首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
In recent papers the author has shown that when determining optimum parameters for an absorber which minimizes the vibration response of a complex system, the latter may be treated as an equivalent single degree-of-freedom system if its natural frequencies are well separated. Emphasis was on minimizing the displacement response when the excitation was a harmonic force. In the present paper simple expressions for optimum absorber parameters are derived for undamped one degree-of-freedom main systems for harmonic and white noise random excitations with force and frame acceleration as input and minimization of various response parameters. These expressions can be used to obtain optimum parameters for absorbers attached to complex systems provided that optimization is with respect to an absolute, rather than a relative, quantity. The requirement that the natural frequencies should be well separated is investigated numerically for the different cases. The effect of damping in the main system on optimum absorber parameters is investigated also.  相似文献   

2.
The equations of motion are derived for the first mode response of a linear multistorey structure having a linear vibration absorber attached to the roof. Furthermore, the variance of the first mode response to a gaussian white noise lateral base acceleration (as a model of earthquake excitation) is determined. Smallest possible values of the variance of the response along with corresponding absorber parameters are established using an optimization program. It is demonstrated that the absorber is quite effective in reducing first mode response for 5- and 10-storey structures even with relatively small values of the absorber mass. Moreover, minimal responses for the randomly excited single-degree-of-freedom system have been determined, and a design example is presented. The absorber system has potential application not only in earthquake engineering but also in aerospace and terrestrial vehicle design.  相似文献   

3.
Optimum absorber parameters for simple systems   总被引:1,自引:0,他引:1  
In the classical problem a damped one degree-of-freedom absorber system is attached to a main system, which has one degree of freedom and is undamped. The optimum values of absorber stiffness and damping, which will minimize the resonant response of the main mass, are well known. In this paper the effect on these optimum conditions of light damping in the main system is studied. The authors show that optimum parameters for absorbers, which are attached to beams and plates, can be obtained simply and accurately from those for an equivalent one degree-of-freedom main system. This depends upon the concept of an effective mass for the elastic body and the representation of its response by the single relevant mode. It will be shown in a later paper that for more complex elastic bodies such as cylindrical shells, for which the natural frequencies are more closely spaced, these simple concepts do not predict accurately optimum absorber parameters.  相似文献   

4.
基岩弹性刚度对土层地震反应的影响   总被引:4,自引:1,他引:3  
将基岩上均匀、各向同性土层的地震反应,简化为置于弹性支座上的一维剪切梁模型进行分析。将地震激励假定为白噪声谱,在随机边界激励下,主要探讨了土层与基岩2种介质间的波阻抗比、波速比、土层厚度和阻尼特性对土层地震反应的影响。计算结果表明,对于一定的土层厚度,在一定阻尼比条件下,土层和基岩的阻抗比小到一定程度时,可以将基岩假定为刚性约束,而误差可以控制在一定的范围内。  相似文献   

5.
Modal properties of tuned mass damper (TMD)-structure two-degree-of-freedom (2DOF) linear systems are studied employing a perturbation technique. Using the perturbation solutions, formulas relevant to designing the TMD for various types of loading are obtained; they are expressed as a function of mass ratio, tuning ratio, damping ratio of the TMD and damping ratio of the structure. Equivalent additional dampings of the structure due to the TMD are derived for random and harmonic forces. Matched expressions of equivalent damping, which are valid for detuned, i.e. non-optimal, conditions are also presented. The stability boundary of TMD-structure systems subject to linear self-excited forces is derived in a closed form. Using the perturbation solutions, procedures for optimizing the TMD parameters for various types of loading are explained and the optimal values are derived. The formulas obtained in this study can be used with good accuracy for mass ratios less than 0.02.  相似文献   

