首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The objective of most ground water quality monitoring programs is to obtain samples that are "representative" or that retain the physical and chemical properties of the ground water in an aquifer. Many factors can influence whether or not a particular sample is representative, but perhaps the most critical factor is the method or type of sampling device used to retrieve the sample.
The sampling equipment available today ranges from simple to highly sophisticated, and includes bailers, syringe devices, suction-lift pumps, gas-drive devices, bladder (Middelburg-type) pumps, gear-drive and helical rotor electric submersible pumps and gas-driven piston pumps. New devices are continually being developed for use in small-diameter wells in order to meet the needs of professionals engaged in implementing elaborate ground water monitoring programs.
In selecting a sampling device for a monitoring program, the professional must consider a number of details. Among the considerations are: the outside diameter of the device, the overall impact of the device on ground water sample integrity (including the materials from which the sampling device and associated equipment are made and the method by which the device delivers the sample), the capability of the device to purge the well of stagnant water, the rate and the ability to control the rate at which the sample is delivered, the depth limitations of the device, the ease of operating, cleaning and maintaining the device, the portability of the device and required accessory equipment, the reliability and durability of the device, and the initial and operational cost of the device and accessory equipment. Based on these considerations, each of the devices available for sampling ground water from small-diameter wells has its own unique set of advantages and disadvantages that make it suitable for sampling under specific sets of conditions. No one sampling device is applicable to all sampling situations.  相似文献   

2.
Loss of volatile organics during sampling is a well-recognized source of bias in ground water monitoring; sampling protocols attempt to minimize such loss. Such bias could be enhanced for ground water highly charged with dissolved gases such as methane. Such ground water was the object of this study. A positive-displacement bladder pump, a momentum-lift pump and a suction-lift, peristaltic pump were employed in sampling both methane-charged ground water for volatile aromatic hydrocarbons and a CO2-charged reservoir water for volatile chlorinated hydrocarbons. In both cases, the suction-lift pump produced samples with a significant negative bias (9 to 33 percent) relative to the other methods. Little difference between samples produced by the other pump Systems was noted at the field site, but in sampling the reservoir, the bladder pump produced samples that were 13 to 19 percent lower in halocarbon concentration than were samples from the momentum-lift pump.
These negative biases are tentatively interpreted as losses due to volatilization during sampling. Slightly greater negative biases occur for compounds of higher volatility as estimated from their Henry's law constants. Additional studies appear to be warranted in order to adequately establish the scientific basis for recommending protocols for sampling ground water in which degassing could enhance the loss of volatile organics during sampling.  相似文献   

3.
A New Multilevel Ground Water Monitoring System Using Multichannel Tubing   总被引:5,自引:0,他引:5  
A new multilevel ground water monitoring system has been developed that uses custom-extruded flexible 1.6-inch (4.1 cm) outside-diameter (O.D.) multichannel HOPE tubing (referred to as Continuous Multichannel Tubing or CMT) to monitor as many as seven discrete zones within a single borehole in either unconsolidated sediments or bedrock. Prior to inserting the tubing in the borehole, ports are created that allow ground water to enter six outer pie-shaped channels (nominal diameter = 0.5 inch [1.3 cm]) and a central hexagonal center channel (nominal diameter = 0.4 inch [1 cm]) at different depths, facilitating the measurement of depth-discrete piezometric heads and the collection of depth-discrete ground water samples. Sand packs and annular seals between the various monitored zones can be installed using conventional tremie methods. Alternatively, bentonite packers and prepacked sand packs have been developed that are attached to the tubing at the ground surface, facilitating precise positioning of annular seals and sand packs. Inflatable rubber packers for permanent or temporary installations in bedrock aquifers are currently undergoing site trials. Hydraulic heads are measured with conventional water-level meters or electronic pressure transducers to generate vertical profiles of hydraulic head. Ground water samples are collected using peristaltic pumps, small-diameter bailers, inertial lift pumps, or small-diameter canister samplers. For monitoring hydrophobic organic compounds, the CMT tubing is susceptible to both positive and negative biases caused by sorption, desorption, and diffusion. These biases can be minimized by: (1) purging the channels prior to sampling, (2) collecting samples from separate 0.25-inch (0.64 cm) O.D. Teflon sampling tubing inserted to the bottom of each sampling channel, or (3) collecting the samples downhole using sampling devices positioned next to the intake ports. More than 1000 CMT multilevel wells have been installed in North America and Europe to depths up to 260 feet (79 m) below ground surface. These wells have been installed in boreholes created in unconsolidated sediments and bedrock using a wide range of drilling equipment, including sonic, air rotary, diamond-bit coring, hollow-stem auger, and direct push. This paper presents a discussion of three field trials of the system, demonstrating its versatility and illustrating the type of depth-discrete data that can be collected with the system.  相似文献   

