首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
The buried-valley aquifers that are common in the glacial deposits of the northern hemisphere are a typical case of the strip aquifers that occur in many parts of the world. Pumping from a narrow strip aquifer leads to much greater drawdown and much more distant drawdown effects then would occur in a sheet aquifer with a similar transmissivity and storage coefficient. Widely used theories for radial flow to wells, such as the Theis equation, are not appropriate for narrow strip aquifers. Previously published theory for flow to wells in semiconfined strip aquifers is reviewed and a practical format of the type curves for pumping-test analysis is described. The drawdown response of strip aquifers to pumping tests is distinctive, especially for observation wells near the pumped well. A case study is presented, based on extensive pumping test experience for the Estevan Valley Aquifer in southern Saskatchewan, Canada. Evaluation of groundwater resources in such buried-valley aquifers needs to take into account the unusually large drawdowns in response to pumping.  相似文献   

2.
This paper derives an equivalent of Darcian Theis solution for non-Darcian flow induced by constant rate pumping of a well in a confined aquifer. The derivation, which is valid at later times only, is original. It utilizes Izbash's equation. This introduces an additional parameter to Darcian condition, namely, empirical exponent. The solution is a non-Drcian equivalent of Jacob straight line method for analyzing pumping tests at late times. It can be used to determine aquifer parameters: storativity, analogous hydraulic conductivity, and empirical exponent. However, while the Jacob method requires a minimum of only one pumping test with one observation well, the additional parameter in the present solution means that a minimum of two observation wells in one test or two pumping tests at different rates with one observation well are required. The derived solution is applied to a case study at Plomeur in Brittany, France, and is shown to provide a practical and efficient method for analyzing pumping tests where non-Darcian groundwater flow occurs.  相似文献   

3.
In this study, we attempted to analyse a drawdown pattern around a pumping well in an unconfined sandy gravelly aquifer constructed in a laboratory tank by means of both experimental and numerical modelling of groundwater flow. The physical model consisted of recharge, aquifer and discharge zones. Permeability and specific yield of the aquifer material were determined by Dupuit approximation under steady‐state flow and stepwise gravitational drainage of groundwater, respectively. The drawdown of water table in pumping and neighbouring observation wells was monitored to investigate the effect of no‐flow boundary on the drawdown pattern during pumping for three different boundary conditions: (i) no recharge and no discharge with four no‐flow boundaries (Case 1); (ii) no recharge and reservoir with three no‐flow boundaries (Case 2); (iii) recharge and discharge with two no‐flow boundaries (Case 3). Based on the aquifer parameters, numerical modelling was also performed to compare the simulated drawdown with that observed. Results showed that a large difference existed between the simulated drawdown and that observed in wells for all cases. The reason for the difference could be explained by the formation of a curvilinear type water table between wells rather than a linear one due to a delayed response of water table in the capillary fringe. This phenomenon was also investigated from a mass balance study on the pumping volume. The curvilinear type of water table was further evidenced by measurement of water contents at several positions in the aquifer between wells using time domain reflectometry (TDR). This indicates that the existing groundwater flow model applicable to an unconfined aquifer lacks the capacity to describe a slow response of water table in the aquifer and care should be taken in the interpretation of water table formation in the aquifer during pumping. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

4.
We have derived an analytical solution for two-region flow toward a well in a confined aquifer based on a linearization method. The two-region flow includes Izbash non-Darcian flow near the well and Darcian flow in the rest of the aquifer. The wellbore storage is also considered. The type curves in the non-Darcian and Darcian flow domains are obtained by a numerical Laplace inversion method incorporated in MATLAB programs. We have compared our results with the one-region Darcian flow model (Theis). Our solutions agree with those of Sen [Sen Z. Type curves for two-region well flow. J Hydr Eng 1988;114(12):1461–84] which were obtained using the Boltzmann transform at late times for fully turbulent flow, while some difference has been found at early and moderate times. We have defined a dimensionless non-Darcian hydraulic conductivity term which is shown to be a key parameter for analyzing the two-region flow. A smaller dimensionless non-Darcian hydraulic conductivity results in a larger drawdown in the non-Darcian flow region at late times. However, the dimensionless non-Darcian hydraulic conductivity does not affect the slope of the dimensionless drawdown versus the logarithmic dimensionless time in the non-Darcian flow region at late times. The dimensionless non-Darcian hydraulic conductivity does not affect the late time drawdown in the Darcian flow region.  相似文献   

