首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Ballast water is a likely cause for worldwide transfer of non-indigenous aquatic species because of the large volumes and frequency of possible inoculations. Ozone is one treatment option being considered for eliminating non-indigenous species in ballast water. When ozone is applied to seawater, secondary disinfectants are formed, commonly measured and expressed as total residual oxidant (TRO). The goal of this study was to determine those variables most likely to affect the rate of TRO increase during ozonation and the subsequent TRO decline that occurs over time. These parameters strongly influence the efficacy of ozone treatments aimed to eliminate organisms present in ballast water. Seawater was obtained from Puget Sound, Washington; Cape Fear, North Carolina; and San Francisco Bay. Results indicated that seawater characteristics, including the organic content and ammonia, affect the amount of ozone required to achieve a desired TRO level and rate of TRO decay, and therefore need to be considered in determining ozone requirements for ballast water treatment.  相似文献   

2.
Ballast water is a major pathway for the transfer of non-indigenous species in aquatic environments. The objectives of this study were to determine the ability of ozone to reduce the numbers of a spectrum of marine organisms collected from Puget Sound, Washington in replicated mesocosm (280 l) experiments, and estimate the minimum ozone concentrations as measured by total residual oxidant (TRO) required to reduce organism densities. Ozone treatment was effective in removing bacteria, phytoplankton, and mesozooplankton with initial TRO concentrations of 2–5 mg l−1 as Br2. Persistence of TRO resulted in an extended period of toxicity and cumulative mortality. TRO decay allowed bacteria populations to multiply when TRO levels fell below 0.5–1.0 mg l−1 as Br2. Phytoplankton chlorophyll a concentrations were rapidly reduced by ozone treatment and did not increase in any treatments or controls because of lack of light. Overall mesozooplankton viability was rapidly reduced by 90–99% in treatment TRO levels above 1.85 mg l−1 as Br2. Our study outlines novel protocols that can be used for testing different potential ballast water treatment systems in replicated and controlled mesocosm experiments.  相似文献   

3.
Dinoflagellate cysts are well-recognized biological constituents of ships' ballast tanks. They are present in ballast water, sediments and residual water in drained tanks, and in biofilms formed on interior tank surfaces. Therefore, cysts have the potential to be released during ballast discharge. The International Maritime Organization's (IMO) Ballast Water Management Convention (promulgated February 2004) stipulates a performance standard (Annex, Regulation D2) requiring discharged ballast water contain <10 viable organisms between 10 and 50 microm per ml and <10 viable organisms 50 microm per m3. The proposed size limit has potential to exclude both the smallest toxic and the largest toxic and non-toxic dinoflagellate (and other microalgal) cysts from discharged ballast water. Despite the appropriateness of size cutoffs however, ballast water containing predominantly small cysts (<50 microm) could be deemed in compliance with the performance standard, even without treatment, while ballast water having the same concentration of larger cysts (>50 microm) could require a multiple-log reduction in abundance before its permissible discharge. Also of concern, it remains uncertain whether ballast-water treatment can remove sufficient organisms, including dinoflagellate cysts, to meet the performance standard.  相似文献   

4.
Since 2005, five different ballast water management systems (BWMSs) based on chlorination treatment have been tested by Norwegian Institute for Water Research (NIVA) according to guidelines from the International Maritime Organization (IMO). 25% and >50% of all the tested discharge samples exhibited acute and chronic toxic effects on algae, respectively. In most cases this toxicity was plausibly caused by a high free residual oxidant (FRO) level (>0.08 mg Cl/l). Of the 22 disinfection by-products (DBPs) that were identified in treated water at discharge, four compounds were at times found at concentrations that may pose a risk to the local aquatic environment. However, there seemed to be no clear indication that the measured DBP concentrations contributed to the observed algal toxicity. The addition of methylcellulose instead of lignin in the test water to comply with IMO requirements seemed to limit the formation of DBP.  相似文献   

5.
《Marine pollution bulletin》2012,65(12):2742-2748
Ballast water has been identified as one of the key pathways for the movement of species between different ecosystems. The purpose of this study is to evaluate the biological efficacy and the potential toxicological impact of a proposed ballast water treatment using hydroxyl radicals as the main active substances. Living biomass of organisms kept in treated water for 2 days met the requirement stated in the International Maritime Organization (IMO) Ballast Water Convention (Regulation D-2), and no re-growth was observed over a period of 5 days. Aquatic toxicity tests of three trophic levels for the treated ballast water were performed. The results indicated that the toxicological risk of the discharge water to the receiving environment was not significant.  相似文献   

