首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper is based on the premise that the damping mechanism of a multidegree of freedom structure can be represented by viscous and coulomb dampers. A closed form solution for the structure subjected to a sinusoidal forcing function is presented. The solution is used as the basis of a method for determining relative amounts of viscous and coulomb damping from vibration tests. The method was applied to the results of a series of vibration tests on a five storey reinforced concrete structure and approximate values of viscous and coulomb damping obtained. A comparison of the effect of various combined damping values on the earthquake response of the structure was made. It was concluded that the use of the equivalent viscous damping concept to approximate the combined effect of viscous and coulomb damping results in a low estimate of the elastic response of the structure.  相似文献   

2.
Vibration control systems are being used increasingly worldwide to provide enhanced seismic protection for new and retrofitted buildings. This paper presents a new vibration control system on the basis of a seesaw mechanism with viscoelastic dampers. The proposed vibration control system comprises three parts: brace, seesaw member, and viscoelastic dampers. In this system, only tensile force appears in bracing members. Consequently, the brace buckling problem is negligible, which enables the use of steel rods for bracing members. By introducing pre‐tension in rods, long steel rods are applicable as bracing between the seesaw members and the moment frame connections over some stories. Seesaw mechanisms can magnify the damper deformation according to the damper system configuration. In this paper, first, the magnification factor, that is, the ratio of the damper deformation to the story drift, is delivered, which includes the rod deformation. Results of a case study demonstrate that the magnification factor of the proposed system is greater than unity for some cases. Seismic response analysis is conducted for steel moment frames with the proposed vibration control system. Energy dissipation characteristics are examined using the time‐history response results of energy. The maximum story drift angle distributions and time‐history response results of displacement show that the proposed system can reduce the seismic response of the frames effectively. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
The damping reduction factors are used in a few building codes in order to estimate the elastic response spectrum with high damping ratios from its 5%‐damped counterpart. At present, much research regarding this factor has been published. The purpose of this paper is to evaluate the accuracy of five different models of damping reduction factors. In addition, the damping reduction factors adopted in the recent U.S.A. seismic codes are also evaluated. Statistical studies are carried out according to a total of 216 earthquake ground motions recorded on firm sites in California. Considered here are elastic single‐degree‐of‐freedom (SDOF) systems with natural vibrating periods between 0.1 and 6.0 s. Mean ratios and dispersion of approximate to exact maximum elastic displacement demands corresponding to various damping reduction factors are computed as functions of the natural vibrating period and the viscous damping ratio. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

4.
A base-isolated building is liable to have a small horizontal eccentricity between the centre of mass of the superstructure and the centre of rigidity of the supporting bearings. In seismic analysis, the structure is modelled as a rigid block with tributary masses supported on massless elastomeric rubber bearings placed at a constant elevation below the centre of mass. This simplified system has three degrees of freedom: two translations and one rotation in the vertical plane. The investigation of the dynamic behaviour of a base-isolated building is carried out for both the detuned and the perfectly tuned cases. In the detuned case, the natural frequencies of the system are assumed to be well separated. In the perfectly tuned case, the uncoupled rocking frequency is assumed to be identical to the vertical translational frequency, which may result from an unusual mass distribution and/or an extreme aspect ratio of the superstructure. Perturbation methods are implemented in finding the dynamic characteristics for both cases. However, the dynamic response of the perfectly tuned case is the major concern in this investigation. The Green's functions for the displacement response of the three-degree-of-freedom system are derived for both the undamped and damped conditions. The response spectrum modal superposition method is used in estimating the maximum acceleration response. A simple method, accounting for the effect of closely spaced modes, is proposed for combining modal maxima and results in an approximate solution corresponding to a single-degree-of-freedom system. This approximate solution may be used for the preliminary design of a base-isolated structure. Numerical results for a base-isolated building subjected to the vertical component of the El Centro earthquake of 1940 were carried out for comparison with these analytical results. The proposed modal combination method showed superiority over the conventional Square Root of the Sum of the Squares method in estimating maximum responses. The results also indicated that the approximate single-degree-of-freedom system yields accurate estimations. It is shown that the effect of rocking coupling on the vertical response of base-isolated structures subjected to transient loadings, such as earthquake motions, can generally be neglected as a result of the combined effects of the time lag between the maximum translational and rotational responses and the influence of damping in the isolation system, which for elastomeric bearings can be as high as 8 to 10 per cent of critical.  相似文献   

