首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
We present the first measurements of vanadium (V) stable isotopes for six reference materials – USGS PCC‐1, BHVO‐2, BCR‐2, BIR‐1a, GSP‐2 and AGV‐2 – plus the widely available carbonaceous chondrite Allende. We present standard addition and matrix spiking tests to assess the robustness and reproducibility of our data. Standard addition utilised an enriched 50V solution designated VISSOX (Vanadium Isotope Standard Solution OXford). We further assessed the veracity of the method by spiking collected sample matrices with the same amount of a V standard solution, whose isotopic composition was defined as 0‰. Standard addition and matrix spiking tests recorded no appreciable artificial isotope fractionation. We estimate that the best currently attainable long‐term reproducibility of stable 51V/50V isotope measurements in complex matrices is 0.15‰, which is in the same order as the reproducibility achievable with standard solutions. Finally, a large range of ~ 1.2‰ in stable V isotopic composition was documented, with ~ 0.5‰ of that variation in high temperature igneous materials alone. The range and resolving power of V stable isotopes, with respect to igneous material, compared favourably with the magnitude of fractionation reported for other non‐traditional stable isotope systems, which bodes well for the utility of this new system.  相似文献   

2.
We present the first technique to obtain precise and accurate vanadium (V) stable isotope compositions by chemical isolation and multi‐collector inductively coupled plasma‐mass spectrometry (MC‐ICP‐MS). Separation of V from matrix elements was achieved via five separate ion exchange columns. The procedure quantitatively removed Ti and Cr, which contain direct isobaric interferences on the minor isotope 50V. Isotope compositions were determined using a conventional standard solution‐sample bracketing technique. The V isotope composition for an in‐house secondary standard solution from BDH Chemicals was δ51V = ?1.19 ± 0.12‰ (2s, n = 600), measured as the per mil deviation relative to the composition of a widely available Specpure Alfa Aesar (AA) vanadium solution. This represents an improvement in measurement precision on previous techniques of almost two orders of magnitude. The effects of adding Cr, Ti and S to standard solutions were explored to determine the robustness of protocols. Only very low levels of these elements could be tolerated to obtain precise and accurate isotope compositions and was achieved with the chemical purification procedure. Standard solutions from AA and BDH processed as unknowns through the entire chemical separation and measurement protocols returned 100% yields and the same isotopic compositions as those of unprocessed standard solutions.  相似文献   

3.
Cu、Zn、Fe同位素示踪是近年来发展起来的一项新兴的同位素地球化学方法。本文介绍了用多接收电感耦合等离子体质谱 (MC ICPMS)精确测量铜、锌、铁同位素比值的方法 ,发现这些元素的同位素组成在不同地质与成矿环境中有明显变异 ,因而它们在矿床学、古海洋学和生物学等诸多领域具有广泛的应用前景。  相似文献   

4.
An organic solvent‐free two‐step column procedure is presented that provided robust, high yield and super clean separation of Li from silicate rock sample matrices. The measured δ7Li value for BHVO‐2 of +4.29 ± 0.23‰ (1s) is comparable with the reported values. The δ7Li values for GSJ JP‐1 (+3.14 ± 0.41‰, 1s) and USGS DTS‐2 (+4.91 ± 0.34‰, 1s) presented here provide new reference values for ultramafic rock reference materials.  相似文献   

5.
Isotope dilution (ID) mass spectrometry is a primary method of analysis suited for the accurate and precise measurement of several trace elements in geological matrices. Here we present mass fractions and respective uncertainties for Cr, Cu, Ni, Sn, Sr and Zn in 10 silicate rock reference materials (BCR‐2, BRP‐1, BIR‐1, OU‐6, GSP‐2, GSR‐1, AGV‐1, RGM‐1, RGM‐2 and G‐3) obtained by the double ID technique and measuring the isotope ratios with an inductively coupled plasma‐mass spectrometer equipped with collision cell. Test portions of the samples were dissolved by validated procedures, and no further matrix separation was applied. Addition of spikes was designed to achieve isotope ratios close to unity to minimise error magnification factors, according to the ID theory. Radiogenic ingrowth of 87Sr from the decay of 87Rb was considered in the calculation of Sr mass fractions. The mean values of our results mostly agree with reference values, considering both uncertainties at the 95% confidence level, and also with ID data published for AGV‐1. Considering all results, the means of the combined uncertainties were < 1% for Sr, approximately 2% for Sn and Cu, 4% for Cr and Ni and almost 6% for Zn.  相似文献   

