首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new base isolation system using scrap tire rubber pads (STRP) has been introduced for seismic mitigation of ordinary residential buildings. The rubber and the steel reinforcing cords used in manufacturing the tire are the alternative materials of the proposed base isolation system. The steel reinforcing cords represent the steel plates used in conventional laminated rubber bearings. These steel reinforcing cords shall prevent the lateral bulging of the rubber bearing. The proposed base isolation system has no bonding between the superstructure and the foundation beam which allows for rollover deformation. In the first part of the study, the STRP layers were just stacked one on top of another without applying the adhesive. This paper presents loading test as well as finite element analysis (FE analysis) of strip STRP isolators that are subjected to any given combination of static vertical and lateral loads. The results of the static vertical and horizontal loading test conducted on STRP isolators were used to calculate the mechanical properties of the isolators, including stiffness and damping values. The load–displacement relationship of STRP isolators were compared between experimental and FE analysis results and the results were found to be in close agreement. The stress state within the STRP isolators was also analyzed in order to estimate the maximum stress demand in the rubber and steel reinforcing cords. These STRP isolators have several advantages over conventional laminated rubber bearings including superior damping properties, lower incurred cost, light weight and easily available material. This study suggests that using the STRP as low cost base isolation device for ordinary residential buildings is feasible.  相似文献   

2.
本文提出一种评估同一地区不同类型结构的抗震投入产出效益的新指标,即结构价值损失比率。利用"5·12"汶川地震后对甘肃陇南的学校、住宅、办公、医院和生命线工程等9类建筑物的调查统计结果,研究了震害等级、经济损失与结构抗震初始投入之间的关系,建立了结构价值损失比率与结构初始投入之间的关系和高烈度区危房率与地震地面运动峰值之间的关系。对比分析了土-木组合、砖-木组合、砖砌体结构、非隔震框架结构和基础隔震结构等不同类型结构的抗震性能,并与实际鉴定的震害等级相比较。利用结构价值损失比率,初步说明了采用隔震新技术结构的减灾效益。  相似文献   

3.
In many applications of seismic isolation, such as in high‐rise construction, lightweight construction, and structures with large height‐to‐width aspect ratios, significant tension forces can develop in bearings, raising concerns about the possible rupture of elastomeric bearings and the uplift of sliding bearings. In this paper, a novel tension‐resistant lead plug rubber bearing (TLRB) with improved tension‐resisting capabilities is developed and experimentally and numerically assessed. This TLRB consists of a common lead plug rubber bearing (LRB) and several helical springs. After describing the theory underlying the behavior of the TLRB, the mechanical properties of reduced‐scale prototype bearings are investigated through extensive horizontal and vertical loading tests. The test results indicate that TLRBs can improve the shear stiffness and tension resistance capacity even under significant tensile loads. A series of shaking table tests on scaled models of high‐rise buildings with different aspect ratios were conducted to investigate the dynamic performance of the TLRB and the seismic responses of base‐isolated high‐rise buildings. Three different cases were considered in the shaking table tests: a fixed base condition and the use of TLRB and LRB isolation systems. The results of the shaking table test show that (a) base‐isolated systems are effective in reducing the structural responses of high‐rise buildings; (b) an isolated structure's aspect ratio is an important factor influencing its dynamic response; (c) TLRBs can endure large tensile stresses and avoid rupture on rubber bearings under strong earthquakes; and (d) the experimental and numerical results of the responses of the models show good agreement. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

4.
Base isolation has been established as the seismic design approach of choice when it comes to protecting nonstructural contents. However, while this protection technology has been widely shown to reduce seismic demands on attached oscillatory equipment and contents (EC), its effectiveness in controlling the response of freestanding EC that are prone to sliding has not been investigated. This study examines the seismic behavior of sliding EC inside base‐isolated buildings subjected to broadband ground motions. The effect of isolation system properties on the response of sliding EC with various friction coefficients is examined. Two widely used isolation models are considered: viscously damped linear elastic and bilinear. The study finds isolation to be generally effective in reducing seismic demands on sliding EC, but it also exposes certain situations where isolation in fact increases demands on EC, most notably for low friction coefficients and high earthquake intensities. Damping at the isolation level is effective in controlling the EC sliding displacements, although damping over about 20% is found to be superfluous. The study identifies a physically motivated dimensionless intensity measure and engineering demand parameter for sliding equipment in base‐isolated buildings subjected to broadband ground motions. Finally, the paper presents easy‐to‐use design fragility curves and an example that illustrates how to use them. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
In order to achieve a low isolation frequency, elastomeric bearings used for base isolation of buildings usually have low shear rigidity which leads to a significant reduction in the buckling load. The effects of compression load on the bearing behaviour are therefore an important consideration. A study of seismic response of base isolated buildings is presented in this paper, fully accounting for the P-Δ effects of isolation bearings. An analytical procedure is formulated that treats separately the superstructure and the supporting bearings and assembles the governing equations via the interaction forces at the base deck. The resulting equations are then solved step-by-step numerically. Numerical results obtained for a base isolated five-storey shear building show that neglecting the P-Δ effects can lead to considerable errors in the computed seismic response when the buckling safety factor of bearings is low.  相似文献   

