首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Isotope dilution (ID) mass spectrometry is a primary method of analysis suited for the accurate and precise measurement of several trace elements in geological matrices. Here we present mass fractions and respective uncertainties for Cr, Cu, Ni, Sn, Sr and Zn in 10 silicate rock reference materials (BCR‐2, BRP‐1, BIR‐1, OU‐6, GSP‐2, GSR‐1, AGV‐1, RGM‐1, RGM‐2 and G‐3) obtained by the double ID technique and measuring the isotope ratios with an inductively coupled plasma‐mass spectrometer equipped with collision cell. Test portions of the samples were dissolved by validated procedures, and no further matrix separation was applied. Addition of spikes was designed to achieve isotope ratios close to unity to minimise error magnification factors, according to the ID theory. Radiogenic ingrowth of 87Sr from the decay of 87Rb was considered in the calculation of Sr mass fractions. The mean values of our results mostly agree with reference values, considering both uncertainties at the 95% confidence level, and also with ID data published for AGV‐1. Considering all results, the means of the combined uncertainties were < 1% for Sr, approximately 2% for Sn and Cu, 4% for Cr and Ni and almost 6% for Zn.  相似文献   

2.
A procedure for the determination of chlorine by the isotope dilution technique (ID) using negative thermal ionisation mass spectrometry (N-TIMS) is described. Silicate samples of about 10 mg were spiked and decomposed with hydrofluoric acid, and chlorine was isolated by precipitation of silver chloride after neutralisation with Ca(OH)2. The ammonical solution of AgCl was then subjected to N-TIMS. Replicate analyses of rock reference materials, typically of JB-1 and JR-1, demonstrated the high quality of the analyses (precision for Cl was ± 1-2%). We present here the most precise data sets of chlorine concentrations in nine igneous rock reference materials, three basalts (JB-1, JB-2, JB-3), two andesites (JA-3, AGV-1), two rhyolites (JR-1, JR-2) and two granodiorites (JG-3, GSP-1). The chlorine concentrations found ranged from 152 μg g-1 in AGV-1 to 1008 μg g-1 in JR-1. Our results presented here are partly (but not completely) in agreement with recommended values, where they are available. The N-TIMS ID technique can thus be used as a means of determining low chlorine contents in silicate materials to high precision.  相似文献   

3.
查向平  龚冰  郑永飞 《岩矿测试》2014,33(4):453-467
同位素比值质谱分析方法是准确测量各种同位素相对丰度的标准方法。连续流同位素质谱的出现不仅提高运行效率,也降低了样品用量并提高灵敏度。但是,要使这种方法获得更好准确度和精度的同位素数据,并做到所获得数据可与其他实验室结果进行类比,从而得到可靠的同位素数据,这就需要好的分析策略和运行方案,还需要对仪器日常性能和数据质量进行严密的监视管控,而且还取决于原始数据如何进一步标准化到国际同位素尺度上。因此,同位素比值质谱结合元素分析仪(或热转换元素分析仪)连续流方法要实现可靠的稳定同位素分析需要:①设备安装和环境控制、测试准备、样品制备和称量、标准物质选择及序列等规范化质量控制措施;②严格校准仪器系统(包括调节灵敏度和线性,背景值监测,稳定性检测,H+3系数校正等);③可靠的数据处理。目前不同的实验室,采用标准物质来标定系统、对测量的同位素数据进行标准化,以及利用控制曲线来监测系统稳定性并对不确定度的计算,这些策略往往都不同。因此,统一的数据处理方案是被高度期待的。目前最好的执行方案是基于线性回归的两点或多点标准化方法。如果每一批样品中测量两个不同的标准物质四次,或者测量四个标准物质两次,那么不确定度会降低50%。当前同位素比值质谱能够测定同位素比值的不确定度一般要好于0.02‰。但是,标准物质的使用既要考虑样品的性质,同时要涵盖它们未知同位素组成的范围,尤其氢同位素在现阶段缺乏标准物质和测量的仪器精度较差(比碳、氮、氧等要低一个数量级)的情况下,这显然是稳定同位素分析者的一个重大挑战。本文概括了同位素比值质谱结合元素分析仪(或热转换元素分析仪)的基本操作原理和分析实践,将数据处理运用到同位素比值分析之中,获得连续流同位素比值质谱分析结果的合理准确度和精度。  相似文献   

