首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 760 毫秒
1.
Horizontal air sparging (HASP) wells offer several potential advantages compared to linear arrays of vertical air sparging wells. For some of these advantages to be realized, however, HASP wells must be able to deliver air uniformly along the length of the well. HASP wells can fail to deliver air uniformly for either engineering or geological reasons.
A 58 m (190-foot) long HASP well, with a 15 m (50-foot) long screen interval, was designed, installed, and tested in eolian dune sand. The relative uniformity of the geologic medium allowed specific evaluation of the impact of the well design on air delivery. A variety of monitoring approaches were used during a six-day pilot test. Pressure drop within the sparge well was found to be negligible through the screen interval of the well. Soil gas pressure and ground water mounding responses were very similar at both ends of the well screen, suggesting relatively uniform air delivery throughout. Electrical resistance tomography results confirmed that airflow in the formation was similar at both ends of the screen interval and that the principal region of airflow was within 1.5 m (5 feet) of the axis of the well. Increased dissolved oxygen was primarily limited to a region within 2.3 m (7.5 feet) of the well and occurred throughout the length of the screen interval. These monitoring results show that HASP wells, properly constructed and installed, can supply air in a generally uniform manner along their length.  相似文献   

2.
The objective of this study was to assess the possible impact of deep well disposal operations, conducted between 1958 and 1974, on the ground water quality in a shallow fresh water aquifer beneath Sarnia, Ontario, Canada. Because of the breakout of formation fluids in Sarnia and Port Huron, Michigan, in the early 1970s, it had been hypothesized that liquid waste from the disposal zone in bedrock had leaked through numerous abandoned oil, gas, and salt wells in the area up to the shallow fresh water aquifer and from there to the surface.
A monitoring well network of 29 5cm (2 inch) diameter piezometers was established in the thin sand and shale aquifer system, which exists between 30 and 70m (100 and 230 feet) below ground surface. In addition, a 300m (1000 foot) deep borehole was drilled and instrumented with a Westbay multilevel casing, which permitted sampling of the disposal zone.
Ground water samples from the shallow monitoring wells and the Westbay multilevel casing were analyzed for volatiles by GC/MS. Those volatile aromatics that were conspicuously present in the deep disposal zone, e.g., ethyl toluenes and trimethyl benzene, were not detected in the shallow monitoring wells. Thus, if contaminants from the disposal zone did indeed migrate to the shallow aquifer, contamination was not widespread and probably consisted mostly of displaced chloride-rich formation waters.  相似文献   

3.
Hydrogeologic and ground water quality data obtained from a gas-driven multilevel sampler system and a polyvinyl chloride (PVC) monitoring well nest with the same aquifer communication intervals are compared. All monitoring points are in close proximity to each other. The study was conducted at an eight-acre uncontrolled hazardous waste site. The site is located in an alluvial valley composed of approximately 40 feet of alluvium overlying shale bedrock. The ground water at the site is contaminated with various organic constituents. A ground water monitoring network consisting of 26 conventional monitoring wells, nine observation well points, and six multilevel gas-driven samplers was established to characterize the hydrogeologic regime and define the vertical and horizontal extent of contamination in the vicinity of the abandoned chemical plant. As part of this study, a multilevel monitoring system was installed adjacent to a well nest. The communication zones of the multilevel samplers were placed at the same elevation as the sand packs of the well nest. The multilevel sampler system and well nest are located in a contaminated area directly downgradient of the site. A comparison of the vertical head distribution and ground water quality was performed between the well nest and the multilevel sampling system. The gas-driven multilevel sampling system consists of three gas-driven samplers that monitor separate intervals in the unconsolidated materials. The well nest, composed of two PVC monitoring wells in separate boreholes, has the same communication interval as the other two gas-driven samplers. Hydraulic head information for each multilevel sampler was obtained using capillary tubing. This was compared with heads obtained from the well nest utilizing an electric water level indicator. Chemical analyses from the PVC and multilevel sampler wells were performed and compared with one another. The analyses included organic acids, base neutrals, pesticides, PCBs, metals, volatile organics, TOX, TOC, CN, pH and specific conductance.  相似文献   

