共查询到20条相似文献,搜索用时 13 毫秒
1.
Ario Ceccotti Carmen Sandhaas Minoru Okabe Motoi Yasumura Chikahiro Minowa Naohito Kawai 《地震工程与结构动力学》2013,42(13):2003-2021
Multi‐storey buildings made of cross‐laminated timber panels (X‐lam) are becoming a stronger and economically valid alternative in Europe compared with traditional masonry or concrete buildings. During the design process of these multi‐storey buildings, also their earthquake behaviour has to be addressed, especially in seismic‐prone areas such as Italy. However, limited knowledge on the seismic performance is available for this innovative massive timber product. On the basis of extensive testing series comprising monotonic and reversed cyclic tests on X‐lam panels, a pseudodynamic test on a one‐storey X‐lam specimen and 1D shaking table tests on a full‐scale three‐storey specimen, a full‐scale seven‐storey building was designed according to the European seismic standard Eurocode 8 and subjected to earthquake loading on a 3D shaking table. The building was designed with a preliminary action reduction factor of three that had been derived from the experimental results on the three‐storey building. The outcomes of this comprehensive research project called ‘SOFIE – Sistema Costruttivo Fiemme’ proved the suitability of multi‐storey X‐lam structures for earthquake‐prone regions. The buildings demonstrated self‐centring capabilities and high stiffness combined with sufficient ductility to avoid brittle failures. The tests provided useful information for the seismic design with force‐based methods as defined in Eurocode 8, that is, a preliminary experimentally based action reduction factor of three was confirmed. Valid, ductile joint assemblies were developed, and their importance for the energy dissipation in buildings with rigid X‐lam panels became evident. The seven‐storey building showed relatively high accelerations in the upper storeys, which could lead to secondary damage and which have to be addressed in future research. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
2.
This paper summarizes results of a comprehensive analytical study aimed at evaluating the amplitude and heightwise distribution of residual drift demands in multi‐storey moment‐resisting frames after earthquake excitation. For that purpose, a family of 12 one‐bay two‐dimensional generic frame models was subjected to an ensemble of 40 ground motions scaled to different intensities. In this investigation, an inelastic ground motion intensity measure was employed to scale each record, which allowed reducing the record‐to‐record variability in the estimation of residual drift demands. The results were statistically processed in order to evaluate the influence of ground motion intensity, number of stories, period of vibration, frame mechanism, system overstrength, and hysteretic behaviour on central tendency of residual drift demands. In addition, a special emphasis was given to evaluate the uncertainty in the estimation of residual drift demands. Results of incremental dynamic analyses indicate that the amplitude and heightwise distribution of residual drift demands strongly depends on the frame mechanism, the heightwise system structural overstrength and the component hysteretic behaviour. An important conclusion for performance‐based assessment is that the evaluation of residual drift demands involves significantly larger levels of uncertainty (i.e. record‐to‐record variability) than that of maximum drift demands, which suggests that this variability and corresponding uncertainty should be explicitly taken into account when estimating residual drift demands during performance‐based seismic assessment of frame buildings. Copyright © 2006 John Wiley & Sons, Ltd. 相似文献
3.
Swaminathan Krishnan 《地震工程与结构动力学》2007,36(7):861-885
This paper describes the three‐dimensional nonlinear analysis of six 19‐storey steel moment‐frame buildings, designed per the 1997 Uniform Building Code, under strong ground motion records from near‐source earthquakes with magnitudes in the range of 6.7–7.3. Three of these buildings possess a reentrant corner irregularity, while the remaining three possess a torsional plan irregularity. The records create drift demands of the order of 0.05 and plastic rotation demands of the order of 4–5% of a radian in the buildings with reentrant corners. These values point to performance at or near ‘Collapse Prevention’. Twisting in the torsionally sensitive buildings causes the plastic rotations on the moment frame on one face of the building (4–5% of a radian) to be as high as twice of that on the opposite face (2–3% of a radian). The asymmetric yield pattern implies a lower redundancy in the lateral force‐resisting system as the failure of the heavily loaded frame could result in a total loss of resistance to torsion. Copyright © 2006 John Wiley & Sons, Ltd. 相似文献
4.
