首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Isotope dilution (ID) mass spectrometry is a primary method of analysis suited for the accurate and precise measurement of several trace elements in geological matrices. Here we present mass fractions and respective uncertainties for Cr, Cu, Ni, Sn, Sr and Zn in 10 silicate rock reference materials (BCR‐2, BRP‐1, BIR‐1, OU‐6, GSP‐2, GSR‐1, AGV‐1, RGM‐1, RGM‐2 and G‐3) obtained by the double ID technique and measuring the isotope ratios with an inductively coupled plasma‐mass spectrometer equipped with collision cell. Test portions of the samples were dissolved by validated procedures, and no further matrix separation was applied. Addition of spikes was designed to achieve isotope ratios close to unity to minimise error magnification factors, according to the ID theory. Radiogenic ingrowth of 87Sr from the decay of 87Rb was considered in the calculation of Sr mass fractions. The mean values of our results mostly agree with reference values, considering both uncertainties at the 95% confidence level, and also with ID data published for AGV‐1. Considering all results, the means of the combined uncertainties were < 1% for Sr, approximately 2% for Sn and Cu, 4% for Cr and Ni and almost 6% for Zn.  相似文献   

2.
We present new reference values for nineteen USGS, GSJ and GIT‐IWG rock reference materials that belong to the most accessed samples of the GeoReM database. The determination of the reference values and their uncertainties at the 95% confidence level follows as closely as possible ISO guidelines and the Certification Protocol of the International Association of Geoanalysts. We used analytical data obtained by the state‐of‐the‐art techniques published mainly in the last 20 years and available in GeoReM. The data are grouped into four categories of different levels of metrological confidence, starting with isotope dilution mass spectrometry as a primary method. Data quality was checked by careful investigation of analytical procedures and by the application of the Horwitz function. As a result, we assign a new and more reliable set of reference values and respective uncertainties for major, minor and a large group of trace elements of the nineteen investigated rock reference materials.  相似文献   

3.
Due to intensive research into selenium isotopes in recent years, the increasing requirement for reliable and comparable measurement results has created a strong demand for selenium isotopic certified reference materials (iCRM) that were previously not available. To address this, eleven selenium iCRMs were developed, including ten synthetic iCRMs (GBW 04447–GBW 04456) and one natural iCRM (GBW 04457). The synthetic iCRMs were prepared with 76Se, 78Se, 80Se and 82Se solutions and a natural selenium solution; the natural iCRM was prepared with highly pure selenium material. The property values of isotope ratios in these iCRMs were certified by calibrated mass spectrometry with a collision cell multi‐collector ICP‐MS. The mass discrimination effect of the instrument was corrected with corresponding 78Se/76Se isotope mixtures and 82Se/76Se isotope mixtures, which were gravimetrically prepared with purified, isotopically enriched selenium materials. Homogeneity and stability tests were performed, and no significant influences were found. The uncertainty of the property values of the iCRMs was evaluated according to the Guide to the Expression of Uncertainty in Measurement (GUM) of ISO/BIPM and ISO Guide 35. The δ82/76Se value of GBW 04457 relative to NIST SRM 3149 was also calculated. These iCRMs are intended for use in calibration of instruments and evaluation of methods for the determination of selenium isotope ratios.  相似文献   

4.
This article presents new boron concentrations for nine geochemical reference materials (GS‐N, FK‐N, GL‐O, BX‐N, DT‐N, AN‐G, GH, Mica‐Fe, Mica‐Mg). After extraction by a modified pyrohydrolysis technique, boron concentrations were measured by ICP‐MS. The blank levels for the whole procedure were 0.091 ± 0.020 ng ml?1 or 14 ± 5 ng of boron in total. The method was first validated by measuring nine reference materials with known boron concentrations. The determined boron concentrations are all within the range of recommended or published values, which means that the yields were 100%, and show precisions below 10% for samples containing over 2 μg g?1 of boron.  相似文献   

