首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
In this work, the treatment of photographic processing wastewaters (PPW) by electro‐Fenton process has been investigated. The Influence of operating conditions on kinetics and efficiency of electro‐Fenton process has been evaluated using carbon felt cathode and platinium (Pt) or boron‐doped diamond (BDD) anode. The results of electro‐Fenton treatment of PPW have shown that nearly complete removal of total phenols was obtained for all combinations with pseudo‐first rate constants of 0.07, 0.012, and 0.018/min for carbon felt/Pt, carbon felt/BDD and Pt/BDD cathode/anode combinations, respectively. The combination of carbon felt cathode with BDD anode achieved the highest total organic carbon (TOC) removal of 90%, while it did not exeed 40% for carbon felt/Pt combination. Increasing current intensity and Fe2+ dose enhances the efficiency of electro‐Fenton process. However, increasing pH decreases TOC removal during the treatment of PPW by electro‐Fenton process. The highest efficiency of electro‐Fenton process using BDD anode can be explained by the contribution of direct and indirect oxidation routes in the degradation mechanism of organics including (i) oxidation via hydroxyl radicals generated from the catalytic decomposition of H2O2 and from water discharge on BDD anode, (ii) direct oxidation of certain organic compounds on BDD anode, and (iii) mediated oxidation with inorganic oxidants electrogenerated from anodic oxidation of supporting salts.  相似文献   

4.
This study attempts to explore the possibility of treating dye solutions containing Disperse Yellow 119 and Disperse Red 167 by Fenton and Fenton under solar‐light oxidation processes. Experiments were conducted to examine the effects of various operating conditions on the performance of the treatment systems. The Fenton results showed that 98.6% spectral absorption coefficient (SAC) and 90.8% chemical oxygen demand (COD) removals were proved at pH 3, 50 mg/L Fe2+, and 75 mg/L H2O2, 15 min oxidation time for Disperse Yellow 119. After 40 min solar irradiation time during Fenton process the SAC removal was 99.1%. COD reduction of about 98.3% was observed at the same time. It was also obtained as 97.8% SAC and 97.7% COD removal with pH 3, 75 mg/L Fe2+, 100 mg/L H2O2, and 25 min oxidation time for Disperse Red 167 at this optimum conditions. For Disperse Red 167 during Fenton under solar light process, after 40 min of solar irradiation time the SAC and COD reduction were obtained 99.3 and 98.4%, respectively.  相似文献   

5.
6.
7.
8.
In this study, the oxidative decolorization of C.I. reactive yellow 145 (RY 145) from synthetic textile wastewater including RY 145 and polyvinyl alcohol by Fenton and sono‐Fenton processes which are the combination of Fenton process with ultrasound has been carried out. The effects of some operating parameters which are the initial pH of the solution, the initial concentration of Fe2+, H2O2, and the dye, temperature, and agitation speed on the color and chemical oxygen demand (COD) removals have been investigated. The optimum conditions have been found as [Fe2+] = 20 mg/L, [H2O2] = 20 mg/L, pH 3 for Fenton process and [Fe2+] = 20 mg/L, [H2O2] = 15 mg/L, pH 3 for sono‐Fenton process by indirectly sonication at 35 kHz ultrasonic frequency and 80 W ultrasonic power. The color and COD removal efficiencies have been obtained as 91 and 47% by Fenton process, and 95 and 51% by sono‐Fenton processes, respectively. Kinetic studies have been performed for the decolorization of RY 145 under optimum conditions at room temperature. It has been determined that the decolorization has occurred rapidly by sono‐Fenton process, compared to Fenton process.  相似文献   

9.
10.
Decolorization of C.I. Basic Blue 3 (BB3) by oxalate catalyzed photoelectro‐Fenton process based on carbon nanotube‐polytetrafluoroethylene (CNT‐PTFE) electrode as cathode under visible light was studied. A comparison of electro‐Fenton, photoelectro‐Fenton, and photoelectro‐Fenton/oxalate processes for decolorization of the solution containing BB3 has been performed. The results showed that color removal follows the decreasing order: photoelectro‐Fenton/oxalate > photoelectro‐Fenton > electro‐Fenton. Response surface methodology (RSM) was employed to assess individual and interactive effects of the four main independent parameters on the decolorization efficiency. A central composite design (CCD) was employed for optimization of photoelectro‐Fenton/oxalate treatment of BB3. The analysis of variance (ANOVA) showed a high coefficient of determination value (R2 = 0.958) and satisfactory prediction second‐order regression. This study clearly showed that RSM was one of the suitable methods to optimize the operating conditions.  相似文献   

