1.
In quasi‐static tests for structures with multi‐DOF, the forces exerted to the structures commonly follow a prescribed force profile, for example, triangular pattern and/or uniform pattern. Therefore, force control is the natural choice. However, force control is no longer applicable when the specimens sustain significant stiffness and strength degradation, particularly in collapse tests. To solve this problem, a force–displacement mixed control algorithm is proposed, which is able to achieve stable control in quasi‐static tests following prescribed force profiles. On the basis of the FlexTest IIm platform of the MTS Systems Corporation (14000 Technology Dr, Eden Prairie, MN 55344 United States), a test program named Tsinghua University mixed control test program, which uses a mixed control algorithm, was developed. The algorithm was initially applied to an elastic test of a cantilever column to verify its accuracy and stability and then to a collapse test of a multistory RC frame to investigate its effectiveness. In the collapse test, the effects of major control parameters, that is, the number of iterative rounds and the loading time of each round on the control accuracy, were also studied. The test results show that the test program applying the mixed control algorithm can achieve stable control of the collapse tests maintaining the expected force profile. Increasing the number of iterative rounds and the loading time of each round can improve the control accuracy. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
The effectiveness of equivalent force control (EFC) method has been experimentally validated through hybrid tests with simple specimens. In this paper, the EFC method is applied for the MDOF pseudo‐dynamic substructure tests in which a three‐storey frame‐supported reinforced concrete masonry shear wall with full scale is chosen as physical substructure. The effects of equivalent force controller parameters on the response performance are studied. Analytical expressions for the controller parameter ranges are derived to avoid response overshooting or oscillation and are verified by numerical simulation. The controller parameters are determined based on analytical and numerical studies and used in the actual full‐scale pseudo‐dynamic test. The test results show good tracking performance of EFC, which indicates a successful test. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
This paper presents a substructure online hybrid test system that is extensible for geographically distributed tests.This system consists of a set of devices conventionally used for cyclic tests to load the tested substructures onto the target displacement or the target force.Due to their robustness and portability,individual sets of conventional loading devices can be transported and reconfigured to realize physical loading in geographically remote laboratories.Another appealing feature is the flexible displacement-force mixed control that is particularly suitable for specimens having large disparities in stiffness during various performance stages.To conduct a substructure online hybrid test,an extensible framework is developed,which is equipped with a generalized interface to encapsulate each substructure.Multiple tested substructures and analyzed substructures using various structural program codes can be accommodated within the single framework,simply interfaced with the boundary displacements and forces.A coordinator program is developed to keep the boundaries among all substructures compatible and equilibrated.An Internet-based data exchange scheme is also devised to transfer data among computers equipped with different software environments.A series of online hybrid tests are introduced,and the portability,flexibility,and extensibility of the online hybrid test system are demonstrated.  相似文献   

4.
Online hybrid tests (called the online tests), particularly when combined with substructuring techniques, are able to conduct large‐scale tests. An extension of this technique is to combine multiple loading tests conducted in remote locations and to integrate the tests with large numerical analysis codes. In this study, a new Internet online test system is developed in which a physical test is conducted in one place, the associated numerical analysis is performed in a remote location, and the two locations communicate over the Internet. To implement the system, a technique that links test and analysis domains located at different places is proposed, and an Internet data exchange interface is devised to allow data communication across Internet. A practical method that utilizes standard protocols implemented by operating systems for sharing files and folders is adopted to ensure stable and robust communication between remotely located servers that commonly protect themselves by strict firewalls. To combine the online test with a finite element program formulated in an incremental form and adopting an implicit integration scheme, a tangent stiffness prediction procedure is proposed. In this procedure, a tangent stiffness is estimated based on a few previous steps of experimental data. Using the system devised, tests on a base‐isolated structure were carried out. Here, the base‐isolation layer was taken as the tested part and tested in Kyoto University, Japan, and the superstructure was modelled by means of a finite element program and analysed in a computer located in Osaka University. A series of physical Internet online tests were carried out, with the integration time interval and the method of tangent stiffness prediction as the major parameters. The tests demonstrated that the Internet communication was very stable and robust, without malfunctions. The proposed method of stiffness prediction was effective even when the experimental hysteresis curves exhibited complex behaviour, thereby ensuring accurate simulation for the earthquake response of the entire structure. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
A new Internet online hybrid test system, designated the ‘peer‐to‐peer (P2P) Internet online hybrid test system’, is proposed. In the system, the simulated structure is divided into multiple substructures, and each substructure is analysed numerically or tested physically in parallel at geographically distributed locations. The equations of motion are not formulated for the entire structure but for each substructure separately. Substructures are treated as highly independent systems, and only standard I/O, i.e. displacements and forces at the boundaries, are used as interfaces. A ‘Coordinator’ equipped with an iterative algorithm based on quasi‐Newton iterations is developed to achieve compatibility and equilibrium at boundaries. A test procedure, featuring two rounds of quasi‐Newton iterations and using assumed elastic stiffness, is adopted to avoid iteration for the substructure being tested physically. A fast and stable solution using a socket mechanism is developed for data exchange over the Internet. Demonstration tests applied to a base‐isolated structure was conducted, and the results are compared with an online hybrid test using the conventional test method. The results obtained from the P2P Internet hybrid test match very closely those obtained from the conventional tests. Investigations are also carried out on time consumption and control accuracy. The results show that the Internet data exchange solution using the socket mechanism is fast, and tests were completed successfully under the constructed Internet online hybrid test environment. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

