1.
We present a revised method for the determination of concentrations of rare earth (REE) and other trace elements (Y, Sc, Zr, Ba, Hf, Th) in geological samples. Our analytical procedure involves sample digestion using alkaline fusion (NaOH-Na2O2) after addition of a Tm spike, co-precipitation on iron hydroxides, and measurement by sector field-inductively coupled plasma-mass spectrometry (SF-ICP-MS). The procedure was tested successfully for various rock types (i.e., basalt, ultramafic rock, sediment, soil, granite), including rocks with low trace element abundances (sub ng g−1). Results obtained for a series of nine geological reference materials (BIR-1, BCR-2, UB-N, JP-1, AC-E, MA-N, MAG-1, GSMS-2, GSS-4) are in reasonable agreement with published working values.  相似文献   

2.
We report new data for thirty seven elements determined in twenty six Chinese geochemistry reference materials using inductively coupled plasma-mass spectrometry and a reliable and simple dissolution technique. One hundred milligrams of sample were digested with 1 ml of HF and 0.5 ml of HNO3 in PTFE-lined stainless steel bombs heated to 200 °C for 12 hours. Insoluble residues were dissolved using 6 ml of 40% v/v HNO3 heated to 140 C for 3 hours. Analytical calibration was accomplished using aqueous standard solutions. Rhodium was used as an internal standard to correct for matrix effects and instrument drift. Precisions were typically better than 5% RSD. Most of the data presented here agree well with the published certified values. For the elements Zr, Hf and most other trace elements, the measured values were less than 10% in error when compared to certified values.  相似文献   

3.
建立了高分辨电感耦合等离子体质谱法(HR-ICP-MS)测定地球化学样品中钪、钇、镧、铈、镨、钕、钐、铕、钆、铽、镝、钬、铒、铥、镱和镥的分析方法。样品经氢氟酸-硝酸-硫酸-王水消解,试液直接用HR-ICP-MS测定钪、钇和14种稀土元素。用高分辨模式有效地避免了多原子离子及难熔氧化物离子对待测元素测定的干扰,为钪、钇和14种稀土元素选择了最佳的测定同位素和合适的分辨率;用地球化学标准物质制备的溶液优化仪器工作参数,确定了最佳的仪器测定条件。方法检出限(6σ)为0.003~0.013μg/g(稀释因子为1000),相对标准偏差(RSD,n=12)小于6%。方法经国家一级地球化学标准物质验证,测定值与标准值吻合。  相似文献   

4.
建立了微波消解-电感耦合等离子体质谱法测定土壤和沉积物中15种痕量稀土元素的分析方法。研究了溶样试剂、微波消解程序、标准溶液配制、质谱干扰与内标元素对稀土元素测定的影响。加入氢氟酸能有效打开样品,以HNO3-HF-H2O2混合酸溶解样品,稀土元素的溶出率较高。采用模拟土壤、沉积物中稀土元素天然组成比值的校正溶液,对稀土元素间的干扰具有明显的抑制作用。通过测定单个La、Ce、Pr、Nd和Ba的氧化物及氢氧化物产率,计算出等效干扰浓度,进而校正多原子离子干扰。利用103Rh内标校正系统,有效地抑制了分析信号的动态漂移。方法检出限为1.2~7.1 ng/g,精密度(RSD)≤5.3%(n=6),加标回收率为86.1%~110.1%。使用土壤、沉积物标准物质进行验证,测定结果与标准值相符。建立的方法样品处理程序简单快速、线性范围宽、分析重现性好、结果准确,适用于大批量地质样品的分析。  相似文献   