5.
The vertical variation of drawdown around pumping wells generates an induced flow in the observation wells. A set of governing equations is presented to couple the drawdown variation and the vertical flux distribution in observation wells. A numerical example is performed to justify the governing equations and to verify the solution methods used by the simulation software WT. The example analyzes the effect of skin loss, wellbore storage, and vertical segmentation on the drawdown and induced flow in observation well during pumping. The evaluation of the Fairborn pumping test involves a vertically homogeneous and anisotropic water table aquifer, uniform well‐face drawdown conditions in the pumping well and simulation of the drawdown evolution in the observation well with and without the effect of induced flow. The computer calibrations resulted in small differences between the measured and simulated drawdown curves.  相似文献   

6.
Following Hemker and Maas (1987) the models of two or three leaky aquifers are applied to simulate the flow to vertical wells operating in the fractured or dual porosity aquifers. The software WellTest (WT) (Székely 2015) is used for calculating the drawdown and discharge rate variation. The comparative analysis with the independent analytical solutions by Boulton and Streltsova-Adams (1978), Warren and Root (1963), Kazemi et al. (1969) concluded with acceptable agreement between the WT simulation and the alternate calculation methods. The selected field tests have been conducted in fractured limestone aquifers. The pumping test west of Copenhagen shows an example of fractured aquifer with considerable negative skin effect at the well face. The flowing well Wafra W1 in Kuwait operates in the two-zone aquifer exhibiting sufficient vertical recharge via leakage beyond a circular domain of estimated radius of 2460 m.  相似文献   

7.
In order to understand the flow pattern around a pumping well partially penetrating a vertically extensive aquifer, a specially designed pumping test was carried out in Pakistan. In this paper salient features of the test have been described. The spatial distributions of drawdown have been shown graphically. Some of the preliminary conclusions made from the drawdown pattern include:
  • • The distance beyond which the flow is likely to be horizontal increases with decrease in the degree of aquifer penetration.
  • • In equidistant observation wells open at different depths, (1) the drawdowns tend to merge at larger times, provided the observation point is located within the screened section of the aquifer; (2) the less the depth of penetration is, the earlier the drawdowns start merging; and (3) the initial rate of drawdown near the aquifer top is slow but catches up with time to exceed those at deeper points.
  相似文献   

8.
In this study, we use a linearization procedure and a finite difference method to solve non-Darcian flow to a well in an aquifer–aquitard system. The leakage effect is considered. Flow in the aquifer is assumed to be non-Darcian and horizontal, whereas flow in the aquitard is assumed to be Darcian and vertical. The Izbash equation [Izbash SV. O filtracii V Kropnozernstom Materiale. USSR: Leningrad; 1931 [in Russian]] is employed to describe the non-Darcian flow. The wellbore storage is also considered in this study. An approximate semi-analytical solution has been obtained by the linearization procedure, and a numerical solution has been obtained by using a finite difference method. The previous solutions for Darcian flow case and non-Darcian flow case without leakage can be described as special cases of the new solutions. The error caused by the linearization procedure has also been analyzed. The relative error caused by the linearization procedure is nearly 100% at early times, and decreases to zero at late times. We have also compared the results in this study with Wen et al. [Wen Z, Huang G, Zhan H. A numerical solution for non-Darcian flow to a well in a confined aquifer using the power law function. J Hydrol, 2008d [in revision]] in which the leakage effect is not considered, and Hantush and Jacob [Hantush MS, Jacob CE. Non-steady radial flow in an infinite leaky aquifer. Trans Am Geophys Union 1955;36(1):95–100] who investigated a similar problem in Darcian flow case. The comparison of this study and Wen et al. (2008d) indicates the dimensionless drawdown in the aquifer with leakage is less than that without leakage, and the leakage has little effect at early times. The comparison between the results of this study and that of Hantush and Jacob (1955) indicates that the dimensionless drawdown in the aquifer for non-Darcian flow is larger at early times and smaller at late times, than their counterparts for Darcian flow. A larger dimensionless non-Darcian conductivity kD results in a smaller dimensionless drawdown in the aquifer at late times, and leads to a larger dimensionless drawdown in the aquifer at early times. A smaller dimensionless leakage parameter BD results in a smaller drawdown at late times, and the leakage does not affect the early-time drawdown. The analysis of the dimensionless drawdown inside the well has also been included in this study when the wellbore storage is considered.  相似文献   

