首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The mercury content of 116 reference materials (RMs) from ten international organisations was determined in this study, which focused on variability within and between batches of RMs. Direct mercury analysis (DMA) was applied to RMs having Hg contents between 1 and 6300 ng g?1 and provided good precision and accuracy. Accuracy was demonstrated by the agreement of our results with certified values, while replicates were made to establish the precision. Low within‐batch variability was noted, with precision from 0.1 to 23% (n = 3–5) apparently depending on Hg content and homogeneity, whereas systematic offsets were detected among several batches. Thanks to the analysis of different batches; the homogeneity or heterogeneity of several RMs was shown, and thus, suitable RMs for quality control for Hg determinations could be recommended.  相似文献   

2.
The aim of this study was to improve the quality of laser ablation inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) determination of phosphorus in crystalline quartz. Over the last decade, the Geological Survey of Norway has routinely performed trace element determinations on quartz from both operating and potential quartz deposits by LA‐ICP‐MS. The determined phosphorus concentrations were, with but few exceptions, consistently within the range of 10 to 30 μg g?1, results that seemed to be both too high and too consistent. The multi‐material calibration curve obtained from a suite of reference materials (NIST SRM 610, 612, 614, 1830, BAM No. 1 amorphous SiO2 glass) did not define a precise regression line. Published phosphorus concentrations for the reference materials are poorly constrained and the observed dispersions along the multi‐material calibration curve suggest that some of the reference values may be inaccurate. Furthermore, the calibration curve did not pass through the origin of the [(cps 31P/cps 30Si) · cone. Si] vs. P concentration diagram; thus, in addition to the uncertainties of the literature values of phosphorus, it is difficult to define the calibration curve. Three reference materials (NIST SRM 614, 1830, synthetic quartz KORTH) were sent for phosphorus accelerator implantation, providing an independent and accurate (± 3%) approach for determining phosphorus concentrations in crystalline quartz. The intrinsic phosphorus concentrations of the three implanted samples plus those for NIST SRM 610 and 612 were determined by secondary ion mass spectrometry (SIMS), yielding new phosphorus values for NIST SRM 610, 612, 614 and 1830. Using these new values resulted in a better defined LA‐ICP‐MS calibration curve. However, the source of the ICP‐MS related background could not be defined, such that it must still be empirically corrected for.  相似文献   

3.
原子荧光光谱法测定土壤和水系沉积物国家标准物质中砷   总被引:3,自引:1,他引:3  
郭敬华  马辉  王水锋 《岩矿测试》2009,28(2):182-184
用王水浸提法和硝酸-高氯酸-氢氟酸混合酸消解法处理样品,原子荧光光度光谱法测定土壤和水系沉积物国家标准物质样品中的砷。方法检出限为0.02 mg/kg。两种前处理方法砷的测定值与标准值相符,均可以满足土壤和水系沉积物样品中砷含量的测定要求。单纯测定样品中砷含量时,王水浸提法更好;如果在测定砷同时还要测定其他元素,则可以选用混合酸消解法。  相似文献   

4.
The natural river water certified reference material SLRS‐5 (NRC‐CNRC) was routinely analysed in this study for major and trace elements by ten French laboratories. Most of the measurements were made using ICP‐MS. Because no certified values are assigned by NRC‐CNRC for silicon and 35 trace element concentrations (rare earth elements, Ag, B, Bi, Cs, Ga, Ge, Li, Nb, P, Rb, Rh, Re, S, Sc, Sn, Th, Ti, Tl, W, Y and Zr), or for isotopic ratios, we provide a compilation of the concentrations and related uncertainties obtained by the participating laboratories. Strontium isotopic ratios are also given.  相似文献   