4.
Observations of colloidal movement under natural conditions and during pumping were conducted at several field sites. Results indicate that several modifications to present sampling protocols may improve the representativeness and cost effectiveness of obtaining ground water samples for assessing the total mobile contaminant load. These modifications include the installation of dedicated sampling devices, limited purging of the well prior to sampling, sampling at a flow rate of 100 mL/min, and no filtering of samples. This sampling approach can result in significant cost savings while providing the best possible water samples.  相似文献   

5.
Efforts to sample representative, undisturbed distributions of uranium in ground water beneath the Fernald Environmemal Management Project (FEMP) prompted the application of a novel technique that is less invasive in the monitoring well. Recent studies (Kearl et al. 1992; Barcelona et al. 1994) indicate that representative samples can and should be collected without prior well volume exchange purging or borehole evacuation. Field experiments conducted at the FMMP demonstrate that under specific sampling conditions in a welldefined hydrogeologic system, representative ground water samples for a monitoring program can be obtained without removing the conventional three well volumes from the well. The assumption is made that indicator parameter equilibration may not be necessary to determine when to collect representative samples at the P'liMP. Preliminary results obtained from the field experiment suggest that this may be true. The technique employs low purge rates (< 1 L/min) with dedicated bladder pumps with inlets located in the screened interval of the well, while not disturbing the stagnant water column above the screened interval. If adopted, this technique, termed micro-purge low-flow sampling, will produce representative ground water samples, significantly reduce sampling costs, and minimize; waste water over the monitoring life cycle at the FEMP. This technique is well suited for sites that have been fully characterized and are undergoing long-term monitoring.  相似文献   

6.
Several detergent-washing/air-drying decontamination protocols were tested to determine their ability to remove residual contamination from two types of ground water sampling devices. We tested a relatively simply constructed device, a bailer, and a much more complex, and theoretically more difficult to decontaminate, bladder pump. The devices were decontaminated after sampling ground water that was contaminated with organics that varied in their hydrophobic nature and propensity to be sorbed by the materials in the devices. These studies showed that a hot-detergent wash, hot-water rinse, and hot-air drying protocol was effective.  相似文献   

7.
A practical pumping system for the recovery of free petroleum hydrocarbon product from shallow aquifers has been developed. The system is patterned after suction-lift well point dewatering systems used in the construction industry. Pumping equipment consists of double-diaphragm suction-lift pumps manifolded to up to four recovery wells. Recovery wells are constructed with screens below the water table and sealed wellheads to enable vacuum-assisted flow of fluids to the wells. Pumps utilized are pneumatically driven, can be pumped dry without damage, induce a vacuum on the wells when pumping dry, and provide delivery of pumped fluids to fluid separation and storage facilities. The system is effective in both low- and high-permeability formations due to the wide range in available pumping rates afforded by the pumps.  相似文献   

8.
Micropurge sampling of ground water wells has been suggested as a possible replacement to traditional purge and sample methods. To compare methods, duplicate ground water samples were collected at two field sites using iraditional and micropurge methods. Samples were analyzed for selected organic and inorganic constituents, and the results were compared statistically. Analysis of the data using the nonparametric sign test indicates that within a 95 percent confidence interval, there was no significant difference between the two methods for the site contaminants and the majority of analytes. These analytical results were supported by visual observations with the colloidal borescope, which demonstrated impacts on the flow system in the well when using traditional sampling methods. Under selected circumstances, the results suggest replacing traditional sampling with micropurging based on reliability, cost, and waste minimization.  相似文献   