This paper summarizes the results of an extensive study on the inelastic seismic response of X‐braced steel buildings. More than 100 regular multi‐storey tension‐compression X‐braced steel frames are subjected to an ensemble of 30 ordinary (i.e. without near fault effects) ground motions. The records are scaled to different intensities in order to drive the structures to different levels of inelastic deformation. The statistical analysis of the created response databank indicates that the number of stories, period of vibration, brace slenderness ratio and column stiffness strongly influence the amplitude and heightwise distribution of inelastic deformation. Nonlinear regression analysis is employed in order to derive simple formulae which reflect the aforementioned influences and offer a direct estimation of drift and ductility demands. The uncertainty of this estimation due to the record‐to‐record variability is discussed in detail. More specifically, given the strength (or behaviour) reduction factor, the proposed formulae provide reliable estimates of the maximum roof displacement, the maximum interstorey drift ratio and the maximum cyclic ductility of the diagonals along the height of the structure. The strength reduction factor refers to the point of the first buckling of the diagonals in the building and thus, pushover analysis and estimation of the overstrength factor are not required. This design‐oriented feature enables both the rapid seismic assessment of existing structures and the direct deformation‐controlled seismic design of new ones. A comparison of the proposed method with the procedures adopted in current seismic design codes reveals the accuracy and efficiency of the former. Copyright © 2007 John Wiley & Sons, Ltd. 相似文献
5.
Nicolas Luco Yasuhiro Mori Yosuke Funahashi C. Allin Cornell Masayoshi Nakashima 《地震工程与结构动力学》2003,32(14):2267-2288
Predictors (or estimates) of seismic structural demands that are less computationally time‐consuming than non‐linear dynamic analysis can be useful for structural performance assessment and for design. In this paper, we evaluate the bias and precision of predictors that make use of, at most, (i) elastic modal vibration properties of the given structure, (ii) the results of a non‐linear static pushover analysis of the structure, and (iii) elastic and inelastic single‐degree‐of‐freedom time‐history analyses for the specified ground motion record. The main predictor of interest is an extension of first‐mode elastic spectral acceleration that additionally takes into account both the second‐mode contribution to (elastic) structural response and the effects of inelasticity. This predictor is evaluated with respect to non‐linear dynamic analysis results for ‘fishbone’ models of steel moment‐resisting frame (SMRF) buildings. The relatively small number of degrees of freedom for each fishbone model allows us to consider several short‐to‐long period buildings and numerous near‐ and far‐field earthquake ground motions of interest in both Japan and the U.S. Before doing so, though, we verify that estimates of the bias and precision of the predictor obtained using fishbone models are effectively equivalent to those based on typical ‘full‐frame’ models of the same buildings. Copyright © 2003 John Wiley & Sons, Ltd. 相似文献
6.
Optimal design of tuned mass dampers for a multi‐storey cross laminated timber building against seismic loads 下载免费PDF全文
In this paper, the effectiveness of different design solutions for tuned mass dampers (TMD) applied to high‐rise cross‐laminated (X‐Lam) timber buildings as a means to reduce the seismic accelerations was investigated. A seven‐storey full‐scale structure previously tested on shaking table was used as a reference. The optimal design parameters of the TMDs, i.e. damping and frequency ratios, were determined by using a genetic algorithm on a simplified model of the reference structure, composed by seven masses each representing one storey. The optimal solutions for the TMDs were then applied to a detailed finite element model of the seven‐storey building, where the timber panels were modelled with shell elements and the steel connectors with linear spring. By comparing the numerical results of the building with and without multiple TMDs, the improvement in seismic response was assessed. Dynamic time‐history analyses were carried out for a set of seven natural records, selected in accordance with Eurocode 8, on the simplified model, and for Kobe earthquake ground motion on the detailed model. Results in terms of acceleration reduction for different TMD configurations show that the behaviour of the seven‐storey timber building can be significantly improved, especially at the upper storeys. Copyright © 2016 John Wiley & Sons, Ltd. 相似文献
7.