5.
Iron Isotopic Compositions of Geological Reference Materials and Chondrites   总被引:2,自引:0,他引:2  
High‐precision iron isotopic compositions for Fe‐bearing geological reference materials and chondrites with a wide range of matrices (e.g., silicates, oxides, organic‐bearing materials) are reported. This comprehensive data set should serve as a reference for iron isotopic studies across a range of geological and biological disciplines for both quality assurance and inter‐laboratory calibration. Where comparison is available, the iron isotopic compositions of most geological reference materials measured in this study were in agreement with previously published data within quoted uncertainties. Recommendations for the reporting of future iron isotopic data and associated uncertainties are also presented. Long‐term repeat analyses of all samples indicate that highly reproducible iron isotopic measurements are now obtainable (± 0.03‰ and ± 0.05‰ for δ56Fe and δ57Fe, respectively).  相似文献   

6.
Here we describe high‐precision molybdenum isotopic composition measurements of geological reference materials, performed using multi‐collector inductively coupled plasma‐mass spectrometry (MC‐ICP‐MS). Purification of Mo for isotopic measurements was achieved by ion exchange chromatography using Bio‐Rad AG® 1‐X8 anion exchange resin. Instrumental mass bias was corrected using 100Mo‐97Mo double spiking techniques. The precision under intermediate measurement conditions (eighteen measurement sessions over 20 months) in terms of δ98/95Mo was 0.10‰ (2s). The measurement output was approximately four times more efficient than previous techniques, with no compromise in precision. The Mo isotopic compositions of seven geochemical reference materials, seawater (IAPSO), manganese nodules (NOD‐P‐1 and NOD‐A‐1), copper‐molybdenum ore (HV‐2), basalt (BCR‐2) and shale (SGR‐1b and SCo‐1), were measured. δ98/95Mo values were obtained for IAPSO (2.25 ± 0.09‰), NOD‐P‐1 (?0.66 ± 0.05‰), NOD‐A‐1 (?0.48 ± 0.05‰), HV‐2 (?0.23 ± 0.10‰), BCR‐2 (0.21 ± 0.07‰), SCo‐1 (?0.24 ± 0.06‰) and SGR‐1b (0.63 ± 0.02‰) by calculating δ98/95Mo relative to NIST SRM 3134 (0.25‰, 2s). The molybdenum isotopic compositions of IAPSO, NOD‐A‐1 and NOD‐P‐1 obtained in this study are within error of the compositions reported previously. Molybdenum isotopic compositions for BCR‐2, SCo‐1 and SGR‐1b are reported for the first time.  相似文献   

7.
Recent analytical developments in germanium stable isotope determination by multicollector ICP‐MS have provided new perspectives for the use of Ge isotopes as geochemical tracers. Here, we report the germanium isotope composition of the NIST SRM 3120a elemental reference solution that has been calibrated relative to internal isotopic standard solutions used in the previous studies. We also intercalibrate several geological reference materials as well as geological and meteoritic samples using different techniques, including online hydride generation and a spray chamber for sample introduction to MC‐ICP‐MS, and different approaches for mass bias corrections such as sample–calibrator bracketing, external mass bias correction using Ga isotopes and double‐spike normalisation. All methods yielded relatively similar precisions at around 0.1‰ (2s) for δ74/70Ge values. Using igneous and mantle‐derived rocks, the bulk silicate Earth (BSE) δ74/70Ge value was re‐evaluated to be 0.59 ± 0.18‰ (2s) relative to NIST SRM 3120a. Several sulfide samples were also analysed and yielded very negative values, down to ?4.3‰, consistent with recent theoretical study of Ge isotope fractionation. The strong heavy isotope depletion in ore deposits also contrasts with the generally positive Ge isotope values found in many modern and ancient marine sediments.  相似文献   

