首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
1,4‐Dioxane is a volatile organic compound that is fully miscible in water, allowing it to sequester in vadose zone pore water and serve as a long‐term source of groundwater contamination. Conventional soil vapor extraction (SVE) removes 1,4‐dioxane; however, substantial 1,4‐dioxane can remain even after other colocated chlorinated solvents have been remediated. A field demonstration of “enhanced SVE” (XSVE) with focused extraction and heated injection was conducted at former McClellan AFB, CA, achieving 94% reduction in soil concentrations. A screening‐level tool, HypeVent XSVE, was created to assist in system design and data reduction and to anticipate how operating factors affect XSVE performance (e.g., cleanup level, remediation time, etc.). It assumes well‐mixed conditions, and combines an energy balance, mass balances for water and contaminant, and a temperature‐dependent 1,4‐dioxane Henry's Law constant. User inputs include the target treatment zone size, initial 1,4‐dioxane and soil moisture concentrations, and ambient site and injection/extraction conditions (temperature, humidity). Projections based on inputs representative of demonstration site conditions adequately anticipated the observed macroscopic field results. Sensitivity analyses show that removal increases with increasing heated air injection temperature and relative humidity and decreasing initial soil moisture content.  相似文献   

2.
Soil gas sampling for 1,4‐dioxane at elevated soil temperatures, such as those experienced during in‐situ thermal treatment, has the potential to yield low results due to condensation of water vapor in the ambient temperature sampling vessel and the partitioning of 1,4‐dioxane into that condensate. A simple vapor/condensate sampling apparatus was developed to collect both condensate and vapor samples to allow for determination of a reconstituted effective soil gas concentration for 1,4‐dioxane. Results using the vapor/condensate sampling apparatus during a heated air injection SVE field demonstration are presented, along with those of a comparable laboratory system. Substantial 1,4‐dioxane mass was found in the condensate in both the lab and field (as high as ~50% in field). As soil temperatures increased, less 1,4‐dioxane mass was detected in field condensate samples than expected based on laboratory experiments. Extraction well effluent sampling at the wellhead by direct vapor canister sampling provided erratic results (several biased low by a factor of 5 or more) compared to those of the vapor/condensate apparatus. Direct vapor canister sampling of extraction well effluent after the air‐water separator, however, provided results reasonably comparable (within 35%) to those using the vapor/condensate apparatus at the wellhead. Soil gas sampling at elevated temperatures using the vapor/condensate apparatus alleviates potential low sampling bias due to condensation.  相似文献   

3.
At a utility service center, gasoline from an underground storage tank had leaked into subsurface vadose zone soils for several years. To remediate the site, a soil vapor extraction (SVE) system was installed and operated. At the completion of the SVE operation, gasoline-containing residues in several confirmation soil borings exceeded agency-mandated cleanup levels. Rather than continue with SVE, a risk-based approach was developed to evaluate what levels of gasoline-containing residues could be left in the soil and still protect human health. The risk-based approach consisted of simulating the fate of chemical residues through the vadose zone and then into both the ground water and atmosphere. Receptor point concentrations were predicted, and health risks were assessed. The risk assessment concluded that ingestion of contaminated ground water and inhalation of air while showering were the largest potential contributors to risk, and that risks associated with inhalation of vapor-containing ambient air are small. However, all predicted risks are below the acceptable risk levels of 10−6 individual cancer risk probability and 1.0 hazard index. Therefore, the lead agency accepted the recommendation that the site requires no further remediation. The service center continues normal operations today.  相似文献   