6.
地质样品铜、铁、锌同位素标准物质的研制   总被引:10,自引:0,他引:10  
合适的标准物质是进行同位素准确分析的基础和关键,本文介绍了基于地质样品的铜、铁、锌同位素分析标准参考物质的研制过程.所研制的标准物质为CAGSR-1,用于该标准物质研制的原始样品为玄武质组分的岩石成分分析国家标准物质GBW07105.按照国家一级标准的要求,对该标准物质进行了严格的均一性、稳定性检验和同位素定值分析.标准物质CAGSR-1的主要特性量值δ65Cu、δ56Fe、δ66Zn的推荐值及95%置信水平的不确定度为:δ65CuSRM976(‰)=0.10±0.02、δ56FeIRMM014(‰)=0.12±0.02、δ66ZnRomil(‰)=7.45±0.01.该标准物质可用于地质与环境样品铜、铁、锌同位素测定中化学流程评价和验证、质谱仪的校正及整个过程的分析质量控制.  相似文献   

7.
A novel preconcentration method is presented for the determination of Mo isotope ratios by multi‐collector inductively coupled plasma‐mass spectrometry (MC‐ICP‐MS) in geological samples. The method is based on the separation of Mo by extraction chromatography using N‐benzoyl‐N‐phenylhydroxylamine (BPHA) supported on a microporous acrylic ester polymeric resin (Amberlite CG‐71). By optimising the procedure, Mo could be simply and effectively separated from virtually all matrix elements with a single pass through a small volume of BPHA resin (0.5 ml). This technique for separation and enrichment of Mo is characterised by high selectivity, column efficiency and recovery (~ 100%), and low total procedural blank (~ 0.18 ng). A 100Mo‐97Mo double spike was mixed with samples before digestion and column separation, which enabled natural mass‐dependent isotopic fractionation to be determined with a measurement reproducibility of  < 0.09‰ (δ98/95Mo, 2s) by MC‐ICP‐MS. The mean δ98/95MoSRM 3134 (NIST SRM 3134 Mo reference material; Lot No. 891307) composition of the IAPSO seawater reference material measured in this study was 2.00 ± 0.03‰ (2s, n = 3), which is consistent with previously published values. The described procedure facilitated efficient and rapid Mo isotopic determination in various types of geological samples.  相似文献   

8.
A two‐step Th isolation protocol, involving micro‐columns of TRU‐Spec extraction chromatography material and AG1 resin, was evaluated. The MC‐ICP‐MS procedure included 232Th tailing characterisation and correction, and calibrator bracketing using an in‐house standard solution (ThS1) to correct for instrumental mass bias and Faraday cup to secondary electron multiplier relative gain. Repeated analyses of reference solutions (UCSC Th ‘A’, WUN, OU Th ‘U’, IRMM‐36) were consistent with published data. Six reference materials (A‐THO, BCR‐2, AGV‐2, BHVO‐2, BE‐N and BIR‐1) were processed. The average 230Th/232Th values obtained for these samples are in excellent agreement with published data. In addition, we report the first 230Th/232Th values for BE‐N and BIR‐1. The intermediate precisions for rock samples ranged from ± 0.24 to ± 0.49% (2 RSD) and were similar to those achieved for synthetic solutions, thereby supporting the overall validity of the chemical separation, data acquisition and reduction procedures. Counting statistics on the 230Th isotope was the most significant source of uncertainty. The intermediate precision of the mean 230Th/232Th for the Th‐depleted BIR‐1 (5.64 × 10?6 ± 0.27%, 2 RSD) is in the range of the analyses of other reference materials analysed in this study.  相似文献   