4.
The results of an API-sponsored pilot-scale subsurface venting system study are presented. The purpose of this study was to evaluate the effectiveness of forced venting techniques in controlling and removing hydrocarbon vapors from a subsurface formation. Both qualitative and quantitative sampling and analytical procedures were developed to measure hydrocarbon vapors extracted from the soil. Vapor recovery and equivalent liquid product recovery rates were measured at each test cell evacuation rate.
Two identical test cells were installed. Each cell contained 16 vapor monitoring probes spaced at distances from 4 to 44 feet from a vapor extraction (vacuum) well. Each cell was also configured with two air inlet wells to allow atmospheric air to enter the subsurface formation. The vapor monitoring probes were installed at three discrete elevations above the capillary zone. In situ vapor samples were obtained periodically from these probes to measure changes in vapor concentration and composition while extracting vapors from the vacuum well at three different flow rates (18.5 scfm, 22.5 scfm and 39.8 scfm). In situ vapor samples were analyzed using a portable gas chromatograph to quantify and speciate the vapors. Vacuum levels were also measured at each vapor sampling probe and at the vacuum well.
The soil venting techniques evaluated during this study offer an alternative approach for controlling and eliminating spilled or leaked hydrocarbons from sand or gravel formations of high porosity and moderate permeability. These techniques may also be used to augment conventional liquid recovery methods. The data collected during this study will be useful in optimizing subsurface venting systems for removing and controlling hydrocarbon vapors in soil. Study results indicate pulsed venting techniques may offer a cost-effective means of controlling or eliminating hydrocarbon vapors in soil.  相似文献   

5.
The HydraSleeve is a sampling device for collecting groundwater from the screened interval of a monitoring well without purging that uses a check valve to take in water over the first 3 to 5 feet of an upward pulling motion. If the check valve does not perform as expected, then the HydraSleeve has the potential to collect water from an incorrect depth interval, possibly above the screened interval of the well. We have evaluated volatile organic chemical (VOC) results from groundwater samples collected with the HydraSleeve sampler compared to other methods for sampling monitoring wells at three sites. At all three sites, lower VOC concentration results were observed for samples collected using the HydraSleeve. At two of these three sites, the low concentration sample results were most strongly associated with monitoring wells with more than 10 feet of water above the monitoring well‐screened interval. At the site with the largest dataset, the median bias for samples collected with HydraSleeve was ?20% (p < 0.001). At this site, a bias of ?26% (p < 0.001) was observed for the subset of monitoring wells with greater than 10 feet of water above the screened interval compared to a bias of ?7% (p = 0.21) for wells screened across the top of the water table. In addition to lower VOC concentrations, the monitoring records obtained using the HydraSleeve were more variable compared to monitoring records obtained using purge sampling methods, a characteristic that would make it more difficult to determine the long‐term concentration trend in the well.  相似文献   

6.
The union of a piezoresistive pressure transducer and a porous ceramic cup was termed "transiometer." The transiometer was constructed from economical and readily available materials. It could be used to measure soil water potentials in both saturated and unsaturated conditions, and was well suited to continuous monitoring with data acquisition equipment.
Transiometer testing was conducted at two sites, one of moderate permeability and the other of slow permeability. The slowly permeable site was instrumented with four replications of the following: (1) transiometers installed at four depths, (2) a transi-ometerwithout the ceramic cup, (3) apiezometer, and (4) access tubes for monitoring soil moisture with a neutron probe. The moderately permeable site was instrumented with a transiometer, two piezometers, and an access tube for monitoring with a neutron probe.
In saturated conditions the transiometer had a faster response time after installation than the piezometer. Faster response makes the transiometer more desirable for use in slowly permeable soils, especially when monitoring dynamic soil water.
Calculated random error of the transiometer measuring system, including a digital voltmeter and a scanner, was typically 0.09 feet (2.8cm), with a maximum calculated to be 0.38 feet (11.5cm). The two most significant components were imprecision of the scanner card and calibration shift. The transiometer was sensitive to atmospheric pressure fluctuations, with sensitivity to atmospheric pressure change increasing with installation depth.  相似文献   