4.
Vapor extraction (soil venting) has been demonstrated to be a successful and cost-effective remediation technology for removing VOCs from the vadose (unsaturated) zone. However, in many cases, seasonal water table fluctuations, drawdown associated with pump-and-treat remediation techniques, and spills involving dense, non-aqueous phase liquids (DNAPLS) create contaminated soil below the water table. Vapor extraction alone is not considered to be an optimal remediation technology to address this type of contamination.
An innovative approach to saturated zone remediation is the use of sparging (injection) wells to inject a hydrocarbon-free gaseous medium (typically air) into the saturated zone below the areas of contamination. The contaminants dissolved in the ground water and sorbed onto soil particles partition into the advective air phase, effectively simulating an in situ air-stripping system. The stripped contaminants are transported in the gas phase to the vadose zone, within the radius of influence of a vapor extraction and vapor treatment system.
In situ air sparging is a complex multifluid phase process, which has been applied successfully in Europe since the mid-1980s. To date, site-specific pilot tests have been used to design air-sparging systems. Research is currently underway to develop better engineering design methodologies for the process. Major design parameters to be considered include contaminant type, gas injection pressures and flow rates, site geology, bubble size, injection interval (areal and vertical) and the equipment specifications. Correct design and operation of this technology has been demonstrated to achieve ground water cleanup of VOC contamination to low part-per-billion levels.  相似文献   

5.
Diminishing rates of subsurface volatile contaminant removal by soil vapor extraction (SVE) oftentimes warrants an in-depth performance assessment to guide remedy decision-making processes. Such a performance assessment must include quantitative approaches to better understand the impact of remaining vadose zone contamination on soil gas and groundwater concentrations. The spreadsheet-based Soil Vapor Extraction Endstate Tool (SVEET) software functionality has recently been expanded to facilitate quantitative performance assessments. The updated version, referred to as SVEET2, includes expansion of the input parameter ranges for describing a site (site geometry, source characteristics, etc.), an expanded list of contaminants, and incorporation of elements of the Vapor Intrusion Estimation Tool for Unsaturated-zone Sources software to provide soil gas concentration estimates for use in vapor intrusion evaluation. As part of the update, SVEET2 was used to estimate the impact of a tetrachloroethene (PCE) vadose zone source on groundwater concentrations, comparing SVEET2 results to field-observed values at an undisclosed site where SVE was recently terminated. PCE concentrations from three separate monitoring wells were estimated by SVEET2 to be within the range of 6.0–6.7 μg/L, as compared to actual field concentrations that ranged from 3 to 11 μg/L PCE. These data demonstrate that SVEET2 can rapidly provide representative quantitative estimates of impacts from a vadose zone contaminant source at field sites. In the context of the SVE performance assessment, such quantitative estimates provide a basis to support remedial and/or regulatory decisions regarding the continued need for vadose zone volatile organic compound remediation or technical justification for SVE termination, which can significantly reduce the cost to complete for a site.  相似文献   

6.
Soil vapor extraction (SVE) is a prevalent remediation remedy for volatile organic compound (VOC) contaminants in the vadose zone. To support selection of an appropriate condition at which SVE may be terminated for site closure or for transition to another remedy, an evaluation is needed to determine whether vadose zone VOC contamination has been diminished sufficiently to keep groundwater concentrations below threshold values. A conceptual model for this evaluation was developed for VOC fate and transport from a vadose zone source to groundwater when vapor‐phase diffusive transport is the dominant transport process. A numerical analysis showed that, for these conditions, the groundwater concentration is controlled by a limited set of parameters, including site‐specific dimensions, vadose zone properties, and source characteristics. On the basis of these findings, a procedure was then developed for estimating groundwater concentrations using results from the three‐dimensional multiphase transport simulations for a matrix of parameter value combinations and covering a range of potential site conditions. Interpolation and scaling processes are applied to estimate groundwater concentrations at compliance (monitoring) wells for specific site conditions of interest using the data from the simulation results. The interpolation and scaling methodology using these simulation results provides a far less computationally intensive alternative to site‐specific three‐dimensional multiphase site modeling, while still allowing for parameter sensitivity and uncertainty analyses. With iterative application, the approach can be used to consider the effect of a diminishing vadose zone source over time on future groundwater concentrations. This novel approach and related simulation results have been incorporated into a user‐friendly Microsoft® Excel®‐based spreadsheet tool entitled SVEET (Soil Vapor Extraction Endstate Tool), which has been made available to the public.  相似文献   