An attempt has been made to explore the general trends in the seismic response of plan‐asymmetric structures without any restrictions imposed by a particular code. Systems with structural elements in both orthogonal directions under bi‐directional excitation were studied. Idealized single‐storey models with bi‐axial eccentricity were employed. The systems were torsionally stiff and, in the majority of cases, mass‐eccentric. The main findings are: in general, inelastic torsional response is qualitatively similar to elastic torsional response. Quantitatively, the torsional effect on the flexible side, expressed as an increase of displacements due to torsion, decreases slightly with increasing plastic deformation, unless the plastic deformations are small. The response on the stiff side generally strongly depends on the effect of several modes of vibration and on the influence of the ground motion in the transverse direction. These influences depend on the structural and ground motion characteristics in both directions. Reduction of displacements due to torsion, typical for elastic torsionally stiff structures, usually decreases with increasing plastic deformations. As an additional effect of large plastic deformations, a flattening of the displacement envelopes in the horizontal plane usually occurs, indicating that torsional effects in the inelastic range are generally smaller than in the elastic range. The dispersion of the results of inelastic torsional response analysis is generally larger than that of elastic analysis. Copyright © 2005 John Wiley & Sons, Ltd. 相似文献
8.
This paper deals with the estimation of peak inelastic displacements of SDOF systems, representative of typical steel structures, under constant relative strength scenarios. Mean inelastic deformation demands on bilinear systems (simulating moment resisting frames) are considered as the basis for comparative purposes. Additional SDOF models representing partially‐restrained and concentrically‐braced (CB) frames are introduced and employed to assess the influence of different force‐displacement relationships on peak inelastic displacement ratios. The studies presented in this paper illustrate that the ratio between the overall yield strength and the strength during pinching intervals is the main factor governing the inelastic deformations of partially‐restrained models and leading to significant differences when compared with predictions based on bilinear structures, especially in the short‐period range. It is also shown that the response of CB systems can differ significantly from other pinching models when subjected to low or moderate levels of seismic demand, highlighting the necessity of employing dedicated models for studying the response of CB structures. Particular attention is also given to the influence of a number of scalar parameters that characterise the frequency content of the ground motion on the estimated peak displacement ratios. The relative merits of using the average spectral period Taver, mean period Tm, predominant period Tg, characteristic period Tc and smoothed spectral predominant period To of the earthquake ground motion, are assessed. This paper demonstrates that the predominant period, defined as the period at which the input energy is maximum throughout the period range, is the most suitable frequency content scalar parameter for reducing the variability in displacement estimations. Finally, noniterative equivalent linearisation expressions based on the secant period and equivalent damping ratios are presented and verified for the prediction of peak deformation demands in steel structures. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献
9.
A series of dynamic experiments was performed on two‐story glue‐laminated timber frames. The tests included sinusoidal sweeps in one direction, arbitrary signals simulating earthquake loads in two directions, and harmonic free vibration at the fundamental frequency. Two experimental frames were manufactured and tested: (1) a control with horizontal laminations and no reinforcement at joint areas, and (2) a new frame design with densified material in the joint area that was further reinforced by glass‐fiber composite material. Preliminary tests of scaled and full‐size beam‐to‐column connections were performed to obtain connection characteristics needed for subsequent analytical modeling. Copyright © 2004 John Wiley & Sons, Ltd. 相似文献
10.
This paper deals with seismic analysis of plan‐asymmetric r/c frame multi‐storey buildings. Non‐linear numerical analyses are carried out by using a lumped plasticity model for beams and a multi‐spring model for columns, the latter one introduced to account for axial force–biaxial bending moment interaction. A comparison between numerical analyses and experimental test results is reported in order to calibrate the numerical model, showing that the adopted model is very suitable. In order to study the effects of the earthquake orthogonal component, the seismic response of the modelled structure under uni‐directional excitation is compared to the one under bi‐directional excitation. Such comparison shows that the maximum base shear and the top displacement are not very sensitive to the presence of the orthogonal component, which, conversely, leads to large increase in the column plastic excursions. Copyright © 2007 John Wiley & Sons, Ltd. 相似文献
11.
