首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chen X  Yin Y 《Ground water》2004,42(1):92-96
In the analysis of streamflow depletion, the Hunt (1999) solution has an important advantage because it considers a partially penetrating stream. By extending the Hunt drawdown solution, this paper presents semianalytical solutions for gaining streams that evaluate the induced stream infiltration and base flow reduction separately. Simulation results show that for a given deltah (the initial hydraulic head difference between stream and aquifer beneath the channel), the base flow reduction is in direct proportion to the product of streambed leakage (lambda) and the distance between pumping well and stream (L), and the induced stream infiltration is in inverse proportion to lambdaL. Deltah has a significant effect on the ratio of stream infiltration to base flow reduction. The results from the semianalytical solutions agree well with those from MODFLOW simulations. The semianalytical solutions are useful in the verification of numerical simulations and in the analysis of stream-aquifer interactions where water quantity or quality is concerned.  相似文献   

2.
Butler JJ  Zhan X  Zlotnik VA 《Ground water》2007,45(2):178-186
The impact of ground water pumping on nearby streams is often estimated using analytic models of the interconnected stream-aquifer system. A common assumption of these models is that the pumped aquifer is underlain by an impermeable formation. A new semianalytic solution for drawdown and stream depletion has been developed that does not require this assumption. This solution shows that pumping-induced flow (leakage) through an underlying aquitard can be an important recharge mechanism in many stream-aquifer systems. The relative importance of this source of recharge increases with the distance between the pumping well and the stream. The distance at which leakage becomes the primary component of the pumping-induced recharge depends on the specific properties of the aquifer, aquitard, and streambed. Even when the aquitard is orders of magnitude less transmissive than the aquifer, leakage can be an important recharge mechanism because of the large surface area over which it occurs. Failure to consider aquitard leakage can lead to large overestimations of both the drawdown produced by pumping and the contribution of stream depletion to the pumping-induced recharge. The ramifications for water resources management and water rights adjudication can be significant. A hypothetical example helps illustrate these points and demonstrates that more attention should be given to estimating the properties of aquitards underlying stream-aquifer systems. The solution presented here should serve as a relatively simple but versatile tool for practical assessments of pumping-induced stream-aquifer interactions. However, this solution should not be used for such assessments without site-specific data that indicate pumping has induced leakage through the aquitard.  相似文献   

3.
Commonly used analytical approaches for estimation of pumping-induced drawdown and stream depletion are based on a series of idealistic assumptions about the stream-aquifer system. A new solution has been developed for estimation of drawdown and stream depletion under conditions that are more representative of those in natural systems (finite width stream of shallow penetration adjoining an aquifer of limited lateral extent). This solution shows that the conventional assumption of a fully penetrating stream will lead to a significant overestimation of stream depletion (> 100%) in many practical applications. The degree of overestimation will depend on the value of the stream leakance parameter and the distance from the pumping well to the stream. Although leakance will increase with stream width, a very wide stream will not necessarily be well represented by a model of a fully penetrating stream. The impact of lateral boundaries depends upon the distance from the pumping well to the stream and the stream leakance parameter. In most cases, aquifer width must be on the order of hundreds of stream widths before the assumption of a laterally infinite aquifer is appropriate for stream-depletion calculations. An important assumption underlying this solution is that stream-channel penetration is negligible relative to aquifer thickness. However, an approximate extension to the case of nonnegligible penetration provides reasonable results for the range of relative penetrations found in most natural systems (up to 85%). Since this solution allows consideration of a much wider range of conditions than existing analytical approaches, it could prove to be a valuable new tool for water management design and water rights adjudication purposes.  相似文献   