7.
Effective long‐term operation of soil vapor extraction (SVE) systems for cleanup of vadose‐zone sources requires consideration of the likelihood that remediation activities over time will alter the subsurface distribution and configuration of contaminants. A method is demonstrated for locating and characterizing the distribution and nature of persistent volatile organic contaminant (VOC) sources in the vadose zone. The method consists of three components: analysis of existing site and SVE‐operations data, vapor‐phase cyclic contaminant mass‐discharge testing, and short‐term vapor‐phase contaminant mass‐discharge tests conducted in series at multiple locations. Results obtained from the method were used to characterize overall source zone mass‐transfer limitations, source‐strength reductions, potential changes in source‐zone architecture, and the spatial variability and extent of the persistent source(s) for the Department of Energy's Hanford site. The results confirmed a heterogeneous distribution of contaminant mass discharge throughout the vadose zone. Analyses of the mass‐discharge profiles indicate that the remaining contaminant source is coincident with a lower‐permeability unit at the site. Such measurements of source strength and size as obtained herein are needed to determine the impacts of vadose‐zone sources on groundwater contamination and vapor intrusion, and can support evaluation and optimization of the performance of SVE operations.  相似文献   

8.
This study looks at the influence of surface covers on the performance of a single pumping well system. Pilot tests were conducted on a sandy soil to determine the influence of surface confinement based upon both induced vacuum and pore gas velocity design criteria. The results demonstrate how covering the surface can significantly alter the associated air flow patterns and velocity distribution. Comparison of streamline iso‐contours obtained in covered scenarios reveals that the surface seal tended to prevent air from entering the subsurface near the extraction well and force air to be drawn from a greater distance. Calculated and measured pressure differentials, for open and semi‐confined scenarios, clearly show that adding a clay layer as a surface cover increased the vacuum induced within the soil. Pore gas velocity analysis showed that when the cover clay layer was used, the zone of capture of the soil vapor extraction system increased. The radius of influence of soil vapor extraction (SVE) systems, based on the attainment of a critical vacuum or pore gas velocity, can then be increased by including a surface seal in the design of such systems. The focus of this study is limited to air flow patterns contrasted between covered and uncovered conditions and not on the nuances of a full scale remediation implementation.  相似文献   

9.
Methods are developed to use data collected during cyclic operation of soil vapor extraction (SVE) systems to help characterize the magnitudes and time scales of mass flux associated with vadose zone contaminant sources. Operational data collected at the Department of Energy’s Hanford site are used to illustrate the use of such data. An analysis was conducted of carbon tetrachloride vapor concentrations collected during and between SVE operations. The objective of the analysis was to evaluate changes in concentrations measured during periods of operation and nonoperation of SVE, with a focus on quantifying temporal dynamics of the vadose zone contaminant mass flux, and associated source strength. Three mass flux terms, representing mass flux during the initial period of an SVE cycle, during the asymptotic period of a cycle, and during the rebound period, were calculated and compared. It was shown that it is possible to use the data to estimate time frames for effective operation of an SVE system if a sufficient set of historical cyclic operational data exists. This information could then be used to help evaluate changes in SVE operations, including system closure. The mass flux data would also be useful for risk assessments of the impact of vadose zone sources on groundwater contamination or vapor intrusion.  相似文献   