5.
稀土元素由于化学性质稳定,均一化程度高,常作为地球化学示踪剂,为揭示岩石、矿物成因、成岩成矿的地球化学条件以及物质来源和岩浆分异演化等提供重要信息,因此,建立快速、准确地测定地质样品中稀土元素含量的方法非常重要。地质样品因基体复杂,大部分的样品前处理需要酸溶,酸溶试剂用量大,溶样过程中产生的酸雾易对实验人员造成伤害,且批量样品前处理劳动强度大。基于此,本文建立了以全自动石墨消解仪消解样品,“加酸—消解—赶酸—定容—摇匀”全程用软件控制,以Rh和Re为内标,电感耦合等离子体质谱法(ICP-MS)测定土壤和水系沉积物中La、Ce、Pr、Nd、Sm、Eu、Gd、Tb、Dy、Ho、Er、Tm、Yb、Lu、Y等15个稀土元素的方法。通过12个土壤和水系沉积物国家一级标准物质对消解程序、消解混合酸及方法精密度、准确度和检出限进行研究。结果表明:按照优化后的消解程序消解土壤和水系沉积物,混合酸用量为4mL,稀土各元素测定值与标准值一致,相对误差(RE)绝对值在0~6.67%之间,ΔlgC绝对值在0~0.028之间,相对标准偏差(RSD)在0.97%~4.62%之间。全自动石墨消解因自动化操作,操作条件一致,温度均匀,精度更高,各元素的RSD值均小于电热板消解的元素RSD值。本方法精密度、准确度和检出限满足《地质矿产实验室测试质量管理规范》的要求,混合酸用量远低于常用的电热板消解法,相应的环境污染也减少;方法精密度优于常用的电热板消解法。前处理时只需要称样后将消解管置于石墨消解仪中,溶样全过程自动完成,自动化程度高,适用于批量样品的测试。  相似文献   

6.
贾双琳  赵平  杨刚  孙霞  何海 《岩矿测试》2014,33(2):186-191
测定地质样品中的稀土元素时,用碱熔法处理样品过程繁琐,混合酸敞开酸溶法的酸种类多,用量较大,而微波消解法批次处理样品少,效率不高。本文比较了7种混合酸敞开酸溶体系、硝酸-氢氟酸高压密闭体系对样品溶样的效果,采用电感耦合等离子体质谱测定15个稀土元素的含量,建立了一套样品前处理体系简单、酸用量少、相对快捷的测定地质样品中稀土元素的方法。通过对59件国家标准物质的测试分析,结果表明硫酸-氢氟酸敞开酸溶和硝酸-氢氟酸高压密闭溶样两套体系的方法检出限、精密度、准确度均能达到地质行业相关标准测试要求。硫酸-氢氟酸敞开酸溶体系对于样品中钡含量较高,或样品量较少时适用;硝酸-氢氟酸高压密闭溶样体系的检出限更低,适用于大批量样品的分析测试。两套体系均不需要进行数学干扰校正,且酸用量少(最多6 mL),分析效率高(平均每日分析测试300件),有较大的推广应用价值。  相似文献   

7.
采用硝酸-氢氟酸-过氧化氢于微波消解仪中分解样品,电感耦合等离子体质谱法测定贵州遵义地区某黑色页岩中稀有稀土元素的含量。对页岩标准物质(GBW 07107)和水系沉积物地球化学成分分析标准物质(GBW07305、GBW 07310)的分析,测定值与标准值相一致。对黑色页岩的分析结果较好,方法精密度(RSD,n=6)各元素均小于4%,加标回收率为97.9%~100.1%。方法准确度高、简单、快捷,一次溶样可同时测定多种元素。  相似文献   

8.
This paper presents data on REE and Y, Nb, Zr, Hf, Ta, Th and U abundances for two candidate reference materials (RMs), spinel lherzolite LSHC-1 and amphibole Amf-1, being currently developed at the Institute of Geochemistry SB RAS, Irkutsk. To determine the contents of these elements inductively coupled plasma-mass spectrometry was applied with: (i) solution nebulisation (solution ICP-MS) and (ii) laser ablation (LA-ICP-MS) of fused glass disks. The precision of results obtained by both techniques was better than 6% RSD for most elements. Accuracy was assessed by using the geochemical RMs JB-2, JGb-1 (GSJ) and MAG-1 (USGS). The trace element results by solution ICP-MS for JGb-1 and JB-2 agree with reference values presented by Imai et al. (1995, this Journal) within 1–10%. Significant differences were found for Nb and Ta determinations. The accuracy of LA-ICP-MS results evaluated by RM MAG-1 was within 4%, except for Eu (about 10%). The analytical results obtained for LSHC-1 and Amf-1 by solution ICP-MS and LA-ICP-MS were in good agreement with each other and with INAA and XRF data presented for the certification of these RMs. They can be considered as the indicative values for assigning certified values to the above-mentioned RMs.  相似文献   