9.
Ground water at the Norman Landfill Research Site is contaminated by a leachate plume emanating from a closed, unlined landfill formerly operated by the city of Norman, Oklahoma, Ground water contaminated by the leachate plume is known to be elevated in the concentration of many, organic and inorganic constituents. Specific conductance, alkalinity, chloride, dissolved organic carbon, boron, sodium, strontium, and deuterium in ground water are considered to be indicators of the leachate plume at this site.
Leaf samples of broad-leafed cottonwood, Populus deltoides , were collected from 57 sites around the closed landfill. Cottonwood, a phreatophyte or "well plant," functions as a & surrogate well and serves as a ground water quality sampler. The leaf samples were combusted to ash and analyzed by instrumental neutron activation for 35 elements and by prompt-gamma instrumental neutron activation, for boron. A monitoring well was located within a few meters of a sampled cottonwood tree at 15 of the 57 sites, and ground water samples were collected from these monitoring wells simultaneously with a leaf sample. The chemical analyses of the ground water and leaf samples from these 15 sites indicated that boron, bromine, sodium, and strontium concentrations in leaves were significantly correlated with leachate indicator constituents in ground water. A point-plot map of selected percentiles indicated high concentrations of boron, bromine, and sodium in leaf ash from sites downgradient of the most recent landfill and from older landfills nearby.
Data from leaf analysis greatly extended the known areal extent of the leachate plume previously determined from a network of monitoring wells and geophysical surveys. This phytosgeochemical study provided a cost-effective method for assessing the extent of a leachate plume from an old landfill. Such a method may be useful as a preliminary sampling tool to guide the design of hydrogeochemical and geophysical studies.  相似文献   

10.
Acquisition of Representative Ground Water Quality Samples for Metals   总被引:1,自引:0,他引:1  
R.S. Kerr Environmental Research Laboratory (RSKERL) personnel have evaluated sampling procedures for the collection of representative, accurate, and reproducible ground water quality samples for metals for the past four years. Intensive sampling research at three different field sites has shown that the method by which samples are collected has a greater impact on sample quality, accuracy, and reproducibility than whether the samples are filtered or not. In particular, sample collection practices that induce artificially high levels of turbidity have been shown to have the greatest negative impacts on sample quality. Results indicated the ineffectiveness of bailers for collection of representative metal samples. Inconsistent operator usage together with excessive purging generally resulted in excessive turbidity (>100 NTUs) and large differences in filtered and unfiltered metal samples. The use of low flow rate purging and sampling consistently produced filtered and unfiltered samples that showed no significant differences in concentrations. Turbidity levels were generally less than 5 NTUs, even in fine-textured glacial till. We recommend the use of low flow rates, during both purging and sampling, placement of the sampling intake at the desired sampling point, minimal disturbance of the stagnant water column above the screened interval, monitoring of water quality indicators during purging, minimization of atmospheric contact with samples, and collection of unfiltered samples for metal analyses to estimate total contaminant loading in the system. While additional time is spent due to use of low flow rates, this is compensated for by eliminating the need for filtration, decreased volume of contaminated purge water, and less resampling to address inconsistent data results.  相似文献   

11.
Positive-displacement piston pumps that minimize sample agitation have no apparent advantage over centrifugal submersible pumps when used to collect ground water samples for analysis of low concentrations of purge-able organic compounds. Analytical uncertainties inherent in laboratory environments appear to influence analytical results of low-concentration purgeable organic compound samples more than either pump type or sampling team. Centrifugal submersible pumps are at least equally efficient as positive-displacement piston pumps in the recovery of carbon tetrachloride, 1,1,1-trichloroethane, trichloroethylene, and chloroform after sampling and analytical influences are made constant.  相似文献   

12.
The reliability of ground water monitoring information can be assured by careful selection of sample handling and analytical procedures. Sampling mechanism selection has been studied far less than analytical methodologies (Scalf et al. 1981, Nacht 1983). This study has as its primary goal the identification of reliable sampling mechanisms for purgeable organic compounds and gas-sensitive chemical parameters in ground water. Carefully controlled sampling experiments were run to investigate the error contributed to chemical results due to sampling mechanism alone. Fourteen commercial sampling devices in five mechanistic categories were evaluated for their performance in sample collection for solution parameters, dissolved gases and purgeable organic compounds. Systematic errors related to sampling mechanism can reduce the accuracy of monitoring data by factors of two to three times that involved in analytical procedures.  相似文献   

