共查询到20条相似文献,搜索用时 15 毫秒
1.
The Balloon Intercomparison Campaigns of 1982 and 1983 compared balloon-borne sensors of HCl, HNO3, NO2, NO and O3, and measured many other stratospheric constituents. Most sensors were remote rather than in-situ. In the 1982 campaign, three large gondolas were successfully launched from Palestine, Texas on the same day; in the 1983 campaign, four gondolas were launched within 3 days. Accompanying papers describe the results of these successful intercomparisons. 相似文献
2.
H. K. Roscoe B. J. Kerridge S. Pollitt N. Louisnard J. M. Flaud C. Camy-Peyret C. Alamichel J-P. Pommereau T. Ogawa N. Iwagami M. T. Coffey W. Mankin W. F. J. Evans C. T. McElroy J. Kerr 《Journal of Atmospheric Chemistry》1990,10(2):111-144
During the 1982 and 1983 Balloon Intercomparison Campaigns, the vertical profile of stratospheric NO2 was measured remotely by nine instruments and that of NO by two. Total overhead columns were measured by two more instruments. Between 30 and 35km, where measurements overlapped, agreement between NO profiles was within ±30%, which is better than the accuracies claimed by the experimenters. Between 35 and 40km there was similarly good agreement between NO2 profiles, but below 30km, differences of greater than a factor three were found. In the second Campaign, NO2 values from most instruments agreed within their quoted errors, except that the Oxford radiometer gave much lower values; but the first Campaign and the column measurements show a more uniform spread of results.These differences below 30km could not be resolved, but new laboratory measurements are planned which should do so. 相似文献
3.
When all balloon-borne measurements of NO2 in the stratosphere are reviewed, the profiles show a wide spread. Measurements of the total amount in a vertical column suggest that variability should be low when only profiles measured at mid-latitudes close to equinox are selected. With this selection, the standard deviation of the profiles measured by each technique is often less than ±20%, but the mean profiles measured by each technique differ by up to a factor 2. Despite the profiles not being measured simultaneously, these differences are identical to those revealed by the simultaneous measurements of the Balloon Intercomparison Campaigns of 1982 and 1983-a comparison can be made from the historic data alone. This suggests that measurements of other gases should be similarly reviewed and appropriate selection criteria be found that reduces the standard deviations of the measurements by any one technique. The techniques can then be intercompared without new simultaneous flights. 相似文献
4.
Following the Balloon Intercomparison Campaigns carried out from the NSBF, Palestine, Texas, in the fall of 1982 (BIC1) and spring of 1983 (BIC2), three instruments have reported infrared measurements (one in emission and two in absorption) from which results on the concentration of methane between 20 and 40 km altitude have been deduced. While the absorption-retrieved concentration profiles are in excellent agreement, the results from the emission measurements are significantly lower. Recent methane profiles obtained by satellite and from Spacelab 1 are in satisfactory agreement with the absorption data reported here. 相似文献
5.
D. Murcray A. Goldman J. Kosters R. Zander W. Evans N. Louisnard C. Alamichel M. Bangham S. Pollitt B. Carli B. Dinelli S. Piccioli A. Volboni W. Traub K. Chance 《Journal of Atmospheric Chemistry》1990,10(2):159-179
The Balloon Intercomparison Campaign (BIC) was set up to intercompare remote sensing measurements of a number of compounds other than water vapor; however, water vapor has strong absorption features throughout the infrared and mm wave regions of the spectrum. Therefore many of the investigators involved in BIC have absorption or emission features due to water vapor in the data they obtained during the balloon flights made under the campaign. These features have been used by the investigators to determine the stratospheric water vapor profiles which are compared in this paper. The profiles allow comparison of a wide range of remote sensing techniques involving both emission and absorption in the mid-infrared and emission techniques in the far infrared. 相似文献
6.
William G. Mankin M. T. Coffey K. V. Chance W. A. Traub B. Carli F. Mencaraglia S. Piccioli I. G. Nolt J. V. Radostitz R. Zander G. Roland Douglas W. Johnson Gerald M. Stokes C. B. Farmer R. K. Seals 《Journal of Atmospheric Chemistry》1990,10(2):219-236
Observations of the vertical profile of hydrogen fluoride (HF) vapor in the stratosphere and of the vertical column amounts of HF above certain altitudes were made using a variety of spectroscopic instruments in the 1982 and 1983 Balloon Intercomparison Campaigns. Both emission instruments working in the far infrared spectral region and absorption instruments using solar occultation in the 2.5m region were employed. No systematic differences were seen in results from the two spectral regions. A mean profile from 20–45 km is presented, with uncertainties ranging from 20% to 50%. Total columns measured from ground and from 12 km are consistent with the profile if the mixing ratio for HF is small in the tropophere and low stratosphere. 相似文献
7.
