availability. As recommended in the recently released United States Environmental Protection Agency's final PVI guidance, a sensitivity analysis and a simplified Monte Carlo uncertainty analysis are also included in the spreadsheet.  相似文献   

7.
Detailed site investigations to assess potential inhalation exposure and risk to human health associated with the migration of petroleum hydrocarbon vapors from the subsurface to indoor air are frequently undertaken at leaking underground storage tank (UST) sites, yet documented occurrences of petroleum vapor intrusion are extremely rare. Additional assessments are largely driven by low screening‐level concentrations derived from vapor transport modeling that does not consider biodegradation. To address this issue, screening criteria were developed from soil‐gas measurements at hundreds of petroleum UST sites spanning a range of environmental conditions, geographic regions, and a 16‐year time period (1995 to 2011). The data were evaluated to define vertical separation (screening) distances from the source, beyond which, the potential for vapor intrusion can be considered negligible. The screening distances were derived explicitly from benzene data using specified soil‐gas screening levels of 30, 50, and 100 µg/m3 and nonparametric Kaplan‐Meier statistics. Results indicate that more than 95% of benzene concentrations in soil gas are ≤30 µg/m3 at any distance above a dissolved‐phase hydrocarbon source. Dissolved‐phase petroleum hydrocarbon sources are therefore unlikely to pose a risk for vapor intrusion unless groundwater (including capillary fringe) comes in contact with a building foundation. For light nonaqueous‐phase liquid (LNAPL) hydrocarbon sources, more than 95% of benzene concentrations in soil gas are ≤30 µg/m3 for vertical screening distances of 13 ft (4 m) or greater. The screening distances derived from this analysis are markedly different from 30 to 100 ft (10 to 30 m) vertical distances commonly found cited in regulatory guidance, even with specific allowances to account for uncertainty in the hydrocarbon source depth or location. Consideration of these screening distances in vapor intrusion guidance would help eliminate unnecessary site characterization at petroleum UST sites and allow more effective and sustainable use of limited resources.  相似文献   

8.
Data requirements for assessing the significance of the soil vapor intrusion pathway are evolving, and the collection and interpretation of subslab and near-slab soil-gas samples are under discussion. The potential for different assessment paradigms for aerobically biodegradable and recalcitrant chemicals is also frequently debated. In this work, the soil-gas distribution beneath and around a slab-on-grade building overlying shallow (0.5 to >1.5 m below ground surface) petroleum hydrocarbon–impacted coarse alluvial soils was studied. The study spanned about 12 months, including the sampling of soil-gas hydrocarbon and oxygen concentrations, subslab soil vs. building pressure differentials and included weather conditions. Three-dimensional soil-gas concentration "snapshots" using samples from 79 soil-gas sampling points are presented here. Significant spatial variability was observed with hydrocarbon and oxygen concentrations ranging from about <0.01 to 200 mg/L and 0 to 21% v/v, respectively. The presence of oxygen and the depth to petroleum-impacted soils appeared to be the dominant factors in controlling the soil-gas distribution; the depletion of hydrocarbons over short lateral and vertical distances (<2 m) was observed in the well-oxygenated regions. Composition data suggest preferential biodegradation of lighter compounds at some points, as reflected in the ratio of the masses of chemicals eluting on the gas chromatography between methane and pentane (C1 and C5) and all others after pentane (>C5).  相似文献   

9.
Natural source zone depletion (NSZD) refers to processes within chemically impacted vadose and saturated zones that reduce the mass of contaminants remaining in a defined source control volume. Studies of large petroleum hydrocarbon release sites have shown that the depletion rate by vapor phase migration of degradation products from the source control volume through the vadose zone (V‐NSZD) is often considerably higher than the rate of depletion from the source control volume by groundwater flow carrying dissolved petroleum hydrocarbons arising from dissolution, desorption, or back diffusion, and degradation products arising from biodegradation (GW‐NSZD). In this study, we quantified vadose zone and GW‐NSZD at a small unpaved fuel release site in California typical of those in settings with predominantly low permeability media. We estimated vadose zone using a dense network of efflux monitoring locations at four sampling events over 2 years, and GW‐NSZD using groundwater monitoring data downgradient of the source control volume in three depth intervals spanning up to 9 years. On average, vadose zone was 17 times greater than GW‐NSZD during the time interval of comparison, and vadose zone was in the range of rates quantified at other sites with petroleum hydrocarbon releases. Estimating vadose zone and GW‐NSZD rates is challenging but the vadose zone rate is the best indicator of overall source mass depletion, whereas GW‐NSZD rates may be useful as baselines to quantify progress of natural or engineered remediation in portions of the saturated zone in which there are impediments to loss of methane and other gases to the vadose zone.  相似文献   