6.
The soil-structure system is modelled as a uniform vertical beam, which terminates in a base or foundation mass; this mass is attached to the surface of an elastic half-space. Using known force-displacement relations for the coupled vibrations of a rigid disc on an elastic half-space, the natural frequencies and response to a transverse harmonic force, applied at the tip of the beam, are determined through a continuum approach. Effectively the problem reduces to a beam with frequency-dependent boundary conditions. A parametric study shows that changes in the three ratios, Young's modulus for the beam to that for the half-space, the radius of the base mass to the length of the beam, L, and the second moment of area of the beam cross-section/L4, cause large variations in the maximum response, which due to interaction can be considerably smaller or larger than that for a comparable fixed-base cantilever beam. This dynamic behaviour can be explained by considering the variation of natural frequencies, mode shapes and modal damping factors with these ratios. A brief study of the response of the structure to a free-field harmonic acceleration, applied at the soil-structure interface, suggests that interaction depends upon material and geometric properties of the system, rather than on the nature of the excitation.  相似文献   

7.
Optimal displacement feedback control law is derived for a vibration control of a single‐degree‐of‐freedom structure with an active tuned mass damper (ATMD). Analytical expressions of the linear quadratic regulator (LQR) feedback gains for the ATMD are derived by solving the Ricatti equation straightforwardly. Based on these solutions, it is found that if the stiffness of the tuned mass damper (TMD) is calibrated to satisfy a certain condition, the control law is simplified to be composed of the feedback gains only for the displacement of the structure and the velocity of the auxiliary mass stroke, which is referred to as ‘optimal displacement feedback control’. The mean‐square responses of the structure as well as the auxiliary mass against Gaussian white noise excitations are evaluated by solving the Lyapunov equation analytically based on the stochastic optimal control theory. Using these analytical solutions, the optimal damping parameter for the auxiliary mass is also derived. Finally, the optimal displacement feedback control law is presented. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

8.
It is demonstrated that the addition of a tuned mass-spring-dashpot system with a relatively small mass and a high damping ratio can be an effective way to increase the inherent damping characteristics of buildings and reduce, thus, their response to earthquake excitations. The demonstration is based on a theoretical formulation and on numerical and experimental studies that confirm this formulation. In the theoretical formulation, it is shown first that, if certain conditions are satisfied, the damping ratios in two of the modes of the system that is formed by a building and an appendage in resonance are approximately equal to the average of the corresponding damping ratios of the building and the appendage. Based on this finding, it is then shown that an attached appendage with a high damping ratio and tuned to the fundamental frequency of a building may increase the damping ratio in the fundamental mode of the building to a value close to half the damping ratio of the appendage. In the numerical study, the response of a ten-storey shear building is analysed under two different earthquake ground motions with and without the proposed resonant appendages. Appendages with damping ratios of 20 and 30 per cent are considered. In this study, it is found that under one of the ground motions the maximum displacement of the building's roof is reduced 30 per cent with the appendage with 20 per cent damping and 39 per cent with the one with 30 per cent damping. Similarly, with these two appendages the building's base shear is reduced 31 and 41 per cent, respectively. In the experimental study, a wooden three-storey structural model is tested in a shaking table with and without an appendage designed and constructed to have a damping ratio of 53-5 per cent. The test is conducted under random and sinusoidal base excitations. In the shaking table test under random excitation, the attached appendage reduces the response of the model 38-6 per cent, while in that under sinusoidal vibration 45-2 per cent.  相似文献   

9.
This paper considers the response of a beam with a dynamic vibration absorber, which consists of a viscoelastic solid and a double-cantilever viscoelastic beam, attached to the centre of the main beam. The ends of the main beam are built in and excited sinusoidally by the base motion. The transfer matrix method is used in the analysis. The displacement transmissibility, i.e. the ratio of the displacement at the centre of the main beam to that of the base is investigated in the numerical example. It is shown that the present absorber is effective to suppress several resonances of the main beam simultaneously by only one compact device. Values of the optimum tuning design parameters are presented in the numerical example.  相似文献   

