首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new ion exchange chromatography method is presented for the isolation of high field‐strength elements (HFSE) from freshwater and seawater samples that have undergone iron coprecipitation. Large volumes of water can be condensed through the application of iron coprecipitation, but clean separation of elements from the precipitate proves difficult. The technique described is a five‐column process designed to separate the HFSE, including rare earth elements such as neodymium and hafnium, before removing the iron and isolating uranium. Subsequent isolation of Nd and Hf was achieved using established ion exchange chromatography methods. The efficacy of our chemistry was verified by measurements of analytical reference materials – both reference solutions and seawater samples – subjected to the chemical separation methods described. Elution results indicate high yields (> 90%) determined by concentration measurements of a known reference material added to each column. Measurement results for isotopic compositions of seawater (U, Nd) and reference solutions (NIST SRM 960, U) were identical within uncertainty to previously published values. Compositions were identical between solutions (Spex CLMS3, Spex PLND2) that underwent different iron coprecipitation procedures. Isotopic determinations for reference materials JNdi‐1 and NIST SRM 960 measured with the mass spectrometers used in this study were in agreement with universally accepted values for these materials, and indicate high precision.  相似文献   

2.
A two‐step Th isolation protocol, involving micro‐columns of TRU‐Spec extraction chromatography material and AG1 resin, was evaluated. The MC‐ICP‐MS procedure included 232Th tailing characterisation and correction, and calibrator bracketing using an in‐house standard solution (ThS1) to correct for instrumental mass bias and Faraday cup to secondary electron multiplier relative gain. Repeated analyses of reference solutions (UCSC Th ‘A’, WUN, OU Th ‘U’, IRMM‐36) were consistent with published data. Six reference materials (A‐THO, BCR‐2, AGV‐2, BHVO‐2, BE‐N and BIR‐1) were processed. The average 230Th/232Th values obtained for these samples are in excellent agreement with published data. In addition, we report the first 230Th/232Th values for BE‐N and BIR‐1. The intermediate precisions for rock samples ranged from ± 0.24 to ± 0.49% (2 RSD) and were similar to those achieved for synthetic solutions, thereby supporting the overall validity of the chemical separation, data acquisition and reduction procedures. Counting statistics on the 230Th isotope was the most significant source of uncertainty. The intermediate precision of the mean 230Th/232Th for the Th‐depleted BIR‐1 (5.64 × 10?6 ± 0.27%, 2 RSD) is in the range of the analyses of other reference materials analysed in this study.  相似文献   

3.
We report an approach for the accurate and reproducible measurement of boron isotope ratios in natural waters using an MC‐ICP‐MS (Neptune) after wet chemistry sample purification. The sample matrix can induce a drastic shift in the isotopic ratio by changing the mass bias. It is shown that, if no purification is carried out, the direct measurement of a seawater diluted one hundred times will induce an offset of ?7‰ in the isotopic ratio, and that, for the same concentration, the greater the atomic mass of the matrix element, the greater the bias induced. Whatever the sample, it is thus necessary to remove the matrix. We propose a method adapted to water samples allowing purification of 100 ng of boron with a direct recovery of boron in 2 ml of 3% v/v HNO3, which was our working solution. Boron from the International Atomic Energy Agency IAEA‐B1 seawater reference material and from the two groundwater reference materials IAEA‐B2 and IAEA‐B3, was chemically purified, as well as boron from the certified reference material NIST SRM 951 as a test. The reproducibility of the whole procedure (wet chemistry and MC‐ICP‐MS measurement) was ± 0.4‰ (2s). Accuracy was verified by comparison with positive‐TIMS values and with recommended values. Seawater, being homogeneous for boron isotope ratios, is presently the only natural water material that is commonly analysed for testing accuracy worldwide. We propose that the three IAEA natural waters could be used as reference samples for boron isotopes, allowing a better knowledge of their isotopic ratios, thus contributing to the certification of methods and improving the quality of the boron isotopic ratio measurements for all laboratories.  相似文献   