6.
This paper reports on an investigation of the seismic response of base-isolated reinforced concrete buildings, which considers various isolation system parameters under bidirectional near-fault and far-fault motions. Three-dimensional models of 4-, 8-, and 12-story base-isolated buildings with nonlinear effects in the isolation system and the superstructure are investigated, and nonlinear response history analysis is carried out. The bounding values of isolation system properties that incorporate the aging effect of isolators are also taken into account, as is the current state of practice in the design and analysis of base-isolated buildings. The response indicators of the buildings are studied for near-fault and far-fault motions weight-scaled to represent the design earthquake (DE) level and the risk-targeted maximum considered earthquake (MCER) level. Results of the nonlinear response history analyses indicate no structural damage under DE-level motions for near-fault and far-fault motions and for MCER-level far-fault motions, whereas minor structural damage is observed under MCER-level near-fault motions. Results of the base-isolated buildings are compared with their fixed-base counterparts. Significant reduction of the superstructure response of the 12-story base-isolated building compared to the fixed-base condition indicates that base isolation can be effectively used in taller buildings to enhance performance. Additionally, the applicability of a rigid superstructure to predict the isolator displacement demand is also investigated. It is found that the isolator displacements can be estimated accurately using a rigid body model for the superstructure for the buildings considered.  相似文献   

7.
The seismic response of light secondary systems in a building is dependent on the response of the primary structural system to the seismic ground motion with the result that very high accelerations can be induced in such secondary systems. This response can be reduced through the use of aseismic base isolation which is a design strategy whereby the entire building can be decoupled from the damaging horizontal components of seismic ground motion by the use of some form of isolation system. The paper presents a theoretical analysis of the response of light equipment in isolated structures and a parallel experimental programme both of which show that the use of base isolation can not only attenuate the response of the primary structural system but also reduce the response of secondary systems. Thus, the design of equipment and piping in a base-isolated building is very much simpler than that for a conventionally founded structure: inelastic response and equipment-structure interaction need not be considered and multiple support response analysis is rendered unnecessary. Although an isolation system with linear elastic bearings can reduce the acceleration of the structure, it may be accompanied by large relative displacements between the structure and the ground. A system using lead-rubber hysteretic bearings, having a force-displacement relation which is approximately a bilinear loop, can reduce these displacements. A parallel experimental programme was carried out to investigate the response of light equipment in structures isolated using lead-rubber bearings. The experimental results show that these bearings can dissipate energy and limit the displacement and acceleration of the structure but are less effective in reducing the accelerations in the internal equipment. The results of both the analysis and the tests show that base isolation is a very effective method for the seismic protection of light equipment items in buildings.  相似文献   

8.
Shear building representations of seismically isolated buildings   总被引:2,自引:0,他引:2  
Seismic isolation, with its capability of reducing floor accelerations and interstory drifts simultaneously, is recognized as an earthquake resistant design method that protects contents of a building along with the building itself. In research studies, superstructures of seismically isolated buildings are commonly modeled as idealized shear buildings. Shear building representation corresponds to an idealized structure where the beams are infinitely stiff in flexure and axially inextensible; columns are axially inextensible; and rigid floors are supported on these columns. Although it is more convenient to model and analyze a shear building, such an idealization may influence the seismic responses of seismically isolated buildings. This study presents a comparison of the seismic performances of seismically isolated buildings with superstructures modeled as shear buildings to those with full three dimensional superstructures. Both linear and nonlinear base isolation systems with different isolation periods and superstructures with different number of stories are considered.  相似文献   