大气臭氧与气溶胶垂直分布的高空气球探测 总被引:17,自引:2,他引:17
本文给出了1993年9月12日利用高空科学气球在河北省香河地区探测到的大气臭氧和气溶胶的垂直分布。结果发现:(1) 大气臭氧的数密度在整个对流层较低(~10[12]mol/cm3),并从地面到对流层顶略有下降;对流层顶以上开始快速增加,极值层高度在~24 km,其值为4.78×10[12]mol/cm3;臭氧分压有类似的分布特征,极值146×10[-4]Pa,位于同一高度;(2) 在平流层低层,臭氧分压有一个次极值62×10[-4]Pa,位于15~16 km;(3) 0~30 km大气气溶胶数密度呈现出三个峰值:143,8和1.1 个/cm[3],分别位于近地面、5 km和21 km;(4)气溶胶的数密度谱在对流层为双模态;在平流层,次峰消失。同时,我们还与其他观测结果作了比较分析。 相似文献
8.
A. Hofzumahaus U. Aschmutat U. Brandenburger T. Brauers H.-P. Dorn M. Hausmann M. Heßling F. Holland C. Plass-Dülmer D. H. Ehhalt 《Journal of Atmospheric Chemistry》1998,31(1-2):227-246
In-situ OH measurements by laser-induced fluorescence (LIF) spectroscopy and folded long-path differential optical absorption spectroscopy (DOAS) were carried out in a rural environment in North-East Germany as part of the field experiment POPCORN in August 1994. The large set of OH data obtained allowed an intercomparison of both techniques based on relative diurnal profiles and simultaneously measured absolute concentrations. Most of the time the two OH instruments encountered the same air and agreed well in the measured relative diurnal variations. Only on a few occasions the measurements significantly disagreed due to a perturbation of the DOAS measurements by a local OH source in the north-western wind sector. Excluding data from this wind direction, the statistical analysis of 137 data pairs yields a correlation coefficient of r = 0.90 and a weighted linear fit with a slope of 1.09 ± 0.12. The correlations are carefully analyzed. The comparison of both instruments is discussed in the light of newly published effective absorption cross-sections for H2O and O2 that affect the calibration of LIF. 相似文献
9.
R. L. McKenzie W. A. Matthews Y. Kondo R. Zander Ph. Demoulin P. Fabian D. G. Murcray F. J. Murcray O. Lado-Bordowsky C. Camy-Peyret H. K. Roscoe J. A. Pyle R. D. McPeters 《Journal of Atmospheric Chemistry》1988,7(4):353-367
Column measurements of nitric oxide were made using several techniques during the MAP/GLOBUS campaign in France in September 1985. The data sets are nearly co-located and simultaneous, therefore allowing a valid intercomparison of the various measurement methods. The range of altitudes sampled differs from instrument to instrument. This complicates the comparison because the data sets are to some extent complementary. The NO distributions apparently vary significantly from day to day, and possibly over shorter timescales. Changes in dynamics may be responsible for these variations. The results from the instruments which measure in the infrared and the ultraviolet are self-consistent, and show good agreement with photochemical predictions. On 19 September, when the intercomparison was made, the profile measured by the in-situ chemiluminescent instrument differed significantly from the predicted profile, and the measured columns were generally higher. 相似文献
10.
C. B. Farmer B. Carli A. Bonetti M. Carlotti B. M. Dinelli H. Fast W. F. J. Evans N. Louisnard C. Alamichel W. Mankin M. Coffey I. G. Nolt D. G. Murcray A. Goldman G. M. Stokes D. W. Johnson W. A. Traub K. V. Chance R. Zander G. Roland L. Delbouille 《Journal of Atmospheric Chemistry》1990,10(2):237-272
All of the techniques used to measure stratospheric HCl during the two BIC campaigns involved high resolution infrared spectroscopy. The balloon-borne instruments included five different spectrometers, three operating in the solar absorption mode and two in emission (at distinctly different wavelengths). Ground-based and aircraft correlative measurements were made close to the balloon locations, again by near-infrared spectroscopy.Within this set of results, comparisons between different techniques (absorption vs emission) viewing the same airmass (i.e., on the same gondola) were possible, as were comparisons between the same technique used on different gondolas spaced closely in time and location. The final results yield a mean profile of concentration of HC1 between 18 and 40 km altitude; an envelope of ±15% centered on this profile encompasses all of the results within one standard deviation of their individual mean values. The absolute accuracy of the final profile is estimated to be no worse than 10%. It is concluded also that the measurement techniques for HCl have reached a level of performance where a precision of 10% to 15% can be confidently expected. 相似文献
11.
