首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
将结构物简化为多质点体系,考虑隔震支座的水平刚度、垂直刚度和转动刚度,按反应谱方法进行了高层剪力墙结构和砖结构抗震计算,结果表明,隔震结构可以大幅度地降低地震作用。  相似文献   

2.
The distribution of seismic base shear demand among ductile flexural cantilever walls, comprising the lateral load resisting system of a multistorey building, is studied. It is shown that the base shear force demand depends on the sequence of hinge formation at the wall bases, and this in turn depends on the relative wall lengths. Hence, the routine elastic approach in which the shear forces are allocated per relative flexural rigidity or (when some consideration is given to plastic hinge formation) to moment capacity at the wall base, may appreciably underestimate the shear force demand on the walls, particularly the shorter (usually the more flexible) ones. A simple procedure yielding the results of ‘cyclic’ pushover analysis is proposed to predict the peak seismic wall forces for a given total base shear when plastification is confined to the wall base. The effects of plastic hinges developing at higher floors on (1) shear distribution among the walls and (2) the in‐plane floor forces are also considered. Two numerical examples are presented to demonstrate the main points made. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

3.
Different modelling aspects of structures isolated using the frictional pendulum system and subjected to earthquake ground motions are studied herein. Although the vertical dynamics of these structures is given special emphasis, other effects such as large isolator deformations and bidirectional input motion are also considered. Different structural models of the FPS are developed and tested for single-storey structures and a real four-storey building frame; among them, an ‘exact’ formulation of the FPS force–deformation constitutive relationship is presented. Results show that global building responses can be computed within 20 per cent error in the mean using a simplified model that ignores the vertical motion of the building; however, structural member deformations and forces need to be computed using a model that considers such motion. This is of particular importance when there exist correlation between the horizontal and vertical components of ground motion. Further, a physical model of the FPS is introduced and used to determine the response of a real four-storey frame, including uplift and downward impact. Results from this analysis show that local column responses may vary substantially depending on the stiffness of the isolation storey and the presence of a mass at the isolation level. Such mass is capable of filtering the large increase in column shear that results from the impact of the structure after uplift. Uplift occurs at several instants of the response of the structure considered, leading to an increase in column base shear as large as 3 times the shear obtained by ignoring the vertical dynamics of the building. © 1998 John Wiley & Sons, Ltd.  相似文献   

4.
Numerical simulations and parametric studies have been used to investigate the influence of potential poundings of seismically isolated buildings with adjacent structures on the effectiveness of seismic isolation. Poundings are assumed to occur at the isolation level between the seismically isolated building and the surrounding moat wall. After assessing some common force‐based impact models, a variation of the linear viscoelastic impact model is proposed to avoid tensile impact forces during detachment, while enabling the consideration of permanent plastic deformations at the vicinity of the impact. A large number of numerical simulations of seismically isolated buildings with different characteristics have been conducted under six earthquake excitations in order to investigate the influence of various design parameters and conditions on the peak floor accelerations and interstorey deflections during poundings. The numerical simulations demonstrate that poundings may substantially increase floor accelerations, especially t the base floor where impacts occur. Higher modes of vibration are excided during poundings, increasing the interstorey deflections, instead of retaining an almost rigid‐body motion of the superstructure, which is aimed with seismic isolation. Impact stiffness seems to affect significantly the acceleration response at the isolation level, while the displacement response is more insensitive to the variation of the impact stiffness. Finally, the results indicate that providing excessive flexibility at the isolation system to minimize the floor accelerations may lead to a building vulnerable to poundings, if the available seismic gap is limited. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

5.
Main purpose of this study is to evaluate the dynamic behavior of fluid–rectangular tank–soil/foundation system with a simple and fast seismic analysis procedure. In this procedure, interaction effects are presented by Housner's two mass approximations for fluid and the cone model for soil/foundation system. This approach can determine; displacement at the height of the impulsive mass, the sloshing displacement and base forces for the soil/foundation system conditions including embedment and incompressible soil cases. Models and equations for proposed method were briefly explained for different tank–soil/foundation system combinations. By means of changing soil/foundation conditions, some comparisons are made on base forces and sloshing responses for the cases of embedment and no embedment. The results showed that the displacements and base shear forces generally decreased, with decreasing soil stiffness. However, embedment, wall flexibility, and soil–structure interaction (SSI) did not considerably affect the sloshing displacement.  相似文献   