9.
Faults can act as flow barriers or conduits to groundwater flow by introducing heterogeneity in permeability. We examine the hydrogeology of the Sandwich Fault Zone, a 137 km long zone of high-angle faults in northern Illinois, using a large-scale historic aquifer test. The fault zone is poorly understood at depth due to the majority of the faults being buried by glacial deposits and its near-vertical orientation which limits geologic sampling across faults. The aquifer test—perhaps one of the largest in terms of overall withdrawal in North American history—was conducted in 1942 at a facility adjacent to the fault zone. More than 34,000 m3/day was pumped for 37 days from nine multiaquifer wells open to the stratified Cambrian-Ordovician sandstone aquifer system. We modeled the aquifer test using a transient MODFLOW-USG model and simulated pumping wells with the CLN package. We tested numerous fault core/damage zone conceptualizations and calibrated to drawdown values recorded at production and observation wells. Our analysis indicates that the fault zone is a low-permeability feature that inhibits lateral movement of groundwater and that there is at least an order of magnitude decrease in horizontal hydraulic conductivity in the fault core compared to the undeformed sandstone. Large head declines have occurred north of the fault zone (over 300 m since predevelopment conditions) and modifying fault zone parameters significantly affects calibration to regional drawdown on a decadal scale. The flow-barrier behavior of the fault zone has important implications for future groundwater availability in this highly stressed region.  相似文献   

10.
We have investigated non‐Darcian flow to a vertical fracture represented as an extended well using a linearization procedure and a finite difference method in this study. Approximate analytical solutions have been obtained with and without the consideration of fracture storage based on the linearization procedure. A numerical solution for such a non‐Darcian flow case has also been obtained with a finite difference method. We have compared the numerical solution with the approximate analytical solutions obtained by the linearization method and the Boltzmann transform. The results indicate that the linearized solution agrees generally well with the numerical solution at late times, and underestimates the dimensionless drawdown at early times, no matter if the fracture storage is considered or not. When the fracture storage is excluded, the Boltzmann transform solution overestimates the dimensionless drawdown during the entire pumping period. The dimensionless drawdowns in the fracture with fracture storage for different values of dimensionless non‐Darcian hydraulic conductivity β approach the same asymptotic value at early times. A larger β value results in a smaller dimensionless drawdown in both the fracture and the aquifer when the fracture storage is included. The dimensionless drawdown is approximately proportional to the square root of the dimensionless time at late times.  相似文献   

11.
Aquifer information carried by aquifer test data may be affected by the presence of a finite thickness skin around the wellbore. The mathematical treatment for an aquifer accounting for the skin zone can be characterized by five parameters, that is, the outer radius of the skin zone and the transmissivity and storativity for each of the skin and aquifer zones. Sensitivity analysis was performed to examine the ground water flow behavior in the skin and aquifer zones in terms of the constant-head test (CHT) data. The simulated annealing procedure was applied to simultaneously determine the skin and aquifer parameters from the analysis of CHT data. Toward the previously mentioned goals, four suites of CHT data were analyzed in this article. The analyses of wellbore flow rate at the test well and the specific drawdown at the observation well gave accurate estimates for the skin and aquifer parameters, respectively. Only the skin thickness and both the skin and the aquifer diffusivities could be accurately estimated from the analysis of drawdown data in the observation well. The estimates for all skin and aquifer parameters from the composite analysis of flow rate and drawdown data were the most accurate. The results of sensitivity analyses and parameter estimations provide instructive references in the analysis of the skin-affected CHT data.  相似文献   