4.
This study presents analytical solutions of the three‐dimensional groundwater flow to a well in leaky confined and leaky water table wedge‐shaped aquifers. Leaky wedge‐shaped aquifers with and without storage in the aquitard are considered, and both transient and steady‐state drawdown solutions are derived. Unlike the previous solutions of the wedge‐shaped aquifers, the leakages from aquitard are considered in these solutions and unlike similar previous work for leaky aquifers, leakage from aquitards and from the water table are treated as the lower and upper boundary conditions. A special form of finite Fourier transforms is used to transform the z‐coordinate in deriving the solutions. The leakage induced by a partially penetrating pumping well in a wedge‐shaped aquifer depends on aquitard hydraulic parameters, the wedge‐shaped aquifer parameters, as well as the pumping well parameters. We calculate lateral boundary dimensionless flux at a representative line and investigate its sensitivity to the aquitard hydraulic parameters. We also investigate the effects of wedge angle, partial penetration, screen location and piezometer location on the steady‐state dimensionless drawdown for different leakage parameters. Results of our study are presented in the form of dimensionless flux‐dimensionless time and dimensionless drawdown‐leakage parameter type curves. The results are useful for evaluating the relative role of lateral wedge boundaries and leakage source on flow in wedge‐shaped aquifers. This is very useful for water management problems and for assessing groundwater pollution. The presented analytical solutions can also be used in parameter identification and in calculating stream depletion rate and volume. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
The Theis equation has been widely used to study the transient movement of groundwater as a result of pumping in a confined aquifer. It is well known that the observed drawdown at early times has an obvious departure from the theoretical drawdown based on the Theis equation. The Theis equation was derived under the assumption that total stress in the aquifer was constant and the mechanical behavior of the confining unit was neglected. However, most geological formations, especially those which are well consolidated, have rigidity and therefore may bend like a plate to a certain extent. The increase in the effective stress in the aquifer due to pumping may not contribute entirely to the compression of the aquifer, but may be partially cancelled out by bending of the overlying aquitard. This means only a part of the total stress is used to compact the aquifer, or the aquifer cannot produce as much water as estimated from the Theis equation. This paper investigated the impact of the bending effect of the confining unit on drawdown. An analytical model which couples flow in the aquifer and bending of the confining unit was presented. The theory is based on elastic plates and solutions were given to the drawdown of groundwater level and deflection of the overlying formation. The drawdown estimated from the new equation was compared with that from the Theis equation. It can be concluded that drawdown from the Theis equation is less than the drawdown predicted by including the bending effect of the confining unit. Both a hypothetical example and a field pumping test in Shandong Province, China, were used to demonstrate the bending effect of the confining unit in the analysis of pumping test data. This paper demonstrated that the initial disagreement between observed drawdown and the Theis solution could be caused by the bending effect of the confining unit, a phenomenon not well addressed in traditional pumping test analysis. A quantitative understanding of this phenomenon can provide improved guidelines for analyzing drawdown data in a confined aquifer.  相似文献   

6.
A two‐dimensional semi‐analytical solution to analyse stream–aquifer interactions in a coastal aquifer where groundwater level responds to tidal effects is presented. The conceptual model considered is a two‐dimensional subsurface system with stream and coastline boundaries at right angles. The dimensional and non‐dimensional boundary value problems were solved for water level in the aquifer by successive application of Laplace and Fourier transform techniques, and the results were obtained by numerical inversion of the transformed solution. The solution was then verified by reducing the solutions to one‐dimensional known problems and comparing the results with those from previous studies. Hypothetical examples were used to examine the characteristics of water‐level variations due to the variations in stream stage and the fluctuations in tide level. Sensitivity analysis indicated that streambed leakance has no influence over the amplitude of groundwater fluctuations, but that the effect of stream stage increases with increasing leakance. Little difference was observed in the water level for different aquifer penetration ratios with narrow stream width. Increases in streambed leakance caused increases in the effect of aquifer penetration by the stream on the water level. An increased specific yield value resulted in decreased amplitude of water fluctuations and mean water level, and showed that water‐level variations due to stream and tidal boundaries are sensitive to specific yield. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