10.
Air sparging is a relatively new technique for the remediation of ground water contaminated with petroleum hydrocarbons. In this technique, air is injected below the water table, beneath the contaminated soil. Remediation occurs by a combination of contaminant partitioning into the vapor phase and enhanced biodegradation. The air is usually removed by vacuum extraction in the vadose zone.
The efficiency of remediation from air sparging is a function of the air flow pattern, although the distribution of the injected air is still poorly understood. Cross-borehole resistivity surveys were performed at a former service station in Florence, Oregon, to address this unknown. The resistivity measurements were made using six wells, one of which was the sparge well. Data were collected over a two-week period during and after several air injections, or sparge events. Resistivity images were calculated between wells using an algorithm that assumes axially symmetric structures. The movement of the injected air through time was defined by regions of large increases in resistivity, greater than 100 percent from the background. During early sparge times, air moved outward and upward from the injection point as it ascended to the unsaturated zone. At later sparge times, the air flow reached a somewhat stable cone-shaped pattern radiating out and up from the injection point. Two days after sparging was discontinued, a residue of entrained air remained in the saturated zone, as indicated by a zone of 60 to 80 percent water saturation.  相似文献   

11.
Site closure for soil vacuum extraction (SVE) application typically requires attainment or specified soil concentration standards based on the premise that mass flux from the vadose zone to ground water not result in levels exceeding maximum contaminant levels (MCLs). Unfortunately, realization of MCLs in ground water may not be attainable at many sites. This results in soil remediation efforts that may be in excess of what is necessary for future protection of ground water and soil remediation goals which often cannot be achieved within a reasonable time period. Soil venting practitioners have attempted to circumvent these problems by basing closure on some predefined percent total mass removal, or an approach to a vapor concentration asymptote. These approaches, however, are subjective and influenced by venting design. We propose an alternative strategy based on evaluation of five components: (1) site characterization, (2) design. (3) performance monitoring, (4) rule-limited vapor transport, and (5) mass flux to and from ground water. Demonstration of closure is dependent on satisfactory assessment of all five components. The focus of this paper is to support mass flux evaluation. We present a plan based on monitoring of three subsurface zones and develop an analytical one-dimensional vertical flux model we term VFLUX. VFLUX is a significant improvement over the well-known numerical one-dimensional model. VLEACH, which is often used for estimation of mass flux to ground water, because it allows for the presence of nonaqueous phase liquids (NAPLs) in soil, degradation, and a lime-dependent boundary condition at the water table inter-face. The time-dependent boundary condition is the center-piece of our mass flux approach because it dynamically links performance of ground water remediation lo SVE closure. Progress or lack of progress in ground water remediation results in either increasingly or decreasingly stringent closure requirements, respectively.  相似文献   

12.
Soil vapor extraction (SVE) is effective for removing volatile organic compound (VOC) mass from the vadose zone and reducing the potential for vapor intrusion (VI) into overlying and surrounding buildings. However, the relationship between residual mass in the subsurface and VI is complex. Through a series of alternating extraction (SVE on) and rebound (SVE off) periods, this field study explored the relationship and aspects of SVE applicable to VI mitigation in a commercial/light-industrial setting. The primary objective was to determine if SVE could provide VI mitigation over a wide area encompassing multiple buildings, city streets, and subsurface utilities and eliminate the need for individual subslab depressurization systems. We determined that SVE effectively mitigates offsite VI by intercepting or diluting contaminant vapors that would otherwise enter buildings through foundation slabs. Data indicate a measurable (5 Pa) influence of SVE on subslab/indoor pressure differential may occur but is not essential for effective VI mitigation. Indoor air quality improvements were evident in buildings 100 to 200 feet away from SVE including those without a measurable reversal of differential pressure across the slab or substantial reductions in subslab VOC concentration. These cases also demonstrated mitigation effects across a four-lane avenue with subsurface utilities. These findings suggest that SVE affects distant VI entry points with little observable impact on differential pressures and without relying on subslab VOC concentration reductions.  相似文献   