7.
Extreme heterogeneity of karst systems makes them very challenging to study. Various processes within the system affect its global response, usually measured at karst springs. Research conducted in caves provides a unique opportunity for in situ analysis of separate processes in karst underground. The aim of the present study was to research the water and air dynamics within a deep karst system. Air and water basic physical parameters across the Lukina jama–Trojama cave system (?1,431 m) were continuously monitored during a 1‐year period. Recorded hydrograph of the siphon lake at the bottom of the cave was used to interpret the characteristics of an unexplored phreatic/epiphreatic conduit network. Water origin in the siphon was determined based on temperature and electrical conductivity. Air temperature and humidity monitoring revealed a strong inflow of air of sub‐zero temperature into the upper portion of the cave during winter. Cave passage morphology was interpreted as the main determinant of air dynamics, which caused ice to accumulate extensively in the upper portions of the cave and caused the temperature on the top of the homothermic zone to be significantly below the mean outside temperature. Air dynamics also lowered the temperature of water flowing through the cave vadose zone and feeding the phreatic zone of the massif. The pronounced temperature difference between the phreatic zone and the top of the homothermic zone probably contributed to the thermal gradient observed in the cave, which is steeper than in ice‐free caves in the area. Our results enabled the development of a conceptual model that describes coupling between air and water dynamics in the cave system and its surroundings.  相似文献   

8.
Studies published in the late 1990s and early 2000s identified the presence of exceptionally long methyl tert‐butyl ether (MTBE) plumes (more than 600 m or 2000 feet) in groundwater and have been cited in technical literature as characteristic of MTBE plumes. However, the scientific literature is incomplete in regard to the subsequent behavior and fate of these MTBE plumes over the past decade. To address this gap, this issue paper compiles recent groundwater monitoring records for nine exceptional plumes that were identified in prior studies. These nine sites exhibited maximum historical MTBE groundwater plume lengths ranging from 820 m (2700 feet) to 3200 m (10,500 feet) in length, exceeding the lengths of 99% of MTBE plumes, as characterized in multiple surveys at underground storage tank sites across the United States. Groundwater monitoring data compiled in our review demonstrate that these MTBE plumes have decreased in length over the past decade, with five of the nine plumes exhibiting decreases of 75% or more compared to their historical maximum lengths. MTBE concentrations within these plumes have decreased by 93% to 100%, with two of the nine sites showing significant decreases (98% and 99%) such that the regulatory authority has subsequently designated the site as requiring no further action.  相似文献   

9.
The site characterization and analysis cone penetrometer system (SCAPS), equipped with realtime fluorophore detection capabilities, was used to delineate subsurface contaminant releases in an area where plating shop waste was temporarily stored. Records indicated that various nonaqueous phase liquids (NAPLs) were released at the site. The investigators advanced the SCAPS laser-induced fluorescence (LIF) sensor to depths beneath the water table of the principal water-bearing zone. The water table was located approximately 6 feet (1.8 m) below ground surface (bgs) across the site. Fluorescence, attributed to fuel compounds commingled with chlorinated solvents, was observed at depths ranging from 4.0 to 11.5 feet (1.2 to 3.5 m) bgs. Fluorescence, attributed to naturally occurring organic materials (by process of elimination and spectral characteristics) commingled with chlorinated solvent constituents, was observed at depths ranging from approximately 13 to 40 feet (4.0 to 12.2 m) bgs. Fluorescence responses from compounds confirmed to be commingled with chlorinated solvents indicates that the SCAPS fluorophore detection system is capable of indirectly delineating vadose zone and subaqueous chlorinated solvents and other dense nonaqueous phase liquids (DNAPLs) at contaminant release sites. This confirmation effort represents the first documented account of the successful application of LIF to identify a mixed DNAPL/LNAPL source zone.  相似文献   