7.
Steady flow to a well near a stream with a leaky bed   总被引:2,自引:0,他引:2  
Bakker M  Anderson EI 《Ground water》2003,41(6):833-840
We present an explicit analytic solution for steady, two-dimensional ground water flow to a well near a leaky streambed that penetrates the aquifer partially. Leakage from the stream is approximated as occurring along the centerline of the stream. The problem domain is infinite and pumping on one side of the stream induces flow on the other side. The solution includes the effects of uniform flow in the far field and a sloping hydraulic head in the stream. We use the solution to investigate the interaction between ground water and surface water in the stream, the effects of pumping on the opposite side of the stream, and the effects of the leaky streambed on the capture zone envelope of the well. We develop a relationship between parameters such that the pumping well will not capture water from the stream, or from the opposite side of the stream. When the discharge of the well is large enough to capture water from the stream, the shape of the capture zone envelope depends on flow conditions on the side of the stream opposite the well.  相似文献   

8.
Hu LT  Chen CX 《Ground water》2008,46(4):642-646
Concurrent existence of confined and unconfined zones of an aquifer can arise owing to ground water withdrawal by pumping. Using Girinskii's potential function, Chen (1974, 1983) developed an approximate analytical solution to analyze transient ground water flow to a pumping well in an aquifer that changes from an initially confined system to a system with both unconfined and confined regimes. This article presents the details of the Chen model and then compares it with the analytical model developed by Moench and Prickett (1972) for the same problem. Hypothetical pumping test examples in which the aquifer undergoes conversion from confined to water table conditions are solved by the two analytical models and also a numerical model based on MODFLOW. Comparison of the results suggests that the solutions of the Chen model give better results than the Moench and Prickett model except when the radial distance is very large or aquifer thickness is large compared with drawdown.  相似文献   

9.
《Advances in water resources》2007,30(4):1016-1026
We have proved that the Hantush’s model [Hantush MS. Wells near streams with semipervious beds. J Geophys Res 1965;70:2829–38] in a half-domain can be extended to a whole-domain and becomes identical to that of Hunt [Hunt B. Unsteady stream depletion from ground water pumping. Ground Water 1999;37(1):98–102] for a shallow and infinitely narrow stream, provided that the Dupuit assumption is adopted. This proof helps correct a false concept that regards the Hantush’s model as less useful because of its fully penetrating stream assumption. This study deals with interaction of an aquifer with two parallel streams based on the Hantush’s model. Semi-analytical solutions are obtained based on rigorous mass conservation requirement by maintaining continuity of flux and head along the aquifer–streambed boundaries. This study shows that the hydraulic conductivity ratio of the two streambeds appears to be the most important factor controlling the stream–aquifer interaction, followed by a less important role played by the thickness ratio of the two streambeds. When the low-permeability streambeds do not exist, the steady-state stream depletion from one stream is linearly proportional to the ratio of the shortest distance from the pumping well to the other stream over the shortest distance between the two streams. When the low-permeability streambeds are presented, similar conclusion can be drawn except that the stream depletion now also strongly depends on the hydraulic conductivity ratio of the two streambeds. When the values of the hydraulic conductivity of the two streambeds are different by an order of magnitude, the location of the pumping well that receives equal flux from two streams can be off the middle-line between the two streams by nearly 90%.  相似文献   

10.
Actual pumping tests may involve continuously decreasing rates over a certain period of time, and the hydraulic conductivity (K) and specific storage (Ss) of the tested confined aquifer cannot be interpreted from the classical constant‐rate test model. In this study, we revisit the aquifer drawdown characteristics of a pumping test with an exponentially decreasing rate using the dimensionless analytical solution for such a variable‐rate model. The drawdown may decrease with time for a short period of time at intermediate pumping times for such pumping tests. A larger ratio of initial to final pumping rate and a smaller radial distance of the observation well will enhance the decreasing feature. A larger decay constant results in an earlier decrease, but it weakens the extent of such a decrease. Based on the proposed dimensionless transformation, we have proposed two graphical methods for estimating K and Ss of the tested aquifer. The first is a new type curve method that does not employ the well function as commonly done in standard type curve analysis. Another is a new analytic method that takes advantage of the decreasing features of aquifer drawdown during the intermediate pumping stage. We have demonstrated the applicability and robustness of the two new graphical methods for aquifer characterization through a synthetic pumping test.  相似文献   