4.
This paper presents a systematic study of major and trace elements and Sm-Nd isotopes in leucogranites closely related to uranium mineralization in the Gaudeanmus area, Namibia. The results illustrate that the uraniferous leucogranites possess high Si_O_2(68.8 wt%–76.0 wt%, average 73.1 wt%) and K(4.05 wt%–7.78 wt%, average 5.94 wt%) contents, and are sub-alkaline and metaluminous to weakly peraluminous, as reflected by A/CNK values of 0.96–1.07 with an average of 1.01. The leucogranites are rich in light rare earth elements(LREE/HREE = 2.53–7.71;(La/Yb)N = 2.14–10.40), have moderate Eu depletion and high Rb/Sr ratios(2.03–5.50 with an average of 4.36); meanwhile, they are enriched in Rb, K, Th, U and Pb, and depleted in Ba, Nb, Ta, and Sr. The ε_(Nd)(t) values of uraninites range from -14.8 to -16.5, and the two-stage Nd model ages are 2.43–2.56 Ga. Detailed elemental and Sm-Nd isotopic geochemical characteristics suggest that the leucogranites were formed in a postorogenic extensional environment. The U-rich pre-Damara basement was the main source of uranium during the primary mineralization event, which is disseminated in leucogranites, whereas the uranium mineralization in veins possibly resulted from remobilization of the primary uranium minerals.  相似文献   

5.
We report an improved procedure for the determination of the platinum‐group elements (PGE) and Re, and Os isotopes from a single sample aliquot by isotope dilution (ID) using inductively coupled plasma‐mass spectrometry (ICP‐MS) and negative thermal ionisation mass spectrometry (N‐TIMS), respectively. A two‐stage column method was used to purify PGE‐Re from their sample matrix and interfering elements (e.g., Mo, Zr and Hf) after Os had been separated by CCl4 solvent extraction. The first column separation step used cation exchange resin (AG50W‐X8) to concentrate PGE‐Re and some potential interfering elements (e.g., Mo, Zr and Hf). In the second step, N‐benzoyl‐N‐phenylhydroxylamine (BPHA) extraction resin was used to separate PGE‐Re from the remaining interfering elements, which all remained strongly absorbed to the resin. The method was used to determine the PGE and rhenium, and Os isotope ratios in a range of geochemical reference materials (TDB‐1, WGB‐1, BHVO‐2 and UB‐N). The obtained results agree well with those previously published. This new method enables PGE‐Re abundances and Os isotopic ratios to be determined on the same sample digestion, and circumvents the problems created by sample heterogeneity when comparing PGE and Re‐Os isotope data.  相似文献   

6.
In this study, a high‐precision method for the determination of Sm and Nd concentrations and Nd isotopic composition in highly depleted ultramafic rocks without a preconcentration step is presented. The samples were first digested using the conventional HF + HNO3 + HClO4 method, followed by the complete digestion of chromite in the samples using HClO4 at 190–200 °C and then complete dissolution of fluoride formed during the HF decomposition step using H3BO3. These steps ensured the complete digestion of the ultramafic rocks. The rare earth elements (REEs) were separated from the sample matrix using conventional cation‐exchange chromatography; subsequently, Sm and Nd were separated using the LN columns. Neodymium isotopes were determined as NdO+, whereas Sm isotopes were measured as Sm+, both with very high sensitivity using single W filaments with TaF5 as an ion emitter. Several highly depleted ultramafic rock reference materials including USGS DTS‐1, DTS‐2, DTS‐2b, PCC‐1 and GSJ JP‐1, which contain extremely low amounts of Sm and Nd (down to sub ng g?1 level), were analysed, and high‐precision Sm and Nd concentration and Nd isotope data were obtained. This is the first report of the Sm‐Nd isotopic compositions of these ultramafic rock reference materials except for PCC‐1.  相似文献   