6.
A pseudodynamic testing procedure has been applied by which the seismic response of a base‐isolated building is obtained by using as specimen the isolators, while the superstructure is numerically simulated. The procedure also takes advantage of the continuous pseudodynamic testing capabilities of the ELSA laboratory, which increase the accuracy of the results and reduce the strain‐rate effect of the rubber bearings. A simple proportional correction of the measured forces compensates the remaining strain‐rate effect due to the unrealistic speed of the test. The correction factor is obtained by means of a characterizing test on the specific rubber isolators. The developed method has been successfully applied to the prediction of the seismic response of a base‐isolated four‐storey building submitted to several specified accelerograms. The results for those earthquakes as well as the effects of some changes of the parameters of the system are discussed. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

7.
Vibration mitigation using smart, reliable and cost‐effective mechanisms that requires small activation power is the primary objective of this paper. A semi‐active controller‐based neural network for base‐isolation structure equipped with a magnetorheological (MR) damper is presented and evaluated. An inverse neural network model (INV‐MR) is constructed to replicate the inverse dynamics of the MR damper. Next, linear quadratic Gaussian (LQG) controller is designed to produce the optimal control force. Thereafter, the LQG controller and the INV‐MR models are linked to control the structure. The coupled LQG and INV‐MR system was used to train a semi‐active neuro‐controller, designated as SA‐NC, which produces the necessary control voltage that actuates the MR damper. To evaluate the proposed method, the SA‐NC is compared to passive lead–rubber bearing isolation systems (LRBs). Results revealed that the SA‐NC was quite effective in seismic response reduction for wide range of motions from moderate to severe seismic events compared to the passive systems. In addition, the semi‐active MR damper enjoys many desirable features, such as its inherent stability, practicality and small power requirements. The effectiveness of the SA‐NC is illustrated and verified using simulated response of a six‐degree‐of‐freedom model of a base‐isolated building excited by several historical earthquake records. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

8.
The seismic response of a critical rotating machine either rigidly attached to a floor or independently isolated housed within an initially aseismically designed or uncontrolled structure are investigated. A particular isolation system, the Resilient‐Friction Base Isolator (RFBI), is employed. Finite element formulations of a rotor‐disk‐bearing model on a rigid base are developed. The equations of motion for the combined rotating machine–structure–RFBI systems are presented. Parametric studies are performed to investigate the effects of variations in system physical properties including friction coefficient, mass ratio, shaft flexibility, bearing rigidity, bearing damping and speed of rotation on the response of rotating machines for the combined rotating machine–structure–isolator systems. Comparative studies in the peak response of the rotating machine supported on various isolation systems and the corresponding fixed base system are carried out. The study indicates that the Resilient‐Friction Base Isolator can significantly reduce the seismic response of rotating components to potentially damaging ground excitations. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

9.
A new on‐line hybrid test system incorporated with the substructuring technique is developed. In this system, a general‐purpose finite element software is employed to obtain the restoring forces of the numerical substructure accurately. The restart option is repeatedly used to accommodate the software with alternating loading and analysis characteristic of the on‐line test but without touching the source code. An eight‐storey base‐isolated structure is tested to evaluate the feasibility and effectiveness of the proposed test system. The overall structure is divided into two substructures, i.e. a superstructure to be analysed by the software and a base‐isolation layer to be tested physically. Collisions between the base‐isolation layer and the surrounding walls are considered in the test. The responses of the overall structure are reasonable, and smooth operation is achieved without any malfunction. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