13.
The generation of vapor‐phase contaminant plumes within the vadose zone is of interest for contaminated site management. Therefore, it is important to understand vapor sources such as non‐aqueous‐phase liquids (NAPLs) and processes that govern their volatilization. The distribution of NAPL, gas, and water phases within a source zone is expected to influence the rate of volatilization. However, the effect of this distribution morphology on volatilization has not been thoroughly quantified. Because field quantification of NAPL volatilization is often infeasible, a controlled laboratory experiment was conducted in a two‐dimensional tank (28 cm × 15.5 cm × 2.5 cm) with water‐wet sandy media and an emplaced trichloroethylene (TCE) source. The source was emplaced in two configurations to represent morphologies encountered in field settings: (1) NAPL pools directly exposed to the air phase and (2) NAPLs trapped in water‐saturated zones that were occluded from the air phase. Airflow was passed through the tank and effluent concentrations of TCE were quantified. Models were used to analyze results, which indicated that mass transfer from directly exposed NAPL was fast and controlled by advective‐dispersive‐diffusive transport in the gas phase. However, sources occluded by pore water showed strong rate limitations and slower effective mass transfer. This difference is explained by diffusional resistance within the aqueous phase. Results demonstrate that vapor generation rates from a NAPL source will be influenced by the soil water content distribution within the source. The implications of the NAPL morphology on volatilization in the context of a dynamic water table or climate are discussed.  相似文献   

14.
A large-scale air sparging/soil vapor extraction (AS/SVE) project constructed within coastal plain sediments in New Jersey has demonstrated substantial progress toward remediating ground water through removal of volatile organic compounds (VOCs). Potential concerns identified prior to project implementation regarding hydraulic mounding, reduction in hydraulic conductivity, development of air channels, and the absence of hydraulic containment were assessed and addressed through testing and operational features incorporated into the project. At the project site, AS/SVE has successfully reduced the presence of many VOCs to undetectable levels, while reducing the concentrations of the remaining VOCs by factors of two to 500. The physical agitation caused by air sparging, and incomplete transformation from sorbed and nonaqueous phases to the vapor phase, appears to temporarily increase VOC concentrations and/or mobility of dense nonaqueous phase liquids (DN APLs) within source areas at the project site, but this is addressed in terms of subsequent removal of VOCs by properly placed downgradient treatment lines and VOCs by properly placed downgradient treatment lines and DNAPL recovery wells. This case study identifies and evaluates project-specific features and provides empirical data for potential comparison to other candidates AS/SVE sites.  相似文献   

15.
Soil vapor extraction (SVE) is widely used to remove volatile organic compounds from the vadose zone. Design of SVE systems rely largely upon vacuum responses and limited vapor concentration data measured during short-term soil gas extraction tests performed in single extraction wells. Interpretation of such vacuum data is often simply a rule of thumb as most field sites have layering complexity negating applicability of existing analytical models. This paper provides the derivation of an analytical model for steady, axisymmetric gas flow in heterogeneous (layered) soils from a single well. A general, variable flow boundary condition along the well screen represents actual conditions more closely than a uniform flow or uniform well pressure condition. Each soil layer is assumed homogeneous with anisotropic gas permeability. The solution is derived using the generalized integral transform technique and includes expressions for vacuum, velocities, and streamlines. The model is applied to the interpretation of multiple well tests at a field site and uses linear superposition to extend the flow model to multi-well extraction. The demonstration site included an array of vacuum monitoring data collected during nine individual well flow tests. A method of normalizing the vacuum data is illustrated that allowed the full data set to be employed in a single calibration effort. The test site also included a surface cap with an apparent vertical permeability two to three orders of magnitude smaller than the sands of the vadose zone. This large permeability contrast posed no difficulties in evaluating the solution.  相似文献   