6.
This paper describes an analytical investigation on a reinforced concrete lateral load resisting structural system comprising a pin‐supported (base‐rocking) shear wall coupled with a moment frame on 1 or both sides of the wall. Yielding dampers are used to provide supplemental energy dissipation through the relative displacements at the vertical connections between the wall and the frames. The study extends a previous linear‐elastic model for pin‐supported wall‐frame structures by including the effects of the dampers. A closed‐form solution of the lateral load behavior of the structure is derived by approximating the discrete wall‐frame‐damper interactions with distributed (ie, continuous) properties. The validity of the model is verified by comparing the closed‐form results with computational models using OpenSees program. Then, a parametric analysis is conducted to investigate the effects of the wall, frame, and damper stiffness on the behavior of the structure. It is found that the damper stiffness significantly affects the distribution of shear forces and bending moments over the wall height. Finally, the performance‐based plastic design approach extended to the wall‐frame‐damper system is proposed. Case studies are carried out to design 2 damped pin‐supported wall‐frame structures using the proposed approach. Nonlinear dynamic time‐history analyses are conducted to verify the effectiveness of this method. Results indicate that the designed structures can achieve the performance level with the story drift ratios less than target values, and weak‐story failure mechanism is not observed. The approach can be used in engineering applications.  相似文献   

7.
Prediction of the seismic rotational displacements of retaining wall under passive condition is an important aspect of design in earthquake prone region. In this paper, the pseudo-dynamic method is used to compute the rotational displacements of rigid retaining wall supporting cohesionless backfill under seismic loading for the passive earth pressure condition. The proposed method considers time, phase difference and effect of amplification in shear and primary waves propagating through both the backfill and the retaining wall. The influence of ground motion characteristics on rotational displacement of the wall is evaluated. Also the effects of variation of parameters like wall friction angle, soil friction angle, amplification factor, shear wave velocity, primary wave velocity, period of lateral shaking, horizontal and vertical seismic accelerations on the rotational displacements are studied. The rotational displacement of the wall increases substantially with increase in amplification of both shear and primary waves, time of input motion, period of lateral shaking and decreases with increase in soil friction angle, wall friction angle. The rotational displacements of the wall also increase when the effect of wall inertia is taken into account. Results are provided in graphical form.  相似文献   

8.
The evaluation of the fundamental period of shear wall buildings considering the flexibility of the base is investigated in this paper. This research is motivated by the discrepancy reported between the formulas used in different building codes and the measurement of real buildings. Both experimental and analytical approaches are used to assess the effect of the base flexibility on the fundamental period of shear wall structures. In total, twenty buildings built on different types of soil are tested under ambient vibration. The fundamental period is identified using a non‐parametric linear model in the frequency domain. The results show that fundamental period formulas used by UBC‐97 and NBCC‐95 are inadequate since they do not include the effect of the foundation stiffness. To improve the estimation of the fundamental period of shear wall buildings, an analytical approach is presented. The structure and the foundation are represented by a continuous‐discrete system. The stiffnesses of the base are represented by translational and rotational discrete springs. The rigidities of these springs are evaluated from the elastic uniform compression of the soil mass and the size of the foundation. The analytical predictions improve the estimation of the fundamental period and keep the computation simple. The error between the measured period and the analytical results is, on average, less than 10%. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

9.
双向单排配筋混凝土低矮剪力墙抗震性能试验研究   总被引:6,自引:2,他引:4  
双向单排配筋混凝土低矮剪力墙适用于多层住宅结构。对4个原型的剪跨比为1.0配筋混凝土低矮剪力墙进行了低周反复荷载试验研究,包括1个双向双排配筋混凝土低矮剪力墙和3个双向单排配筋混凝土低矮剪力墙。其中1个双向单排配筋混凝土低矮剪力墙加设暗支撑,用以研究暗支撑对这种新型墙体的作用。在试验研究的基础上,对比分析了各剪力墙的刚度及其衰减过程、承载力、延性、滞回特征、耗能能力及破坏特征。试验表明,经过合理设计,这种双向单排配筋混凝土低矮剪力墙可以满足多层住宅结构抗震要求。  相似文献   