The elastic and inelastic seismic response of plan‐asymmetric regular multi‐storey steel‐frame buildings has been investigated under bi‐directional horizontal ground motions. Symmetric variants of these buildings were designed according to Eurocodes 3 and 8. Asymmetric buildings were created by assuming a mass eccentricity in each of the two principal directions. The torsional response in the elastic and inelastic range is qualitatively similar with the exception of the stiff edge in the strong direction of torsionally stiff buildings and the stiff edge in the weak direction of torsionally flexible buildings. The response is influenced by the intensity of ground motion, i.e. by the magnitude of plastic deformation. In the limiting case of very strong ground motion, the behaviour of initially torsionally stiff and initially torsionally flexible buildings may become qualitatively similar. A decrease in stiffness due to plastic deformations in one direction may substantially influence the behaviour in the orthogonal direction. The response strongly depends on the detailed characteristics of the ground motion. On average, torsional effects are reduced with increasing plastic deformations, unless the plastic deformations are small. Taking into account also the dispersion of results which is generally larger in the inelastic range than in the elastic one, it can be concluded that (a) the amplification of displacements determined by the elastic analysis can be used as a rough estimate also in the inelastic range and (b) any favourable torsional effect on the stiff side of torsionally stiff buildings, which may arise from elastic analysis, may disappear in the inelastic range. The conclusions are limited to fairly regular buildings and subject to further investigations. Copyright © 2005 John Wiley & Sons, Ltd. 相似文献
12.
A series of E‐Defense shaking table tests are conducted on a large‐scale test specimen that represents a high‐rise steel building. Two types of connections featuring the connection details commonly used in 1970s, in the early days of high‐rise construction in Japan, are adopted: the field‐welded connection consisting of welded unreinforced flanges and a bolted web type, and the shop‐welded connection in which the flanges and web are all‐welded to the column flange in the shop. To examine the seismic capacity of a total of 24 beam‐to‐column connections of the specimen, particularly when it is subjected to long‐period ground motion characterized not so much by large amplitude as by very many cycles of repeated loading, the test specimen is shaken repeatedly until the connections fractured. The test results indicate that a few of the field‐welded connections fractured from the bottom flange weld boundary in a relatively small cumulative rotation primarily due to the difficulties in ensuring the welding and inspection performance in the actual field welding. The shop‐welded connections are able to sustain many cycles of plastic rotation, with an averaged cumulative plastic rotation of 0.86 rad. Two shop‐welded connections exhibit ductile fractures but only after experiencing many cycles. The presence of RC floor slabs promotes the strain concentration at the toe of the weld access hole in the bottom flange by at least twice compared with the case without the slab, which had resulted in a decrease in the cumulative plastic rotation by about 50%. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
13.
In this paper, a numerical model to estimate the dissipative capacity and describe the cyclic response of cross‐laminated (X‐lam) timber buildings is presented. The connections between panels and to the foundation (metal hold‐downs and angle brackets, and screwed connectors) are modelled with nonlinear hysteretic multispring elements taking into account the strength interaction between different degrees of freedom according to a predefined domain. The timber components (solid X‐lam floors and wall panels) are modelled using elastic shell elements. By calibration on experimental cyclic tests carried out on each degree of freedom, important features of timber connection behaviour such as post‐peak strength, pinching and stiffness degradation can all be considered. In addition, the effect of friction at the interface between panels and with foundation can be taken into account. These springs have been implemented as external subroutines in a widespread software package such as Abaqus. By comparison with the experimental results of cyclic tests carried out on single X‐lam walls, coupled X‐lam walls and a single‐storey X‐lam building, the accuracy of the proposed model is demonstrated. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
14.
