首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到7条相似文献,搜索用时 4 毫秒
1.
There are several methods for determining the spatial distribution and magnitude of groundwater inputs to streams. We compared the results of conventional methods [dye dilution gauging, acoustic Doppler velocimeter (ADV) differential gauging, and geochemical end‐member mixing] to distributed temperature sensing (DTS) using a fibre‐optic cable installed along 900 m of Ninemile Creek in Syracuse, New York, USA, during low‐flow conditions (discharge of 1·4 m3 s?1). With the exception of differential gauging, all methods identified a focused, contaminated groundwater inflow and produced similar groundwater discharge estimates for that point, with a mean of 66·8 l s?1 between all methods although the precision of these estimates varied. ADV discharge measurement accuracy was reduced by non‐ideal conditions and failed to identify, much less quantify, the modest groundwater input, which was only 5% of total stream flow. These results indicate ambient tracers, such as heat and geochemical mixing, can yield spatially and quantitatively refined estimates of relatively modest groundwater inflow even in large rivers. DTS heat tracing, in particular, provided the finest spatial characterization of groundwater inflow, and may be more universally applicable than geochemical methods, for which a distinct and consistent groundwater end member may be more difficult to identify. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

2.
A new method was developed for analysing and delineating streambed water fluxes, flow conditions and hydraulic properties using coiled fibre‐optic distributed temperature sensing or closely spaced discrete temperature sensors. This method allows for a thorough treatment of the spatial information embedded in temperature data by creating a matrix visualization of all possible sensor pairs. Application of the method to a 5‐day field dataset reveals the complexity of shallow streambed thermal regimes. To understand how velocity estimates are affected by violations of assumptions of one‐dimensional, saturated, homogeneous flow and to aid in the interpretation of field observations, the method was also applied to temperature data generated by numerical models of common field conditions: horizontal layering, presence of lateral flow and variable streambed saturation. The results show that each condition creates a distinct signature visible in the triangular matrices. The matrices are used to perform a comparison of the behaviour of one‐dimensional analytical heat‐tracing models. The results show that the amplitude ratio‐based method of velocity calculation leads to the most reliable estimates. The minimum sensor spacing required to obtain reliable velocity estimates with discrete sensors is also investigated using field data. The developed method will aid future heat‐tracing studies by providing a technique for visualizing and comparing results from fibre‐optic distributed temperature sensing installations and testing the robustness of analytical heat‐tracing models. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
Water exchange across the sediment–water interface of streams impresses a characteristic thermal pattern at the interface. The use of fibre optic distributed temperature sensing at the sediment–water interface in a small sand‐bed stream identifies such temperature patterns. Groundwater and interflow can be differentiated based on the temporal evolution of temperature patterns. Additionally, sudden temperature changes at the sediment–water interface observed during the transit of floods enable spatial identification of local up and downwelling. Electromagnetic induction geophysics can detect subsurface texture structures that support groundwater–surface water exchange. Our results show that areas of permanent temperature anomalies observed with fibre optic distributed temperature sensing match areas of comparatively homogeneous electrical conductivity. This indicates groundwater discharge and enables differentiating groundwater discharge from interflow and local downwelling.  相似文献   