11.
12.
The present study employed a modified Fenton system that aims to extend the optimum pH range towards neutral conditions for studying the oxidation of benzene, toluene, ethyl benzene, xylenes (BTEX) using glutamic acid (Glu) as an iron chelator. Addition of 20 mM Glu greatly enhanced the oxidation rate of BTEX in modified Fenton system at pH 5–7. A rapid mass destruction (>97% after 1 h) of BTEX as a water contaminant carried out in the presence of 500 mM H2O2, 10 mM Fe2+, and 20 mM Glu at pH 5 could be shown. The efficiency of this modified Fenton's system for mass destruction of BTEX in contaminated water was measured to estimate the impact of the major process variables that include initial concentrations of soluble Fe, H2O2, Glu (as metal chelating agent), and reaction time.  相似文献   

13.
14.
This paper discusses the possibility of immobilization of TiO2 nanoparticles onto recycled wool‐based nonwoven material, which can be utilized for removal of dyes from wastewater. The photocatalytic activity of TiO2 nanoparticles deposited on the nonwoven material was evaluated in the aqueous solution of direct dye C.I. Direct Blue 78 under the UV illumination. Nonwoven material modified with TiO2 nanoparticles provides complete removal of dye from the solution already after 4–6 h of UV illumination. However, photodegradation of the dye adsorbed on the nonwoven material was obtained within 24 h of UV illumination. The rate of dye adsorption and photodegradation depends on the amount of deposited TiO2 nanoparticles. The increase of initial dye concentration induced decrease in photocatalytic efficiency of immobilized TiO2 nanoparticles. The highest photodegradation rate was achieved in acidic conditions. Elevated temperatures positively affected the removal of dye from solution. Photocatalytic activity of TiO2 nanoparticles deposited on nonwoven material was preserved after three photodegradation cycles.  相似文献   

15.
A magnetic‐sulfonic graphene nanocomposite (G‐SO3H/Fe3O4) was synthesized and characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and X‐ray diffraction. It was used for removal of three cationic dyes: safranine T (ST), neutral red (NR), victoria blue (VB), and three anionic dyes: methyl orange, brilliant yellow, and alizarin red, from environmental water. The experimental conditions were optimized, including pH, amount of adsorbent, adsorption kinetics, adsorption isotherms, ionic strength, etc. The results show that G‐SO3H/Fe3O4 can adsorb cationic dyes more efficiently and selectively than anionic dyes at pH 6.0. In the first 10 min of adsorption time, more than 93% of the cationic dyes were removed by the sorbent. Adsorption kinetics follow the pseudo‐second‐order kinetic model well. The adsorption isotherm coincided with Langmuir and Freundlich adsorption models. The maximum adsorption capacities of G‐SO3H/Fe3O4 for ST, NR, and VB dyes were 199.3, 216.8, and 200.6 mg g?1. The adsorbed cationic dyes were eluted by using different pH values of ethanol as the solvent. The established method was simple, sensitive, and rapid, and was suitable for the adsorption of cationic dyes in environmental water.  相似文献   

16.
The feasibility of pilot‐scale mineralization of organic pollutants in wastewaters using the Electro‐Fenton® process is demonstrated. The treatment was applied in a continuous‐flow reactor, to solutions of nitrobenzene, 2,4‐D and benzoic acid and to actual wastewaters from a fine chemicals company along with a pulp and paper company. The results showed mineralization yields from 60 to 84% by simply applying the Electro‐Fenton® process. When a subsequent exposure to sunlight was carried out (Helielectro‐Fenton method), this mineralization almost went to completion, except for the effluent from the fine chemicals industry.  相似文献   