介绍了国际大气环流模式比较计划(AMIP)的概况,它的分析子计划及执行情况、科学进展、相关计划及未来发展等情况,以便国内学者了解并积极参与该研究计划。 相似文献
12.
Large Aperture Scintillometer Intercomparison Study 总被引:2,自引:2,他引:2
J. Kleissl J. Gomez S.-H. Hong J. M. H. Hendrickx T. Rahn W. L. Defoor 《Boundary-Layer Meteorology》2008,128(1):133-150
Two field studies with six large aperture scintillometers (LASs) were performed using horizontal and slant paths. The accuracy
of this novel and increasingly popular technique for measuring sensible heat fluxes was quantified by comparing measurements
from different instruments over nearly identical transects. Random errors in LAS measurements were small, since correlation
coefficients between adjacent measurements were greater than 0.995. However, for an ideal set-up differences in linear regression
slopes of up to 21% were observed with typical inter-instrument differences of 6%. Differences of 10% are typical in more
realistic measurement scenarios over homogeneous natural vegetation and different transect heights and locations. Inaccuracies
in the optics, which affect the effective aperture diameter, are the most likely explanation for the observed differences. 相似文献
13.
We present characterizations of the dynamic turbulence in the lower stratosphere measured by a new balloon-based system designed for detecting finer scale dynamic turbulence. The balloon-based system included a constant temperature anemometer(CTA) operating at a sampling rate of 2 k Hz at an ascent speed of 5 m s-1(corresponding to a vertical resolution of 2.5 mm), an industrial personal computer, batteries, sensors for ambient temperature and humidity, an A/D converter, and others. The system was successfully launched to 24 km altitude over Bayannur City, Inner Mongolia Province. Results show the spatial intermittence of the turbulence layers, with clear boundaries between turbulent and nonturbulent regions. This is the first time that the dynamic turbulence spectrum down to the viscous sub-range has been obtained throughout the lower stratosphere over China. With that, the energy dissipation rates of dynamic turbulence could be calculated with high precision. The profile of the dissipation rates varied from 7.37 × 10-7 to 4.23 W kg-1 and increased with altitude in the stratosphere. 相似文献
14.
R. Toumi 《Journal of Atmospheric Chemistry》1992,15(1):69-77
The possibility of significant autocatalytic ozone production in the middle atmosphere has been demonstrated by Toumi et al. A detailed framework including five processes previously not considered is presented here. When these processes are included, particularly wavelength-dependent vibrational distributions of O2, calculated ozone enhancements are less than 10% in the upper stratosphere and lower mesosphere. The vibrational distributions and the rate of vibrational quenching are identified as key issues which need to be addressed by experiments. 相似文献
15.
多种土壤湿度资料在中国地区的对比分析 总被引:1,自引:0,他引:1
利用1992—2012年中国区域土壤湿度观测资料对目前使用较为广泛的5套土壤湿度资料(ERA-Interim、NCEP再分析资料、GLDAS同化资料、CPC模式资料和AMSR-E卫星反演资料)的适用性进行检验,分析5套资料对中国区域土壤湿度的时空分布特征和变化趋势的描述能力。结果表明:5套资料都能大体反映暖季中国区域土壤湿度东南湿、西北干,自东南向西北递减的分布格局以及西北干旱区和半干旱区变湿、长江流域部分地方变干的变化趋势,其中CPC资料最接近观测事实,并能较好地表现局地特征;在描述土壤湿度的季节变化和年际变化方面,GLDAS和NCEP资料与观测数据的相关性较好,能较好反映土壤湿度的时间演变特征。进一步利用检验效果较好的GLDAS、NCEP和CPC资料分别对中国区域土壤湿度时间和空间的长期变化趋势分析发现:中国区域标准化年平均土壤湿度在1948—1996年处在相对湿润期,而1996—2012年处在相对干旱期;中国区域年平均土壤湿度的空间变化特征是东部变干、西部变湿,自东北、华北至西南呈现一个干旱化带。 相似文献
16.