10.
Groundwater monitoring wells are present at most hydrocarbon release sites that are being assessed for cleanup. If screened across the vadose zone, these wells provide an opportunity to collect vapor samples that can be used in the evaluation of vapor movement and biodegradation processes occurring at such sites. This paper presents a low purge volume method (modified after that developed by the U.S. EPA) for sampling vapor from monitoring wells that is easy to implement and can provide an assessment of the soil gas total petroleum hydrocarbon (TPH) and O2 concentrations at the base of the vadose zone. As a result, the small purge method allows for sampling of vapor from monitoring wells to support petroleum vapor intrusion (PVI) risk assessment. The small purge volume method was field tested at the Hal's service station site in Green River, Utah. This site is well‐known for numerous soil gas measurements containing high O2 and high TPH vapor concentrations in the same samples which is inconsistent with well‐accepted biodegradation models for the vapor pathway. Using the low purge volume method, monitoring wells were sampled over, upgradient, and downgradient of the light nonaqueous phase liquid (LNAPL) footprint. Results from our testing at Hal's show that vapor from monitoring wells over LNAPL contained very low O2 and high TPH concentrations. In contrast, vapor from monitoring wells not over LNAPL contained high O2 and low TPH concentrations. The results of this study show that a low purge volume method is consistent with biodegradation models especially for sampling at sites where low permeability soils exist in and around a LNAPL source zone.  相似文献   

11.
It has been observed that the field biodegradation rates for soluble hydrocarbon plumes are significantly smaller than the aerobic rates observed in the laboratory. It is believed that this difference is related to the fact that in the field oxygen and hydrocarbon must be mixed before the biodegradation reaction can occur, and that the effective degradation rate is controlled by the actual, not mean, concentrations of oxygen and hydrocarbon. In this work, we present a conceptual model of oxygen-mixing limited biodegradation, which indicates that the effective degradation rate should depend on the cross correlation between the oxygen and hydrocarbon concentration fluctuations. This is followed by a development of a rigorous, field-scale model.  相似文献   

12.
It has been observed that the field biodegradation rates for soluble hydrocarbon plumes are significantly smaller than the aerobic rates observed in the laboratory. It is believed that this difference is related to the fact that in the field oxygen and hydrocarbon must be mixed before the biodegradation reaction can occur, and that the effective degradation rate is controlled by the actual, not mean, concentrations of oxygen and hydrocarbon. In this work, we present a conceptual model of oxygen-mixing limited biodegradation, which indicates that the effective degradation rate should depend on the cross correlation between the oxygen and hydrocarbon concentration fluctuations. This is followed by a development of a rigorous, field-scale model.  相似文献   

13.
The results of an API-sponsored pilot-scale subsurface venting system study are presented. The purpose of this study was to evaluate the effectiveness of forced venting techniques in controlling and removing hydrocarbon vapors from a subsurface formation. Both qualitative and quantitative sampling and analytical procedures were developed to measure hydrocarbon vapors extracted from the soil. Vapor recovery and equivalent liquid product recovery rates were measured at each test cell evacuation rate.
Two identical test cells were installed. Each cell contained 16 vapor monitoring probes spaced at distances from 4 to 44 feet from a vapor extraction (vacuum) well. Each cell was also configured with two air inlet wells to allow atmospheric air to enter the subsurface formation. The vapor monitoring probes were installed at three discrete elevations above the capillary zone. In situ vapor samples were obtained periodically from these probes to measure changes in vapor concentration and composition while extracting vapors from the vacuum well at three different flow rates (18.5 scfm, 22.5 scfm and 39.8 scfm). In situ vapor samples were analyzed using a portable gas chromatograph to quantify and speciate the vapors. Vacuum levels were also measured at each vapor sampling probe and at the vacuum well.
The soil venting techniques evaluated during this study offer an alternative approach for controlling and eliminating spilled or leaked hydrocarbons from sand or gravel formations of high porosity and moderate permeability. These techniques may also be used to augment conventional liquid recovery methods. The data collected during this study will be useful in optimizing subsurface venting systems for removing and controlling hydrocarbon vapors in soil. Study results indicate pulsed venting techniques may offer a cost-effective means of controlling or eliminating hydrocarbon vapors in soil.  相似文献   