10.
Sampling of soil pore moisture in the vadose zone underneath land disposal facilities (landfills and surface impoundments) for hazardous waste has been suggested as an "early warning system" to detect leakage from these facilities. Some states require vadose zone moisture sampling at such sites. Given a leak of a particular size, mathematical models can estimate the necessary moisture sample volume collection times and lysimeter spacings to guarantee detection of the leak in a homogeneous medium. Examination of 47 hazardous waste sites existing in 1984 indicated the most were located in areas with water tables too shallow to permit vadose zone detection monitoring. Several of the 47 sites had soils that could be described as loamy sand, silt loam or silty clay. Using these three soils as examples, the process of lysimeter leak-detector network design has been illustrated. For a particular loamy sand with a saturates hydraulic conductivity of 10-6 cm/ sec, the maximum ceramic lysimeter spacing is 15.5 feet at a depth of 30 feet to collec a moisture sample of 10 mL in one week from a 1 ft2 leak. For a silt loam, maximum lysimeter spacing would be 17 feet at depth of 15 feet. For silty clays, the maximum lysimeter spacing is 7 feet at a depth of 2 feet; maximum emplacement depth is about 9 feet. Calculations show that in some soils, suction lysimeters will not be able to collect usable moisture samples. Since soil properties vary widely and lysimeter spacing is strongly dependent on soil-moisture characteristics appropriate soil measurements and modeling must be performed at each disposal facility to estimate lysimete performance and to select locations for emplacement.  相似文献   

11.
A new method is developed to design a multi-objective and multi-pollutant sensitive air quality monitoring network (AQMN) for an industrial district. A dispersion model is employed to estimate the ground level concentration of the air pollutants emitted from different emission sources. The primary objective of AQMN is providing the maximum information about the pollutant with respect to (1) maximum coverage area, (2) maximum detection of violations over ambient air standards and (3) sensitivity of monitoring stations to emission sources. Ant Colony Optimization algorithm (ACO) and Genetic Algorithm (GA) are adopted as the optimization tools to identify the optimal configuration of the monitoring network. The comparison between the results of ACO and GA shows that the performance of both algorithms is acceptable in finding the optimal configuration of AQMN. The application of the method to a network of existing refinery stacks indicates that three stations are suitable to cover the study area. The sensitivity of the three optimal station locations to emission sources is investigated and a database including the sensitivity of stations to each source is created.  相似文献   

12.
金沙江下游梯级水电站水库地震地下水动态监测网(简称金沙江水网),是中国第2个专门用于水库区地震前兆监测与研究为目的的企业地下水动态监测网.文中简要介绍了该网的布设、观测网的技术构成、观测井与观测含水层的基本特征及试运行的基本结果,从观测井-含水层特征及观测到的水位与水温多月、月、日动态特征,评估了其地震前兆监测能力.  相似文献   

13.
The impact of lost circulation during rotary drilling near an existing monitoring well cluster was evaluated by periodic measurements of water levels and contaminant concentrations at the well cluster. Due to regulatory concerns, changes in water levels or VOC concentration in the well cluster during drilling would trigger monitoring well redevelopment. The borehole was drilled approximately 30 feet northeast of four nested monitoring wells that screen Devonian and Silurian carbonate bedrock at depths of 15, 60, 130, and 190 feet. Following complete circulation loss at depths of 177 and 1 S3 feet in the borehole, a rapid decrease in water levels was observed in the upper three monitoring wells. The water level in the well that was screened through the lost circulation zones increased slightly.
Decreasing water levels in formations located above the point of circulation loss appear to occur in response to a sudden decrease in borehole fluid pressure caused by the flow of drilling fluid into the formation. The relative contribution of contaminated formation water lo the borehole can be estimated by using the time-drawdown relationship and estimates of transmissivity. At the point of circulation loss, significant dilution of contaminant concentrations occurs from the loss of drilling fluid into the contaminated zone. Contaminated formation water entering the borehole during periods of complete lost circulation may mobilize contaminants from upper lo lower formations. Lost circulation into a formation would be signaled by a water level increase in monitoring wells. The wells would subsequently require development to remove the volume of fluid lost to the formation, including both drilling fluid and contaminated formation water. Monitoring wells exhibiting declining water levels following lost circulation would not require development since drilling water has not entered the zones screened by these wells.  相似文献   