10.
A shear building supported by a prescribed pile–soil system is subjected to bedrock earthquake input. A new design procedure is presented for generating a sequence of stiffness designs satisfying the constraints on interstorey drifts. The mean peak interstorey drifts of the shear building subjected to a set of spectrum-compatible ground motions at the bedrock are evaluated by a modal combination rule. Tuning of the fundamental natural period of a shear building with a fixed base with that of a shear beam ground results in a non-monotonic sequence of stiffness designs with respect to a ground stiffness parameter and previous approaches cannot be applied to such a problem. This difficulty in finding such a non-monotonic sequence is overcome by utilizing the ground stiffness parameter and the superstructure stiffness parameter alternately in multiple design phases and by developing a new multi-phase perturbation technique. Fundamental characteristics of this sequence of stiffness designs and the effect of ground stiffnesses on the design of the shear building are disclosed. It is further shown that the stiffness contour method is also useful for the design procedure such that a scattering effect in the estimates of ground stiffnesses is taken into account. The usefulness of the proposed procedure of sequential stiffness design and contour line method is demonstrated through several sequential design examples.  相似文献   

11.
A modified energy-balance equation accounting for P-delta effects and hysteretic behavior of reinforced concrete members is derived. Reduced hysteretic properties of structural components due to combined stiffness and strength degradation and pinching effects, and hysteretic damping are taken into account in a simple manner by utilizing plastic energy and seismic input energy modification factors. Having a pre-selected yield mechanism, energy balance of structure in inelastic range is considered. P-delta effects are included in derived equation by adding the external work of gravity loads to the work of equivalent inertia forces and equating the total external work to the modified plastic energy. Earthquake energy input to multi degree of freedom (MDOF) system is approximated by using the modal energy-decomposition. Energy-based base shear coefficients are verified by means of both pushover analysis and nonlinear time history (NLTH) analysis of several RC frames having different number of stories. NLTH analyses of frames are performed by using the time histories of ten scaled ground motions compatible with elastic design acceleration spectrum and fulfilling duration/amplitude related requirements of Turkish Seismic Design Code. The observed correlation between energy-based base shear force coefficients and the average base shear force coefficients of NLTH analyses provides a reasonable confidence in estimation of nonlinear base shear force capacity of frames by using the derived equation.  相似文献   

12.
13.
Previous research has demonstrated that uplifting-column or rocking building systems may exhibit improved seismic performance, including reductions in total base shear and decreased residual drift, when compared with systems rigidly connected to the foundation. These beneficial effects may be due to lengthened periods, activation of rocking modes, and energy dissipation of base fuse elements. In the current work, several configurations of a miniature steel building with different combinations of base connection and traditional superstructure fuse strength and stiffness were subjected to identical earthquake motions to evaluate differences in demands and performance. The uplifting base connections incorporate highly ductile concrete anchors with long stretch lengths, allowing robust connection performance and easy replacement of damaged connection elements following the seismic event, an advantage over previously tested systems. Testing and dynamic numerical analysis indicates that ductile anchor uplifting systems may reduce total base shear by over 20%, as well as reducing residual structural drift by more than 80%.  相似文献   

14.
This paper examines the dynamic implications of connecting closely neighbouring structures for the purpose of eliminating pounding during earthquakes. To prevent this destructive contact the structures are connected by a link and beam system which transmits the connection forces to the floors of the structures. Four specific cases are used as examples of the effects. The coupled system is modelled as a combined mass and stiffness matrix problem which allows the traditional methods for analysis. The mode shapes and natural frequencies for these cases are examined, and it is shown that the general response characteristics can be derived from the coupled system's frequencies and modes. Estimates of the fundamental frequency of the coupled system are derived. Both the harmonic and earthquake response are examined for the four cases. In all circumstances the linkage reduces the relative overlap deflection of the structures at large amplitudes, but it also increases the base shear on the stiffer of the two structures at excitation frequencies below the fundamental frequency. It is shown that bounds on the base shear are derivable from the change in the fundamental frequencies. The dependence of the response characteristics on the stiffness of the coupling beam is also examined.  相似文献   

15.
填充墙具有显著的刚度和承载力贡献。建筑结构震害调查发现,不开洞横墙的破坏程度远小于开洞纵墙的破坏程度,从宏观现象可判断大部分多层建筑的破坏主要由结构纵向运动造成。为研究横墙在地震作用下的性能及其对结构整体动力响应的影响,以经受2021年5月21日云南漾濞6.4级地震震害的花椒园小学教学楼为研究对象,按当地抗震计算参数进行弹塑性时程分析。采用等效斜压杆模拟横向填充墙,设置无填充墙框架结构、带黏土砖墙的框架结构、带空心砖墙的框架结构和带加气混凝土砌块填充墙的框架结构模型,选取10组地震波横向输入。研究结果表明,4种结构自振周期均处于具有统计学意义的平台段,平均加速度响应较接近,质量和刚度变化不会使结构加速度产生规律的变化;受结构自重影响,无填充墙的框架结构底部剪力小于带填充墙的框架结构,带填充墙的框架结构位移远小于无填充墙的框架结构;带有多道不开洞横墙的多层框架结构的破坏主要是由结构纵向破坏引起的。  相似文献   