14.
Soil gas samples from intact soil cores were collected on adsorbents at a field site, then thermally desorbed and analyzed by laboratory gas chromatography (GC). Vertical concentration profiles of predominant vapor phase petroleum hydrocarbons under ambient conditions were obtained for the zone directly above the capillary fringe. Water and residual phase weathered aviation gasoline were present in this region of the profile.
The sampling, trapping, and GC methodology was effective in most respects. Reproducibility, trapping, and desorption efficiency were generally satisfactory, and different sorbent tubes gave similar results. A minor shortcoming of the method occurred with the most volatile compound, 2,3-dimcthylbutane, which was poorly retained during several weeks of storage lime and was also poorly desorbed.
Vapor phase concentrations of predominant hydrocarbon compounds all increased with depth at one sampling location. At a more highly contaminated location, concentrations of highly volatile compounds increased with depth while concentrations of less volatile compounds remained constant or decreased, possibly indicating distillation effects. Scatier in the data was attributed to heterogeneities in water and residual phase distribution.  相似文献   

15.
Sulfate reducing conditions are widely observed in groundwater plumes associated with petroleum hydrocarbon releases. This leads to sulfate depletion in groundwater which can limit biodegradation of hydrocarbons (usually benzene, toluene, ethylbenzene, xylenes [BTEX] compounds) and can therefore result in extended timeframes to achieve groundwater cleanup objectives by monitored natural attenuation. Under these conditions, sulfate addition to the subsurface can potentially enhance BTEX biodegradation and facilitate enhanced natural attenuation. However, a delivery approach that enables effective contact with the hydrocarbons and is able to sustain elevated and uniform sulfate concentrations in groundwater remains a key challenge. In this case study, sulfate addition to a groundwater plume containing predominantly benzene by land application of agricultural gypsum and Epsom salt is described. Over 4 years of groundwater monitoring data from key wells subjected to pilot‐scale and site‐wide land application events are presented. These are compared to data from pilot testing employing liquid Epsom salt injections as an alternate sulfate delivery approach. Sulfate land application, sulfate retention within the vadose zone, and periodic infiltration following ongoing precipitation events resulted in elevated sulfate concentrations (>150 mg/L) in groundwater that were sustained over 12 months between application events and stimulated benzene biodegradation as indicated by declines in dissolved benzene concentration, and compound‐specific isotope analysis data for carbon in benzene. Long‐term groundwater benzene concentration reductions were achieved in spite of periodic rebounds resulting from water table fluctuations across the smear zone. Land application of gypsum is a potentially cost‐effective sulfate delivery approach at sites with open, unpaved surfaces, relatively permeable geology, and shallow hydrocarbon impacts. However, more research is needed to understand the fate and persistence of sulfate and to improve the likelihood of success and effectiveness of this delivery approach.  相似文献   

16.
The fate of hydrocarbons in the subsurface near Bemidji, Minnesota, has been investigated by a multidisciplinary group of scientists for over a quarter century. Research at Bemidji has involved extensive investigations of multiphase flow and transport, volatilization, dissolution, geochemical interactions, microbial populations, and biodegradation with the goal of providing an improved understanding of the natural processes limiting the extent of hydrocarbon contamination. A considerable volume of oil remains in the subsurface today despite 30 years of natural attenuation and 5 years of pump‐and‐skim remediation. Studies at Bemidji were among the first to document the importance of anaerobic biodegradation processes for hydrocarbon removal and remediation by natural attenuation. Spatial variability of hydraulic properties was observed to influence subsurface oil and water flow, vapor diffusion, and the progression of biodegradation. Pore‐scale capillary pressure‐saturation hysteresis and the presence of fine‐grained sediments impeded oil flow, causing entrapment and relatively large residual oil saturations. Hydrocarbon attenuation and plume extent was a function of groundwater flow, compound‐specific volatilization, dissolution and biodegradation rates, and availability of electron acceptors. Simulation of hydrocarbon fate and transport affirmed concepts developed from field observations, and provided estimates of field‐scale reaction rates and hydrocarbon mass balance. Long‐term field studies at Bemidji have illustrated that the fate of hydrocarbons evolves with time, and a snap‐shot study of a hydrocarbon plume may not provide information that is of relevance to the long‐term behavior of the plume during natural attenuation.  相似文献   