5.
Semi‐active control of buildings and structures for earthquake hazard mitigation represents a relatively new research area. Two optimal displacement control strategies for semi‐active control of seismic response of frame structures using magnetorheological (MR) dampers or electrorheological (ER) dampers are proposed in this study. The efficacy of these displacement control strategies is compared with the optimal force control strategy. The stiffness of brace system supporting the smart damper is also taken into consideration. An extensive parameter study is carried out to find the optimal parameters of MR or ER fluids, by which the maximum reduction of seismic response may be achieved, and to assess the effects of earthquake intensity and brace stiffness on damper performance. The work on example buildings showed that the installation of the smart dampers with proper parameters and proper control strategy could significantly reduce seismic responses of structures, and the performance of the smart damper is better than that of the common brace or the passive devices. The optimal parameters of the damper and the proper control strategy could be identified through a parameter study. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

6.
The effectiveness of introducing Coulomb damping in structures to reduce seismic response is evaluated. Response characteristics of simple one-degree-of-freedom structures with sliding interfaces between the top slab and supporting frame and between the base and foundation are studied and compared. It is shown that, analytically, the top slab sliding system is a special case of the base sliding system. The slab sliding system is seen to offer certain advantages over the base sliding system inasmuch as it provides a more effective reduction in the lateral forces in the supporting frame as well as a better isolation of supported secondary systems, as depicted by a significantly reduced level of floor spectrum response. The analytical ease of predicting the response of the slab sliding system is also demonstrated. The required unobstructed sliding displacements seem to be reasonable except, may be, for flexible systems. The similarities and differences between the hysteretic and slab sliding systems are also highlighted by comparison of their response results.  相似文献   

7.
Seismic response of slender rigid structures with foundation uplifting   总被引:2,自引:0,他引:2  
The rocking of rigid structures uplifting from their support under strong earthquake shaking is investigated. The structure is resting on the surface of either a rigid base or a linearly elastic continuum. A large-displacement approach is adopted to extract the governing equations of motion allowing for a rigorous calculation of the nonlinear response even under near-overturning conditions. Directivity-affected near-fault ground motions, idealized as Ricker wavelets or trigonometric pulses, are used as excitation. The conditions under which uplifting leads to large angles of rotation and eventually to overturning are investigated. A profoundly nonlinear rocking behavior is revealed for both rigid and elastic soil conditions. This geometrically nonlinear response is further amplified by unfavorable sequences of long-duration pulses in the excitation. Moreover, through the overturning response of a toppled tombstone, it is concluded that the practice of estimating ground accelerations from overturning observations is rather misleading and meaningless.  相似文献   

8.
向心式变摩擦阻尼器控制结构地震反应分析   总被引:4,自引:0,他引:4  
介绍了向心式变摩擦阻尼器的原理及其基本力学性能,探讨了安装向心式变摩擦阻尼器结构在自由振动和强迫振动时的动力特性和动力反应特点,揭示了向心式变摩擦阻尼器引起结构抖振的机理,对安装向心式变摩擦阻尼器的结构的地震反应进行了分析,研究了向心式变摩擦阻尼器的参数对结构动力特性及地震反应的影响,给出了受控结构的非线性反应谱.  相似文献   

9.
高层钢结构地震反应形状记忆合金拉索控制研究   总被引:3,自引:0,他引:3  
本文通过形状记忆合金(SMA)材料的超弹性性能试验确定了SMA材料的各项参数和常温状态下的本构模型。对采用SMA拉索实施振动控制的20层钢结构的Benchmark模型的地震响应进行了时程分析。计算结果表明,实施SMA拉索控制后,层间相对位移可降低70%左右,且SMA材料很好的耗能作用有效地减少了地震能量向上部楼层的传递,对上部结构具有一定的隔振作用;顶层相对位移的控制效果达到51%;顶层加速度可降低43%;地震波强度和拉索初应变对拉索的被动控制效果影响较大。最后给出了拉索的安装位置与拉索的应变之间的关系曲线,建议了合理的布置方案。  相似文献   