16.
钢框架-带缝钢板剪力墙结构受力性能分析   总被引:1,自引:0,他引:1  
本文对4种钢框架、6种带缝(两排)钢板剪力墙片(四周与构件无连接)和6种固接的钢框架-带缝钢板剪力墙结构在3种不同竖向荷载作用下的抗侧能力和往复荷载下的滞回性能进行了研究,并对比分析。结果表明:前两种结构的侧移刚度、抗侧能力相对较低,屈曲后刚度退化快;钢框架-带缝钢板剪力墙结构的侧移刚度、抗侧能力和耗能能力比前两种结构有明显的提高,说明钢框架与带缝钢板剪力墙片固接后工作协调性能良好。带缝钢板剪力墙片与钢框架-带缝钢板剪力墙结构的整体设计参数宽高比W/H,开缝设计参数开缝墙肢的高宽比h/b、宽厚比b/t、开缝墙肢与剪力墙的高宽比h/H对结构的抗侧能力和滞回性能有很大影响。W/H增大,结构的抗侧能力增强,滞回性能降低;h/b、b/t、h/H增大,结构的抗侧能力降低,滞回性能提高。  相似文献   

17.
A simple method for the non-linear static analysis of complex building structures subjected to monotonically increasing horizontal loading (push-over analysis) is presented. The method is designed to be a part of new methodologies for the seismic design and evaluation of structures. It is based on the extension of a pseudo-three-dimensional mathematical model of a building structure into the non-linear range. The structure consists of planar macroelements. For each planar macroelement, a simple bilinear or multilinear base shear–top displacement relationship is assumed. By a step-by-step analysis an approximate relationship between the global base shear and top displacement is computed. During the analysis the development of plastic hinges throughout the building can be monitored. The method has been implemented into a prototype computer program. In the paper the mathematical model, the base shear–top displacement relationships for different types of macroelements, and the step-by-step computational procedure are described. The method has been applied for the analysis of a symmetric and an asymmetric variant of a seven-storey reinforced concrete frame–wall building, as well as for the analysis of a complex asymmetric 21-storey reinforced concrete wall building. The influence of torsion on structural behaviour is discussed. © 1997 by John Wiley & Sons, Ltd.  相似文献   

18.
Base isolation requires a gap between the base-isolated building and its surroundings to provide space for the deformation of isolation system. Bumping against the surroundings may change the performance of the base-isolated building. In this study, the building is modelled as an elastic or inelastic shear beam and the surroundings is simplified as elastic or inelastic stops. The influence of stop stiffness, gap size and stop strength on the seismic response is studied. Numerical results indicate that the impact wave induced by the bumping can create an extremely high acceleration response in the shear beam, if the shear beam remains elastic. A non-linearly elastic stop model is observed to reduce the acceleration response. If the shear beam yields, the impact wave cannot propagate through the shear beam and the shear beam remains in the low acceleration response except for the base. Changing the stop stiffness or stop strength has little effect on the distribution of ductility demand along the shear beam. © 1997 by John Wiley & Sons, Ltd.  相似文献   

19.
The mid‐story isolation design method is recently gaining popularity for the seismic protective design of buildings located in the areas of high population. In a mid‐story isolated building, the isolation system is incorporated into the mid‐story rather than the base of the building. In this paper, the dynamic characteristics and seismic responses of mid‐story isolated buildings are investigated using a simplified three‐lumped‐mass structural model for which equivalent linear properties are formulated. From the parametric study, it is found that the nominal frequencies of the superstructure and the substructure, respectively, above and below the isolation system have significant influences on the isolation frequency and equivalent damping ratio of a mid‐story isolated building. Moreover, the mass and stiffness of the substructure are of greater significance than the superstructure in affecting the dynamic characteristics of the isolated building. Besides, based on the response spectrum analysis, it is noted that the higher mode responses may contribute significantly to the story shear force of the substructure. Consequently, the equivalent lateral force procedure of design codes should carefully include the effects of higher modes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
多层钢结构基础隔震性能研究   总被引:1,自引:0,他引:1  
本文用算例按基底剪力法,振型反应谱法和时程分析法分析了多层基础隔震钢结构和多层钢筋混凝土结构及其对应的非隔震结构的地震力和层间剪力。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号