14.
Noxious weeds threaten the Sheyenne National Grassland (SNG) ecosystem and therefore herbicides have been used for control. To protect groundwater quality, the herbicide application is restricted to areas where the water table is less than 10 feet (3.05 m) below the ground surface in highly permeable soils, or less than 6 feet (1.83 m) below the ground surface in low permeable soils. A local MODFLOW model was extracted from a regional GFLOW analytic element model and used to develop depth‐to‐groundwater maps in the SNG that are representative for the particular time frame of herbicide applications. These maps are based on a modeled groundwater table and a digital elevation model (DEM). The accuracy of these depth‐to‐groundwater maps is enhanced by an artificial neural networks (ANNs) interpolation scheme that reduces residuals at 48 monitoring wells. The combination of groundwater modeling and ANN improved depth‐to‐groundwater maps, which in turn provided more informed decisions about where herbicides can or cannot be safely applied.  相似文献   

15.
Burbey TJ 《Ground water》2008,46(2):202-211
A 62 day controlled aquifer test was conducted in thick alluvial deposits at Mesquite, Nevada, for the purpose of monitoring horizontal and vertical surface deformations using a high-precision global positioning system (GPS) network. Initial analysis of the data indicated an anisotropic aquifer system on the basis of the observed radial and tangential deformations. However, new InSAR data seem to indicate that the site may be bounded by an oblique normal fault as the subsidence bowl is both truncated to the northwest and offset from the pumping well to the south. A finite-element numerical model was developed using ABAQUS to evaluate the potential location and hydromechanical properties of the fault based on the observed horizontal deformations. Simulation results indicate that for the magnitude and direction of motion at the pumping well and at other GPS stations, which is toward the southeast (away from the inferred fault), the fault zone (5 m wide) must possess a very high permeability and storage coefficient and cross the study area in a northeast-southwest direction. Simulated horizontal and vertical displacements that include the fault zone closely match observed displacements and indicate the likelihood of the presence of the inferred fault. This analysis shows how monitoring horizontal displacements can provide valuable information about faults, and boundary conditions in general, in evaluating aquifer systems during an aquifer test.  相似文献   

16.
The Effect of Three Drilling Fluids on Ground Water Sample Chemistry   总被引:1,自引:0,他引:1  
Three monitoring wells were installed in borings that were constructed using water-based drilling fluids containing either (1) guar bean, (2) guar bean with breakdown additive, or (3) bentonite. These fluids were selected to observe their effect on the chemistry of subsequent water samples collected from the wells. The wells were installed to depths of 66 feet, 100.5 feet and 103 feet, respectively, in fine-to-medium sand and gravel outwash deposits near Antigo, Wisconsin. Drilling fluids were necessary to maintain an open borehole during well construction through strata containing cobbles and boulders.
The bentonite and guar drilling fluids caused temporarily elevated concentrations of chemical oxygen demand (COD) in ground water samples collected from the monitoring wells. Using standard development, purging and sampling procedures, elevated COD concentrations persisted for about 50 days for the well bored with the guar-with-additive fluid, 140 days for the bentonite well and 320 days for the guar well. Unfiltered ground water samples for all wells had greater concentrations of COD than samples filtered through a 0.45 micron filter. Sulfate concentrations also decreased with time in the guar-with-additive well and bentonite well, but not in the guar well.
The elevated COD concentrations are attributed to the large concentrations of oxidizable carbon present in the guar bean drilling fluid and in the organic polymers present in the bentonite drilling fluid. Well development and purging procedures, including borehole flushing, surging, bailing and/or chemically induced viscosity breakdown of the guar mud decreased the time before background conditions were achieved. Future research should evaluate the physical and geochemical interaction of different drilling fluid compositions with a variety of geologic matrices and drilling, well development and well purging techniques.  相似文献   