11.
The interaction between a gaining stream and a water-table aquifer is studied at an outwash plain. The aquifer is hydraulically well connected to the stream. Pumping tests were carried out in 1997 and 1998 in two wells 60 m from the stream, screening different depths of the aquifer. Drawdown was measured on both sides of the stream. Hydraulic head, drawdown, and stream depletion data were analyzed using numerical flow models. Similar models were fitted to each of two different data sets: Model A was fitted to steady-state hydraulic head and streamflow gain data not influenced by pumping; and model B was fitted to drawdown data measured during the 1998 pumping test. Each calibrated model closely fits its calibration data; however, predictions were biased if model A was used to predict the calibration data of model B, and vice versa. To further test the models, they were used to predict streamflow depletion during the two pumping tests as well as the drawdown during the 1997 test. Neither of these data were used for calibration. Model A predicted the measured depletions fairly accurately during both tests, whereas the predicted drawdowns in 1997 were significantly larger than actually measured. Contrary to this, the 1997 drawdowns predicted by model B were nearly unbiased; the predicted depletions deviate significantly from the measured depletions in 1997, but they compare well with the observations in 1998. Thus, although field work and analyses were extensive and done carefully to develop a ground water flow model that could predict both drawdown and streamflow depletion, the model predictions are biased. Analyses indicate that the deviations between model and data may be because of error in the models' representations of either the release of water from storage or of the hydrology in the riparian zone.  相似文献   

12.
Siting wells near streams requires an accurate estimate of the quantity of water derived from the river due to pumping. A number of hydrogeological and hydraulic parameters influence this value. This study estimates stream depletion under steady-state conditions for a variety of hydrogeological systems. A finite differences model was used to analyze several hydrogeological situations, and for each of these the stream depletion was estimated using an advective transport method. An empirical equation for stream depletion was obtained for the case of a stream that partially penetrates the aquifer and a pumping well that is screened over a portion of the aquifer. The derived equation, which is valid for both isotropic and anisotropic conditions, expresses stream depletion as a function of the unit inflow to the river, the discharge of the pumping well, the well screen length, the distance between the river and pumping well, the wetted perimeter, and a new parameter called "overlap," which is defined to be the distance between the riverbed and the top of well screen. The overlap parameter makes it possible to consider indirectly the vertical component of flow, which is accentuated when the well is screened below the streambed. The formula proposed here should be useful in deciding where to locate a pumping well and to decide the appropriate length of its screen.  相似文献   

13.
We have investigated non‐Darcian flow to a vertical fracture represented as an extended well using a linearization procedure and a finite difference method in this study. Approximate analytical solutions have been obtained with and without the consideration of fracture storage based on the linearization procedure. A numerical solution for such a non‐Darcian flow case has also been obtained with a finite difference method. We have compared the numerical solution with the approximate analytical solutions obtained by the linearization method and the Boltzmann transform. The results indicate that the linearized solution agrees generally well with the numerical solution at late times, and underestimates the dimensionless drawdown at early times, no matter if the fracture storage is considered or not. When the fracture storage is excluded, the Boltzmann transform solution overestimates the dimensionless drawdown during the entire pumping period. The dimensionless drawdowns in the fracture with fracture storage for different values of dimensionless non‐Darcian hydraulic conductivity β approach the same asymptotic value at early times. A larger β value results in a smaller dimensionless drawdown in both the fracture and the aquifer when the fracture storage is included. The dimensionless drawdown is approximately proportional to the square root of the dimensionless time at late times.  相似文献   