13.
A suction side sample collector (SSSC) is a contrivance installed hydraulically ahead of the intake port of a pumping device. This paper describes construction and operational details of SSSCs fitted to a submersible pump with packer for use in a 6-inch cased borehole, an air lift pump with packer for use in a 1-inch or 2.5-inch cased borehole, a bladder pump for use in a casing of 2-inch or greater diameter, and a jet pump with packer for use in a 2-inch cased borehole.
Each form of SSSC has been thoroughly tested in ground water quality sampling for volatile organic chemicals. Comparative data for samples collected with the SSSCs and conventional sample collecting gear are presented. The SSSC is demonstrated to be superior to other methods of collecting volatile organic chemical samples owing to its freedom from contamination by the pump delivery line and to its mode of collecting the sample from a position in the well remote from disturbance by the pumping technique.
SSSCs are conveniently decontaminated, easily transported, and can be used to deliver samples to the laboratory while still at formation pressure. The air-lift pumps, described in this paper for use with SSSCs in 1- and 2.5-inch casings, have pumping capacities greater than obtained by other methods that can operate in these small casings. Discharge rates of up to 2 gpm are routinely achieved with the 1-inch model and higher rates are common With the 2.5-inch model. The use of packers with these pumps reduces the time needed to replace the water in the casing with fresh water from the formation.  相似文献   

14.
A New System for Ground Water Monitoring   总被引:4,自引:0,他引:4  
This paper describes a new system for ground water monitoring, "the BAT System," which includes the following functions: (a) sampling of ground water in most types of soils, (b) measurement of pore water pressure, and (c) in situ measurement of hydraulic conductivity. The system can also be used for tracer tests. The system utilizes a permanently installed filter tip attached to a steel or PVC pipe. Installation is normally performed by pushing the tip down to the desired depth. The filter tip can also be buried beneath a landfill. The primary feature of the new system is that the filter tip contains a self-sealing quick coupling unit, which makes it possible to temporarily connect the filter tip to adapters for various functions, e.g. water sampling and for measurement of pore pressure and hydraulic conductivity. The new technique makes sampling of both pressurized water and gas possible. Samples are obtained directly in hermetically sealed, pre-sterilized sample cylinders. Sampling of ground water and measurement of pore pressure can be repeated over a long period of time with undiminished accuracy. This technique is also well-adapted for taking water samples from different strata in a soil profile, in both the saturated and unsaturated zones. Actual installations range from 0.5 to 60m depth.  相似文献   

15.
Eighteen sites in South Carolina under investigation by the Superfund program were sampled to determine ambient ground water quality. Samples from 11 of 15 monitoring wells sampled with a bailer contained either caprolactam or Santowhite® (a registered trademark of the Monsanto Co.) or both organic compounds. A maximum of 540 μg/L of caprolactam and 780 μg/L of Santowhite was observed in the samples from the monitoring wells. None of the samples collected using dedicated submersible pumps at 28 other wells contained either compound.
Caprolactam is used in the manufacturing of nylon cord, and Santowhite is used as an antioxidant in latex gloves. Therefore, it was suspected that the nylon cord used to raise and lower the bailer and the latex gloves that were worn during sampling may have contributed the caprolactam and Santowhite to the sample.
An experiment using pH-adjusted distilled water and private well water revealed that the nylon cord and the latex gloves may contribute contaminants to ground water samples. Research is needed into the potential for caprolactam and Santowhite to interfere with laboratory analyses in addition to the potential for absorption of contaminants by nylon cord. Until additional information is available, alternative materials or sampling techniques should be considered to minimize the potential impact of nylon cord and latex gloves on the quality of bailed samples.  相似文献   

16.
Variations in concentrations of trichloroethylene and related compounds in ground water obtained from seven ground water samplers were used to compare the performance of three submersible pumps, a centrifugal pump, two peristaltic pumps, and a bailer. Two- and 4-inch diameter submersible pumps and a centrifugal pump produced samples whose trichloroethylene concentrations, on the average, did not differ significantly from each other. Ground water samples collected by using a peristaltic pump and silicone tubing had significantly lower trichloroethylene concentrations than samples from the submersible pumps. Concentrations of 1,2-dichloroethylene and trichloroethylene in ground water samples collected by using a bailer were indistinguishable from those in samples taken by a submersible pump when the concentrations were as much as 96 and 76 micrograms per liter, respectively, but were 15 and 12 percent lower when concentrations were as low as 29 and 23 micrograms per liter, respectively. Tests of different configurations of sampler placement in observation wells indicate that pump placement, rate of pumping, duration of pumping, and the uniformity of the vertical and lateral distribution of trichloroethylene in ground water near the well screen have a potentially significant influence on trichloroethylene concentrations in ground water samples and that these factors can have a greater effect than the type of sampler used.  相似文献   