4.
The Badain Jaran Desert is the second largest desert of China with a total area of 49 200 km2. At least 72 perennial lakes are scattered throughout the desert, sustaining a unique desert–lake ecosystem. Groundwater of various origins was believed to play an essential role in maintaining those desert lakes, but hydrological measurements are lacking due to difficult field conditions. This study applied the distributed temperature sensing technique to continuously measure temperature variations in one of the desert lakes – the Badain Lake – to identify groundwater discharge to the lake based on the temperature differences between groundwater and lake water. Because temperature may be influenced by various unforeseen and temporary factors, it is critical to discern those factors that may affect the temperature such as solar radiation and vertical temperature stratification and to ensure that the temperature variations of the lake water as detected by the distributed temperature sensing are mainly caused by groundwater discharge. A time window was identified during which the groundwater discharge is the dominant factor that determines the temperature pattern of the lake water. The results show that the temperature near the eastern and southeastern lakeshore of the eastern Badain Lake is colder than the average, indicating that this area is the main groundwater discharge zone. Near the northwestern lakeshore adjacent to a sand dune, a weak cold abnormal area was identified, indicating that the sand dune is another recharge source to the lake through channelling the local precipitation toward the lake. The contribution from the sand dune, however, appeared to be less than that from the regional groundwater flow. This study provides the first identification of the temperature abnormal areas, which imply groundwater discharges into desert lakes and contributes to a better understanding of the unique desert–lake ecosystem. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
A two-dimensional walkaway vertical seismic profiling survey using distributed acoustic sensing was conducted at an onshore site in Japan. The maximum depth and the deviation of the observation well were more than 4,000 m and 81 degrees, respectively. Among the several methods for installing fibre optic cables, we adopted the inside coiled tubing method, in which coiled tubing containing a fibre optic cable is deployed. The signal-to-noise ratio of the raw shot gather was low, possibly due to poor coupling between the fibre optic cable and the subsurface formation resulting from the fibre optic cable deployment method and the existence of considerable tubewave noise. Nevertheless, direct P-wave arrivals, P–P reflections and P–S converted waves exhibited acceptable signal-to-noise ratios after careful optimization of gauge length for distributed acoustic sensing optical processing and the application of carefully parameterized tubewave noise suppression. One of the challenges in current distributed acoustic sensing vertical seismic profile data processing is the separation of P- and S-waves using only one-component measurements. Hence, we applied moveout correction using two-dimensional ray tracing. This process effectively highlights only reflected P-waves, which are used in subsequent subsurface imaging. Comparison with synthetic well seismograms and two-dimensional surface seismic data confirms that the final imaging result has a sufficiently high quality for subsurface monitoring. We acquired distributed acoustic sensing vertical seismic profile data under both flowing conditions and closed conditions, in which the well was shut off and no fluid flow was allowed. The two imaging results are comparable and suggest the possibility of subsurface imaging and time-lapse monitoring using data acquired under flowing conditions. The results of this study suggest that, by adopting the inside coiled tubing method without drilling a new observation well, more affordable distributed acoustic sensing vertical seismic profile monitoring can be achieved in fields such as CO2 capture and storage and unconventional shale projects, where monitoring costs have to be minimized.  相似文献   

6.
In order to maintain the scenic and eco-environmental values of a lake, we need to characterize its water interactions. Shahu Lake was used as a case study to show the interactions among replenishment water, lake water and groundwater in an arid region. Shahu Lake is located in the Ningxia Hui Autonomous Region of northwest China and has an area of 13.96 km2 and an average depth of 2.2 m. The groundwater modelling software MODFLOW was used. The analysis results show that hydraulic connectivity among replenishment water, lake water and groundwater is the crucial driving factor that affects the water level in Shahu Lake. The lake water level is highly sensitive to the volume of replenishment water. The groundwater is of great importance in balancing the water level in the lake and preventing it from drying up. It was determined that 13.8 × 106 m3/yr is the optimal volume of replenishment water for Shahu Lake in order to maintain the lake level at its normal state and also to make the best use of available water resources on a long-term basis. Understanding of the water interactions can promote effective management of water resources in Shahu Lake.
EDITOR D. Koutsoyiannis

ASSOCIATE EDITOR D. Hughes  相似文献   

7.
Long-term temperature monitoring was carried out in a borehole drilled for investigation of the Nojima fault, an active fault in SW Japan, using the distributed optical fiber temperature sensing (DTS) technique. Temperatures in the borehole had been measured every 1 m along an optical fiber cable with a resolution of about 0.1 K over a period of 6 years. Water injection experiments were conducted in this borehole in 1997, 2000 and 2003. Monitoring of the temperature profile was started after the first injection experiment, and the temperature profile remained very stable until the start of the second injection experiment. During the second and third experiments, the temperatures in the borehole dropped due to cooling by the injected water but no appreciable temperature change was observed below about 580 m. It clearly shows that the water leaked out of the hole around this point and the leaking depth is estimated to be about 540 m based on the shape of the temperature profile. After the injection was stopped, the recovery of the temperature to the undisturbed profile was exceptionally slow around the leaking point, resulting in a local temperature anomaly, probably because the water leaking out of the hole had cooled the surrounding formations extensively. A very similar temperature anomaly was observed at the beginning of temperature monitoring, which suggests that water leaked out at the same depth in the first injection experiment as well. Between the second and third injection experiments, the top of the borehole was kept open to allow groundwater discharge for about 1 month in 2000 and 2003. In both periods, groundwater flowed out continuously and the shapes of the observed temperature profiles indicate that the groundwater entered in the hole at the same depth as the leaking point during the injection experiments. The temperature records also show that the rate of discharge had been nearly constant through the two test periods. The water discharge appears to have been little affected by the water injection. These results demonstrate that the optical fiber temperature monitoring system is a very effective tool for hydrological experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号