首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This paper presents the correlation of the results of a new model for the dynamic analysis of reinforced concrete (RC) frames with the experimental time history of a two storey RC frame shaking-table specimen. The frame member model consists of separate subelements that describe the deformations due to flexure, shear and bond slip in RC structural elements. The subelements are combined by superposition of flexibility matrices to form the frame element. A non-linear solution method which accounts for the unbalance of internal forces between different subelements during a given load increment is used with the model. The ability of the proposed model to describe the dynamic response of frame structures under earthquake excitations is evaluated by comparing the analytical results with experimental evidence from a two-storey, one bay reinforced concrete frame tested on the shaking-table. The model parameters for the shaking-table specimen are derived from available experimental evidence and first principles of reinforced concrete. The effect of reinforcing bar slip on the local and global dynamic response of the test structure is assessed. © 1997 John Wiley & Sons, Ltd.  相似文献   

2.
张家广  吴斌  梅洋 《地震学刊》2014,(5):637-642
提出了一种既有钢筋混凝土框架结构的抗震加固方法,该法采用防屈曲支撑提高框架结构体系的水平承载力和耗能能力,利用外包钢进一步提高柱子的抗弯和抗剪承载力。采用开源有限元程序OpenSees,分别建立空钢筋混凝土框架和防屈曲支撑加固钢筋混凝土框架的分析模型,对2榀钢筋混凝土框架的抗震性能进行模拟。防屈曲支撑采用了弹塑性桁架单元模型,加固框架柱混凝土考虑了外包钢的约束作用。将分析结果与拟静力试验结果进行比较,以检验分析模型的准确性,以及研究防屈曲支撑和外包钢对混凝土框架抗震性能的影响。分析结果表明,数值模拟与试验结果吻合较好,验证了基于OpenSees建立的数值模型的准确性;外包钢有效改善了框架柱的抗弯承载力和变形能力;防屈曲支撑显著提高了加固框架体系的水平刚度、水平承载力和耗能能力。  相似文献   

3.
In this study life‐cycle cost (LCC) assessment of structural frames is performed. Two different materials, reinforced concrete (RC) and reinforced engineered cementitious composites (ECC), with different response characteristics are used to model the frames. ECC is characterized by high tensile ductility and energy absorption and reduced crack widths when compared to conventional concrete. However, the material is more expensive than conventional concrete; therefore, in order to quantify the potential benefits that could be obtained by replacing concrete with ECC, the life‐cycle performance is evaluated in an optimization framework. Three different structural frames are considered: an RC only frame, an ECC only frame and a multi‐material (MX) frame in which ECC is selectively applied at the potential plastic hinge locations while the remainder of the frame is made of RC. The structural capacity and earthquake demand are evaluated using rigorous analysis methods to capitalize on different characteristics of concrete and ECC, and both aleatory and epistemic uncertainties are incorporated into the LCC formulation. It is found that both the initial and LCC of frames that use ECC are lower due to savings in material and labor cost of transverse reinforcement for the former and due to increased capacity and reduced demand for the latter. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
Passive energy dissipation devices are increasingly implemented in frame structures to improve their performance under seismic loading. Most guidelines for designing this type of system retain the requirements applicable to frames without dampers, and this hinders taking full advantage of the benefits of implementing dampers. Further, assessing the extent of damage suffered by the frame and by the dampers for different levels of seismic hazard is of paramount importance in the framework of performance‐based design. This paper presents an experimental investigation whose objectives are to provide empirical data on the response of reinforced concrete (RC) frames equipped with hysteretic dampers (dynamic response and damage) and to evaluate the need for the frame to form a strong column‐weak beam mechanism and dissipate large amounts of plastic strain energy. To this end, shake‐table tests were conducted on a 2/5‐scale RC frame with hysteretic dampers. The frame was designed only for gravitational loads. The dampers provided lateral strength and stiffness, respectively, three and 12 times greater than those of the frame. The test structure was subjected to a sequence of seismic simulations that represented different levels of seismic hazard. The RC frame showed a performance level of ‘immediate occupancy’, with maximum rotation demands below 20% of the ultimate capacity. The dampers dissipated most of the energy input by the earthquake. It is shown that combining hysteretic dampers with flexible reinforced concrete frames leads to structures with improved seismic performance and that requirements of conventional RC frames (without dampers) can be relieved. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
Mild steel is relatively low-cost and easily accessible material to fabricate some structural members. It would be a significant advantage if seismic energy dissipaters that are used in structures constructed in the earthquake prone areas, could also be produced on site. In this paper, a promising seismic energy dissipater made of mild steel, so-called steel cushion (SC) is presented. It is provided experimental and analytical responses of SCs subjected to bi-axial loadings. SC rolls under the lateral loading that allows relocation of the plasticized cross-section. Henceforth, SC dissipates considerable amount of seismic energy. A series of tests were performed to achieve experimentally the behavior of SC subjected to longitudinal and transversal loading. Finite Element Models (FEMs) were also generated to reproduce the experimental backbone curves and to predict the bi-directional response properties for discrete transversal forces and plate thicknesses. Closed-form equations were derived to determine yield and ultimate forces and the corresponding displacements as well as location of the plasticized sections. The behavior of SC could either be projected by the FEMs with the exhibited parameters or by means of the proposed closed-form equations and the normalized design chart.  相似文献   