10.
A method is presented to obtain the exact complex-valued eigenproperties of a classically damped structure and equipment system. The non-classically damped character of the combined system as well as the effect of dynamic interaction between primary structure and equipment are properly included in the calculation of these eigenproperties. It is necessary only to know the classical modal properties of the structure and, of course, the equipment characteristics. The eigenvalues are obtained as the solution of a non-linear equation which can be easily solved by the Newton–Raphson algorithm. Once the eigenvalues are known, the corresponding eigenvectors are obtained from simple closed-form expressions. The method can be used equally effectively with light as well as heavy equipment. Numerical results demonstrating the effectiveness of the method are presented. A procedure which utilizes the complex-valued eigenproperties is developed for calculating the floor response spectra directly from the ground spectra. Numerical results of floor response spectra obtained from this procedure are presented. The floor spectra calculated by this approach include the structure–equipment interaction effect.  相似文献   

11.
The feasibility of using viscoelastic (VE) dampers to mitigate earthquake-induced structural response is studied in this paper. The properties of VE dampers are briefly described. A procedure for evaluating the VE damping effect when added to a structure is proposed in which the damping effect of VE dampers is incorporated into modal damping ratios through an energy approach. Computer simulation of the damped response of a multi-storey steel frame structure shows significant reduction in floor displacement levels.  相似文献   

12.
13.
Summary A computational method (based on finite differences) is proposed for the seismic response analysis of the Earth's structures. The method is applied to the earth fill and the sedimentary basin. It was found that the lateral inhomogeneity of non-absorbing structures caused remarkable effects on synthetic seismograms, viz. strong horizontal reflections at later arrivals. In absorbing structures these effects are much less pronounced and the response is determined primarily by the variable thickness of the structures. The responses of structures with non-causal or causal absorption differ only slightly, but they are strongly influenced by the magnitude of the absorption itself.  相似文献   

14.
本文用墙单元将剪力墙中断的框架-剪力墙结构离散,利用传递矩阵技术探讨此不规则框架-剪力墙结构的地震反应,四阶Runge-Kutta法用来求解用正则坐标写出的对应于第j个振型的运动方程.将得到的3个不同剪力墙高度的钢筋混凝土框架-剪力墙模型结构的固有频率、最大位移反应和基底剪力与振动台的试验结果进行对比,说明本数值方法是正确的、有效的.最后得出了并不是对所有的框架-剪力墙结构都需把其剪力墙延伸到整个结构高度的结论以及用墙单元和传递矩阵技术求解能有效地减少计算单元、取得同样精度的计算结果.  相似文献   

15.
The maximum ductility demand and the edge displacement of a simple single mass eccentric model is evaluated when the system is subjected to ground motions represented by the El Centro 1940 and Taft 1952 earthquake records. The resisting elements are taken to be bilinear hysteretic. It is found that the ductility demand depends to a great extent on the energy content of the ground motions, particularly in the period range beyond the elastic period of the system. Unlike elastic response, the coincidence of uncoupled torsional and lateral frequencies does not lead to exceptionally high inelastic response. An increase by a factor of two in ductility demand is not uncommon for a system with large eccentricity as compared to a symmetrical system. Therefore, system eccentricity has a larger effect on ductility demand than earlier studies indicated. Using Clough's model to allow for stiffness degradation effect, results are found to be within 20 per cent of those calculated based on the bilinear hysteretic model.  相似文献   

16.
The bidirectional response of a two-storey RC frame structure with two adjacent sides infilled is studied through shaking table tests and non-linear dynamic analyses. The pre-cracking stiffness of the infills is large enough to impose twisting of the infilled structure about the common corner of the two infilled sides, with predominant period close to that of translation of the symmetric bare structure in the two horizontal directions. Parametric analyses and test results show that the peak displacement components of the corner column of the two open sides are about the same as (or slightly less than) those of the bare structure under the same bidirectional excitation, but take place simultaneously. This simultaneity of peak local demands from the two components of the motion seems to be the only effect of plan-eccentric infilling that needs to be taken into account in the design of the RC structure. Despite their very high slenderness (height-to-thickness ratio of about 30), infill panels survive out-of-plane peak accelerations of 0·6g at the base of the structure or 1·3–1·75g at their centre. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