5.
We report high‐precision iron isotopic data for twenty‐two commercially available geological reference materials, including silicates, carbonatite, shale, carbonate and clay. Accuracy was checked by analyses of synthetic solutions with known Fe isotopic compositions but different matrices ranging from felsic to ultramafic igneous rocks, high Ca and low Fe limestone, to samples enriched in transition group elements (e.g., Cu, Co and Ni). Analyses over a 2‐year period of these synthetic samples and pure Fe solutions that were processed through the whole chemistry procedure yielded an average δ56Fe value of ?0.001 ± 0.025‰ (2s, n = 74), identical to the expected true value of 0. This demonstrates a long‐term reproducibility and accuracy of < 0.03‰ for determination of 56Fe/54Fe ratios. Reproducibility and accuracy were further confirmed by replicate measurements of the twenty‐two RMs, which yielded results that perfectly match the mean values of published data within quoted uncertainties. New recommended values and associated uncertainties are presented for interlaboratory calibration in the future.  相似文献   

6.
We report on an improved method for determining trace element abundances in seawater and other natural waters. The analytical procedure involves co‐precipitation on iron hydroxides after addition of a Tm spike, and measurement by inductively coupled plasma‐sector field mass spectrometry (ICP‐SFMS). The validity of the method was assessed through a series of co‐precipitation experiments, using ultra‐diluted solutions of a certified rock reference material (BIR‐1). Results obtained for four natural water reference materials (NASS‐5, CASS‐4, SLEW‐3, SLRS‐4) are in agreement with published working values for rare earth elements, yttrium, vanadium and, when available, for hafnium, zirconium, thorium and scandium. A set of proposed values with uncertainties typically better than 8% RSD is proposed for Hf, Zr and Th.  相似文献   

7.
Isotope dilution (ID) mass spectrometry is a primary method of analysis suited for the accurate and precise measurement of several trace elements in geological matrices. Here we present mass fractions and respective uncertainties for Cr, Cu, Ni, Sn, Sr and Zn in 10 silicate rock reference materials (BCR‐2, BRP‐1, BIR‐1, OU‐6, GSP‐2, GSR‐1, AGV‐1, RGM‐1, RGM‐2 and G‐3) obtained by the double ID technique and measuring the isotope ratios with an inductively coupled plasma‐mass spectrometer equipped with collision cell. Test portions of the samples were dissolved by validated procedures, and no further matrix separation was applied. Addition of spikes was designed to achieve isotope ratios close to unity to minimise error magnification factors, according to the ID theory. Radiogenic ingrowth of 87Sr from the decay of 87Rb was considered in the calculation of Sr mass fractions. The mean values of our results mostly agree with reference values, considering both uncertainties at the 95% confidence level, and also with ID data published for AGV‐1. Considering all results, the means of the combined uncertainties were < 1% for Sr, approximately 2% for Sn and Cu, 4% for Cr and Ni and almost 6% for Zn.  相似文献   

8.
This article presents new boron concentrations for nine geochemical reference materials (GS‐N, FK‐N, GL‐O, BX‐N, DT‐N, AN‐G, GH, Mica‐Fe, Mica‐Mg). After extraction by a modified pyrohydrolysis technique, boron concentrations were measured by ICP‐MS. The blank levels for the whole procedure were 0.091 ± 0.020 ng ml?1 or 14 ± 5 ng of boron in total. The method was first validated by measuring nine reference materials with known boron concentrations. The determined boron concentrations are all within the range of recommended or published values, which means that the yields were 100%, and show precisions below 10% for samples containing over 2 μg g?1 of boron.  相似文献   

9.
Magnesium isotopic compositions are reported for twenty‐four international geological reference materials including igneous, metamorphic and sedimentary rocks, as well as phlogopite and serpentine minerals. The long‐term reproducibility of Mg isotopic determination, based on 4‐year analyses of olivine and seawater samples, was ≤ 0.07‰ (2s) for δ26Mg and ≤ 0.05‰ (2s) for δ25Mg. Accuracy was tested by analysis of synthetic reference materials down to the quoted long‐term reproducibility. This comprehensive dataset, plus seawater data produced in the same laboratory, serves as a reference for quality assurance and inter‐laboratory comparison of high‐precision Mg isotopic data.  相似文献   

10.
This report describes the location, collection, preparation, homogeneity testing, analysis, data-processing and assignment of certified values of a polymetallic nodule (GSPN-1) and marine sediment (GSMS-1). Materials used in the preparation of these reference materials were collected in 1986 and 1987 from the central Pacific Ocean, by the Chinese Ministry of Geology and Mineral Resources (MGMR). A total of fifty one recommended element concentrations and five proposed concentrations are reported for GSPN-1. For GSMS-1, a total of fifty recommended and seven proposed values are presented.  相似文献   