8.
The commonly used, but no longer available, reference materials NIST SRM 976 (Cu) and ‘JMC Lyon’ (Zn) were calibrated against the new reference materials ERM®‐AE633, ERM®‐AE647 (Cu) and IRMM‐3702 (Zn), certified for isotope amount ratios. This cross‐calibration of new with old reference materials provides a continuous and reliable comparability of already published with future Cu and Zn isotope data. The Cu isotope amount ratio of NIST SRM 976 yielded δ65/63Cu values of ?0.01 ± 0.05‰ and ?0.21 ± 0.05‰ relative to ERM®‐AE633 and ERM®‐AE647, respectively, and a δ66/64ZnIRMM‐3702 value of ?0.29 ± 0.05‰ was determined for ‘JMC Lyon’. Furthermore, we separated Cu and Zn from five geological reference materials (BCR‐2, BHVO‐2, BIR‐1, AGV‐1 and G‐2) using a two‐step ion‐exchange chromatographic procedure. Possible isotope fractionation of Cu during chromatographic purification and introduction of resin‐ and/or matrix‐induced interferences were assessed by enriched 65Cu isotope addition. Instrumental mass bias correction for the isotope ratio determinations by MC‐ICP‐MS was performed using calibrator‐sample bracketing with internal Ni doping for Cu and a double spike approach for Zn. Our results for the five geological reference materials were in very good agreement with literature data, confirming the accuracy and applicability of our analytical protocol.  相似文献   

9.
We present the first measurements of vanadium (V) stable isotopes for six reference materials – USGS PCC‐1, BHVO‐2, BCR‐2, BIR‐1a, GSP‐2 and AGV‐2 – plus the widely available carbonaceous chondrite Allende. We present standard addition and matrix spiking tests to assess the robustness and reproducibility of our data. Standard addition utilised an enriched 50V solution designated VISSOX (Vanadium Isotope Standard Solution OXford). We further assessed the veracity of the method by spiking collected sample matrices with the same amount of a V standard solution, whose isotopic composition was defined as 0‰. Standard addition and matrix spiking tests recorded no appreciable artificial isotope fractionation. We estimate that the best currently attainable long‐term reproducibility of stable 51V/50V isotope measurements in complex matrices is 0.15‰, which is in the same order as the reproducibility achievable with standard solutions. Finally, a large range of ~ 1.2‰ in stable V isotopic composition was documented, with ~ 0.5‰ of that variation in high temperature igneous materials alone. The range and resolving power of V stable isotopes, with respect to igneous material, compared favourably with the magnitude of fractionation reported for other non‐traditional stable isotope systems, which bodes well for the utility of this new system.  相似文献   

10.
We report high‐precision iron isotopic data for twenty‐two commercially available geological reference materials, including silicates, carbonatite, shale, carbonate and clay. Accuracy was checked by analyses of synthetic solutions with known Fe isotopic compositions but different matrices ranging from felsic to ultramafic igneous rocks, high Ca and low Fe limestone, to samples enriched in transition group elements (e.g., Cu, Co and Ni). Analyses over a 2‐year period of these synthetic samples and pure Fe solutions that were processed through the whole chemistry procedure yielded an average δ56Fe value of ?0.001 ± 0.025‰ (2s, n = 74), identical to the expected true value of 0. This demonstrates a long‐term reproducibility and accuracy of < 0.03‰ for determination of 56Fe/54Fe ratios. Reproducibility and accuracy were further confirmed by replicate measurements of the twenty‐two RMs, which yielded results that perfectly match the mean values of published data within quoted uncertainties. New recommended values and associated uncertainties are presented for interlaboratory calibration in the future.  相似文献   

11.
Over 1400 electron probe and 700 ion probe microanalyses were performed on eleven mineral separates to evaluate their potential as reference materials for in situ Li isotopic determination. Our results suggest the homogenous distributions of major elements, Li and its isotopes for each sample. Hence, these samples are suitable to be used as reference materials for in situ measurements of Li abundance and Li isotopes by secondary ion mass spectrometry (SIMS) or laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS). These samples have the advantage of mitigating probable matrix effects during calibration owing to the wide range of compositions. The effect of composition on the δ7Li of olivine measured by SIMS is a linear function of composition, with δ7Li increasing by 1.0‰ for each mole per cent decrease in forsterite component.  相似文献   

