共查询到3条相似文献,搜索用时 15 毫秒
1.
We measured the surface energy budget of an Alpine grassland in highly complex terrain to explore possibilities and limitations
for application of the eddy-covariance technique, also for CO2 flux measurements, at such non-ideal locations. This paper focuses on the influence of complex terrain on the turbulent energy
measurements of a characteristic high Alpine grassland on Crap Alv (Alp Weissenstein) in the Swiss Alps during the growing
season 2006. Measurements were carried out on a topographic terrace with a slope of 25◦ inclination. Flux data quality is assessed via the closure of the energy budget and the quality flag method used within the
CarboEurope project. During 93% of the time the wind direction was along the main valley axis (43% upvalley and 50% downvalley
directions). During the transition times of the typical twice daily wind direction changes in a mountain valley the fraction
of high and good quality flux data reached a minimum of ≈50%, whereas during the early afternoon ≈70% of all records yielded
good to highest quality (CarboEurope flags 0 and 1). The overall energy budget closure was 74 ± 2%. An angular correction
for the shortwave energy input to the slope improved the energy budget closure slightly to 82 ± 2% for afternoon conditions.
In the daily total, the measured turbulent energy fluxes are only underestimated by around 8% of net radiation. In summary,
our results suggest that it is possible to yield realistic energy flux measurements under such conditions. We thus argue that
the Crap Alv site and similar topographically complex locations with short-statured vegetation should be well suited also
for CO2 flux measurements. 相似文献
2.
Eddy correlation measurements of CO2, latent heat,and sensible heat fluxes over a crop surface 总被引:14,自引:0,他引:14
Eddy correlation equipment was used to measure mass and energy fluxes over a soybean crop. A rapid response CO2 sensor, a drag anemometer, a Lyman-alpha hygrometer and a fine wire thermocouple were used to sense the fluctuating quantities.Diurnal fluxes of sensible heat, latent heat and CO2 were calculated from these data. Energy budget closure was obtained by summing the sensible and latent heat fluxes determined by eddy correlation which balanced the sum of net radiation and soil heat flux. Peak daytime CO2 fluxes were near 1.0 mg m–2 (ground area) s–1.The eddy correlation technique was also employed in this study to measure nocturnal CO2 fluxes caused by respiration from plants, soil, and roots. These CO2 fluxes ranged from - 0.1 to - 0.25 mg m–2s–1.From the data collected over mature soybeans, a relationship between CO2 flux and photosynthetically active radiation (PAR) was developed. The crop did not appear to be light-saturated at PAR flux densities < 1800 Ei m–2 s–1. The light compensation point was found to be about 160 Ei m–2 s–1.Published as Paper No. 7402, Journal Series, Nebraska Agricultural Experiment Station. The work reported here was conducted under Nebraska Agricultural Experiment Station Project 27-003 and Regional Research Project 11–33.Post-doctoral Research Associate, Professor and Professor, respectively. Center for Agricultural Meteorology and Climatology, Institute of Agriculture and Natural Resources, University of Nebraska, Lincoln, NE 68583-0728. 相似文献
3.
Matthias Mauder Steven P. Oncley Roland Vogt Tamas Weidinger Luis Ribeiro Christian Bernhofer Thomas Foken Wim Kohsiek Henk A. R. De Bruin Heping Liu 《Boundary-Layer Meteorology》2007,123(1):29-54
The eddy-covariance method is the primary way of measuring turbulent fluxes directly. Many investigators have found that these
flux measurements often do not satisfy a fundamental criterion—closure of the surface energy balance. This study investigates
to what extent the eddy-covariance measurement technology can be made responsible for this deficiency, in particular the effects
of instrumentation or of the post-field data processing. Therefore, current eddy-covariance sensors and several post-field
data processing methods were compared. The differences in methodology resulted in deviations of 10% for the sensible heat
flux and of 15% for the latent heat flux for an averaging time of 30 min. These disparities were mostly due to different sensor
separation corrections and a linear detrending of the data. The impact of different instrumentation on the resulting heat
flux estimates was significantly higher. Large deviations from the reference system of up to 50% were found for some sensor
combinations. However, very good measurement quality was found for a CSAT3 sonic together with a KH20 krypton hygrometer and
also for a UW sonic together with a KH20. If these systems are well calibrated and maintained, an accuracy of better than
5% can be achieved for 30-min values of sensible and latent heat flux measurements. The results from the sonic anemometers
Gill Solent-HS, ATI-K, Metek USA-1, and R.M. Young 81000 showed more or less larger deviations from the reference system.
The LI-COR LI-7500 open-path H2O/CO2 gas analyser in the test was one of the first serial numbers of this sensor type and had technical problems regarding direct
solar radiation sensitivity and signal delay. These problems are known by the manufacturer and improvements of the sensor
have since been made.
The National Center for Atmospheric Research is supported by the National Science Foundation. 相似文献