17.
Intrinsic bioremediation of a petroleum-impacted wetland   总被引:4,自引:0,他引:4  
Following the 1994 San Jacinto River flood and oil spill in southeast Texas, a petroleum-contaminated wetland was reserved for a long-term research program to evaluate bioremediation as a viable spill response tool. The first phase of this program, presented in this paper, evaluated the intrinsic biodegradation of petroleum in the contaminated wetland. Sediment samples from six test plots were collected 11 times over an 11-month period to assess the temporal and spatial petroleum concentrations. Petroleum concentrations were evaluated using gas chromatography-mass spectrometer analyses of specific target compounds normalized to the conservative biological marker, C(30)17alpha,21beta(H)-hopane. The analyses of specific target compounds were able to characterize that significant petroleum biodegradation had occurred at the site over the one-year period. Total resolved saturate and total resolved aromatic hydrocarbon data indicated the petroleum was degraded more than 95%. In addition, first-order biodegradation rate constants were calculated for the hopane-normalized target compounds and supported expected biodegradation patterns. The rapid degradation rates of the petroleum hydrocarbons are attributed to conditions favorable to biodegradation. Elevated nutrient levels from the flood deposition and the unconsolidated nature of the freshly deposited sediment possibly provided a nutrient rich, oxic environment. Additionally, it is suggested that an active and capable microbial community was present due to prior exposure to petroleum. These factors provided an environment conducive for the rapid bioremediation of the petroleum in the contaminated wetland.  相似文献   

18.
Groundwater remediation and no-further action decision making at petroleum underground storage tank (UST) sites has largely been based on an understanding of plume length, plume stability, and attenuation rates for key hydrocarbon constituents. Regulatory guidance to support and guide such decisions is based in part on plume studies involving individual hydrocarbon constituents, namely benzene and methyl tert-butyl ether (MTBE). Questions remain regarding whether current guidance is applicable to chemical mixtures such as gasoline range organics (GRO), diesel range organics (DRO), and oxygen containing organic compounds (OCOCs) resulting from hydrocarbon biodegradation. To help address this concern, data from California's GeoTracker database were used to estimate maximum plume lengths, plume stability, and attenuation rates of DRO (which can be used as an analytical surrogate for OCOCs) and GRO relative to benzene and MTBE. The distributions of maximum plume lengths were similar for the four constituents with medians ranging from 27 to 32 m. The fraction of monitoring wells with a decreasing concentration trend ranged from 19% for DRO to 40% for MTBE, while fewer than 7% of the wells had an increasing concentration trend for any of the constituents. Median attenuation rates ranged from 0.10% day−1 for DRO to 0.17% day−1 for MTBE. The results suggest attenuation based risk management is appropriate for DRO and GRO plumes at most petroleum UST sites.  相似文献   

19.
Transport and Biological Fate of Toluene in Low-Permeability Soils   总被引:1,自引:0,他引:1  
The effect of simultaneous sorption, diffusion, and biodegradation on the fate and transport of toluene in low-permeability soil formations was examined. A transport model accounting for vapor and liquid sorption, vapor diffusions, and first-order biodegradation was developed to describe the movement of volatile solute in unsaturated soils. Modeling studies were followed with laboratory batch and column studies on fine-grained soil samples obtained from a gasoline-contaminated site. Batch experiments yielded the sorption and diffusion coefficients for generating theoretical solute transport profiles. Column studies were conducted to examine toluene sorption, diffusion, and biodegradation under aerobic and denitrifying conditions. Results from the column studies indicated that vapor sorption onto the soil was minimal due to the high moisture content of the soil. Comparison of model predictions with experimental results indicated that the SASK model, which is based on the resistivity theory, provided a more accurate prediction of the vapor phase tortuosity than the frequently used Millington-Quirk equation. Laboratory results of toluene concentration profiles matched well with the model predictions and yielded degradation rates comparable to those obtained in the field. Column studies, examining toluene biodegradation under aerobic and denitrifying conditions in low-permeability soils, indicated that the presence of excess nitrate in aerobic environments yielded higher solute degradation rates than those observed under exclusively aerobic systems.  相似文献   

20.
This paper presents model simulation results of vapor intrusion into structures built atop sites contaminated with volatile or semivolatile chemicals of concern. A three-dimensional finite element model was used to investigate the importance of factors that could influence vapor intrusion when the site is characterized by nonhomogeneous soils. Model simulations were performed to examine how soil layers of differing properties alter soil-gas concentration profiles and vapor intrusion rates into structures. The results illustrate difference in soil-gas concentration profiles and vapor intrusion rates between homogeneous and layered soils. The findings support the need for site conceptual models to adequately represent a site's geology when conducting site characterizations, interpreting field data, and assessing the risk of vapor intrusion at a given site. For instance, in layered geologies, a lower permeability and diffusivity soil layer between the source and building often limits vapor intrusion rates, even if a higher permeability layer near the foundation permits increased soil-gas flow rates into the building. In addition, the presence of water-saturated clay layers can considerably influence soil-gas concentration profiles. Therefore, interpreting field data without accounting for clay layers in the site conceptual model could result in inaccurate risk calculations. Important considerations for developing more accurate conceptual site models are discussed in light of the findings.  相似文献   