7.
A simple, single sample preparation involving pressed rock powder pellets was utilised to determine the trace and ultra trace abundances of petrogenetically important elements including high field‐strength elements and REEs by laser ablation‐ICP‐MS. One of the elements predetermined by XRF spectrometry served as an internal standard. The influence of sample preparation parameters (grain size, pellet compactness and amount of binding media) on analytical performance was also investigated, including sample homogeneity issues at the laser sampling scale. Line scanning with a high repetition frequency (20 Hz) and large beam diameter (200 μm) ensured ablation from a larger sample surface area, eliminating issues related to sample heterogeneity. A median grain size of about 10 μm for silicate rock powders was found to be sufficiently representative at this scale of laser sampling. Granitic rocks or samples containing resistant minerals such as zircon needed extra grinding to achieve grain sizes down to < 5 μm for better precision for elements that are concentrated in these phases. Using 137Ba as an internal standard, reasonable accuracies within 15–20% for most of the high mass trace elements were achieved; in the case of low mass elements, it may deviate up to 40%. Precision of measurements rarely exceeded 15% RSD.  相似文献   

8.
A procedure for determining a wide range of chalcophile and siderophile elements in typical crustal rocks using standard addition and ICP‐SFMS (inductively coupled plasma sector field mass spectrometry) is presented. New results for Ga, Ge, Mo, Ag, Cd, In, Sn, Sb, W, Tl and Bi abundances in USGS whole‐rock reference materials AGV‐2, BHVO‐1, BIR‐1, G‐2, GSP‐1 and W‐2 are reported using this analytical procedure. Intermediate precision of means based on multiple dissolved aliquots of each USGS reference material was 10% RSD or better for Ga, Ge, In and Sn in all, and similarly good for Ag, Cd, Sb, Tl and Bi in most reference materials. Poorer intermediate precision of Mo and W measurements in several reference materials is probably due to higher analytical blanks on these elements and powder heterogeneity due to a sulfide‐related nugget effect in the specific case of Mo in GSP‐1. Results for all elements fell within the range of available published data with the exception of Ag, which yielded systematically higher concentrations than found in the literature for five of the six reference materials, likely reflecting interference from unresolved polyatomic species.  相似文献   

9.
Here we report uranium and thorium isotopic ratios and elemental concentrations measured in solid reference materials from the USGS (BHVO‐2G, BCR‐2G, NKT‐1G), as well as those from the MPI‐DING series (T1‐G, ATHO‐G). Specifically created for microanalysis, these naturally‐sourced glasses were fused from rock powders. They cover a range of compositions, elemental concentrations and expected isotopic ratios. The U‐Th isotopic ratios of two powdered source materials (BCR‐2, BHVO‐2) were also characterised. These new measurements via multi‐collector thermal ionisation mass spectrometry and multi‐collector inductively coupled plasma‐mass spectrometry can now be used to assess the relative performance of techniques and facilitate comparison of U‐Th data amongst laboratories in the geoscience community for in situ and bulk analyses.  相似文献   

10.
Concentrations of halogens (fluorine, chlorine, bromine and iodine) were determined in six geochemical reference materials (BHVO‐2, GS‐N, JG‐1, JR‐1, JB‐1b, JB‐2). Halogens were first extracted from powdered samples using a pyrohydrolysis technique, then hydrolysis solutions were analysed by ion chromatography for F and Cl and inductively coupled plasma‐mass spectrometry for Br and I. The detection limits in solutions were 100 μg l?1 for both F and Cl and 10 ng l?1 for Br and I. Considering the extraction procedure, performed on a maximum of 500 mg of sample and producing 100 ml of pyrohydrolysis solution, detection limits in rock samples were 20 mg kg?1 for F and Cl and 2 μg kg?1 for Br and I. The mean analytical errors on the studied composition ranges were estimated at 10 mg kg?1 for F and Cl, 100 μg kg?1 for Br and 25 μg kg?1 for I. The concentration values, based on repeated (generally > 10) sample analysis, were in good agreement generally with published values and narrowed the mean dispersion around mean values. Large dispersions are discussed in terms of samples heterogeneity and contaminations during sample preparation. Basaltic RMs were found to be more suitable for studies of halogen compositions than differentiated rock material, especially granites – the powders of which were heterogeneous in halogens at the 500 mg level.  相似文献   