10.
This paper presents a new method, called the equivalent force control method, for solving the nonlinear equations of motion in a real‐time substructure test using an implicit time integration algorithm. The method replaces the numerical iteration in implicit integration with a force‐feedback control loop, while displacement control is retained to control the motion of an actuator. The method is formulated in such a way that it represents a unified approach that also encompasses the effective force test method. The accuracy and effectiveness of the method have been demonstrated with numerical simulations of real‐time substructure tests with physical substructures represented by spring and damper elements, respectively. The method has also been validated with actual tests in which a Magnetorheological damper was used as the physical substructure. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

11.
A series of full‐scale shaking table tests are conducted using the E‐Defense shaking table facility on a base‐isolated four‐story RC hospital structure. A variety of furniture items, medical appliances, and service utilities are placed on the hospital specimen in as realistic a manner as possible. Four ground motions are adopted, including recorded near‐fault ground motions and synthesized long‐period, long‐duration ground motions. The test results show that the base‐isolated system performed very effectively against near‐fault ground motions due to significant reduction in the floor acceleration response, and operability and functionality of the hospital service is improved significantly as compared with the case observed for the corresponding base‐fixed system. Against the long‐period ground motion, however, the hospital service is difficult to maintain, primarily because of the significant motion of furniture items and medical appliances supported by casters. Resonance accentuated large displacements and velocities on the floors of the base‐isolated system, which causes such furniture items and medical appliances to slide, sometimes more than 3 m, resulting in occasional collision with other furnitures or against the surrounding partition walls. It is notable that a key to maintaining the function of the medical facilities is to securely lock the casters of furniture and medical appliances. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
The mid‐story isolation design method is recently gaining popularity for the seismic protective design of buildings located in the areas of high population. In a mid‐story isolated building, the isolation system is incorporated into the mid‐story rather than the base of the building. In this paper, the dynamic characteristics and seismic responses of mid‐story isolated buildings are investigated using a simplified three‐lumped‐mass structural model for which equivalent linear properties are formulated. From the parametric study, it is found that the nominal frequencies of the superstructure and the substructure, respectively, above and below the isolation system have significant influences on the isolation frequency and equivalent damping ratio of a mid‐story isolated building. Moreover, the mass and stiffness of the substructure are of greater significance than the superstructure in affecting the dynamic characteristics of the isolated building. Besides, based on the response spectrum analysis, it is noted that the higher mode responses may contribute significantly to the story shear force of the substructure. Consequently, the equivalent lateral force procedure of design codes should carefully include the effects of higher modes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
Base isolation is a well known technology that has been proven to reduce structural response to horizontal ground accelerations. However, vertical response still remains a topic of concern for base‐isolated buildings, perhaps more so than in fixed‐base buildings as isolation is often used when high performance is required. To investigate the effects of vertical response on building contents and nonstructural components, a series of full‐scale shaking table tests were conducted at the E‐Defense facility in Japan. A four‐story base‐isolated reinforced concrete building was outfitted as a medical facility with a wide variety of contents, and the behavior of the contents was observed. The rubber base isolation system was found to significantly amplify vertical accelerations in some cases. However, the damage caused by the vertical ground motions was not detrimental when peak vertical floor accelerations remained below 2 g with three exceptions: (1) small items placed on shelves slid or toppled; (2) objects jumped when placed on nonrigid furniture, which tended to increase the response; and (3) equipment with vertical eccentricities rocked and jumped. In these tests, all equipment and nonstructural components remained functional after shaking. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
A simple non‐linear control law is proposed for reducing structural responses against seismic excitations. This law defines control force dynamics by one differential equation involving a non‐linear term that restrains the control force amplitude. If non‐linearity is neglected, the control force becomes the force in a Maxwell element, so it is called the non‐linear‐Maxwell‐element‐type (NMW) control force. The NMW control force vs. deformation relation plots hysteretic curves. The basic performance of an SDOF model with the NMW control force is examined for various conditions by numerical analyses. Furthermore, the control law is extended to fit an MDOF structural model, and an application example is shown. The computational results show that the NMW control force efficiently reduces structural responses. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

15.
This paper investigates the application of the sliding mode control (SMC) strategies for reducing the dynamic responses of the building structures with base‐isolation hybrid protective system. It focuses on the use of reaching law method, a most attractive controller design approach of the SMC theory, for the development of control algorithms. By using the constant plus proportional rate reaching law and the power rate reaching law, two kinds of hybrid control methods are presented. The compound equation of motion of the base‐isolation hybrid building structures, which is suitable for numerical analysis, has been constructed. The simulation results are obtained for an eight‐storey shear building equipped with base‐isolation hybrid protective system under seismic excitations. It is observed that both the constant plus proportional rate reaching law and the power rate reaching law hybrid control method presented in this paper are quite effective. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