6.
In this study the inelastic behavior of steel arch bridges subjected to strong ground motions from major earthquakes is investigated by dynamic analyses of a typical steel arch bridge using a three‐dimensional (3D) analytical model, since checking seismic performance against severe earthquakes is not usually performed when designing such kinds of bridge. The bridge considered is an upper‐deck steel arch bridge having a reinforced concrete (RC) deck, steel I‐section girders and steel arch ribs. The input ground motions are accelerograms which are modified ground motions based on the records from the 1995 Hyogoken‐Nanbu earthquake. Both the longitudinal and transverse dynamic characteristics of the bridge are studied by investigation of time‐history responses of the main parameters. It is found that seismic responses are small when subjected to the longitudinal excitation, but significantly large under the transverse ground motion due to plasticization formed in some segments such as arch rib ends and side pier bases where axial force levels are very high. Finally, a seismic performance evaluation method based on the response strain index is proposed for such steel bridge structures. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

7.
Recent major earthquakes around the world have evidenced that research in earthquake engineering must be directed to the vulnerability assessment of existing constructions lacking appropriate seismic resisting characteristics. Their retrofit or replacement should be made in order to reduce vulnerability, and consequent risk, to currently accepted levels. In this work, the efficiency of ductile steel eccentrically-braced systems in the seismic retrofitting of existing reinforced concrete (RC) buildings is studied. The retrofit technique studied consists in a bracing system with an energy dissipation device, designed to dissipate energy by shear deformation. The numerical model was calibrated with cyclic test results on a full-scale structure. The models used for the RC frame and masonry represent their real behavior and influence in the global structural response. The steel bracing system was modeled with strut rigid elements. The model for the energy dissipater device reproduces rigorously the behavior of the shear-link observed in the cyclic tests, namely in terms of shear, drift and energy dissipation. With the calibrated numerical model, a series of non-linear dynamic analyses were performed, for different earthquake input motions, intending to study: the influence of the retrofitting system in the response of bare and infilled structures; the influence of the location and strength of the retrofitting system.  相似文献   

8.
Since most current seismic capacity evaluations of reinforced concrete(RC) frame structures are implemented by either static pushover analysis(PA) or dynamic time history analysis,with diverse settings of the plastic hinges(PHs) on such main structural components as columns,beams and walls,the complex behavior of shear failure at beam-column joints(BCJs) during major earthquakes is commonly neglected.This study proposes new nonlinear PA procedures that consider shear failure at BCJs and seek to assess the actual damage to RC structures.Based on the specifications of FEMA-356,a simplified joint model composed of two nonlinear cross struts placed diagonally over the location of the plastic hinge is established,allowing a sophisticated PA to be performed.To verify the validity of this method,the analytical results for the capacity curves and the failure mechanism derived from three different full-size RC frames are compared with the experimental measurements.By considering shear failure at BCJs,the proposed nonlinear analytical procedures can be used to estimate the structural behavior of RC frames,including seismic capacity and the progressive failure sequence of joints,in a precise and effective manner.  相似文献   

9.
增大柱端抗弯承载力是抗震"能力设计"措施中引导钢筋混凝土框架结构形成梁铰型有利耗能机构的关键措施。本文以6层确定性钢筋混凝土框架结构为分析对象,通过结构易损性分析评估了不同强柱系数取值对钢筋混凝土框架结构抗震性能的影响。结构易损性分析表明增大柱端抗弯承载力是改善结构抗震性能的有效措施,增大强柱系数提高了结构的变形能力,使不同破坏极限状态之间形成较大的"梯度",对防止强烈地震作用下结构的突然倒塌提供了预示。结构易损性曲线对评估结构抗震性能、选用合适的目标强柱系数提供了量化标准。  相似文献   