This paper presents the main results of the evaluation of residual inter‐story drift demands in typical moment‐resisting steel buildings designed accordingly to the Mexican design practice when subjected to narrow‐band earthquake ground motions. Analytical 2D‐framed models representative of the study‐case buildings were subjected to a set of 30 narrow‐band earthquake ground motions recorded on stations placed in soft‐soil sites of Mexico City, where most significant structural damage was found in buildings as a consequence of the 1985 Michoacan earthquake, and scaled to reach several levels of intensity to perform incremental dynamic analyses. Thus, results were statistically processed to obtain hazard curves of peak (maximum) and residual drift demands for each frame model. It is shown that the study‐case frames might exhibit maximum residual inter‐story drift demands in excess of 0.5%, which is perceptible for building's occupants and could cause human discomfort, for a mean annual rate of exceedance associated to peak inter‐story drift demands of about 3%, which is the limiting drift to avoid collapse prescribed in the 2004 Mexico City Seismic Design Provisions. The influence of a member's post‐yield stiffness ratio and material overstrength in the evaluation of maximum residual inter‐story drift demands is also discussed. Finally, this study introduces response transformation factors, Tp, that allow establishing residual drift limits compatible with the same mean annual rate of exceedance of peak inter‐story drift limits for future seismic design/evaluation criteria that take into account both drift demands for assessing a building's seismic performance. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
15.
A procedure is presented to predict the storey where plastic drift dominates in two‐storey buildings under strong ground motion. The procedure utilizes the yield strength and the mass of each storey as well as the peak ground acceleration. The procedure is based on two different assumptions: (1) the seismic force distribution is of inverted triangular form and (2) the rigid‐plastic model represents the system. The first and the second assumptions, respectively, lead to lower and upper estimates of the base shear coefficient under which the drift of the first storey exceeds that of the second storey. The efficiency of the procedure is verified by dynamic response analyses using elasto‐plastic model. Copyright © 2008 John Wiley & Sons, Ltd. 相似文献
16.
Seismic response of 20‐story base‐isolated and fixed‐base reinforced concrete structural wall buildings at a near‐fault site 下载免费PDF全文
This paper investigates numerically the seismic response of six seismically base‐isolated (BI) 20‐story reinforced concrete buildings and compares their response to that of a fixed‐base (FB) building with a similar structural system above ground. Located in Berkeley, California, 2 km from the Hayward fault, the buildings are designed with a core wall that provides most of the lateral force resistance above ground. For the BI buildings, the following are investigated: two isolation systems (both implemented below a three‐story basement), isolation periods equal to 4, 5, and 6 s, and two levels of flexural strength of the wall. The first isolation system combines tension‐resistant friction pendulum bearings and nonlinear fluid viscous dampers (NFVDs); the second combines low‐friction tension‐resistant crosslinear bearings, lead‐rubber bearings, and NFVDs. The designs of all buildings satisfy ASCE 7‐10 requirements, except that one component of horizontal excitation, is used in the 2D nonlinear response history analysis. Analysis is performed for a set of ground motions scaled to the design earthquake and to the maximum considered earthquake (MCE). At both the design earthquake and the MCE, the FB building develops large inelastic deformations and shear forces in the wall and large floor accelerations. At the MCE, four of the BI buildings experience nominally elastic response of the wall, with floor accelerations and shear forces being 0.25 to 0.55 times those experienced by the FB building. The response of the FB and four of the BI buildings to four unscaled historical pulse‐like near‐fault ground motions is also studied. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
17.