11.
We present a revised alkali fusion method for the determination of trace elements in geological samples. Our procedure is based on simple acid digestion of powdered low‐dilution (flux : sample ≈ 2 : 1) glass beads where large sample dilution demanded by high total dissolved solids, a main drawback of conventional alkali fusion, could be circumvented. Three geological reference materials (G‐3 granite, GSP‐2 granodiorite and SGD‐1a gabbro) decomposed by this technique and routine tabletop acid digestion were analysed for thirty trace elements using a quadrupole ICP‐MS. Results by conventional acid digestion distinctly showed poor recoveries of Zr, Hf and rare earth elements due to incomplete dissolution of resistant minerals. On the other hand, results obtained by our method were in reasonable agreement with reference data for most analytes, indicating that refractory minerals were efficiently dissolved and volatile loss was insignificant.  相似文献   

12.
This study describes two methods (Procedures‐1 and ‐2) for the direct extraction of Au by an inorganic acid mixture (HClO4‐HBr‐HI‐aqua regia) from complex sample matrices. Standard PTFE jars at 200 °C were used to decompose test portions of 0.5–1 g, with subsequent precise and accurate analysis by ICP‐MS without any other preconcentration or separation. Procedure‐1 decomposed samples effectively without the necessity of leaching with HF and was developed for dust samples from e‐waste (electronic waste) processing; however, testing on geological reference materials showed very good results. The analyses of replicate decompositions (= 5) from both procedures yielded very good precision (< 5% RSD) for most of the reference materials. The accuracy achieved was better than ± 10%, with the exception of NIST SRM 2782 data from Procedure‐1. Two unknown samples of dust from e‐waste processing (P‐1 and VM‐1) exhibited elevated concentrations of Au (21.31–61.64 μg g?1) with precision better than 10% (= 5). The proposed techniques are simple, sensitive and sparing in the use of chemicals, and are designed for a variety of e‐waste dust samples. No significant influences were observed for the predicted spectral interferences on mass 197Au.  相似文献   

13.
Here we describe high‐precision molybdenum isotopic composition measurements of geological reference materials, performed using multi‐collector inductively coupled plasma‐mass spectrometry (MC‐ICP‐MS). Purification of Mo for isotopic measurements was achieved by ion exchange chromatography using Bio‐Rad AG® 1‐X8 anion exchange resin. Instrumental mass bias was corrected using 100Mo‐97Mo double spiking techniques. The precision under intermediate measurement conditions (eighteen measurement sessions over 20 months) in terms of δ98/95Mo was 0.10‰ (2s). The measurement output was approximately four times more efficient than previous techniques, with no compromise in precision. The Mo isotopic compositions of seven geochemical reference materials, seawater (IAPSO), manganese nodules (NOD‐P‐1 and NOD‐A‐1), copper‐molybdenum ore (HV‐2), basalt (BCR‐2) and shale (SGR‐1b and SCo‐1), were measured. δ98/95Mo values were obtained for IAPSO (2.25 ± 0.09‰), NOD‐P‐1 (?0.66 ± 0.05‰), NOD‐A‐1 (?0.48 ± 0.05‰), HV‐2 (?0.23 ± 0.10‰), BCR‐2 (0.21 ± 0.07‰), SCo‐1 (?0.24 ± 0.06‰) and SGR‐1b (0.63 ± 0.02‰) by calculating δ98/95Mo relative to NIST SRM 3134 (0.25‰, 2s). The molybdenum isotopic compositions of IAPSO, NOD‐A‐1 and NOD‐P‐1 obtained in this study are within error of the compositions reported previously. Molybdenum isotopic compositions for BCR‐2, SCo‐1 and SGR‐1b are reported for the first time.  相似文献   