10.
为合理反映钢筋锈蚀后黏结滑移性能劣化对钢筋混凝土(RC)结构抗震性能的影响,在既有黏结应力分布模式的基础上,推导得到钢筋应力-滑移关系,进而通过分析锈蚀对混凝土与钢筋界面黏结滑移机理的影响,建立考虑钢筋锈蚀损伤的黏结滑移本构模型。基于已有拉拔试验结果,与仅考虑纵筋锈蚀率影响的Cheng模型进行对比,验证所建模型的合理性与准确性。基于OpenSees有限元平台,采用纤维梁柱单元和零长度截面单元串联的方式,将所建钢筋黏结滑移模型嵌套于零长度截面单元的钢筋本构中,建立可考虑黏黏结滑移的锈蚀损伤纤维梁柱模型,并通过6根锈蚀RC柱拟静力试验结果验证模型的准确性,结果发现所提考虑黏结滑移的锈蚀RC纤维梁柱模型计算所得滞回曲线与试验滞回曲线吻合良好,累计耗能最大误差不超过15%。此外,通过参数分析研究影响锈蚀钢筋滑移量的因素,结果表明屈服滑移量与极限滑移量随体积配箍率的增大而明显减小,随混凝土保护层与钢筋直径之比(c/d)增大而变化的幅度较小。  相似文献   

11.
This paper presents a new type of structural bracing intended for seismic retrofitting use in framed structures. This special composite brace,termed glass-fiber-reinforced-polymer(GFRP)-tube-confined-concrete composite brace,is comprised of concrete confined by a GFRP tube and an inner steel core for energy dissipation.Together with a contribution from the GFRP-tube confined concrete,the composite brace shows a substantially increased stiffness to control story drift, which is often a preferred feature in seismic retrofitting.An analysis model is established and implemented in a general finite element analysis program-OpenSees,for simulating the load-displacement behavior of the composite brace.Using this model,a parametric study of the hysteretic behavior(energy dissipation,stiffness,ductility and strength)of the composite brace was conducted under static cyclic loading and it was found that the area ratio of steel core to concrete has the greatest influence among all the parameters considered.To demonstrate the application of the composite brace in seismic retrofitting, a three-story nonductile reinforced concrete(RC)frame structure was retrofitted with the composite braces.Pushover analysis and nonlinear time-history analyses of the retrofitted RC frame structure was performed by employing a suite of 20 strong ground motion earthquake records.The analysis results show that the composite braces can effectively reduce the peak seismic responses of the RC frame structure without significantly increasing the base shear demand.  相似文献   

12.
13.
The damage to the masonry-infilled reinforced concrete (RC) frame buildings in Charikot, the capital city of Dolakha district in Nepal, during the 2015 April-to-May Nepal earthquake sequence is reported. Most of these buildings were built by the owners with little governmental inspections regarding their structural design or constructional quality. Although they generally performed better than other structural systems such as stone-masonry houses, the RC frames sustained extensive damage ranging from cracking of infill to complete collapse. In particular, eight of the 72 inspected RC frames alongside an uphill street collapsed in different ways. In addition to the un-engineered nature of these RC frames, their collapse could also be attributed to multiple technical reasons including the effect of terrain, the pounding between adjacent buildings and the accumulative damage in the earthquake sequence.  相似文献   

14.
SRC-RC竖向混合结构过渡层抗震设计方法探讨   总被引:4,自引:0,他引:4  
首先介绍了SRC-RC竖向混合结构的受力特点和性能优势;并针对我国和日本的相关规程及工程应用实践,结合日本阪神地震中SRC-RC竖向混合结构的主要震害特点,指出国内外SRC-RC竖向混合结构过渡层抗震设计方法所存在的主要问题及不足。在综合分析阪神地震后日本关于SRC-RC竖向混合结构过渡层抗震设计方法的最新研究进展的基础上,提出了SRC-RC竖向混合结构过渡层抗震设计的设计思路和方法,可为SRC-RC竖向混合结构过渡层抗震设计提供参考。  相似文献   