16.
Propane biosparging and bioaugmentation were applied to promote in situ biodegradation of 1,4‐dioxane at Site 24, Vandenberg Air Force Base (VAFB), CA. Laboratory microcosm and enrichment culture testing demonstrated that although native propanotrophs appeared abundant in the shallow water‐bearing unit of the aquifer (8 to 23 ft below ground surface [bgs]), they were difficult to be enriched from a deeper water‐bearing unit (82 to 90 feet bgs). Bioaugmentation with the propanotroph Rhodococcus ruber ENV425, however, supported 1,4‐dioxane biodegradation in microcosms constructed with samples from the deep aquifer. For field testing, a propane‐biosparging system consisting of a single sparging well and four performance monitoring wells was constructed in the deep aquifer. 1,4‐dioxane biodegradation began immediately after bioaugmentation with R. ruber ENV425 (36 L; 4 × 109 cells/mL), and apparent first‐order decay rates for 1,4‐dioxane ranged from 0.021 day?1 to 0.036 day?1. First‐order propane consumption rates increased from 0.01 to 0.05 min?1 during treatment. 1,4‐dioxane concentrations in the sparging well and two of the performance monitoring wells were reduced from as high as 1090 µg/L to <2 µg/L, while 1,4‐dioxane concentration was reduced from 135 µg/L to 7.3 µg/L in a more distal third monitoring well. No 1,4‐dioxane degradation was observed in the intermediate aquifer control well even though propane and oxygen were present. The demonstration showed that propane biosparging and bioaugmentation can be used for in situ treatment of 1,4‐dioxane to regulatory levels.  相似文献   

17.
This paper presents a full‐scale thermal remediation of a brownfields site near San Francisco, California. In Situ Thermal Desorption (ISTD) was used for treatment of chlorinated solvents in a tight clay below the water table. The site had contaminants in concentrations indicating that a tetrachloroethene (PCE)‐rich DNAPL was present. A target volume of 5097 m3 of subsurface material to a depth of 6.2 m was treated for a period of 110 d of heating. Energy was delivered through 126 thermal conduction heater borings, and vapors were extracted from a combination of vertical and horizontal vacuum wells. Approximately 2540 kg of contaminants were recovered in the extracted vapors by the end of treatment. The PCE concentration in the clay was reduced from as high as 2700 mg/kg to an average concentration of 0.012 mg/kg within 110 d of heating (a reduction of >99.999%). Similar effectiveness was documented for TCE, cis‐1,2‐DCE, and vinyl chloride. A total of 2.2 million kWh of electric power was used to heat the site. Approximately 45% of this energy was used to heat the subsurface to the target temperature. Another 53% was necessary to boil approximately 41% of the groundwater within the treatment zone, creating approximately 600 pore volumes of steam by the end of the 110‐d heating and treatment period. Steam generation thus occurred within the clay. Partitioning of the contaminants into the steam and its removal comprised the dominant remedial mechanism. The steam migrated laterally toward the ISTD heaters, where it encountered a small dry region adjacent to each of the heaters, which served as a preferential pathway allowing the steam to migrate upward along the heaters to the more permeable vadose zone. There the steam was captured by a system of vertical and horizontal vacuum extraction wells. This vapor removal strategy facilitated effective thermal treatment of the tight clays located below the water table. Features of a robust design are extension of the heaters at least 1.2 m deeper than the treatment depth, and the installation of shallow horizontal vapor collection wells which allow for establishment of pneumatic control.  相似文献   