4.
Oxygen isotopes are a versatile tool to address a wide range of questions in the Earth sciences. Applications include geothermometry, paleoclimatology, tracing of geochemical reservoirs, fluid-rock interaction, magmatic petrogenesis, and identification of extra-terrestrial materials. Zircon arguably provides one of the most robust records of primary magmatic O isotope ratio due to low diffusion rates in crystalline grains. The ability to correlate zircon O isotopes with temporal and petrogenetic information (e.g. U-Pb geochronology, Lu-Hf isotopes, and trace elements) makes this mineral a key archive for understanding Earth’s crustal evolution. Consequently, zircon O isotope geochemistry has found widespread usage to address fundamental questions across the earth and planetary sciences. The general apparent ease of O isotopic acquisition through the advancement of rapid in situ techniques (i.e. secondary ion mass spectrometry; SIMS) and associated dedicated national laboratories has led to the generation of large O isotopic data sets of variable quality, highlighting the importance of a coherent workflow for data collection, reduction, and presentation. This paper presents a set of approaches for measurement, assessment, and reporting of zircon O isotope data. The focus in this contribution is on in situ analysis via secondary ion mass spectrometry using large geometry instruments, but other commonly used techniques are briefly reviewed for context. This work aims to provide an analytical framework necessary for geologically meaningful interpretation of O isotope data. In addition, we describe inherent geological (e.g. radiation-induced disturbance of the zircon O isotopic system) and analytical (e.g. fractionation due to sample topography effects) challenges and outline means to identify and avoid such issues as a prerequisite to the generation of robust primary O isotopic signatures for geological interpretation.  相似文献   

5.
Ever‐increasing precision in isotope ratio measurements requires a concomitant small bias within and between laboratories. The double spike technique is the most suitable method to obtain reliable isotope composition data that are accurately corrected for instrumental mass fractionation. Compared with other methods, such as sample‐calibrator bracketing (SCB), only the double spike technique can correct for all sources of fractionation after equilibration of the sample with the double spike, such as that incurred during chemical separation and measurement. In addition, it is not dependent on a priori assumptions of perfect matrix matching of samples to reference materials or quantitative recovery of the sample through the chemical separation procedure to yield accurate results. In this review article, we present a detailed discussion of the merits of the double spike technique, how to design and calibrate a suitable double spike and analytical strategies. Our objective is to offer a step‐by‐step introduction to the use of the double spike technique in order to lower potential barriers that researchers new to the subject might face, such that double spiking will replace SCB as the measurement method of choice.  相似文献   

6.
Large volumes of coal fly ash are continually being produced and stockpiled around the world and can be a source of environmentally sensitive trace elements. Whilst leaching tests are used for regulatory purposes, these provide little information about the true geochemical behaviour and ‘reactivity’ of trace elements in coal ash because they are poorly selective. Isotope dilution (ID) assays are frequently used in soil geochemistry as a means of measuring the reactive pools of trace metals that are in equilibrium with soil pore waters. This paper examines the applicability of multi-element ID assays in measuring the labile or reactive pool of Cd, Pb and Zn in a range of fresh and weathered fly ash, where pH is generally much more alkaline than in soils. The method generally worked well using 0.0005 M EDTA as a background electrolyte as it provided robust analytical ICP-MS measurements as well as fulfilling the important principle of ID that non-labile metal should not be solubilised. Reactive pools were equivalent to 0.5–3% of the total Pb pool and 4–13% of the total Cd pool. For Zn, where samples had pH < 11.5, the reactive Zn pool varied between 0.3% and 2%; when fresh ash samples with pH > 11.5 were tested, the method failed as the spiked isotope appeared to be sorbed or precipitated. Ash weathering was found to exert little impact on the lability of Cd, Pb and Zn. Isotope dilution results were compared with 0.43 M HNO3 and 0.05 M EDTA extractions, these commonly being used as analogues of the ID assay, and concluded that these can be used as fast, cost-effective and simple proxies for the ID assays. Results suggest that ID methods can be used to enhance knowledge of trace element behaviour in fresh and weathered fly ash.  相似文献   