11.
We present a revised alkali fusion method for the determination of trace elements in geological samples. Our procedure is based on simple acid digestion of powdered low‐dilution (flux : sample ≈ 2 : 1) glass beads where large sample dilution demanded by high total dissolved solids, a main drawback of conventional alkali fusion, could be circumvented. Three geological reference materials (G‐3 granite, GSP‐2 granodiorite and SGD‐1a gabbro) decomposed by this technique and routine tabletop acid digestion were analysed for thirty trace elements using a quadrupole ICP‐MS. Results by conventional acid digestion distinctly showed poor recoveries of Zr, Hf and rare earth elements due to incomplete dissolution of resistant minerals. On the other hand, results obtained by our method were in reasonable agreement with reference data for most analytes, indicating that refractory minerals were efficiently dissolved and volatile loss was insignificant.  相似文献   

12.
This study describes two methods (Procedures‐1 and ‐2) for the direct extraction of Au by an inorganic acid mixture (HClO4‐HBr‐HI‐aqua regia) from complex sample matrices. Standard PTFE jars at 200 °C were used to decompose test portions of 0.5–1 g, with subsequent precise and accurate analysis by ICP‐MS without any other preconcentration or separation. Procedure‐1 decomposed samples effectively without the necessity of leaching with HF and was developed for dust samples from e‐waste (electronic waste) processing; however, testing on geological reference materials showed very good results. The analyses of replicate decompositions (= 5) from both procedures yielded very good precision (< 5% RSD) for most of the reference materials. The accuracy achieved was better than ± 10%, with the exception of NIST SRM 2782 data from Procedure‐1. Two unknown samples of dust from e‐waste processing (P‐1 and VM‐1) exhibited elevated concentrations of Au (21.31–61.64 μg g?1) with precision better than 10% (= 5). The proposed techniques are simple, sensitive and sparing in the use of chemicals, and are designed for a variety of e‐waste dust samples. No significant influences were observed for the predicted spectral interferences on mass 197Au.  相似文献   

13.
A HF‐free sample preparation method was used to purify silicon in twelve geological RMs. Silicon isotope compositions were determined using a Neptune instrument multi‐collector‐ICP‐MS in high‐resolution mode, which allowed separation of the silicon isotope plateaus from their interferences. A 1 μg g‐1 Mg spike was added to each sample and standard solution for online mass bias drift correction. δ30Si and δ29Si values are expressed in per mil (‰), relative to the NIST SRM 8546 (NBS‐28) international isotopic RM. The total variation of δ30Si in the geological reference samples analysed in this study ranged from ‐0.13‰ to ‐0.29‰. Comparison with δ29Si values shows that these isotopic fractionations were mass dependent. IRMM‐17 yielded a δ30Si value of ‐1.41 ± 0.07‰ (2s, n = 12) in agreement with previous data. The long‐term reproducibility for natural samples obtained on BHVO‐2 yielded δ30Si = ‐0.27 ± 0.08‰ (2s, n = 42) on a 12 month time scale. An in‐house Si reference sample was produced to check for the long‐term reproducibility of a mono‐elemental sample solution; this yielded a comparable uncertainty of ± 0.07‰ (2s, n = 24) over 5 months.  相似文献   