14.
In this study, we examine the maximum net extraction rate from the novel arrangement of an injection‐extraction well pair in a coastal aquifer, where fresh groundwater is reinjected through the injection well located between the interface toe and extraction well. Complex potential theory is employed to derive a new analytical solution for the maximum net extraction rate and corresponding stagnation‐point locations and recirculation ratio, assuming steady‐state, sharp‐interface conditions. The injection‐extraction well‐pair system outperforms a traditional single extraction well in terms of net extraction rate for a broad range of well placement and pumping rates, which is up to 50% higher for an aquifer with a thickness of 20 m, hydraulic conductivity of 10 m/d, and fresh water influx of 0.24 m2/d. Sensitivity analyses show that for a given fresh water discharge from an inland aquifer, a larger maximum net extraction is expected in cases with a smaller hydraulic conductivity or a smaller aquifer thickness, notwithstanding physical limits to drawdown at the pumping well that are not considered here. For an extraction well with a fixed location, the optimal net extraction rate linearly increases with the distance between the injection well and the sea, and the corresponding injection rate and recirculation ratio also increase. The analytical analysis in this study provides initial guidance for the design of well‐pair systems in coastal aquifers, and is therefore an extension beyond previous applications of analytical solutions of coastal pumping that apply only to extraction or injection wells.  相似文献   

15.
Detecting and quantifying small drawdown at observation wells distant from the pumping well greatly expands the characterized aquifer volume. However, this detection is often obscured by water level fluctuations such as barometric and tidal effects. A reliable analytical approach for distinguishing drawdown from nonpumping water‐level fluctuations is presented and tested here. Drawdown is distinguished by analytically simulating all pumping and nonpumping water‐level stresses simultaneously during the period of record. Pumping signals are generated with Theis models, where the pumping schedule is translated into water‐level change with the Theis solution. This approach closely matched drawdowns simulated with a complex three‐dimensional, hypothetical model and reasonably estimated drawdowns from an aquifer test conducted in a complex hydrogeologic system. Pumping‐induced changes generated with a numerical model and analytical Theis model agreed (RMS as low as 0.007 m) in cases where pumping signals traveled more than 1 km across confining units and fault structures. Maximum drawdowns of about 0.05 m were analytically estimated from field investigations where environmental fluctuations approached 0.2 m during the analysis period.  相似文献   

16.
An analytical model is presented for the analysis of constant flux tests conducted in a phreatic aquifer having a partially penetrating well with a finite thickness skin. The solution is derived in the Laplace transform domain for the drawdown in the pumping well, skin and formation regions. The time-domain solution in terms of the aquifer drawdown is then obtained from the numerical inversion of the Laplace transform and presented as dimensionless drawdown–time curves. The derived solution is used to investigate the effects of the hydraulic conductivity contrast between the skin and formation, in addition to wellbore storage, skin thickness, delayed yield, partial penetration and distance to the observation well. The results of the developed solution were compared with those from an existing solution for the case of an infinitesimally thin skin. The latter solution can never approximate that for the developed finite skin. Dimensionless drawdown–time curves were compared with the other published results for a confined aquifer. Positive skin effects are reflected in the early time and disappear in the intermediate and late time aquifer responses. But in the case of negative skin this is reversed and the negative skin also tends to disguise the wellbore storage effect. A thick negative skin lowers the overall drawdown in the aquifer and leads to more persistent delayed drainage. Partial penetration increases the drawdown in the case of a positive skin; however its effect is masked by the negative skin. The influence of a negative skin is pronounced over a broad range of radial distances. At distant observation points the influence of a positive skin is too small to be reflected in early and intermediate time pumping test data and consequently the type curve takes its asymptotic form.  相似文献   

17.
Abstract

An analytical solution is developed to delineate the capture zone of a pumping well in an aquifer with a regional flow perpendicular to a stream, assuming a leaky layer between the stream and the aquifer. Three different scenarios are considered for different pumping rates. At low pumping rates, the capture zone boundary will be completely contained in the aquifer. At medium pumping rates, the tip of the capture zone boundary will intrude into the leaky layer. Under these two scenarios, all the pumped water is supplied from the regional groundwater flow in the aquifer. At high pumping rates, however, the capture zone boundary intersects the stream and pumped water is supplied from both the aquifer and the stream. The two critical pumping rates which separate these three scenarios, as well as the proportion of pumped water from the stream and the aquifer, are determined for different hydraulic settings.