10.
It is well established that small tuned mass dampers (TMDs) attached to structures are very effective in reducing excessive harmonic vibrations induced by external loads but are not as interesting within the context of earthquake engineering problems. For this reason, large mass ratio TMDs have been proposed with the objective of adding a significant amount of damping to structures, thus constituting a good means of reducing structural response in these cases. This solution has other important and attractive dynamic features such as robustness to system uncertainties and reduction of the motion of the inertial mass. In this context, this paper aims to describe an alternative methodology to existing procedures used to tune these devices to earthquake loads and to present some additional considerations regarding its performance in controlling seismic vibrations. The main feature of the proposed method consists of establishing a direct proportion between the damping ratios of the structure's first two vibration modes and the adopted mass ratio. By equalizing the damping ratios of the system's main vibration modes, this proposal also facilitates the use of simplified methods, such as modal analysis based on response spectra. To demonstrate the usefulness of this alternative methodology, an application example is presented, which was also used to perform a parametric study involving other tuning methods and to estimate mass ratio values from which there is no significant advantage in increasing the TMD mass. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
This paper investigates the dynamic behavior and the seismic effectiveness of a non‐conventional Tuned Mass Damper (TMD) with large mass ratio. Compared with conventional TMD, the device mass is increased up to be comparable with the mass of the structure to be protected, aiming at a better control performance. In order to avoid the introduction of an excessive additional weight, masses already present on the structure are converted into tuned masses, retaining structural or architectural functions beyond the mere control function. A reduced order model is introduced for design purposes and the optimal design of a large mass ratio TMD for seismic applications is then formulated. The design method is specifically developed to implement High‐Damping Rubber Bearings (HDRB) to connect the device mass to the main structure, taking advantage of combining stiffness and noticeable damping characteristics. Ground acceleration is modeled as a Gaussian random process with white noise power spectral density. A numerical searching technique is used to obtain the optimal design parameter, the frequency ratio alpha, which minimizes the root‐mean‐square displacement response of the main structure. The study finally comprises shaking table tests on a 1:5 scale model under a wide selection of accelerograms, both artificial and natural, to assess the seismic effectiveness of the proposed large mass ratio TMD. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
Dynamic characteristic and harmonic response of adjacent buildings connected by fluid damper were experimentally investigated using model buildings and fluid damper. Two building models were constructed as two three-storey shear buildings of different natural frequencies. Model fluid damper connecting the two buildings was designed as linear viscous damper of which damping coefficient could be adjusted. The two buildings without fluid dampers connected were first tested to obtain their individual dynamic characteristics and responses to harmonic excitation. The tests were then carried out to determine modal damping ratios of the adjacent buildings connected by the fluid damper of different damping coefficients and at different locations. Optimal damper damping coefficient and location for achieving the maximum modal damping ratio were thus found. The measured modal damping ratios and harmonic responses of the building-fluid damper system were finally compared with those from the individual buildings. The comparison showed that the fluid damper of proper parameter could significantly increase the modal damping ratio and tremendously reduce the dynamic response of both buildings. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

13.
Two storey bilinear hysteretic structures have been studied with a view to exploring the possibility of using the dynamic vibration absorber concept in earthquake-resistant design. The response of the lower storey has been optimized for the Taft 1952, S69°E accelerogram with reference to parameters such as frequency ratio, yield strength ratio and mass ratio. The influence of viscous damping has also been examined.  相似文献   

14.
This study aims at evaluating the optimal properties of friction pendulum bearings to be employed for the seismic protection of elastic isolated structural systems under earthquake excitations with different characteristics in terms of frequency content. A two-degree-of-freedom model is considered to describe the isolated system behavior while accounting for the superstructure flexibility and a non-dimensional formulation of the governing equations of motion is employed to relate the characteristic parameters describing the isolator and structure properties to the response parameters of interest for the performance assessment. Seismic excitations are modeled as time-modulated filtered Gaussian white noise random processes of different intensity within the power spectral density method. The filter parameters control the frequency content of the random excitations and are calibrated to describe stiff, medium and soft soil conditions, respectively. Finally, multi-variate regression expressions are obtained for the optimum values of the friction coefficient that minimize the superstructure displacements relative to the base mass as a function of the structural system properties, of the seismic input intensity and of the soil condition.  相似文献   