14.
The influence of ablation cell geometry (Frames single‐ and HelEx two‐volume cells) and laser wavelength (198 and 266 nm) on aerosols produced by femtosecond laser ablation (fs‐LA) were evaluated. Morphologies, iron mass distribution (IMD) and 56Fe/54Fe ratios of particles generated from magnetite, pyrite, haematite and siderite were studied. The following two morphologies were identified: spherules (10–200 nm) and agglomerates (5–10 nm). Similarity in IMD and ablation rate at 198 and 266 nm indicates similar ablation mechanisms. 56Fe/54Fe ratios increased with aerodynamic particle size as a result of kinetic fractionation during laser plasma plume expansion, cooling and aerosol condensation. The HelEx cell produces smaller particles with a larger range of 56Fe/54Fe ratios (1.85‰) than particles from the Frames cell (1.16‰), but the bulk aerosol matches the bulk substrate for both cells, demonstrating stoichiometric fs‐LA sampling. IMD differences are the result of faster wash out of the HelEx cell allowing less time for agglomeration of small, low‐δ 56Fe particles with larger, high‐δ 56Fe particles in the cell. Even with a shorter ablation time, half the total Fe ion intensity, and half the ablation volume, the HelEx cell produced Fe isotope determinations for magnetite that were as precise as the Frames cell, even when the latter included an aerosol‐homogenising mixing chamber. The HelEx cell delivered a more constant stream of small particles to the ICP, producing a more stable Fe ion signal (0.7% vs. 1.5% RSE for 56Fe in a forty‐cycle single analysis), constant instrumental mass bias and thus a more precise measurement.  相似文献   

15.
The ‘Appropriate Sampling for Optimised Measurement’ (ASOM) approach considers measurement to be the focus of the sampling process, and sampling to be only the first part of the measurement process. To achieve ASOM, the uncertainty of measurements, including its contribution from sampling, needs to be estimated and optimised in order to achieve fitness‐for‐purpose. Such samples are then ‘sufficiently’ representative. The ‘Theory of Sampling’ (TOS) focuses on the processes of primary sampling and sample preparation and assumes that samples are ‘representative’ if they are correctly prepared by nominally ‘correct’ protocols. It defines around ten sampling ‘errors’, which are either modelled or minimised to improve sampling quality. It is argued that the ASOM approach is more effective in achieving appropriate measurement quality than in applying TOS to just the first part of the measurement process. The comparison is made less effective by the different objectives, scopes, terminology and assumptions of the two approaches. ASOM can be applied to in situ materials that are too variable to be modelled accurately, or where sources of uncertainty are unsuspected. The proposed integration of ASOM with TOS (Esbensen and Wagner 2014, Trends in Analytical Chemistry, 57, 93–106) is therefore effectively impossible. However, some TOS procedures can be useful within the ASOM approach.  相似文献   

16.
Geochemical studies of geological samples require the precise determination of their major and trace element contents and, when measured, of their isotopic compositions. It is now commonly accepted that the accuracy and precision of geochemical analyses are best estimated by the concomitant analysis of international reference materials run as unknown samples. Although the composition of a wide selection of basalts is relatively well constrained, this is far from being the case for sedimentary materials. We present here a comprehensive set of major and trace element data as well as Nd, Hf, Sr and Pb isotopic compositions for thirteen commonly used international reference materials – eight magmatic rocks (BHVO‐2, BR, BE‐N, BR 24, AGV‐1, BIR‐1, UB‐N, RGM‐1) and five sediments (JLk‐1, JSd‐1, JSd‐2, JSd‐3, LKSD‐1). We determined the concentrations of over forty elements in the magmatic rocks together with Sr, Nd, Hf and Pb isotopic compositions. Our trace element results were both accurate (difference ≤ 3%) and precise (reproducibility at 1s ≤ 3%) and the isotopic results were very similar to other published values. In contrast, we observed a significant chemical and isotopic variability in the sedimentary materials, which we attribute to mineral heterogeneities in the powders. Despite the limitation imposed by this heterogeneity, our work presents a complete set of data determined with a precision not yet achieved in the literature for sedimentary material. We also provide the first Nd, Hf and Pb isotopic measurements for the five sediments, which are commonly used by the geochemical community. Our study of both basalt and sediment reference materials represents a comprehensive and self‐consistent set of geochemical data and can therefore be considered as a reference database for the community.  相似文献   