17.
Active multiple tuned mass dampers (referred to as AMTMD), which consist of several active tuned mass dampers (ATMDs) with identical stiffness and damping coefficients but varying mass and control force, have recently been proposed to suppress undesirable oscillations of structures under ground acceleration. It has been shown that the AMTMD can remarkably improve the performance of multiple tuned mass dampers (MTMDs) and is also more effective in reducing structure oscillation than single ATMDs. Notwithstanding this, good performance of AMTMD (including a single ATMD illustrated from frequency-domain analysis) may not necessarily translate into a good seismic reduction behavior in the time-domain. To investigate these phenomena, a three-story steel structure model controlled by AMTMD with three ATMDs was implemented in SIMULINK and subjected to several historical earthquakes. Likewise, the structure under consideration was assumed to have uncertainty of stiffness, such as 4-15% of its initial stiffness, in the numerical simulations. The optimum design parameters of the AMTMD were obtained in the frequency-domain by implementing the minimization of the minimum values of the maximum dynamic magnification factors (DMF) of general structures with AMTMD. For comparison purposes, response analysis of the same structure with a single ATMD was also performed. The numerical analysis and comparison show that the AMTMD generally renders better effectiveness when compared with a single ATMD for structures subjected to historical earthquakes. In particular, the AMTMD can improve the effectiveness of a single ATMD for a structure with an uncertainty of stiffness of 4-15% of its initial stiffness.  相似文献   

18.
The concept of the hybrid passive control system is studied analytically by investigating the seismic response of steel frame structures. Hybrid control systems consist of two different passive elements combined into a single device or system. The hybrid systems investigated in this research consist of a rate‐dependent damping device paired with a rate‐independent energy dissipation element. The innovative configurations exploit individual element strengths and offset their weaknesses through multiphased behavior. A nine‐story, five‐bay steel moment‐frame was used for the analysis. Six different seismic resisting systems were analyzed and compared. The conventional systems included a special moment‐resisting frame (SMRF) and a dual SMRF–buckling‐restrained brace (BRB) system. The final four configurations are hybrid passive systems. The different hybrid configurations utilize a BRB and either a high‐damping rubber damper or viscous fluid damper. The analyses were run in the form of an incremental dynamic analysis. Several damage measures were calculated, including maximum roof drift, base shear, and total roof acceleration. The results demonstrate the capability of hybrid passive control systems to improve structural response compared with conventional lateral systems and to be effective for performance‐based seismic design. Each hybrid configuration improved some aspect of structural response with some providing benefits for multiple damage measures. The multiphased nature provides improved response for frequent and severe seismic events. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
大跨度张弦梁结构的地震响应分析   总被引:9,自引:2,他引:9  
本文分析了预张力的大小、撑杆的数目、地震的行波效应和结构约束条件对大跨度张弦梁结构地震响应的影响。结果表明:结构的初始地震响应随着索内预张力的增大而增大,然后逐渐趋于接近,与预张力大小无关;撑杆的数目和位置对结构的地震响应影响很小;与地震波的一致输入相比,考虑行波效应的索应力响应峰值增大62.9%,竖向位移响应峰值增大36.2%;张弦梁结构的地震响应对支座约束条件很敏感,约束条件改变,地震响应改变很大。  相似文献   

20.
An analytical study of the seismic response of typical base isolated structures mounted on rubber bearings is presented. Isolated buildings are liable to have closely spaced lower modes of vibration with small eccentricity between centres of mass and rigidity. The isolated structure is modelled as a rigid deck with lumped masses supported on axially inextensible elastomeric rubber bearings. This simplified system has three degrees of freedom (dof), two translations and one rotation in the horizontal plane. The Green's functions for the displacement response of the 3 dof system are derived for both undamped and damped cases with small and large eccentricities. The small eccentricity case is taken from a specific isolated building, while the large eccentricity case arises from the 5 per cent accidental eccentricity which is required by various seismic codes. An interaction equation for normalized displacements is established for an idealized flat velocity spectrum or hyperbolic acceleration spectrum. An isolated building on rubber bearings would have its fundamental period fall into this range of a design spectrum. Numerical results for the specific building subjected to the El Centro earthquake of 1940 are presented. Both the time history and the response spectrum modal superposition analysis were performed. In the response spectrum analysis, the Complete Quadratic Combination (CQC) showed superiority over the Square Root of the Sum of Squares (SRSS) in estimating maximum responses. It is concluded that the effect of torsional coupling on the transient response of base isolated structures is insignificant, due to the combined effect of the time lag between the maximum translational and torsional responses and the influence of damping in the isolation system which for elastomeric bearings can be as high as 8 to 10 per cent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号