9.
用电感耦合等离子体质谱法(ICP-MS)测定地质样品中的稀土及难熔元素,混合酸敞开酸溶法和碱熔融法是两种主要的溶样方法。但地质样品组分复杂,元素之间存在相互共生的现象,对于特殊元素、特殊样品用传统酸溶法会造成部分元素消解不完全,使测定结果不准确;而碱熔法的操作过程繁琐,且溶液盐度高,易产生基体干扰和堵塞仪器进样系统。本文改进了传统四酸和五酸体系,采用氢氟酸-硝酸-硫酸敞开酸溶体系,用国家一级标准物质制作标准曲线测定15种稀土元素,方法准确度(ΔlgC)为0.001~0.027。同时改进了偏硼酸锂碱熔法,样品用偏硼酸锂碱熔提取,加入氢氧化钠调节溶液至碱性条件,所测元素与偏硼酸锂共沉淀后过滤分离熔剂,再用硝酸复溶测定15种稀土元素及铌钽锆铪。两种溶样方法的测定值与认定值的相对误差为1.09%~9.30%。将混合酸敞开酸溶法测定稀土元素、偏硼酸锂碱熔法测定铌钽锆铪的结果与其他实验室密闭酸溶法相比,两组数据的相对偏差为0.13%~15.32%。本实验表明,混合酸敞开酸溶法适用于测定地质样品中的稀土元素,偏硼酸锂碱熔法不仅适用于测定地质样品中的稀土元素及铌钽锆铪,也适用于测定如古老高压变质岩石及铝含量高的样品中的铌钽锆铪。  相似文献   

10.
和田玉的稀土元素丰富,准确测定稀土元素含量对于揭示和田玉成矿物质来源、成矿流体的性质和矿床成因具有重要的意义。本文通过比较硝酸-氢氟酸、四硼酸锂-偏硼酸锂碱熔两种前处理方法,确定了使用硝酸-氢氟酸溶样,再采用电感耦合等离子体质谱法(ICP-MS)测定和田玉中钇镧铈镨钕钐铕钆铽镝钬铒铥镱镥15种稀土元素的含量。为降低基体效应,以103Rh和49In作内标补偿基体效应和校正灵敏度漂移,样品检出限为0.0008~0.0091μg/L,回收率为101.0%~120.0%,精密度(RSD)为0.55%~1.83%(n=11)。本方法的用酸量少,空白值低,应用于不同地区和田玉的分析,其稀土元素的配分模式特征为右倾型轻稀土富集,初步探讨的稀土元素丰度特征可为研究主产区宝玉石的矿床成因提供依据。  相似文献   

11.
电感耦合等离子体质谱法测定井间示踪剂中稀土元素   总被引:2,自引:3,他引:2  
以甲醇为稀释剂,用电感耦合等离子体质谱法快速测定稀土示踪剂中17个稀土元素。研究表明,在优化的稀释剂甲醇浓度为2%(体积分数)、pH<2.47的条件下测定稀土元素,方法精密度(RSD)为1.23%~2.83%,日间6次测定的精密度为2.25%~4.76%,各稀土元素线性关系良好,检出限为2.0~9.0 ng/L;17个稀土元素的加标回收率为85%~108%,满足痕量元素分析要求。  相似文献   

12.
Rare earth element analyses are widely used in geology, environmental science and archaeology. Over the past decade inductively coupled plasma-mass spectrometry has become an important source of rare earth data on geological material. However, ICP-MS analysis of rock samples without pre-concentration can be problematic because of complex sample matrices that can generate significant molecular isobaric interferences on rare earth peaks and which need to be corrected. Such problems are exacerbated for ultramafic rocks because the low levels of rare earth elements demand more concentrated solutions in order to maintain signals above background levels. These high solid loads result in intra-run changes in instrument sensitivity which need to be monitored. Pre-concentration chemistries have been developed in order to avoid high solid loads but these are time-consuming and must offer quantitative recoveries or use a yield tracer. Here, we describe an alternative method for rare earth element analysis by ICP-MS, which involves no pre-concentration and is, therefore, able to deliver data rapidly. Our approach is to apply an external correction procedure, based on the analysis of a reference material closely matched in composition to the unknown samples, which allows correction for both interferences and variations in instrument sensitivity. Testing this method, we obtained accurate rare earth element results for basaltic rocks with a precision of about 2% (1s). We demonstrate that the method is also applicable to ultramafic rocks with abundances at ultra-trace (ng g−1) level and present data for twelve separate dissolutions of the peridotite USGS PCC-1 and four separate dissolutions of the dunite DTS-1 reference materials. The repeatability of the data is between 3% and 9% (1s).  相似文献   