17.
针对地震野外流动观测网络系统的无公用网络、流动性强、范围广、密度大、环境复杂的观测模式特点,又为了解决地震野外监测的低成本、高效传输、快速部署的台阵组网难题,以LoRa为主要通讯网络,结合Wifi和ZigBee无线网络技术,设计实现一种便携式、低功耗、快速组网的无线复合通讯网关。实验测试表明,该网关在LoRa组网下可以实现2 km范围内最高21 kbps空中传输速率的网络通讯状态,适用于地震野外监测高效传输、快速部署的台阵组网。  相似文献   

18.
AGalerkin finite-element model coupled with a particle tracking routine was developed to analyze the flow and transport dynamics near a high-capacity irrigation well. The model was used to compute the head distribution around the pumping well, to determine the area of influence, and to define ground water flowlines during short-term pumping periods typical of those used to collect water quality samples from high-capacity wells. In addition to hypothetical example results, the model was used to qualitatively analyze data obtained from pump-and-sample experiments conducted in an unconfined alluvial aquifer within the Platte River valley of south-central Nebraska where nitrate-nitrogen (NO3-N) contamination is prevalent.
Simulation results of both the hypothetical and field cases suggest that short-term pumping events, impact a limited volume of aquifer. The area of influence and flowlines are affected by aquifer anisotropy, pumping rate, and well construction characteristics). Ground water above or below the screened intervals does not enter a partially penetrating well in anisotropic aquifers. In aquifers where NO3-N concentration varies vertically and horizontally, waler quality samples from an irrigation, or other high-capacity, well provide only limited information about ground water contamination. A numerical model is thus recommended for calculating the area of influence and determining flowlines around high-capacity wells so that information derived from water quality samples collected at the wellhead can be better interpreted.  相似文献   

19.
An advanced two-way radio link (transceiver units) and data logging system have provided a powerful means of real-time series data collection and analysis. The application of this telemetry system to surface tiltmeter surveys provides significant cost savings for testing and analysis of deep, large-scale horizontal anisotropic permeability and heterogeneity determinations.
The determination of horizontal anisotropic properties requires one pumping well and eight to 10 tiltmeter monitoring stations. The validity of the depth of the test may reach 4,000 feet below land surface. With the addition of one partially penetrating observation well, the entire three-dimensional anisotropic permeability can be determined. With the addition of a fully penetrating well, the storage coefficient can be determined as well as leakage property (including vertical permeability of the confining layers). An example test case was analyzed for horizontal anisotropic permeability with remarkable success despite relatively unfavorable detection conditions.
A thorough understanding of the geology overlying the aquifer system must be made in order to assess the applicability of the surface tiltmeter survey to large-scale horizontal anisotropic permeability determinations.  相似文献   

20.
Artificial neural networks (ANNs) were developed to accurately predict highly time-variable specific conductance values in an unconfined coastal aquifer. Conductance values in the fresh water lens aquifer change in response to vertical displacements of the brackish zone and fresh water-salt water interface, which are caused by variable pumping and climate conditions. Unlike physical-based models, which require hydrologic parameter inputs, such as horizontal and vertical hydraulic conductivities, porosity, and fluid densities, ANNs can "learn" system behavior from easily measurable variables. In this study, the ANN input predictor variables were initial conductance, total precipitation, mean daily temperature, and total pumping extraction. The ANNs were used to predict salinity (specific conductance) at a single monitoring well located near a high-capacity municipal-supply well over time periods ranging from 30 d to several years. Model accuracy was compared against both measured/interpolated values and predictions were made with linear regression, and in general, excellent prediction accuracy was achieved. For example, although the average percent change of conductance over 90-d periods was 39%, the absolute mean prediction error achieved with the ANN was only 1.1%. The ANNs were also used to conduct a sensitivity analysis that quantified the importance of each of the four predictor variables on final conductance values, providing valuable insights into the dynamics of the system. The results demonstrate that the ANN technology can serve as a powerful and accurate prediction and management tool, minimizing degradation of ground water quality to the extent possible by identifying appropriate pumping policies under variable and/or changing climate conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号