18.
Light non-aqueous phase liquids (LNAPL) represent one of the most serious problems in aquifers contaminated with petroleum hydrocarbons liquids. To design an appropriate remediation strategy it is essential to understand the behavior of the plume. The aim of this paper is threefold: (1) to characterize the fluid distribution of an LNAPL plume detected in a volcanic low-conductivity aquifer (∼0.4 m/day from slug tests interpretation), (2) to simulate the recovery processes of the free-product contamination and (3) to evaluate the primary recovery efficiency of the following alternatives: skimming, dual-phase extraction, Bioslurping and multi-phase extraction wells. The API/Charbeneau analytical model was used to investigate the recovery feasibility based on the geological properties and hydrogeological conditions with a multi-phase (water, air, LNAPL) transport approach in the vadose zone. The modeling performed in this research, in terms of LNAPL distribution in the subsurface, show that oil saturation is 7% in the air–oil interface, with a maximum value of 70% in the capillary fringe. Equilibrium between water and LNAPL phases is reached at a depth of 1.80 m from the air–oil interface. On the other hand, the LNAPL recovery model results suggest a remarkable enhancement of the free-product recovery when simultaneous extra-phase extraction was simulated from wells, in addition to the LNAPL lens. Recovery efficiencies were 27%, 65%, 66% and 67% for skimming, dual-phase extraction, Bioslurping and multi-phase extraction, respectively. During a 3-year simulation, skimmer wells and multi-phase extraction showed the lowest and highest LNAPL recovery rates, with expected values from 207 to 163 and 2305 to 707 l-LNAPL/day, respectively. At a field level we are proposing a well distribution arrangement that alternates pairs of dual-phase well-Bioslurping well. This not only improves the recovery of the free-product plume, but also pumps the dissolve plume and enhances in situ biodegradation in the vadose zone. Thus, aquifer and soil remediation can be achieved at a shorter time. Rough calculations suggest that LNAPL can be recovered at an approximate cost of $6–$10/l.  相似文献   

19.
This study evaluates the theory, and some practical aspects of using temperature measurements to assess aerobic biodegradation in hydrocarbon contaminated soil. The method provides an easily applicable alternative for quantifying the rate of biodegradation and/or evaluating the performance of in situ remediation systems. The method involves two nonintrusive procedures for measuring vertical temperature profiles down existing monitoring wells; one using a thermistor on a cable for one‐time measurements and the other using compact temperature data loggers deployed for 3‐month to 1‐year period. These vertical temperature profile measurements are used to identify the depth and lateral extent of biodegradation as well as to monitor seasonal temperature changes throughout the year. The basic theory for using temperature measurements to estimate the minimum rate of biodegradation will be developed, and used to evaluate field measurements from sites in California where biodegradation of spilled petroleum hydrocarbons is due to natural processes. Following, temperature data will be used to evaluate the relative rates of biodegradation due to natural processes and soil vapor extraction (SVE) at a former refinery site in the North‐Central United States. The results from this study show that the temperature method can be a simple, cost effective tool for assessing biodegradation in the soil, and optimizing remediation systems at a wide variety of hydrocarbon spill sites.  相似文献   

20.
A field tracer test was carried out in a light nonaqueous phase liquid (LNAPL) source zone using a well pattern consisting of one injection well surrounded by four extraction wells (5‐spot well pattern). Multilevel sampling was carried out in two observation wells located inside the test cell characterized by heterogeneous lithology. Tracer breakthrough curves showed relatively uniform flow within soil layers. A numerical flow and solute transport model was calibrated on hydraulic heads and tracer breakthrough curves. The model was used to estimate an average accessible porosity of 0.115 for the swept zone and an average longitudinal dispersivity of 0.55 m. The model was further used to optimize the relative effects of viscous forces versus capillary forces under realistic imposed hydraulic gradients and to establish optimal surfactant solution properties. Maximum capillary number (NCa) values between injection and extraction wells were obtained for an injection flow rate of 16 L/min, a total extraction flow rate of 20 L/min, and a surfactant solution with a viscosity of 0.005 Pa?s. The unconfined nature of the aquifer limited further flow rate or viscosity increases that would have led to unrealistic hydraulic gradients. An NCa range of 3.8 × 10?4 to 7.6 × 10?3 was obtained depending on the magnitude of the simulated LNAPL‐water interfacial tension reduction. Finally, surfactant and chase water slug sizing was optimized with a radial form of the simplified Ogata‐Banks analytical solution (Ogata and Banks 1961) so that injected concentrations could be maintained in the entire 5‐spot cell.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