6.
Ship board testing of a deoxygenation ballast water treatment   总被引:2,自引:1,他引:1  
A ship board trial of a deoxygenation method for treating ballast water was carried out during a voyage from Southampton (United Kingdom) to Manzanillo (Panama). A nutrient solution added to two ballast tanks encouraged bacterial growth, resulting in a gradual change to an anoxic environment. Samples were taken from two treated tanks and two untreated tanks to assess changes in the abundance and viability of zooplankton, phytoplankton and bacteria. The work was carried out before the International Maritime Organization (IMO) standard was agreed so only a broad indication of whether the results achieved the standard was given. For the zooplankton, the standard would have been achieved within 5 or 7 days but the phytoplankton results were inconclusive. The biological efficacy was the result of the combination of several factors, including the treatment, pump damage and an increase in the water temperature during the voyage.  相似文献   

7.
The human mediated transfer of harmful organisms via shipping, specifically via ballast water transport, leading to the loss of biodiversity, alteration of ecosystems, negative impacts on human health and in some regions economic loss, has raised considerable attention especially in the last decade. Ballast water sampling is very important for biological invasions risk management. The complexity of ballast water sampling is a result of both the variety of organism diversity and behaviour, as well as ship design including availability of ballast water sampling points. Furthermore, ballast water sampling methodology is influenced by the objectives of the sampling study. In the course of research conducted in Slovenia, new sampling equipment for ships' ballast water was developed and tested. In this paper new ballast water sampling methods and equipment together with practical shipboard testing results are presented.  相似文献   

8.
A ballast water short-time high temperature heat treatment technique was applied on board a car-carrier during a voyage from Egypt to Belgium. Ballast water from three tanks was subjected for a few seconds to temperatures ranging from 55 degrees C to 80 degrees C. The water was heated using the vessel's heat exchanger steam and a second heat exchanger was used to pre-heat and cool down the water. The treatment was effective at causing mortality of bacteria, phytoplankton and zooplankton. The International Maritime Organization (IMO) standard was not agreed before this study was carried out, but comparing our results gives a broad indication that the IMO standard would have been met in some of the tests for the zooplankton, in all the tests for the phytoplankton; and probably on most occasions for the bacteria. Passing the water through the pump increased the kill rate but increasing the temperature above 55 degrees C did not improve the heat treatment's efficacy.  相似文献   

9.
The transport of non-indigenous species (NIS) with ship ballast water is a major environmental problem. The International Maritime Organisation (IMO) have recommended that ballast tanks are flushed through with sea water to remove NIS contaminants. The flushing efficiency is studied using mathematical models and a scaled experimental model of a ballast tank. The density contrast between the ballast water and water used for flushing is important when the Froude number Fr(w)=U(w)/sqr rt|g(')|H < 1 (defined in terms of average horizontal flow U(w), reduced buoyancy g', and H the vertical dimension in the tank). When denser water is used to flush a ballast tank, from below, it efficiently displaces lighter ballast water; but flushing through with light water creates a buoyant gravity current which effectively short circuits part of the tank. When Fr(w)>1, the density contrast between the ballast water and water used for flushing is not important and flushing is controlled by a bulk Péclet number, Pe(w). For Pe(w)<1 perfect mixing occurs, while for Pe(w)>1 displacement flushing occurs. Laboratory experiments of flushing were performed using a model two-dimensional ballast tank employing dye attenuation to measure the whole concentration field and these experiments confirm the essential features of the mathematical models. The results of this study are discussed in the context of current IMO flushing protocols.  相似文献   

10.
The proposed MTB is a process to expedite the implementation of international standards and regulations, and the subsequent testing, certification, and regulatory approval of new ballast water treatment ("control") technologies. This would expedite their acceptance in the global marketplace and reduce risks of shipowners following international regulation. The cost to test and evaluate and certify new ballast water treatment technologies for the global marketplace has been estimated to be less than US $1 per day per ship. It is time for the shipping industry, national regulatory bodies, and IMO to endorse the concept of the MTB and for the shipping industry to support a proactive cost-saving solution for sustainable shipping and protecting the environment from unwanted invasions of aquatic species with their potential negative impacts.  相似文献   