17.
Catechol is one of the most abundant phenolic components of olive mill wastewaters. In this article, the mineralization of this compound in synthetic aqueous solutions by the Fenton and photo‐Fenton processes is studied. It has been found that for 1.44 mM catechol, the total organic carbon of solutions is reduced about 94.4% at best after 60 min of Fenton treatment at optimized conditions of pH 3.0, 0.2 mM Fe2+, 7.09 mM H2O2, and 25°C. A faster and overall mineralization is attained by applying photo‐Fenton with UVA irradiation. o‐Benzoquinone, 1,2,3‐trihydroxybenzene and 1,2,4‐trihydroxybenzene were identified by GC–MS as primary quinonic and polyhydroxylated derivatives. Small amounts of generated carboxylic acids like muconic, maleic, malonic, acetic, oxalic, and formic acids were detected by ion‐exclusion chromatography. The Fe(III) complexes of these acids persist in the medium under Fenton conditions, while their photolysis by UVA light and that of other by‐products account for by the faster degradation and total mineralization achieved in the photo‐Fenton process. A reaction sequence for catechol mineralization by Fenton and photo‐Fenton involving all intermediates detected is proposed.  相似文献   

18.
Commercial ZnO, MnO2, and their acid‐treated forms were used as catalysts for oxidative degradation of Orange II dye in water. ZnO and MnO2 were treated with 0.5, 0.75, or 1.0 N aqueous H2SO4. The acid treated oxides were found to be highly effective in bringing about degradation of Orange II in water. As much as 68.7% of the dye in an aqueous solution of 1 mg/L concentration could be degraded with untreated ZnO as the catalyst. The degradation increased to 79.5% with 1.0 N acid treated ZnO as the catalyst when the reaction was carried out at room temperature for 240 min. The catalytic activity was slightly affected by the solution pH in the range of 2.0–8.0. With MnO2 as the catalyst, there was only 12.7% degradation of the dye, but this increased up to 100% when 0.5 N acid treated MnO2 was used as the catalyst. It was found that a catalyst loading of 5.0 g/L of raw and acid‐treated ZnO and a loading of 0.5 g/L of raw and acid‐treated MnO2 could bring about almost 100% degradation of Orange II in water in an interaction time of 240 min at room temperature.  相似文献   

19.
In this work, the treatment of actual agro‐industrial wastewaters (IWW) by a UV/H2O2 process has been investigated. The aqueous wastes were received from industrial olive oil mills and then treated by laboratory scale physicochemical methods, i. e., coagulation using ferrous and aluminum sulfate, decantation, filtration and adsorption on activated carbon. These wastes are brown colored effluents and have a residual chemical oxygen demand (COD) in the range of 1800 to 3500 mgO2 L–1, which cannot be further eliminated with physicochemical processes. The UV/H2O2 treatments were carried out under monochromatic irradiation at 254 nm using a thermostated reactor equipped with a mercury vapor lamp located in an axial position. The effects of initial H2O2 concentration, initial COD, pH and temperature have been studied in order to determine the optimum conditions for maximum color and COD removals. The experimental results reveal the suitability of the UV/H2O2 process for both removal of high levels of COD and effectively decolorizing the solution. In particular, 95% of color removal and 90% of COD removal were obtained under conditions of pH = 5 and 32°C using 2.75 g H2O2 g–1 COD L–1 during 6 h of UV‐irradiation. The treatment is unaffected by pH over the range 2 to 9. In addition, the COD removal is improved by increasing the temperature, whereas the color removal has not been affected by this parameter. The results show that the hydroxyl radicals generated from the catalytic decomposition of H2O2 by UV‐irradiation of the solution could be successfully used to mineralize the organics contained in IWW. The mineralization of the organics seems to occur in three main sequential steps: the first is the rapid decomposition of tannins leading to aromatic compounds, which are confirmed by the decolorization of the IWW; the second step corresponds to the oxidation of aromatics leading to aliphatic intermediates, which occurs by the cleavage of an aromatic ring, and is established by the removal of aromatics, and the final step is the slow oxidation of the aliphatic intermediates, which is measured by the COD removal.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号