17.
This study presents an experimental procedure to fabricate high‐purity silica glass containing a selected element at a specified mass fraction. The procedure was used to prepare glasses doped with trace‐level mass fractions of Ti with the goal of improving analytical confidence when measuring trace elements in quartz. Systematic tests were performed to determine the ideal conditions and procedures for doping nanoporous silica gel with the highest efficiency of dopant recovery. Silica gel was cleaned in concentrated HCl, immersed in a non‐polar doping medium at a controlled pH and doped with precise quantities of ICP‐MS standard solution. Using liquids composed of longer chain molecules as the doping medium diminishes recovery, suggesting that large molecules could obstruct nanopores to inhibit capillary uptake of the dopant. A control experiment using crystalline quartz reinforced the effectiveness of nanoporous silica gel for doping with trace‐level precision. Layered aggregates of silica gel doped with different Ti mass fractions were hot‐pressed to create multi‐layered reference materials that were analysed with multiple techniques at a variety of spatial scales. Analyses at the intra‐grain scale (cathodoluminescence scanning electron microscopy, electron probe microanalysis), at the single grain scale (SIMS), at the sample layer scale (EPMA, laser ablation‐ICP‐MS) and at the bulk scale (ICP‐OES) demonstrated acceptable homogeneity at sample volumes characteristic of most microanalysis techniques and show that nanoporous silica gel holds promise as a highly retentive doping substrate for preparing reference materials for laser‐, electron‐ and ion‐beam microanalysis.  相似文献   

18.
An organic solvent‐free two‐step column procedure is presented that provided robust, high yield and super clean separation of Li from silicate rock sample matrices. The measured δ7Li value for BHVO‐2 of +4.29 ± 0.23‰ (1s) is comparable with the reported values. The δ7Li values for GSJ JP‐1 (+3.14 ± 0.41‰, 1s) and USGS DTS‐2 (+4.91 ± 0.34‰, 1s) presented here provide new reference values for ultramafic rock reference materials.  相似文献   

19.
Over 1400 electron probe and 700 ion probe microanalyses were performed on eleven mineral separates to evaluate their potential as reference materials for in situ Li isotopic determination. Our results suggest the homogenous distributions of major elements, Li and its isotopes for each sample. Hence, these samples are suitable to be used as reference materials for in situ measurements of Li abundance and Li isotopes by secondary ion mass spectrometry (SIMS) or laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS). These samples have the advantage of mitigating probable matrix effects during calibration owing to the wide range of compositions. The effect of composition on the δ7Li of olivine measured by SIMS is a linear function of composition, with δ7Li increasing by 1.0‰ for each mole per cent decrease in forsterite component.  相似文献   

20.
The commonly used, but no longer available, reference materials NIST SRM 976 (Cu) and ‘JMC Lyon’ (Zn) were calibrated against the new reference materials ERM®‐AE633, ERM®‐AE647 (Cu) and IRMM‐3702 (Zn), certified for isotope amount ratios. This cross‐calibration of new with old reference materials provides a continuous and reliable comparability of already published with future Cu and Zn isotope data. The Cu isotope amount ratio of NIST SRM 976 yielded δ65/63Cu values of ?0.01 ± 0.05‰ and ?0.21 ± 0.05‰ relative to ERM®‐AE633 and ERM®‐AE647, respectively, and a δ66/64ZnIRMM‐3702 value of ?0.29 ± 0.05‰ was determined for ‘JMC Lyon’. Furthermore, we separated Cu and Zn from five geological reference materials (BCR‐2, BHVO‐2, BIR‐1, AGV‐1 and G‐2) using a two‐step ion‐exchange chromatographic procedure. Possible isotope fractionation of Cu during chromatographic purification and introduction of resin‐ and/or matrix‐induced interferences were assessed by enriched 65Cu isotope addition. Instrumental mass bias correction for the isotope ratio determinations by MC‐ICP‐MS was performed using calibrator‐sample bracketing with internal Ni doping for Cu and a double spike approach for Zn. Our results for the five geological reference materials were in very good agreement with literature data, confirming the accuracy and applicability of our analytical protocol.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号