9.
Lead isotope ratio data were obtained with good precision and accuracy using a 266 nm femtosecond laser ablation (fLA) system connected to a multi‐collector ICP‐MS (MC‐ICP‐MS) and through careful control of analytical procedures. The mass fractionation coefficient induced by 266 nm femtosecond laser ablation was approximately 28% lower than that by 193 nm excimer laser ablation (eLA) with helium carrier gas. The exponential law correction method for Tl normalisation with optimum adjusted Tl ratio was utilised to obtain Pb isotopic data with good precision and accuracy. The Pb isotopic ratios of the glass reference materials NIST SRM 610, 612, 614; USGS BHVO‐2G, BCR‐2G, GSD‐1G, BIR‐1G; and MPI‐DING GOR132‐G, KL2‐G, T1‐G, StHs60/80‐G, ATHO‐G and ML3B‐G were determined using fLA‐MC‐ICP‐MS. The measured Pb isotopic ratios were in good agreement with the reference or published values within 2s measurement uncertainties. We also present the first high‐precision Pb isotopic data for GSE‐1G, GSC‐1G, GSA‐1G and CGSG‐1, CGSG‐2, CGSG‐4 and CGSG‐5 glass reference materials obtained using the femtosecond laser ablation MC‐ICP‐MS analysis technique.  相似文献   

10.
Metal leaching from metallurgical wastes (slags) by means of environmentally friendly approaches is promising for practical applications. The goal of this study was to compare the feasibility of metal bioleaching from Cu slags by means of Pseudomonas fluorescens and Acidithiobacillus thiooxidans. Two size particles (<0.3 mm and 1–2 mm) of two types of Cu slags (massive crystalline slag and granulated amorphous slag) were used to study metal (Cu, Zn and Fe) bioleaching. The 40-days bioleaching experiments with P. fluorescens began at circumneutral pH (7.0), whereas the experiments with A. thiooxidans were started under acidic (pH 2.5) conditions. The results demonstrated that A. thiooxidans catalyzes metal leaching from both slag types investigated. After 21 days of incubation, optimal leaching was achieved and up to 79% Cu, 76% Zn and 45% Fe could be extracted from crystalline slag under conditions of 1 wt.% pulp density and particle size <0.3 mm. The optimal efficiency achieved with amorphous slag was 81% Cu, 79% Zn and 22% Fe when 1% pulp density and 1–2 mm particle size were used. The use of P. fluorescens resulted in poor leaching efficiencies as compared to the performance of A. thiooxidans, presumably due to the higher pH conditions maintained during the P. fluorescens incubations. The maximum metal leaching efficiencies with P. fluorescens were achieved at 1% pulp density and particle size <0.3 mm and did not exceed 10% Cu, 4% Zn, 0.3% Fe for crystalline slag and 4% Cu, 3% Zn, 0.7% Fe for amorphous slag. Both slags exhibited a good potential for bioleaching with A. thiooxidans, however; further optimization of the process parameters (e.g. pulp density, particle size and pH) is needed to improve the efficiency.  相似文献   

11.
Small mass‐dependent variations of molybdenum isotope ratios in oceanic and island arc rocks are expected as a result of recycling altered oceanic crust and sediments into the mantle at convergent plate margins over geological timescales. However, the determination of molybdenum isotope data precise and accurate enough to identify these subtle isotopic differences remains challenging. Large sample sizes – in excess of 200 mg – need to be chemically processed to isolate enough molybdenum in order to allow sufficiently high‐precision isotope analyses using double‐spike MC‐ICP‐MS techniques. Established methods are either unable to process such large amounts of silicate material or require several distinct chemical processing steps, making the analyses very time‐consuming. Here, we present a new and efficient single‐pass chromatographic exchange technique for the chemical isolation of molybdenum from silicate and metal matrices. To test our new method, we analysed USGS reference materials BHVO‐2 and BIR‐1. Our new data are consistent with those derived from more involved and time‐consuming methods for these two reference materials previously published. We also provide the first molybdenum isotope data for USGS reference materials AGV‐2, the GSJ reference material JB‐2 as well as metal NIST SRM 361.  相似文献   