13.
磷矿石中伴生的大量稀土,是继离子型稀土矿后重要的稀土后备资源。对磷矿石稀土元素分析测定方法的研究具有重要意义。本实验采用盐酸-硝酸-氢氟酸-硫酸体系消解、王水提取,建立了应用电感耦合等离子质谱法(ICP-MS)测定磷矿石中15种稀土元素的分析方法。经优化实验选取了合适的称样量以保证分析结果的准确可靠。选择合适的分析同位素及采用干扰校正方程以消除质谱干扰,利用103Rh为内标元素,有效抑制了分析信号的动态漂移,用于测定磷矿石国家标准物质中的15种稀土元素,方法的检出限为0.001~0.021μg/g,精密度均小于6.0%(n=12),加标回收率在95.7%~108.0%。适合推广运用于大批量磷矿石中稀土分量的快速分析  相似文献   

14.
样品用HNO3-HF高压密闭消解,电感耦合等离子体质谱测定海洋沉积物中15种稀土元素。研究了消解方法、酸体系和质谱干扰对稀土元素测定的影响。结果表明,相比于电热板消解和微波消解,高压密闭消解具有酸用量少、消解完全、消解过程损失少等优点;HNO3-HF体系能有效地分解海洋沉积物样品;利用干扰离子校正方程,能有效地校正Ba和轻稀土元素所形成的多原子离子干扰。15种稀土元素的方法检出限为3~15 ng/g。使用水系沉积物标准物质GBW 07309和GBW 07311、海底沉积物标准物质GBW 07313进行验证,测定值与标准值基本吻合,相对标准偏差和相对误差均低于5%。方法用于长江口沉积物样品的测定,精密度(RSD,n=6)小于5%,加标回收率为95.8%~104%。该方法检出限低,精密度和准确度高,适用于大批海洋沉积物样品的分析。  相似文献   

15.
黑钨矿单矿物通常混入铬、钙、镁、钴、钪和稀土等元素,属于富含稀土型矿物,准确测定黑钨矿中的稀土元素对判定黑钨矿矿床的成因相当重要。黑钨矿单矿物样品经硝酸-氢氟酸高压密闭溶解,蒸干除去氢氟酸,以硝酸提取使稀土元素进入溶液,钨则以钨酸的形式从溶液中沉淀而分离,采用电感耦合等离子体质谱法测定稀土元素的含量。用Rh、Re双内标校正,有效地降低了分析信号漂移对分析结果的影响;Ba对153Eu干扰、Pr、Ce对157Gd干扰,采用分析软件在线扣除。该方法消除了钨基体元素的干扰,复溶沉淀实验表明残留稀土相对量小于10%,稀土元素的测定值与过氧化钠碱熔法的结果相符。方法加标回收率为94.2%~104.0%,相对标准偏差小于10%,检出限小于0.026μg/g。方法简便,准确度高,检出限低,适用于黑钨矿单矿物的分析。  相似文献   

16.
萤石中稀土元素的研究对揭示成矿物质来源、成矿流体的性质和矿床成因均具有十分重要的意义。传统的过氧化钠碱熔-电感耦合等离子体质谱(ICP-MS)分析方法可以解决萤石中稀土元素的测定问题,但过氧化钠提纯难度高,过程繁杂,不宜大量样品的处理,且待测溶液总盐度大易产生基体干扰等;常规的酸溶法因使用的试剂一般为硝酸和氢氟酸,这些酸均不与萤石的主要成分氟化钙发生反应而很少应用。本文基于氟化钙能溶于硫酸和硼酸,采用硼酸溶液(10%硫酸和25%盐酸介质)和氢氟酸处理样品,硝酸提取,引入103Rh和185Re双内标,建立了硼酸溶液敞口酸溶ICP-MS测定萤石中稀土元素的分析方法。相比于传统的过氧化钠碱熔方法,本方法采用的试剂纯度高,可以有效地降低空白,方法检出限为0.002~0.016μg/g,低于过氧化钠碱熔方法的检出限(0.006~0.058μg/g),回收率在94.0%~107.6%之间,方法精密度(RSD)为0.7%~2.7%。本方法配制的硼酸溶液能够有效地与萤石反应,可充分分解萤石样品,简化了样品处理流程,有效地控制了稀土元素的损失,数据可靠性高,适用于大量萤石样品的稀土元素分析。  相似文献   