12.
The interaction between a gaining stream and a water-table aquifer is studied at an outwash plain. The aquifer is hydraulically well connected to the stream. Pumping tests were carried out in 1997 and 1998 in two wells 60 m from the stream, screening different depths of the aquifer. Drawdown was measured on both sides of the stream. Hydraulic head, drawdown, and stream depletion data were analyzed using numerical flow models. Similar models were fitted to each of two different data sets: Model A was fitted to steady-state hydraulic head and streamflow gain data not influenced by pumping; and model B was fitted to drawdown data measured during the 1998 pumping test. Each calibrated model closely fits its calibration data; however, predictions were biased if model A was used to predict the calibration data of model B, and vice versa. To further test the models, they were used to predict streamflow depletion during the two pumping tests as well as the drawdown during the 1997 test. Neither of these data were used for calibration. Model A predicted the measured depletions fairly accurately during both tests, whereas the predicted drawdowns in 1997 were significantly larger than actually measured. Contrary to this, the 1997 drawdowns predicted by model B were nearly unbiased; the predicted depletions deviate significantly from the measured depletions in 1997, but they compare well with the observations in 1998. Thus, although field work and analyses were extensive and done carefully to develop a ground water flow model that could predict both drawdown and streamflow depletion, the model predictions are biased. Analyses indicate that the deviations between model and data may be because of error in the models' representations of either the release of water from storage or of the hydrology in the riparian zone.  相似文献   

13.
Abstract. A method to calculate aquifer transmissivity, storage coefficient, and the leakage coefficient from pumping test data for a leaky aquifer is presented. The method is carried out by a computer program and is based on a minimization of the sum of squares of differences between drawdown in the observation well and the theoretical values from the Hantush and Jacob formula. No user defined starting points are necessary. Random error estimates for the parameters are given. Applications of the method are illustrated using data from pumping tests performed in leaky aquifers at the Cauca River Valley, Colombia.  相似文献   

14.
The Kuwait Group consists mainly of clastic sediments overlying unconformably the Dammam Formation of Tertiary age. The Kuwait Group is generally divided into three main hydrostratigraphic units: the upper and lower aquifers separated by an aquitard. The upper aquifer is further divided into the water table aquifer, an aquitard and a semiconfined aquifer. This semiconfined unit was pumped and the drawdowns were observed in piezometers screened in various subunits of the Kuwait Group. Some pumping tests of short duration were carried out in the top water table aquifer as well. These tests showed that the subunits of the Kuwait Group are hydraulically interconnected to a varying degree.

The pumping test data were analysed using conventional analytical solutions. The semiconfined pumping test was also simulated by a quasi-three-dimensional model using a leaky multiaquifer modelling technique. The initial hydraulic parameters were improved manually in the model till best fit drawdowns were obtained.

The final parameters obtained by simulation of the pumping tests were used in designing a pilot drainage system for the control of a rising groundwater table in parts of Kuwait City.  相似文献   


15.
Closed‐form solutions are proposed for natural seepage in semiconfined (leaky) aquifers such as those existing below the massive Champlain Sea clay layers in the Saint‐Lawrence River Valley. The solutions are for an ideal horizontal leaky aquifer below an ideal aquitard that may have either a constant thickness and a constant hydraulic head at its surface, or a variable thickness and a variable hydraulic head at its surface. A few simplifying assumptions were needed to obtain the closed‐form solutions. These have been verified using a finite element method, which did not make any of the assumptions but gave an excellent agreement for hydraulic heads and groundwater velocities. For example, the difference between the two solutions was smaller than 1 mm for variations in the 5 to 8 m range for the hydraulic head in the semiconfined aquifer. Note that fitting the hydraulic head data of monitoring wells to the theoretical solutions gives only the ratio of the aquifer and aquitard hydraulic conductivities, a clear case of multiple solutions for an inverse problem. Consequently, field permeability tests in the aquitard and the aquifer, and pumping tests in the aquifer, are still needed to determine the hydraulic conductivity values.  相似文献   