14.
Iron Isotopic Compositions of Geological Reference Materials and Chondrites   总被引:2,自引:0,他引:2  
High‐precision iron isotopic compositions for Fe‐bearing geological reference materials and chondrites with a wide range of matrices (e.g., silicates, oxides, organic‐bearing materials) are reported. This comprehensive data set should serve as a reference for iron isotopic studies across a range of geological and biological disciplines for both quality assurance and inter‐laboratory calibration. Where comparison is available, the iron isotopic compositions of most geological reference materials measured in this study were in agreement with previously published data within quoted uncertainties. Recommendations for the reporting of future iron isotopic data and associated uncertainties are also presented. Long‐term repeat analyses of all samples indicate that highly reproducible iron isotopic measurements are now obtainable (± 0.03‰ and ± 0.05‰ for δ56Fe and δ57Fe, respectively).  相似文献   

15.
In this study, a technique for high precision in situ Fe and Mg isotope determinations by femtosecond‐laser ablation‐multi collector‐ICP‐MS (fs‐LA‐MC‐ICP‐MS) was developed. This technique was employed to determine reference values for a series of common reference glasses that may be used for external standardisation of in situ Fe and Mg isotope determinations in silicates. The analysed glasses are part of the MPI‐DING and United States Geological Survey (USGS) reference glass series, consisting of basaltic (BIR‐1G, BCR‐2G, BHVO‐2G, KL2‐G, ML3B‐G) and komatiitic (GOR128‐G and GOR132‐G) compositions. Their Fe and Mg isotope compositions were determined by in situ fs‐LA‐MC‐ICP‐MS and by conventional solution nebulisation multi‐collector ICP‐MS. We determined δ56Fe values for these glasses ranging between ‐0.04‰ and 0.10‰ (relative to IRMM‐014) and δ26Mg values ranging between ‐0.40‰ and ‐0.15‰ (relative to DSM‐3). Our fs‐LA‐MC‐ICP‐MS results for both Fe and Mg isotope compositions agreed with solution nebulisation analyses within analytical uncertainties. Furthermore, the results of three USGS reference glasses (BIR‐1G, BHVO‐2G and BCR‐2G) agreed with previous results for powdered and dissolved aliquots of the same reference materials. Measurement reproducibilities of the in situ determinations of δ56Fe and δ26Mg values were usually better than 0.12‰ and 0.13‰ (2s), respectively. We further demonstrate that our technique is a suitable tool to resolve isotopic zoning in chemically‐zoned olivine crystals. It may be used for a variety of different applications on isotopically‐zoned minerals, e.g., in magmatic or metamorphic rocks or meteorites, to unravel their formation or cooling rates.  相似文献   

16.
Speciation of Cr in geochemical reference materials was characterised by sequential extraction and X‐ray absorption near‐edge structure (XANES) spectroscopy to identify Cr(III) resulting from the reduction of pollutant Cr(VI). Sequential extraction suggested that the amount of Cr associated with an acetic acid soluble fraction was low; Cr associated with a reducible phase and an oxidisable phase was extracted at 5–10% of the total Cr concentration, and the residual phase was found to be the dominant Cr‐containing fraction. Cr speciation in soil artificially doped with Cr(VI) and sediment samples collected from highly populated and industrialised areas was different from that in naturally occurring materials. Substantial Cr was extracted as a reducible phase (15–30%) and an oxidisable phase (30–60%) for these samples. Through subsequent XANES spectroscopy analysis, the reducible phase was explained by Cr bound to Fe hydroxide, while the oxidisable phase was a mixture of Cr bound to humic substances and Cr hydroxides. That is, Cr(VI) present as a contaminant in sediments and soils was reduced to Cr(III), which then bound to Fe hydroxide and humic substances, precipitating as a hydroxide. Thus, a combination of sequential extraction and XANES spectroscopy allows for effective identification and quantification of the chemical forms of Cr in sediments and soils.  相似文献   