9.
Base‐isolation is regarded as one of the most effective methods for protecting the structural and nonstructural building elements from design level horizontal earthquake ground shaking. However, base‐isolation as currently practiced does not offer unlimited protection for these buildings, especially when the ground shaking includes a strong vertical component. The vulnerability of nonstructural systems in a base‐isolated building was made evident during recent shake table testing of a full‐scale five‐story base‐isolated steel moment frame where nonstructural system damage was observed following tests including vertical excitation. Past research efforts have attempted to achieve 3D isolation of buildings and nuclear structures by concentrating both the horizontal and vertical flexibility at the base of the building that are either quite limited or not economically viable. An approach whereby the vertical flexibility is distributed up the height of the building superstructure to passively reduce vertical acceleration demands in base‐isolated buildings is presented. The vertical flexibility is achieved by placing laterally restrained elastomeric ‘column’ bearings at one or more floor levels along the height of the building. To broadly investigate the efficacy of the vertically distributed flexibility concept and the trade‐off between mitigation and cost, a multi‐objective optimization study was conducted considering 3‐story, 9‐story, and 20‐story archetype buildings that aimed to minimize the median peak vertical floor acceleration demands and to minimize the direct cost of column bearings. Based on the results of the optimization study, a practical rule for determining the number of levels and locations of column bearings is proposed and evaluated. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
Effectiveness of a new semiactive independently variable stiffness (SAIVS) device in reducing seismic response of sliding base isolated buildings is evaluated analytically and experimentally. Through analytical and experimental study of force—displacement behaviour of the SAIVS device, it is shown that the device can vary stiffness continuously and smoothly between minimum and maximum stiffness. Passive sliding base isolation systems reduce interstorey drifts and superstructure accelerations, but with increased base displacements, which is undesirable, under large velocity near fault pulse type earthquakes. It is a common practice to incorporate non‐linear passive dampers into the isolation system to reduce bearing displacements. Incorporation of passive dampers, however, may result in increased superstructure accelerations and drifts; while, properly designed passive dampers can be beneficial. A viable alternative is to use semiactive variable stiffness systems, which can vary the period of the sliding base isolated buildings in real time, to simultaneously reduce bearing displacements and superstructure responses further than the passive systems, which deserves investigation. This study investigates the performance of a 1:5 scaled smart sliding base isolated building model equipped with the SAIVS device analytically and experimentally, under near fault earthquakes, by developing a new moving average non‐linear tangential stiffness control algorithm for control of the SAIVS device. The SAIVS device reduces bearing displacements further than the passive cases, while maintaining isolation level forces and superstructure responses at the same level as the passive minimum stiffness case, indicating the significant potential of the SAIVS system. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

11.
A damage detection algorithm of structural health monitoring systems for base‐isolated buildings is proposed. The algorithm consists of the multiple‐input multiple‐output subspace identification method and the complex modal analysis. The algorithm is applicable to linear and non‐linear systems. The story stiffness and damping as damage indices of a shear structure are identified by the algorithm. The algorithm is further tuned for base‐isolated buildings considering their unique dynamic characteristics by simplifying the systems to single‐degree‐of‐freedom systems. The isolation layer and the superstructure of a base‐isolated building are treated as separate substructures as they are distinctly different in their dynamic properties. The effectiveness of the algorithm is evaluated through the numerical analysis and experiment. Finally, the algorithm is applied to the existing 7‐story base‐isolated building that is equipped with an Internet‐based monitoring system. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

12.
The mid‐story isolation design method is recently gaining popularity for the seismic protective design of buildings located in the areas of high population. In a mid‐story isolated building, the isolation system is incorporated into the mid‐story rather than the base of the building. In this paper, the dynamic characteristics and seismic responses of mid‐story isolated buildings are investigated using a simplified three‐lumped‐mass structural model for which equivalent linear properties are formulated. From the parametric study, it is found that the nominal frequencies of the superstructure and the substructure, respectively, above and below the isolation system have significant influences on the isolation frequency and equivalent damping ratio of a mid‐story isolated building. Moreover, the mass and stiffness of the substructure are of greater significance than the superstructure in affecting the dynamic characteristics of the isolated building. Besides, based on the response spectrum analysis, it is noted that the higher mode responses may contribute significantly to the story shear force of the substructure. Consequently, the equivalent lateral force procedure of design codes should carefully include the effects of higher modes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
This paper presents a detailed study on feasibility of un‐bonded fiber reinforced elastomeric isolator (U‐FREI) as an alternative to steel reinforced elastomeric isolator (SREI) for seismic isolation of un‐reinforced masonry buildings. Un‐reinforced masonry buildings are inherently vulnerable under seismic excitation, and U‐FREIs are used for seismic isolation of such buildings in the present study. Shake table testing of a base isolated two storey un‐reinforced masonry building model subjected to four prescribed input excitations is carried out to ascertain its effectiveness in controlling seismic response. To compare the performance of U‐FREI, same building is placed directly on the shake table without isolator, and fixed base (FB) condition is simulated by restraining the base of the building with the shake table. Dynamic response characteristic of base isolated (BI) masonry building subjected to different intensities of input earthquakes is compared with the response of the same building without base isolation system. Acceleration response amplification and peak response values of test model with and without base isolation system are compared for different intensities of table acceleration. Distribution of shear forces and moment along the height of the structure and response time histories indicates significant reduction of dynamic responses of the structure with U‐FREI system. This study clearly demonstrates the improved seismic performance of un‐reinforced masonry building model supported on U‐FREIs under the action of considered ground motions. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