12.
A simple, rapid method for the determination of Re and Os concentrations and isotope compositions using isotope dilution multi‐collector inductively coupled plasma‐mass spectrometry (ID‐MC‐ICP‐MS) combined with Carius tube digestion and sparging introduction of Os was developed. For Os measurement, four channeltron ion counters to detect different Os isotopes were used simultaneously, which led to a drastic reduction in the measurement time. Rhenium isotopes were measured by means of eight Faraday cups with solution nebulisation and an ultrasonic membrane desolvator. The representative 188Os count rate of an Os standard solution containing 50 pg of total Os was approximately 110000–120000 cps at the onset of measurement; the Re intensity of our in‐house 10 pg g?1 standard solution reached 1820 V/μg g?1 with a sample uptake rate of 95–99 μl min?1. These values indicate that the sensitivity of the method was sufficient even for samples with low Re and Os concentrations, such as chert. As the temporal variations of the amplification efficiency of the ion counters differed from one another, we adopted a sample‐calibrator bracketing method to correct the measured Re and Os isotope ratios. The Re and Os concentrations via the isotope dilution method and the 187Os/188Os ratios of two sedimentary rock reference materials (JMS‐2 and JCh‐1) on the basis of the isotope ratios determined by the MC‐ICP‐MS and by negative thermal ionisation mass spectrometry (N‐TIMS) were comparable within their ranges. Based on Os isotope measurement of the IAG reference material [Durham Romil Os (DROsS)], the average difference from the recommended value and precision of Os isotope measurements by the sparging method in combination with multi‐ion‐counters were 0.72% and 0.76% [1RSD (%), n = 29], respectively. The precisions in the 187Os/188Os ratios [1RSD (%)] of JMS‐2, JCh‐1 and DROsS were 0.35–0.71, 1.56–3.31 and 0.99–1.28%, respectively, which depended on their Os ion intensities. No systematic difference was observed between the Re and Os geochemical compositions of JCh‐1 and JMS‐2 obtained by means of digestion with inverse aqua regia and CrO3‐H2SO4 solutions, suggesting that either acid solution can be used for the sparging method of sedimentary rock samples. As CrO3‐H2SO4 solution is believed to liberate predominantly the hydrogenous Re and Os fraction from organic‐rich sediment, the sparging method combined with CrO3‐H2SO4 digestion and multi‐ion‐counters in the mass spectrometry is expected to be a powerful tool for reconstructing the secular change in marine Os isotope compositions with high sample throughput.  相似文献   

13.
测定有机样品中元素含量和同位素时,处理样品常用的方法有干灰化法和湿法两种.目前,测定样品中Cu、Zn、Fe同位素时,多采用湿法处理样品.相对于湿法处理样品,干灰化法溶样迅速、耗酸量少,适合处理大量样品,但高温灼烧过程可能会导致样品中Cu、Zn、Fe同位素的分馏.本研究利用海州香薷植株,以湿法为基础,对干灰化法和湿法处理...  相似文献   

14.
The Lamont‐Doherty Earth Observatory radiogenic isotope group has been systematically measuring Sr‐Nd‐Pb‐Hf isotopes of USGS reference material BCR‐2 (Columbia River Basalt 2), as a chemical processing and instrumental quality control monitor for isotopic measurements. BCR‐2 is now a widely used geochemical inter‐laboratory reference material (RM), with its predecessor BCR‐1 no longer available. Recognising that precise and accurate data on RMs is important for ensuring analytical quality and for comparing data between different laboratories, we present a compilation of multiple digestions and analyses made on BCR‐2 during the first author's dissertation research. The best estimates of Sr, Nd and Hf isotope ratios and measurement reproducibilities, after filtering at the 2s level for outliers, were 87Sr/86Sr = 0.705000 ± 11 (2s, 16 ppm, n = 21, sixteen digestions, one outlier), 143Nd/144Nd = 0.512637 ± 13 (2s, 25 ppm, n = 27, thirteen digestions, one outlier) and 176Hf/177Hf = 0.282866 ± 11 (2s, 39 ppm, n = 25, thirteen digestions, no outliers). Mean Nd and Hf values were within error of those reported by Weis et al. (2006, 2007) in their studies of RMs; mean Sr values were just outside the 2s uncertainty range of both laboratories. Moreover, a survey of published Sr‐Nd‐Hf data shows that our results fall within the range of reported values, but with a smaller variability. Our Pb isotope results on acid leached BCR‐2 aliquots (n = 26, twelve digestions, two outliers) were 206Pb/204Pb = 18.8029 ± 10 (2s, 55 ppm), 207Pb/204Pb = 15.6239 ± 8 (2s, 52 ppm), 208Pb/204Pb = 38.8287 ± 25 (2s, 63 ppm). We confirm that unleached BCR‐2 powder is contaminated with Pb, and that sufficient leaching prior to digestion is required to achieve accurate values for the uncontaminated Pb isotopic compositions.  相似文献   