Predictors of seismic structural demands (such as inter‐storey drift angles) that are less time‐consuming than nonlinear dynamic analysis have proven useful for structural performance assessment and for design. Luco and Cornell previously proposed a simple predictor that extends the idea of modal superposition (of the first two modes) with the square‐root‐of‐sum‐of‐squares (SRSS) rule by taking a first‐mode inelastic spectral displacement into account. This predictor achieved a significant improvement over simply using the response of an elastic oscillator; however, it cannot capture well large displacements caused by local yielding. A possible improvement of Luco's predictor is discussed in this paper, where it is proposed to consider three enhancements: (i) a post‐elastic first‐mode shape approximated by the deflected shape from a nonlinear static pushover analysis (NSPA) at the step corresponding to the maximum drift of an equivalent inelastic single‐degree‐of‐freedom (SDOF) system, (ii) a trilinear backbone curve for the SDOF system, and (iii) the elastic third‐mode response for long‐period buildings. Numerical examples demonstrate that the proposed predictor is less biased and results in less dispersion than Luco's original predictor. Copyright © 2006 John Wiley & Sons, Ltd. 相似文献
18.
Evaluation of seismic displacement demands from the September 19, 2017 Puebla‐Morelos (Mw = 7.1) earthquake in Mexico City 下载免费PDF全文
This short communication presents the assessment of seismic inelastic and elastic displacement demands computed from earthquake ground motions (EQGMs) recorded in Mexico City during the intermediate‐depth intraslab Puebla‐Morelos earthquake on 19 September 2017 (Mw = 7.1). Evaluation is conducted by means of peak elastic and inelastic displacement demand spectra, inelastic displacement ratio, CR, spectra, and generalized interstory drift spectra computed for selected recording stations located in different soil sites of Mexico City, including those located in areas of reported collapsed buildings. Results of this study confirm previous observations made from interplate (subduction) EQGMs that peak inelastic displacement demands are greater than corresponding elastic counterparts for short‐to‐medium period structures, while the opposite is true for medium‐to‐long period structures. Possible basin site effects were identified from generalized interstory drift spectra. It is also shown that an equation introduced in the literature to obtain estimates of CR developed from interplate EQGMs provides also a good estimate for mean CR computed from the intermediate‐depth intraslab EQGMs. 相似文献
19.
The effect of the long‐period filter cut‐off, Tc, on elastic spectral displacements is investigated using a strong ground‐motion database from Europe and the Middle East. The relation between the filter and oscillator responses is considered to observe the influence of Tc for both analogue and digital records, and the variations with site classification, magnitude, filter order and viscous damping. Robust statistics are derived using the re‐processed European data to generalize the effects of the long‐period filter cut‐off on maximum oscillator deformation demands as a function of these seismological and structural features. Statistics with a 95% confidence interval are derived to suggest usable period ranges for spectral displacement computations as a function of Tc. The results indicate that the maximum period at which spectral displacements can be confidently calculated depend strongly on the site class, magnitude and filter order. The period range where reliable long‐period information can be extracted from digital accelerograms is twice that of analogue records. Copyright © 2006 John Wiley & Sons, Ltd. 相似文献
20.
The seismic capacity of beam‐to‐column connections in steel high‐rise frames is a matter of concern, particularly when they are subjected to long‐period ground motions. A previous full‐scale shaking table test conducted at the E‐Defense National Research Institute for Earth Science and Disaster Prevention in Japan disclosed cracks and fractures in such beam‐to‐column connections. This paper examines the effects of three types of beam‐to‐column connection retrofit: supplemental welds, wing plates, and a haunch. Quasi‐static member tests and a series of shaking table tests applied to a full‐scale specimen are conducted to quantify the respective performances of the retrofit schemes. The performance of a total of 28 connections tested by the member and shaking table tests is evaluated together with that of an additional 12 unretrofitted connections tested in the previous test. When the supplemental welds are applied only to the shear tab to the web, the connection fractures at the same instant as the connection without retrofit. The corresponding cumulative plastic rotation is not improved. When the supplement welds are further applied to the web‐to‐column connection, strain concentration at the bottom flange, primarily promoted by the presence of the RC floor slab, is significantly reduced, and the cumulative plastic rotation capacity is increased to eight times that of the connection without retrofit. For the wing plate connection and haunch connection, the critical section is moved from the beam end to the beam cross‐section corresponding to the tip of the wing plates or haunch, resulting in an improvement of ductility by eight times that of the unretrofitted connection. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献