15.
A third-order correction was recently suggested to improve the accuracy of the half-power bandwidth method in estimating the damping of single DOF systems.This paper analyzes the accuracy of the half-power bandwidth method with the third-order correction in damping estimation for multi-DOF linear systems.Damping ratios in a two-DOF linear system are estimated using its displacement and acceleration frequency response curves,respectively.A wide range of important parameters that characterize the shape of these response curves are taken into account.Results show that the third-order correction may greatly improve the accuracy of the half-power bandwidth method in estimating damping in a two-DOF system.In spite of this,the half-power bandwidth method may significantly overestimate the damping ratios of two-DOF systems in some cases.  相似文献   

16.
以平面框架结构为例阐述了结构平稳随机地震反应时域分析方法的应用。首先利用静力凝聚方法大幅度地缩减结构的自由度数目,形成一维链状模型,使得结构运动方程中只包含各层反应从而大大降低计算工作量。其次推导了结点随机反应和层间随机反应的计算公式,可以方便地获得结构在理想白噪声、金井清谱和改进金井清谱三种随机地震地面运动激励下的协方差位移反应函数和协方差速度反应函数。最后通过一个单跨双层的平面框架结构实例,阐述了这种方法的使用过程。  相似文献   

17.
调谐结构体系在地震作用下的参数配置研究   总被引:2,自引:0,他引:2  
为研究调谐结构体系在基底水平地震作用下的减震效果,采用有代表性的两质点模型,从简谐激励出发得出了稳态位移响应表达式和影响参数。在此基础上,计算了子结构周期影响,得出其优化配置公式;分析了子结构与基本结构质量比的影响及配置;分析了基本结构周期、结构阻尼对减震效果的影响。进一步评析了调谐体系在宽带地震反应控制中的参数配置。研究指出质量比是地震作用下高效减震控制的重要参数,并指出了基本结构周期配置的重要性。  相似文献   

18.
Optimum parameters are determined for absorbers, which, when attached to one mass of a main system with two degrees of freedom, minimize the harmonic response of that mass. Comparison is made with the absorber parameters that are determined by treating the main system as an equivalent one degree-of-freedom system and using classical results. Close agreement is obtained if the ratio of the two natural frequencies of the main system is reasonably large. This is in agreement with the author's recent work on optimum absorber parameters which minimize the response of elastic bodies. The extension of the method to multi degree-of-freedom main systems is outlined. The conditions for which different values of these parameters are predicted when the response is minimized over narrow and broad frequency bands are determined.  相似文献   

19.
The dynamic behaviour of two adjacent single‐degree‐of‐freedom (SDOF) structures connected with a viscous damper is studied under base acceleration. The base acceleration is modelled as harmonic excitation as well as stationary white‐noise random process. The governing equations of motion of the connected system are derived and solved for relative displacement and absolute acceleration responses of connected structures. The response of structures is found to be reduced by connecting with a viscous damper having appropriate damping. For undamped SDOF structures, the closed‐form expressions for optimum damping of viscous damper for minimum steady state as well as minimum mean square relative displacement and absolute acceleration of either of the connected SDOF structures are derived. The optimum damper damping is found to be functions of mass and frequency ratio of two connected structures. Further, numerical results had indicated that the damping of the connected structures does not have noticeable effects on the optimum damper damping and the corresponding optimized response. This implies that the derived closed‐form expressions for optimum damper damping of undamped structures can also be used in practical applications for damped structures. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

20.
在实际工程场地中,很多土层可视为水平分层,各层土的物理和力学性质存在差异,其中包括土的振动阻尼比。本文讨论水平分层土层系统的等效阻尼比的近似计算方法,基于5个不同的加权函数推导了10种等效阻尼比的计算公式。通过2个算例,分别以等效阻尼比为参数计算水平分层土层的地震反应,并与准确解相比较,分析了不同等效阻尼比近似计算方法的计算精度。数值结果表明,若等效阻尼比计算方法选择不恰当,会导致土层地震反应的计算结果出现较大误差。针对2种不同类型的水平分层土层,建议采用基于三角形分布的加权函数来计算土层系统的等效阻尼比。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