15.
We present a new procedure for the separation and purification of Cu and Zn from geological samples. Our procedure employed a single pass, triple‐stack column set‐up. The first column, filled with TRU resin (TrisKem International), quantitatively removed Fe and Ti from sample matrices. A second column, filled with pre‐filter resin (TrisKem International), removed organic compounds. Finally, a third column, filled with anion exchange resin (AG1‐X8, 200–400 mesh, Bio‐Rad), was used to separate Cu and Zn from the remaining matrix. Our procedure required about 50% less acid volume than previously reported methods for Cu and Zn separation, thereby minimising analytical blanks and column running times. Copper and Zn stable isotope ratios were determined by a Thermo Neptune Plus MC‐ICP‐MS using Zn and Cu external normalisation, respectively, in addition to sample‐standard bracketing to correct for instrumental mass bias. We explore the inter‐calibration of Cu and Zn isotope fractionation coefficients during analysis by measuring mixed Cu–Zn solutions with enhanced mass bias variation generated by varying sample gas flow rates. Our results demonstrate that this procedure is useful when variation in instrumental mass bias throughout analytical sequences is insufficient to inter‐calibrate Cu and Zn fractionation coefficients.  相似文献   

16.
A new method for the simultaneous recovery of U, Th and Pb from ca. 0.5 g calcium carbonate samples for the purpose of U‐(Th)‐Pb geochronometry is presented. The protocol employs ion‐exchange chromatography. Standard anion exchange resin (AG 1‐X8 100–200 mesh) was used as the static phase, and 90% acetic acid was used as the mobile phase to elute the unwanted matrix components; dilute nitric acid was used to elute the U, Th and Pb. Blanks of 1.8 pg Th, 6.4 pg Pb and 8.4 pg U were obtained. The protocol was evaluated by determining the isotopic composition of U‐Th‐Pb separates obtained from an in‐house reference material (prepared from a natural speleothem) by MC‐ICP‐MS. An independently dated speleothem was also reanalysed. Based on these tests, the extraction protocol had an acceptable blank and produced a Pb separate sufficiently free of matrix‐induced instrumental biases to be appropriate for U‐Th‐Pb chronology.  相似文献   

17.
Trace element concentrations in gold grains from various geological units in South Africa were measured in situ by field emission‐electron probe microanalysis (FE‐EPMA), laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) and synchrotron micro X‐ray fluorescence spectroscopy (SR‐μ‐XRF). This study assesses the accuracy, precision and detection limits of these mostly non‐destructive analytical methods using certified reference materials and discusses their application in natural sample measurement. FE‐EPMA point analyses yielded reproducible and discernible concentrations for Au and trace concentrations of S, Cu, Ti, Hg, Fe and Ni, with detection limits well below the actual concentrations in the gold. LA‐ICP‐MS analyses required larger gold particles (> 60 μm) to avoid contamination during measurement. Elements that measured above detection limits included Ag, Cu, Ti, Fe, Pt, Pd, Mn, Cr, Ni, Sn, Hg, Pb, As and Te, which can be used for geochemical characterisation and gold fingerprinting. Although LA‐ICP‐MS measurements had lower detection limits, precision was lower than FE‐EPMA and SR‐μ‐XRF. The higher variability in absolute values measured by LA‐ICP‐MS, possibly due to micro‐inclusions, had to be critically assessed. Non‐destructive point analyses of gold alloys by SR‐μ‐XRF revealed Ag, Fe, Cu, Ni, Pb, Ti, Sb, U, Cr, Co, As, Y and Zr in the various gold samples. Detection limits were mostly lower than those for elements measured by FE‐EPMA, but higher than those for elements measured by LA‐ICP‐MS.  相似文献   