11.
The ongoing transfer of harmful organisms by shipping, especially via ballast water transport, may result in a change of biodiversity, alteration of ecosystems, negative impacts on human health and economic loss. Species introductions which cause irreversible consequences to receiving environments and economies call for particular attention. One critical issue is a need to evaluate the quantities and processes of species introductions. Consequently ballast water was sampled on 15 ships calling at the Port of Koper, Slovenia. This was the first ballast water sampling study in the Mediterranean Sea. This paper summarises the sampling results. Samples were analysed for all types of aquatic organisms including bacteria. The results may be considered as background information for an initial risk assessment of future species introductions - an important tool for the implementation of ballast water management measures.  相似文献   

12.
Transport of ballast water is one major factor in the transmission of aquatic organisms, including pathogenic bacteria. The IMO-guidelines of the Convention for the Control and Management of Ships' Ballast Water and Sediments, states that ships are to discharge <1 CFU per 100 ml ballast water of toxigenic Vibrio cholerae, emphasizing the need to establish test methods. To our knowledge, there are no methods sensitive and rapid enough available for cholera surveillance of ballast water. In this study real-time PCR and NASBA methods have been evaluated to specifically detect 1 CFU/100ml of V. cholerae in ballast water. Ballast water samples spiked with V. cholerae cells were filtered and enriched in alkaline peptone water before PCR or NASBA detection. The entire method, including sample preparation and analysis was performed within 7 h, and has the potential to be used for analysis of ballast water for inspection and enforcement control.  相似文献   

13.
We investigated the effect of high power ultrasound, at a frequency of 19 kHz, on the survival of bacteria, phytoplankton and zooplankton, in order to obtain estimates of effective exposure times and energy densities that could be applied to design of ultrasonic treatment systems for ballast water. Efficacy of ultrasonic treatment varied with the size of the test organism. Zooplankton required only 3-9s of exposure time and 6-19 J/mL of ultrasonic energy to realize a 90% reduction in survival. In contrast, decimal reduction times for bacteria and phytoplankton ranged from 1 to 22 min, and decimal reduction energy densities from 31 to 1240 J/mL. Our results suggest that stand-alone ultrasonic treatment systems for ballast water, operating at 19-20 kHz, may be effective for planktonic organisms >100 microm in size, but smaller planktonic organisms such as phytoplankton and bacteria will require treatment by an additional or alternative system.  相似文献   

14.
A prominent vector of aquatic invasive species to coastal regions is the discharge of water, sediments, and biofilm from ships' ballast-water tanks. During eight years of studying ships arriving to the lower Chesapeake Bay, we developed an understanding of the mechanisms by which invasive microorganisms might arrive to the region via ships. Within a given ship, habitats included ballast water, unpumpable water and sediment (collectively known as residuals), and biofilms formed on internal surfaces of ballast-water tanks. We sampled 69 vessels arriving from foreign and domestic ports, largely from Western Europe, the Mediterranean region, and the US East and Gulf coasts. All habitats contained bacteria and viruses. By extrapolating the measured concentration of a microbial metric to the estimated volume of ballast water, biofilm, or residual sediment and water within an average vessel, we calculated the potential total number of microorganisms contained by each habitat, thus creating a hierarchy of risk of delivery. The estimated concentration of microorganisms was greatest in ballast water>sediment and water residuals>biofilms. From these results, it is clear microorganisms may be transported within ships in a variety of ways. Using temperature tolerance as a measure of survivability and the temperature difference between ballast-water samples and the water into which the ballast water was discharged, we estimated 56% of microorganisms could survive in the lower Bay. Extrapolated delivery and survival of microorganisms to the Port of Hampton Roads in lower Chesapeake Bay shows on the order of 10(20) microorganisms (6.8 x 10(19) viruses and 3.9 x 10(18) bacteria cells) are discharged annually to the region.  相似文献   

15.
The invasion of biological organisms via ballast water has created threats to the environment and human health. In this study, a cost-effective electrochemical disinfection reactor was developed to inactivate Escherichia coli, one of the IMO-regulated indicator microbes, in simulated ballast water. The complete inactivation of E. coli could be achieved within a very short time (150, 120, or 60 s) with an energy consumption as low as 0.0090, 0.0074 or 0.0035 kWh/m(3) for ballast water containing E. coli at concentrations of 10(8), 10(7) and 10(6) CFU/100 mL, respectively. Electrochemical chlorination was the major disinfection mechanism in chloride-abundant electrolytes, whereas oxidants such as ozone and free radicals contributed to 20% of the disinfection efficiency in chloride-free electrolytes. Moreover, a disinfection kinetics model was successfully developed to describe the inactivation of E. coli.  相似文献   