Editor D. Koutsoyiannis; Associate editor A. Koussis

Citation Asadi-Aghbolaghi, M., Rakhshandehroo, G.R., and Kompani-Zare, M., 2013. An analytical approach to capture zone delineation for a well near a stream with a leaky layer. Hydrological Sciences Journal, 58 (8), 1813–1823.  相似文献   

18.
The Laplace domain solutions have been obtained for three-dimensional groundwater flow to a well in confined and unconfined wedge-shaped aquifers. The solutions take into account partial penetration effects, instantaneous drainage or delayed yield, vertical anisotropy and the water table boundary condition. As a basis, the Laplace domain solutions for drawdown created by a point source in uniform, anisotropic confined and unconfined wedge-shaped aquifers are first derived. Then, by the principle of superposition the point source solutions are extended to the cases of partially and fully penetrating wells. Unlike the previous solution for the confined aquifer that contains improper integrals arising from the Hankel transform [Yeh HD, Chang YC. New analytical solutions for groundwater flow in wedge-shaped aquifers with various topographic boundary conditions. Adv Water Resour 2006;26:471–80], numerical evaluation of our solution is relatively easy using well known numerical Laplace inversion methods. The effects of wedge angle, pumping well location and observation point location on drawdown and the effects of partial penetration, screen location and delay index on the wedge boundary hydraulic gradient in unconfined aquifers have also been investigated. The results are presented in the form of dimensionless drawdown-time and boundary gradient-time type curves. The curves are useful for parameter identification, calculation of stream depletion rates and the assessment of water budgets in river basins.  相似文献   

19.
Aquifer Properties Determined from Two Analytical Solutions   总被引:3,自引:0,他引:3  
In the analysis of pumping test data, the quality of the determined aquifer parameters can be greatly improved by using a proper model of the aquifer system. Moench (1995) provided an analytical solution for flow to a well partially penetrating an unconfined aquifer. His solution, in contrast to the Neuman solution (1974), accounts for the noninstantaneous decline of the water table (delayed yield). Consequently, the calculated drawdown in these two solutions is different under certain circumstances, and this difference may therefore affect the computation of aquifer properties from pumping test data. This paper uses an inverse computational method to calculate four aquifer parameters as well as a delayed yield parameter, α1 from pumping test data using both the Neuman (1974) and Moench (1995) solutions. Time-drawdown data sets from a pumping test in an unconfined alluvial aquifer near Grand Island, Nebraska, were analyzed. In single-well analyses, horizontal hydraulic conductivity values derived from the Moench solution are lower, but vertical hydraulic conductivity values are higher than those calculated from the Neuman solution. However, the hydraulic conductivity values in composite-well analyses from both solutions become very close. Furthermore, the Neuman solution produces similar hydraulic conductivity values in the single-well and composite-well analyses, but the Moench solution does not. While variable α1, seems to play a role in affecting the computation of aquifer parameters in the single-well analysis, a much smaller effect was observed in the composite-well analysis. In general, specific yield determined using the Moench solution could be slightly higher than the values from the Neuman solution; however, they are still lower than the realistic values for sand and gravel aquifers.  相似文献   

20.
We analyze the optimal design of a pumping test for estimating hydrogeologic parameters that are subsequently used to predict stream depletion caused by groundwater pumping in a leaky aquifer. A global optimization method is used to identify the test’s optimal duration and the number and locations of observation wells. The objective is to minimize predictive uncertainty (variance) of the estimated stream depletion, which depends on the sensitivities of depletion and drawdown to relevant hydrogeologic parameters. The sensitivities are computed analytically from the solutions of Zlotnik and Tartakovsky [Zlotnik, V.A., Tartakovsky, D.M., 2008. Stream depletion by groundwater pumping in leaky aquifers. ASCE Journal of Hydrologic Engineering 13, 43–50] and the results are presented in a dimensionless form, facilitating their use for planning of pumping test at a variety of sites with similar hydrogeological settings. We show that stream depletion is generally very sensitive to aquitard’s leakage coefficient and stream-bed’s conductance. The optimal number of observation wells is two, their optimal locations are one close to the stream and the other close to the pumping well. We also provide guidelines on the test’s optimal duration and demonstrate that under certain conditions estimation of aquitard’s leakage coefficient and stream-bed’s conductance requires unrealistic test duration and/or signal-to-noise ratio.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号