18.
In this article, we document a detailed analytical characterisation of zircon M127, a homogeneous 12.7 carat gemstone from Ratnapura, Sri Lanka. Zircon M127 has TIMS‐determined mean U–Pb radiogenic isotopic ratios of 0.084743 ± 0.000027 for 206Pb/238U and 0.67676 ± 0.00023 for 207Pb/235U (weighted means, 2s uncertainties). Its 206Pb/238U age of 524.36 ± 0.16 Ma (95% confidence uncertainty) is concordant within the uncertainties of decay constants. The δ18O value (determined by laser fluorination) is 8.26 ± 0.06‰ VSMOW (2s), and the mean 176Hf/177Hf ratio (determined by solution ICP‐MS) is 0.282396 ± 0.000004 (2s). The SIMS‐determined δ7Li value is ?0.6 ± 0.9‰ (2s), with a mean mass fraction of 1.0 ± 0.1 μg g?1 Li (2s). Zircon M127 contains ~ 923 μg g?1 U. The moderate degree of radiation damage corresponds well with the time‐integrated self‐irradiation dose of 1.82 × 1018 alpha events per gram. This observation, and the (U–Th)/He age of 426 ± 7 Ma (2s), which is typical of unheated Sri Lankan zircon, enable us to exclude any thermal treatment. Zircon M127 is proposed as a reference material for the determination of zircon U–Pb ages by means of SIMS in combination with hafnium and stable isotope (oxygen and potentially also lithium) determination.  相似文献   

19.
A method was developed for the determination of low‐level rare earth elements (REEs) and thorium in ultramafic samples by inductively coupled plasma‐mass spectrometry. The conventional method for the digestion of ultramafic rocks using HNO3 and HF results in considerable amounts of insoluble fluorides because of the high contents of Mg (generally up to 24% m/m) in these rocks. In this study, we used H3BO3 as a complexing agent to break down the insoluble fluorides, and then separated the REEs from Fe and Mg major and Ba, Ca, Cr minor matrices by anion exchange and co‐precipitation, respectively. The whole procedural blanks estimated from sample‐free analyses ranged from 0.232 ng for Ce to 0.006 ng for Tm and Lu. Limits of detection for this method, defined as three times the standard deviation of these blank analyses, varied from 0.51 ng g?1 for Ce to 0.03 ng g?1 for Lu. The recovery of REEs using this technique, as determined using the standard addition method, ranged from 92.9% for Y to 102.0% for Er with 3% (RSD) variation. The method was validated using GAS (GeoPT‐12), JP‐1 and PCC‐1, and the results were comparable to literature values, elucidating the applicability to the determination of ultra trace REEs in ultramafic rocks.  相似文献   

20.
We report an improved procedure for the determination of the platinum‐group elements (PGE) and Re, and Os isotopes from a single sample aliquot by isotope dilution (ID) using inductively coupled plasma‐mass spectrometry (ICP‐MS) and negative thermal ionisation mass spectrometry (N‐TIMS), respectively. A two‐stage column method was used to purify PGE‐Re from their sample matrix and interfering elements (e.g., Mo, Zr and Hf) after Os had been separated by CCl4 solvent extraction. The first column separation step used cation exchange resin (AG50W‐X8) to concentrate PGE‐Re and some potential interfering elements (e.g., Mo, Zr and Hf). In the second step, N‐benzoyl‐N‐phenylhydroxylamine (BPHA) extraction resin was used to separate PGE‐Re from the remaining interfering elements, which all remained strongly absorbed to the resin. The method was used to determine the PGE and rhenium, and Os isotope ratios in a range of geochemical reference materials (TDB‐1, WGB‐1, BHVO‐2 and UB‐N). The obtained results agree well with those previously published. This new method enables PGE‐Re abundances and Os isotopic ratios to be determined on the same sample digestion, and circumvents the problems created by sample heterogeneity when comparing PGE and Re‐Os isotope data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号