17.
Reinjection of untreated ground water during hydrocarbon recovery operations provides for economical water handling and can accelerate the recovery of the free hydrocarbons. However, considering current regulatory trends, water containing dissolved hydrocarbon constituents would require treatment prior to reinjection into the aquifer. The disposal of coproduced ground water is dependent on several factors, including the volume of water, level of treatment required, and availability of disposal options. Disposal options include reinjection, discharge to surface water, and beneficial use. This paper presents treatment and disposal options for coproduced water during hydrocarbon recovery operations including cost comparisons for a particular case study.
Treatment technologies for oil/water separation, inorganics and heavy metals removal, and dissolved hydrocarbon removal are presented. The primary technologies discussed for dissolved hydrocarbon removal include air stripping, activated carbon adsorption, biological treatment, and combinations of these technologies. Consideration of the use of existing refinery waste water treatment facilities for ground water treatment should be encouraged where applicable. However, separate treatment facilities are usually required because the use of existing on-site treatment facilities is usually not feasible because of the volume of water produced during large recovery projects and the effectiveness of existing treatment facilities. A specific case example is presented with costs for applying different technologies including the use of existing on-site facilities. Treatment costs ranged between 44 cents to $2.82 per thousand gallons (11 cents to 75 cents per thousand liters) of water treated for the specific technologies examined herein.  相似文献   

18.
Large differences in chemistry between sampling points separated In short vertical intervals are often observed in contaminant plumes in both granular and fractured aquifers. However, most regional models assume that such differences will be reduced by dispersive mixing during transport. At a field site located in a discharge area on the Oak Ridge Reservation, Tennessee, ground water flows along discrete flowpaths, as evidenced by the presence of four distinct water types—Ca-HCO3, Ca-Na-HCO3, and Na-Ca-HCO3, and Na-Ca-HCO3-S04—in samples collected from shallow (< 3D in) multilevel wells. The preservation of distinct chemical signatures suggests that ground water must he contained in discrete flow zones during much of its transport time. The chemical composition of the water types can be explained primarily by strata-bound flow over varying flowpath lengths and secondarily by mixing of waters during cross-formational flow in a discharge zone. The hydrochemical facies identified by correlation of water types between the boreholes indicate the general orientation of ground water How paths. These inferred flowpaths are oblique to the orientation of the measured hydraulic gradient and are more closely aligned with bedding and the calculated flow direction. Results of this study indicate that discrete multilevel sampling for analysis of major ions, in addition to information gathered from tracer tests, borehole flow tests. and visual core observations, can provide valuable information on flow directions and preferential flowpaths for contaminant transport.  相似文献   

19.
Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage-treatment plant infiltration bed that overlies a well-studied u neon fined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S. Geological Survey (LJSGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.  相似文献   

20.
The authors have recently used several innovative sampling techniques for ground water monitoring at hazardous waste sites. Two of these techniques were used for the first time on the Biscayne Aquifer Super-fund Project in Miami, Florida. This is the largest sampling program conducted so far under the U.S. Environmental Protection Agency (EPA) Superfund Program.
One sampling technique involved the use of the new ISCO Model 2600 submersible portable well sampling pump. A compressed air source forces water from the well into the pump casing and then delivers it to the surface (through a pulsating action). This pump was used in wells that could not be sampled with surface lift devices.
Another sampling technique involved the use of a Teflon manifold sampling device. The manifold is inserted into the top of the sampling bottle and a peristaltic pump creates a vacuum to draw the water sample from the well into the bottle. The major advantage of using this sampling technique for ground water monitoring at hazardous waste sites is the direct delivery of the water sample into the collection container. In this manner, the potential for contamination is reduced because, prior to delivery to the sample container, the sample contacts only the Teflon, which is well-known for its inert properties.
Quality assurance results from the Superfund project indicate that these sampling techniques are successful in reducing cross-contamination between monitoring wells. Analysis of field blanks using organic-free water in contact with these sampling devices did not show any concentration at or above the method detection limit for each priority pollutant.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号