亚洲区域气候模式比较计划的进展 总被引:20,自引:2,他引:20
区域气候变化的信息是气候变化影响评估的基础。在发展全球气候模式的同时 ,发展高分辨的区域气候模式是获取区域气候变化信息的重要途径之一。作者介绍了由中国科学院大气物理研究所START全球变化东亚区域研究中心发起和主持 ,有中、美、韩、日和澳大利亚 1 0个研究组参加的亚洲区域气候模式比较计划的目的、意义、工作任务和试验设计等主要内容 ,给出了该国际比较计划第 1阶段 (连续 1 8个月积分 )和第 2阶段( 1 988~ 1 998年连续 1 0年积分 )的初步结果 ,讨论了区域气候模式在亚洲应用中的一些共性问题以及进一步研究的方向。 相似文献
17.
Eric Schlosser Birger Bohn Theo Brauers Hans-Peter Dorn Hendrik Fuchs Rolf Häseler Andreas Hofzumahaus Frank Holland Franz Rohrer Lutz Olaf Rupp Manfred Siese Ralf Tillmann Andreas Wahner 《Journal of Atmospheric Chemistry》2007,56(2):187-205
At the atmosphere simulation chamber SAPHIR in Jülich both Laser-Induced Fluorescence Spectroscopy (LIF) and Long-Path Differential
Optical Laser Absorption Spectroscopy (DOAS) are operational for the detection of OH radicals at tropospheric levels. The
two different spectroscopic techniques were compared within the controlled environment of SAPHIR based on all simultaneous
measurements acquired in 2003 (13 days). Hydroxyl radicals were scavenged by added CO during four of these days in order to
experimentally check the calculated precisions at the detection limit. LIF measurements have a higher precision (σ= 0.88×106 cm–3) and better time resolution (Δt = 60 s), but the DOAS method (σ= 1.24×106 cm–3, Δt = 135 s) is regarded as primary standard for comparisons because of its good accuracy. A high correlation coefficient of
r = 0.95 was found for the whole data set highlighting the advantage of using a simulation chamber. The data set consists of
two groups. The first one includes 3 days, where the LIF measurements yield (1 – 2) ×106 cm–3 higher OH concentrations than observed by the DOAS instrument. The experimental conditions during these days are characterized
by increased NOx concentration and a small dynamic range in OH. Excellent agreement is found within the other group of 6 days. The regression
to the combined data of this large group yields unity slope without a significant offset. 相似文献
18.
19.
C. Camy-Peyret B. Bergovist B. Galle M. Carleer C. Clerbaux R. Colin C. Fayt F. Goutail M. Nunes-Pinharanda J. P. Pommereau M. Hausmann U. Platt I. Pundt T. Rudolph C. Hermans P. C. Simon A. C. Vandaele J. M. C. Plane N. Smith 《Journal of Atmospheric Chemistry》1996,23(1):51-80
The results of an intercomparison campaign of eight different long path UV-visible DOAS instruments measuring NO2, O3 and SO2 concentrations in a moderately polluted urban site are presented. For effective optical path lengths of 230 and 780 m the overall spread of these measurements (±1) are 5×1010, 6×1010 and 1×1010 molec·cm-3 (2.0, 2.4, and 0.4 ppb) for these molecules respectively when all instruments used a common set of absorption cross sections. The remaining differences are not completely random and the systematic differences are attributed to the different retrieval methods used for each instrument. 相似文献
20.
NCEP再分析资料和中国站点观测资料的分析与比较 总被引:37,自引:7,他引:37
美国国家环境预报中心(NCEP)和国家大气中心(NCAR)的全球再分析资料,在很多气候模拟和预测研究中都被作为区域气候模式的驱动场和初始场资料,并用来检验模拟结果的.作者通过对NCEP的2种再分析资料NCEPI和NCEPⅡ与中国台站观测资料的月平均温度和月降水总量进行相互插值,分析和比较了NCEPⅠ、NCEPⅡ再分析值与中国区域内观测值之间的差异以及2种再分析资料之间的差异.从结果可以看到,NCEP再分析资料的月平均温度较观测值普遍偏低,而月降水总量较观测值则偏高;就季节变化而言,NCEP再分析值在夏季和年平均模拟的较好,冬季较差.同时可以看到,在温度和降水方面NCEPⅡ较NCEPⅠ都有所改进,尤其在中国东部地区,改进较为明显. 相似文献