17.
本文建立了以全自动石墨消解仪消解样品,“加酸-消解-赶酸-定容-摇匀”全程用软件控制,以Rh、Re为内标,电感耦合等离子体质谱法测定岩石中La、Ce、Pr、Nd、Sm、Eu、Gd、Tb、Dy、Ho、Er、Tm、Yb、Lu、Y 15种稀土元素含量的方法。通过对岩石国家一级标准物质GBW07103、GBW07104、GBW07105、GBW07108、GBW07109、GBW07110、GBW07112、GBW07122进行方法酸用量、方法精密度、准确度和检出限的测试研究。结果表明:按照消解程序消解的上述岩石国家标准物质,各元素测定值与标准值一致,相对标准偏差在0.98%~4.41%之间,方法精密度优于常用的电热板消解法,方法精密度、准确度和检出限满足地质矿产实验测试质量管理规范的要求,该方法用酸量较少,自动化程度高,可应用于批量样品的测试。  相似文献   

18.
煤和含煤岩系在特定地质条件下可以富集稀土等金属元素。煤及矸石燃烧后产生的飞灰,其金属元素富集度更高,有望成为稀土等关键矿产的替代来源之一。针对煤系样品有机物含量高、基体组成复杂等问题,本文通过溶样方式、消解酸体系、浸提液、质谱干扰及扣除等条件实验研究,利用高压密闭酸溶法和半密闭酸溶法建立了分别适用于煤和煤系样品中稀土元素的电感耦合等离子体质谱(ICP-MS)分析方法。结果表明,硝酸-氢氟酸高压密闭酸溶法能够实现煤中稀土元素的准确测定,但对煤飞灰和煤矸石的稀土元素回收率不稳定,不同样品稀土回收率在37%~123%之间。在原有消解酸体系中,加入硫酸和高氯酸或改用盐酸复溶,均不能有效地提高稀土元素的回收率。五酸半密闭酸溶可以实现煤飞灰、煤矸石等煤系样品中稀土元素的完全分解。利用X射线衍射(XRD)和扫描电子显微镜(SEM)技术对煤系样品中元素的赋存状态进行了初步解析,揭示了高铝矿物是造成煤矸石等煤系样品中稀土元素溶出率低的主要原因,为实验方案的制定和优化提供了理论依据。利用标准物质和实际样品开展了方法验证,所建方法具有良好的精密度(相对标准偏差为0.05%~9.98%)和正确度(相对误差为−10.2%~7.62%),检出限低,可以实现煤系样品中稀土元素的多元素准确测定,适用于大批量样品中稀土元素的分析测试。  相似文献   

19.
The rare earth element and yttrium concentrations of the NRCC reference materials North Atlantic Surface seawater, NASS-5; Coastal Atlantic Surface Seawater, CASS-4; and the estuarine water, SLEW-3 have been precisely determined by ICP-MS after ca. 1:8 preconcentration following a triple chelation using HDEHP (phosphoric acid 2-ethylhexyl ester -mono and di ester mixture) in heptane, and back extraction in nitric acid. We propose reference values with uncertainties for all naturally occurring lanthanides and yttrium.  相似文献   

20.
采用酸溶一敞开溶矿技术,等离子体质谱法测定地质样品中的稀土元素。该方法选用高氯酸和硫酸,试验发现,硫酸的溶矿效果明显优于高氯酸,且硫酸的存在有利于消除Ba对稀土元素的质谱影响。用该方法对地质样品三类国家一级标样(GBW07401、GBW07103、GBW07309):进行验证,准确率达95%~105%,结果令人满意。  相似文献   