17.
The fifth version of natural river water certified reference material, SLRS‐5 (National Research Council – Conseil National de Recherches Canada), is commonly used to control the quality of major and trace element measurements. Concentrations of silicon and thirty‐one uncertified trace elements have been reported for the certified reference material SLRS‐4, but they are not yet available for SLRS‐5. Here, SLRS‐5/SLRS‐4 ratios were deduced from SLRS‐5 and SLRS‐4 measurements by inductively coupled plasma‐atomic emission spectrometry and high‐resolution inductively coupled plasma‐mass spectrometry for certified elements and thirty‐five uncertified elements (rare earth elements, B, Bi, Br, Cs, Ga, Ge, Hf, Li, Nb, P, Pd, Rb, Rh, S, Sc, Si, Sn, Th, Ti, Tl, Y). Both reference materials were measured directly one after the other, so that calculated elemental ratios would not be notably influenced either by calibration uncertainties or by eventual long‐term instrumental drift. The computed ratios are in good agreement with those deduced from the certified values. We also report concentrations for thirty‐three uncertified elements in SLRS‐5 by combining the measured SLRS‐5/SLRS‐4 ratios and the published SLRS‐4 values. The resulting new data set provides target SLRS‐5 values, which will be useful in quality control procedures.  相似文献   

18.
A HF‐free sample preparation method was used to purify silicon in twelve geological RMs. Silicon isotope compositions were determined using a Neptune instrument multi‐collector‐ICP‐MS in high‐resolution mode, which allowed separation of the silicon isotope plateaus from their interferences. A 1 μg g‐1 Mg spike was added to each sample and standard solution for online mass bias drift correction. δ30Si and δ29Si values are expressed in per mil (‰), relative to the NIST SRM 8546 (NBS‐28) international isotopic RM. The total variation of δ30Si in the geological reference samples analysed in this study ranged from ‐0.13‰ to ‐0.29‰. Comparison with δ29Si values shows that these isotopic fractionations were mass dependent. IRMM‐17 yielded a δ30Si value of ‐1.41 ± 0.07‰ (2s, n = 12) in agreement with previous data. The long‐term reproducibility for natural samples obtained on BHVO‐2 yielded δ30Si = ‐0.27 ± 0.08‰ (2s, n = 42) on a 12 month time scale. An in‐house Si reference sample was produced to check for the long‐term reproducibility of a mono‐elemental sample solution; this yielded a comparable uncertainty of ± 0.07‰ (2s, n = 24) over 5 months.  相似文献   

19.
High spatial resolution multiple sulfur isotope studies undertaken by multi‐collector secondary ion mass spectrometry (SIMS) commonly use well‐characterised sulfide reference materials that do not (or are assumed not to) exhibit mass‐independent fractionation in 33S and 36S, taking advantage of the three‐isotope plot to evaluate the extent of such fractionation in unknown targets. As a result, few studies to date have used a mass independently fractionated reference sulfide to demonstrate accuracy of measurement and/or data reduction procedures. This article evaluates two mass independently fractionated sulfides, a pyrite from the 3.7 Ga Isua greenstone belt and a pyrrhotite from a 2.7 Ga gold deposit in Minas Gerais, Brazil, which may be used to provide additional confidence in the obtained multiple sulfur isotope data. Additionally, the article presents a method for measuring quadruple sulfur isotopes by SIMS at a comparable spatial and volume resolution to that typically employed for triple sulfur isotopes. This method has been applied to the Isua pyrite as well as to a sample of 2.5 Ga pyrite from the Campbellrand, Transvaal, South Africa, previously investigated using SIMS for triple sulfur isotopes, illustrating its potential for quadruple sulfur investigations.  相似文献   

20.
The double‐spike method with multi‐collector inductively coupled plasma‐mass spectrometry was used to measure the Mo mass fractions and isotopic compositions of a set of geological reference materials including the mineral molybdenite, seawater, coral, as well as igneous and sedimentary rocks. The long‐term reproducibility of the Mo isotopic measurements, based on two‐year analyses of NIST SRM 3134 reference solutions and seawater samples, was ≤ 0.07‰ (two standard deviations, 2s, n = 167) for δ98/95Mo. Accuracy was evaluated by analyses of Atlantic seawater, which yielded a mean δ98/95Mo of 2.03 ± 0.06‰ (2s, n = 30, relative to NIST SRM 3134 = 0‰) and mass fraction of 0.0104 ± 0.0006 μg g?1 (2s, n = 30), which is indistinguishable from seawater samples taken world‐wide and measured in other laboratories. The comprehensive data set presented in this study serves as a reference for quality assurance and interlaboratory comparison of high‐precision Mo mass fractions and isotopic compositions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号