16.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

17.
Servo‐hydraulic actuators have been widely used for experimental studies in engineering. They can be controlled in either displacement or force control mode depending on the purpose of a test. It is necessary to control the actuators in real time when the rate‐dependency effect of a test specimen needs to be accounted for under dynamic loads. Real‐time hybrid simulation (RTHS) and effective force testing (EFT) method, which can consider the rate‐dependency effect, have been known as viable alternatives to the shake table testing method. Due to the lack of knowledge in real‐time force control, however, the structures that can be tested with RTHS and EFT are fairly limited. For instance, satisfying the force boundary condition for axially stiff members is a challenging task in RTHS, while EFT has a difficulty to be implemented for nonlinear structures. In order to resolve these issues, this paper introduces new real‐time force control methods utilizing the adaptive time series (ATS) compensator and compliance springs. Unlike existing methods, the proposed force control methods do not require the structural modeling of a test structure, making it easy to be implemented especially for nonlinear structures. The force tracking performance of the proposed methods is evaluated for a small‐scale steel mass block system with a magneto‐rheological damper subjected to various target forces. Accuracy, time delay, and resonance response of these methods are discussed along with their force control performance for an axially stiff member. Overall, a satisfactory force tracking performance was observed by using the proposed force control methods.  相似文献   

18.
The storage capacity of a temperate mixed oak–beech stand was investigated as a function of stand density and species composition. Measurements were performed in selected zones delimited by three neighbouring trees. Three independent approaches were compared: (i) a spraying laboratory experiment to estimate the water storage on foliage before and after dripping; (ii) a mechanistic model describing rainfall partitioning within the forest canopy and providing estimates of foliage storage capacities; and (iii) linear regression analyses to evaluate the canopy (foliage + branches) storage capacity using the relationship between throughfall and rainfall. Good agreement was generally observed between the laboratory experiment and the mechanistic model estimates, while estimations from the regression method tended to exceed those from the other approaches. Storage capacity estimates ranged from 0·22 mm to 0·80 mm for pure oak zones, from 0·24 mm to 1·12 mm for mixed zones and from 0·53 mm to 1·17 mm for pure beech zones. The increase of storage capacity with increasing proportion of beech in the canopy resulted from higher beech LAI compared with oak. Similarly, for mixed and pure beech canopies, storage capacity was higher for high density zones than for low density zones as a result of the increase in LAI with increasing local basal area; in contrast, for pure oak, the storage capacity was not related to basal area because of the lower shade‐tolerance of this species compared with beech. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
Recent studies have indicated uncertainty about the performance limit states of seismically isolated buildings in very large earthquakes, especially if the isolator displacement demands exceed the seismic gap and induce pounding. Previous research has shown the benefit of providing phased supplemental damping that does not affect the isolation system response in a design event. A phased passive control device, or gap damper, was designed, fabricated, and experimentally evaluated during shake table testing of a quarter scale base‐isolated three‐story steel frame building. Identical input motions were applied to system configurations without a gap damper and with a gap damper, to directly assess the influence of the gap damper on displacement and acceleration demands. The gap damper was observed to reduce displacement demands by up to 15% relative to the isolated system without the gap damper. Superstructure floor accelerations increased substantially because of damper activation, but were limited to a peak of about 1.18 g. The gap damper reduces displacement most effectively if the ground motion contains one or more of the following characteristics: the spectral displacement increases with increasing period near the effective period of the isolation system, the motion is dominated by a single large pulse rather than multiple cycles at a consistent intensity, and the motion has a dominant component aligned with a major axis of the structure. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

20.
A damage detection algorithm of structural health monitoring systems for base‐isolated buildings is proposed. The algorithm consists of the multiple‐input multiple‐output subspace identification method and the complex modal analysis. The algorithm is applicable to linear and non‐linear systems. The story stiffness and damping as damage indices of a shear structure are identified by the algorithm. The algorithm is further tuned for base‐isolated buildings considering their unique dynamic characteristics by simplifying the systems to single‐degree‐of‐freedom systems. The isolation layer and the superstructure of a base‐isolated building are treated as separate substructures as they are distinctly different in their dynamic properties. The effectiveness of the algorithm is evaluated through the numerical analysis and experiment. Finally, the algorithm is applied to the existing 7‐story base‐isolated building that is equipped with an Internet‐based monitoring system. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   