16.
Exotic species introductions to the North American Great Lakes have continued even though ballast water management strategies were implemented in the early 1990s. Overseas vessels that arrive with little or no exchangeable ballast on board have been suspected to be an important source for discharging low salinity ballast containing low salinity tolerant organisms in this region. Residual ballast averaged 18.1+/-13.4 per thousand salinity among 62 samples taken primarily from bottom tanks on 26 vessels that entered the Great Lakes in 1999 and 2000. Sampling of 2-4 tanks each on nine vessels indicated all carried at least one tank of residual ballast of 相似文献   

17.
This study investigated the potential for transport of organisms between Hobart, Macquarie Island and the Antarctic continent by ships used in support of Antarctic science and tourism. Northward transport of plankton in ballast water is more likely than southward transport because ballast is normally loaded in the Antarctic and unloaded at the home port. Culturing of ballast water samples revealed that high-latitude hitchhikers were able to reach greater diversities when cultured at temperate thermal conditions than at typical Southern Ocean temperatures, suggesting the potential for establishment in the Tasmanian coastal environment. Several known invasive species were identified among fouling communities on the hulls of vessels that travel between Hobart and the Southern Ocean. Southward transport of hull fouling species is more likely than northward transport due to the accumulation of assemblages during the winter period spent in the home port of Hobart. This study does not prove that non-indigenous marine species have, or will be, transported and established as a consequence of Antarctic shipping but illustrates that the potential exists. Awareness of the potential risk and simple changes to operating procedures may reduce the chance of introductions in the future.  相似文献   

18.
Uptake and release of ship-borne ballast water is a major factor contributing to introductions of aquatic phytoplankton and invasive macroinvertebrates. Some invasive unicellular algae can cause harmful algal blooms and produce toxins that build up in food chains. Moreover, to date, few studies have compared the efficacy of ballast water treatments against different life history phases of aquatic macroinvertebrates. In the present study, the unicellular green alga Dunaliella tertiolecta, and three discrete life history phases of the brine shrimp Artemia salina, were independently used as model organisms to study the efficacy of sonication as well as the advanced oxidants, hydrogen peroxide and ozone, as potential ballast water treatments. Algal cells and brine shrimp cysts, nauplii, and adults were subjected to individual and combined treatments of sonication and advanced oxidants. Combined rather than individual treatments consistently yielded the highest levels of mortality in algal cells (100% over a 2 min exposure) and in brine shrimp (100% and 95% for larvae and adults, respectively, over a 2 min exposure). In contrast, mortality levels in brine shrimp cysts (66% over 2 min; increased to 92% over a 20 min exposure) were moderately high but consistently lower than that detected for larval or adult shrimp. Our results indicate that a combination of sonication and advanced chemical oxidants may be a promising method to eradicate aquatic unicellular algae and macroinvertebrates in ballast water.  相似文献   

19.
We examined methods for verifying whether or not ships have performed mid-ocean ballast water exchange (BWE) on four commercial vessels operating in the Pacific and Atlantic Oceans. During BWE, a ship replaces the coastal water in its ballast tanks with water drawn from the open ocean, which is considered to harbor fewer organisms capable of establishing in coastal environments. We measured concentrations of several naturally occurring chemical tracers (salinity, six trace elements, colored dissolved organic matter fluorescence and radium isotopes) along ocean transects and in ballast tanks subjected to varying degrees of BWE (0-99%). Many coastal tracers showed significant concentration changes due to BWE, and our ability to detect differences between exchanged and unexchanged ballast tanks was greatest under multivariate analysis. An expanded dataset, which includes additional geographic regions, is now needed to test the generality of our results.  相似文献   

20.
Observations are presented on dilution and dispersion rates of ballast water discharged under normal operational conditions at the semi-enclosed port of Goderich, Ontario. The ballast water was tagged with Rhodamine-WT dye and microscopic magnetically-attractive tracer particles. Maximum concentrations of dye immediately after discharge were diluted to 1-5% of initial ballast tank concentrations, and within 3 days had decreased to less than 0.1% of initial concentrations. Inside the harbor, there was 10-20% of the ballast water still present after 2 days, consistent with a flushing rate of 0.8-1.15 day−1. Magnetic particles were collected up to 7.5 km outside the harbor after one day, consistent with a dilution factor of order 105 outside the harbor. The results of this study are discussed in the context of ballast water discharge standards proposed by the International Maritime Organization to minimize the introduction of aquatic nonindigenous species through ships’ ballast water and sediments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号