12.
Although initial studies have demonstrated the applicability of Ni isotopes for cosmochemistry and as a potential biosignature, the Ni isotope composition of terrestrial igneous and sedimentary rocks, and ore deposits remains poorly known. Our contribution is fourfold: (a) to detail an analytical procedure for Ni isotope determination, (b) to determine the Ni isotope composition of various geological reference materials, (c) to assess the isotope composition of the Bulk Silicate Earth relative to the Ni isotope reference material NIST SRM 986 and (d) to report the range of mass‐dependent Ni isotope fractionations in magmatic rocks and ore deposits. After purification through a two‐stage chromatography procedure, Ni isotope ratios were measured by MC‐ICP‐MS and were corrected for instrumental mass bias using a double‐spike correction method. Measurement precision (two standard error of the mean) was between 0.02 and 0.04‰, and intermediate measurement precision for NIST SRM 986 was 0.05‰ (2s). Igneous‐ and mantle‐derived rocks displayed a restricted range of δ60/58Ni values between ?0.13 and +0.16‰, suggesting an average BSE composition of +0.05‰. Manganese nodules (Nod A1; P1), shale (SDO‐1), coal (CLB‐1) and a metal‐contaminated soil (NIST SRM 2711) showed positive values ranging between +0.14 and +1.06‰, whereas komatiite‐hosted Ni‐rich sulfides varied from ?0.10 to ?1.03‰.  相似文献   

13.
The preparation and characterisation of four chromium ore reference materials are described in this paper. The sample material for GCr‐1, GCr‐3 and GCr‐4 was collected from chromite deposits in Tibet, Qinghai province and Inner Mongolia. GCr‐2 is a composite sample from GCr‐1 and GCr‐4. Sample homogeneity was tested by WD‐XRF and the relative standard deviations were < 1.0%. An F‐test showed that all four materials were homogeneous. Thirteen laboratories involved in the inter‐laboratory programme provided 672 determinations (eighteen oxides and elements). Sixteen components were characterised as certified values, of which Cr2O3 ranged from 17.59 to 57.80% m/m. The contents of FeO and CO2 were taken as reference values.  相似文献   

14.
An organic solvent‐free two‐step column procedure is presented that provided robust, high yield and super clean separation of Li from silicate rock sample matrices. The measured δ7Li value for BHVO‐2 of +4.29 ± 0.23‰ (1s) is comparable with the reported values. The δ7Li values for GSJ JP‐1 (+3.14 ± 0.41‰, 1s) and USGS DTS‐2 (+4.91 ± 0.34‰, 1s) presented here provide new reference values for ultramafic rock reference materials.  相似文献   

15.
The Institute of Hydrogeology and Environmental Geology, Chinese Academy of Geological Sciences recently prepared four certified reference materials for hydrogen and oxygen stable isotopes in water, which are called ‘China Standard Water' (CSW)‐HO1–HO4 (hereafter referred to as HO1–HO4). These reference materials are intended for calibration purposes and provide reference values of their relative difference in 2H/1H and 18O/16O isotope‐amount ratios expressed in delta notation, normalised to the VSMOW–SLAP scale. The certified values of the reference materials were determined by an interlaboratory comparison of results from eleven participating laboratories. This paper describes in detail the production and certification procedure of the four reference materials. The first analytical data for the reference materials are also provided using a variety of analytical techniques, namely CO2–H2O equilibration and laser spectroscopy for δ18O and Cr reduction, as well as H2–H2O equilibration, laser spectroscopy, and high‐temperature conversion for δ2H. The reference values for materials HO1–HO4 and their associated uncertainties are assigned.  相似文献   

16.
The IAG conducts two programmes, the GeoPT ? proficiency test and a certification programme that are closely interconnected. Both support the quality control/quality assurance activities of geochemical laboratories. Each derives an estimate of ‘true value’ for a number of samples, but arrives at that estimate, and its uncertainty, differently. This review discusses the history of the two programmes and compares the ‘true values’ and their uncertainties obtained through each. It then considers ‘fitness‐for‐purpose’ issues related to both GeoPT ? and certification uncertainties. Issues related to potential modification of the IAG protocol for certification are also considered.  相似文献   