16.
Pumping test evaluation of stream depletion parameters   总被引:1,自引:0,他引:1  
Lough HK  Hunt B 《Ground water》2006,44(4):540-546
  相似文献   

17.
Langseth DE  Smyth AH  May J 《Ground water》2004,42(5):689-699
Predicting the future performance of horizontal wells under varying pumping conditions requires estimates of basic aquifer parameters, notably transmissivity and storativity. For vertical wells, there are well-established methods for estimating these parameters, typically based on either the recovery from induced head changes in a well or from the head response in observation wells to pumping in a test well. Comparable aquifer parameter estimation methods for horizontal wells have not been presented in the ground water literature. Formation parameter estimation methods based on measurements of pressure in horizontal wells have been presented in the petroleum industry literature, but these methods have limited applicability for ground water evaluation and are based on pressure measurements in only the horizontal well borehole, rather than in observation wells. This paper presents a simple and versatile method by which pumping test procedures developed for vertical wells can be applied to horizontal well pumping tests. The method presented here uses the principle of superposition to represent the horizontal well as a series of partially penetrating vertical wells. This concept is used to estimate a distance from an observation well at which a vertical well that has the same total pumping rate as the horizontal well will produce the same drawdown as the horizontal well. This equivalent distance may then be associated with an observation well for use in pumping test algorithms and type curves developed for vertical wells. The method is shown to produce good results for confined aquifers and unconfined aquifers in the absence of delayed yield response. For unconfined aquifers, the presence of delayed yield response increases the method error.  相似文献   

18.
Tomas Perina 《Ground water》2021,59(3):438-442
Time-domain analytical solution for groundwater flow to a fully penetrating flowing well is derived using the same substitution technique used to re-derive (Perina 2010) the Theis (1935) equation and the approximate solution by Mishra and Guyonnet (1992) is confirmed. The exponential integral-based flowing well function is a computationally effective alternative to the original Jacob and Lohman (1952) solution in integral form. For a constant drawdown test, the ratio of drawdown at an observation well to the flowrate is equivalent to drawdown response to pumping at unit constant rate; the transformed observations can be analyzed using the Theis (1935) function. Analysis of field test shows that simultaneous fitting to measurements of flow from the test well and drawdown at an observation well results in more accurate and better resolved estimates of aquifer properties than fitting to flow observations only.  相似文献   

19.
20.
The city of St. Petersburg has been testing subsurface injection of treated sewage into the Floridan aquifer as a means of eliminating discharge of sewage to surface waters and as a means of storing treated sewage for future non-potable reuse. The injection zone originally contained native saline ground water that was similar in composition to sea water. The zone has a transmissivity of about 1.2 X 106 feet squared per day (ft2/d) and is within the lower part of the Floridan aquifer. Treated sewage that had a mean chloride concentration of 170 milligrams per liter (mg/1) was injected through a single well for 12 months at a mean rate of 4.7 X 105 cubic feet per day (ft3/d). The volume of water injected during the year was 1.7 X 108 cubic feet. Pressure buildup at the end of one year ranged from less than 0.1 to as much as 2.4 pounds per square inch (lb/in2) in observation wells at the site. Pressure buildup in wells open to the upper part of the injection zone was related to buoyant lift acting on the mixed water in the injection zone in addition to subsurface injection through the injection well. Calculations of the vertical component of pore velocity in the semiconfining bed underlying the shallowest permeable zone of the Floridan aquifer indicate upward movement of native water. This is consistent with the 200- to 600-mg/l increase in chloride concentration observed in water from the shallowest permeable zone during the test.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号