14.
改进的基础隔震结构地震作用简化计算方法   总被引:3,自引:0,他引:3  
在《建筑抗震设计规范》(GB50011-2001)关于隔震结构的简化计算方法中,水平向减震系数的表达式和定义有些不符,假定的隔震结构地震作用分布规律也与实际情况略有出入。本文基于水平向减震系数的定义和实际隔震结构的地震作用分布规律提出了一种改进的隔震结构水平向减震系数、隔震结构总地震作用、隔震结构上部地震作用分布的计算方法,并提出了总水平地震作用减震系数的新概念。本文提出的改进方法具有表达准确、物理意义明确的特点。将本文提出的改进算法计算结果与时程分析计算结果比较,结果显示,改进方法的计算结果与时程分析结果接近,且分布规律一致。  相似文献   

15.
本文研究土与结构相互作用(SSI)对多层及中高层基础隔震建筑地震需求及隔震效率的影响规律,隔震层采用LRB铅芯橡胶与LNR普通橡胶隔震支座组合,就我国现行《建筑抗震设计规范》(GB50011-2010)中软土场地设置隔震层问题做探讨。提出土与基础隔震结构相互作用的简化计算模型,对不同场地及隔震设计目标下的多层及中高层基础隔震结构进行时程分析。研究表明:软土场地基础隔震建筑隔震层的有效隔震效率相对于硬土场地有所下降,必须通过设置具有一定规格的LRB支座来满足隔震目标。本文给出了铅芯橡胶支座极限变形需求随建筑层高及隔震目标变化的规律。  相似文献   

16.
A base isolation system composed of low‐damping isolation bearings and magnetorheological (MR) fluid dampers is described. The MR fluid changes its properties under the influence of a magnetic field resulting in a damper with characteristics that may be modified in real time. This feature enables optimal control under changing excitations in a stable and cost‐effective manner. The voltage is applied according to a selective control strategy. According to the proposed approach the dampers are activated only within a given range of the base displacements. The selective control improves the efficiency of the system and significantly reduces the control forces required for an optimal structural behaviour. Models of five‐ and eight‐storey buildings are used to study the efficiency of the proposed system. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

17.
18.
Base isolation is a well known technology that has been proven to reduce structural response to horizontal ground accelerations. However, vertical response still remains a topic of concern for base‐isolated buildings, perhaps more so than in fixed‐base buildings as isolation is often used when high performance is required. To investigate the effects of vertical response on building contents and nonstructural components, a series of full‐scale shaking table tests were conducted at the E‐Defense facility in Japan. A four‐story base‐isolated reinforced concrete building was outfitted as a medical facility with a wide variety of contents, and the behavior of the contents was observed. The rubber base isolation system was found to significantly amplify vertical accelerations in some cases. However, the damage caused by the vertical ground motions was not detrimental when peak vertical floor accelerations remained below 2 g with three exceptions: (1) small items placed on shelves slid or toppled; (2) objects jumped when placed on nonrigid furniture, which tended to increase the response; and (3) equipment with vertical eccentricities rocked and jumped. In these tests, all equipment and nonstructural components remained functional after shaking. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
本文在对多次地震震害资料进行研究分析的基础上,对其中符合现代隔震原理或思想的震而不倒的现象进行了分析,并将其划归为5类:(1)柱基“铰结”隔震消能;(2)结构底部柔性防潮层或薄弱层滑移隔震;(3)殿基、墙基或塔基滑移隔震消能;(4)柔性地基隔震消能;(5)采用长周期柔性结构。针对每一类情况分别进行了剖析,并列举了一系列震害实例。最后对现代隔震技术发展中所存在的问题及发展方向提出了看法。  相似文献   

20.
The development of an efficient energy-dissipating mechanism that works in conjunction with laminated elastomeric bearings in order to reduce the lateral deformation of the isolation system has always been a goal of base isolation research. Theoretically, this deformation will be reduced to the minimum if damping augmentation of the isolation system can reach a critical value. However, augmenting the isolation damping may cause some unwanted side effects. The purpose of this paper is to study the influence of isolation damping on the seismic response of heavily damped base-isolated buildings. The base isolation system is assumed to be linearly viscoelastic and is analysed using the complex mode method. Solutions derived by using perturbation techniques for a two-degree-of-freedom system and the computer simulation for a multiple-degree-of-freedom system reveal that augmenting the isolation damping can reduce efficiently the deformation of the isolation system, but at the price of increasing the high-frequency vibration in the superstructure. When the damping ratio of the isolation system is beyond some level, increasing the isolation damping will enlarge the extreme values of the base and superstructural accelerations. It is also found that approximate solutions derived from the use of classical damping and classical modes of vibration in the seismic analysis of heavily damped base isolation systems can be substantially in error.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号