15.
Self‐centering reinforced concrete frames are developed as an alternative of traditional seismic force‐resisting systems with better seismic performance and re‐centering capability. This paper presents an experimental and computational study on the seismic performance of self‐centering reinforced concrete frames. A 1/2‐scale model of a two‐story self‐centering reinforced concrete frame model was designed and tested on the shaking table in State Key Laboratory of Disaster Reduction in Civil Engineering at Tongji University to evaluate the seismic behavior of the structure. A structural analysis model, including detailed modeling of beam–column joints, column–base joints, and prestressed tendons, was constructed in the nonlinear dynamic modeling software OpenSEES. Agreements between test results and numerical solutions indicate that the designed reinforced concrete frame has satisfactory seismic performance and self‐centering capacity subjected to earthquakes; the self‐centering structures can undergo large rocking with minor residual displacement after the earthquake excitations; the proposed analysis procedure can be applied in simulating the seismic performance of self‐centering reinforced concrete frames. To achieve a more comprehensive evaluation on the performance of self‐centering structures, research on energy dissipation devices in the system is expected. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
梁丹  梁兴文 《地震工程学报》2015,37(4):1060-1065,1072
选取按照现行规范设计的既有建筑进行有限元建模,考虑地震动的不确定性对其进行大量增量动力分析(IDA),得到模型的IDA曲线簇。在此基础上对其进行地震需求概率分析和概率抗震能力分析,拟合得到结构的易损性曲线,据此对结构的倒塌概率进行定量评估,并比较基于非线性分析与性能评估软件PERFORM-3D的纤维模型和塑性铰模型的分析结果。结果表明:按照我国现行规范设计的钢筋混凝土(RC)框架结构,在预期的罕遇地震作用下倒塌概率较小,可满足"大震不倒"的要求;基于PERFORM-3D的截面纤维模型所得的RC框架结构,经非线性分析所得的倒塌概率相对保守,安全储备更高。  相似文献   

17.
为研究施工缝对框架结构抗震性能的影响,利用提出的施工缝模型,基于OPENSEES平台建模进行静力非线性分析和非线性动力时程分析。通过对比整浇框架与带缝框架的顶点最大位移、层间位移角、塑性铰出现和分布规律等明确施工缝对框架结构的抗震性能的影响程度。结果表明,施工缝使框架结构的变形和层间位移角显著增大,并且使8、9度区框架结构的层间位移角分布发生改变;施工缝使柱端更易出现塑性铰,更易发生"强梁弱柱"的破坏模式;在高烈度区,施工缝的影响比较显著,如果忽略其影响,将会高估框架结构的抗震性能。  相似文献   

18.
内置钢板钢筋混凝土组合剪力墙具有良好的抗震性能,目前已在超高层建筑中得到越来越多的应用。采用OpenSees程序对普通钢筋混凝土剪力墙和钢板组合剪力墙试验构件进行模拟分析,验证了建模与分析方法的合理性与准确性,分析结果表明,该方法能够较好地模拟组合剪力墙的弹塑性行为。分析了轴压比和配钢率这两个关键参数对内置钢板组合剪力墙抗震性能的影响。计算结果表明,与普通钢筋混凝土剪力墙相比,内置钢板可以明显提高构件的承载力、延性和滞回耗能;轴压比和配钢率对组合剪力墙的抗震性能有较大影响。  相似文献   

19.
A nonlinear hysteretic model for the response and local damage analyses of reinforced concrete shear frames subject to earthquake excitation is proposed, and, the model is applied to analyse midbroken reinforced concrete (RC) structures due to earthquake loads. Each storey of the shear frame is represented by a Clough and Johnston hysteretic oscillator with degrading elastic fraction of the restoring force. The local damage is numerically quantified in the domain [0,1] using the maximum softening damage indicators which are defined in closed form based on the variation of the eigenfrequency of the local oscillators due to the local stiffness and strength deterioration. The proposed method of response and damage analyses is illustrated using a sample 5 storey shear frame with a weak third storey in stiffness and/or strength subject to sinusoidal and simulated earthquake excitations for which the horizontal component of the ground motion is modeled as a stationary Gaussian stochastic process with Kanai-Tajimi spectrum, multiplied by an envelope function.  相似文献   

20.
The 2009 L’Aquila, Italy earthquake highlighted the seismic vulnerability of historic masonry building structures due to improper "strengthening" retrofit work that has been done in the last 50 years. Italian seismic standards recommend the use of traditional reinforcement techniques such as replacing the original wooden roof structure with new reinforced concrete (RC) or steel elements, inserting RC tie-beams in the masonry and new RC floors, and using RC jacketing on the shear walls. The L’Aquila earthquake revealed the numerous limitations of these interventions, because they led to increased seismic forces (due to greater additional weight) and to deformation incompatibilities of the incorporated elements with the existing masonry walls. This paper provides a discussion of technical issues pertaining to the seismic retrofit of the Santa Maria di Collemaggio Basilica and in particular, the limitations of the last (2000) retrofit intervention. Considerable damage was caused to the church because of questionable actions and incorrect and improper technical choices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号