17.
Magnesium isotopic compositions are reported for twenty‐four international geological reference materials including igneous, metamorphic and sedimentary rocks, as well as phlogopite and serpentine minerals. The long‐term reproducibility of Mg isotopic determination, based on 4‐year analyses of olivine and seawater samples, was ≤ 0.07‰ (2s) for δ26Mg and ≤ 0.05‰ (2s) for δ25Mg. Accuracy was tested by analysis of synthetic reference materials down to the quoted long‐term reproducibility. This comprehensive dataset, plus seawater data produced in the same laboratory, serves as a reference for quality assurance and inter‐laboratory comparison of high‐precision Mg isotopic data.  相似文献   

18.
In this study, a high‐precision method for the determination of Sm and Nd concentrations and Nd isotopic composition in highly depleted ultramafic rocks without a preconcentration step is presented. The samples were first digested using the conventional HF + HNO3 + HClO4 method, followed by the complete digestion of chromite in the samples using HClO4 at 190–200 °C and then complete dissolution of fluoride formed during the HF decomposition step using H3BO3. These steps ensured the complete digestion of the ultramafic rocks. The rare earth elements (REEs) were separated from the sample matrix using conventional cation‐exchange chromatography; subsequently, Sm and Nd were separated using the LN columns. Neodymium isotopes were determined as NdO+, whereas Sm isotopes were measured as Sm+, both with very high sensitivity using single W filaments with TaF5 as an ion emitter. Several highly depleted ultramafic rock reference materials including USGS DTS‐1, DTS‐2, DTS‐2b, PCC‐1 and GSJ JP‐1, which contain extremely low amounts of Sm and Nd (down to sub ng g?1 level), were analysed, and high‐precision Sm and Nd concentration and Nd isotope data were obtained. This is the first report of the Sm‐Nd isotopic compositions of these ultramafic rock reference materials except for PCC‐1.  相似文献   

19.
The double‐spike method with multi‐collector inductively coupled plasma‐mass spectrometry was used to measure the Mo mass fractions and isotopic compositions of a set of geological reference materials including the mineral molybdenite, seawater, coral, as well as igneous and sedimentary rocks. The long‐term reproducibility of the Mo isotopic measurements, based on two‐year analyses of NIST SRM 3134 reference solutions and seawater samples, was ≤ 0.07‰ (two standard deviations, 2s, n = 167) for δ98/95Mo. Accuracy was evaluated by analyses of Atlantic seawater, which yielded a mean δ98/95Mo of 2.03 ± 0.06‰ (2s, n = 30, relative to NIST SRM 3134 = 0‰) and mass fraction of 0.0104 ± 0.0006 μg g?1 (2s, n = 30), which is indistinguishable from seawater samples taken world‐wide and measured in other laboratories. The comprehensive data set presented in this study serves as a reference for quality assurance and interlaboratory comparison of high‐precision Mo mass fractions and isotopic compositions.  相似文献   

20.
This study presents an experimental procedure to fabricate high‐purity silica glass containing a selected element at a specified mass fraction. The procedure was used to prepare glasses doped with trace‐level mass fractions of Ti with the goal of improving analytical confidence when measuring trace elements in quartz. Systematic tests were performed to determine the ideal conditions and procedures for doping nanoporous silica gel with the highest efficiency of dopant recovery. Silica gel was cleaned in concentrated HCl, immersed in a non‐polar doping medium at a controlled pH and doped with precise quantities of ICP‐MS standard solution. Using liquids composed of longer chain molecules as the doping medium diminishes recovery, suggesting that large molecules could obstruct nanopores to inhibit capillary uptake of the dopant. A control experiment using crystalline quartz reinforced the effectiveness of nanoporous silica gel for doping with trace‐level precision. Layered aggregates of silica gel doped with different Ti mass fractions were hot‐pressed to create multi‐layered reference materials that were analysed with multiple techniques at a variety of spatial scales. Analyses at the intra‐grain scale (cathodoluminescence scanning electron microscopy, electron probe microanalysis), at the single grain scale (SIMS), at the sample layer scale (EPMA, laser ablation‐ICP‐MS) and at the bulk scale (ICP‐OES) demonstrated acceptable homogeneity at sample volumes characteristic of most microanalysis techniques and show that nanoporous silica gel holds promise as a highly retentive doping substrate for preparing reference materials for laser‐, electron‐ and ion‐beam microanalysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号