7.
The double‐spike approach for correction of instrumental mass bias in mass spectrometry data is well established. However, there is very little consistency within the scientific community in terms of double‐spike data reduction. Double‐spike solutions require computer calculation, using either geometric or algebraic approaches, and are often performed using spreadsheet calculations that vary from group to group and between isotope systems. Here, we present IsoSpike, a generalised computer procedure for the processing of double‐spike mass spectrometry data, built as an add‐on for the Iolite data‐reduction package ( www.iolite.org.au ). Use of this software permits visualisation of mass spectrometry data in a time window, and rigorous treatment and screening of data. Additionally, IsoSpike uses an integration‐by‐integration approach where the double‐spike calculations are performed on every integration within an analysis, providing straightforward quantification of uncertainties on double‐spike‐corrected isotope ratios. The advantages of this approach over traditional methods are discussed here. Platinum stable isotope data are presented as an example data set, although the procedure is applicable to any double‐spike system. IsoSpike is freely available from www.isospike.org .  相似文献   

8.
We present a double-spike isotope dilution MC-ICP-MS technique for the determination of germanium (Ge) isotope fractionation. Using this technique we determined Ge isotope compositions of geothermal spring fluids, a Columbia River Basalt sample, and an in-house diatom standard. Our technique uses a 73Ge/70Ge double spike in combination with hydride generation for Ge extraction from the sample matrix. Fractionation is determined on the 74Ge/72Ge mass ratio. The double spike allows us to effectively correct analytical isotope fractionation. Our external standard reproducibility is 0.4‰ (2 SD) over the course of several months. The minimum quantity of Ge needed for isotope analysis is approximately 2 ng. Consistent with previous work on geothermal fluids, Ge in the geothermal spring samples presented here is enriched over Si as compared to low temperature weathering signatures. This observation is typically interpreted as Ge exclusion during silicate mineral precipitation (e.g., quartz). Our isotope results indicate that the analyzed high temperature fluids fractionate Ge isotopes with a range in δ74Ge between −0.4‰ and −1.4‰ relative to a Columbia River basalt. We cautiously interpret the observed fractionation as preferential removal of heavy Ge isotopes out of solution during cooling of the hydrothermal fluid and subsequent precipitation of quartz.  相似文献   

9.
李延河 《地球学报》2020,41(5):583-589
同位素定年和示踪技术已渗透到地球科学的各个方面, 成为确定地质事件时代和成岩成矿年龄、示踪成岩成矿物质来源和形成环境条件的重要手段, 推动地球科学发展的重要动力。随着分析技术的不断发展, 微区/微量同位素、非传统同位素、高维度同位素已成为当前国际同位素地球化学研究的前沿和重点领域, 近年来我国在该领域也取得长足发展和一系列重大成果。本“同位素分析新技术与地质应用研究新进展”专辑集中刊发了13篇这方面的文章, 主要涵盖了两个方向的研究成果: (1)同位素地质分析新方法及标准物质研制; (2)同位素地球化学研究新进展, 主要包括同位素示踪技术在矿床和海洋沉积环境中应用研究。本文将对收录本专辑论文的研究工作做一简要介绍, 对深入了解我国同位素地质分析技术及应用研究最新进展具有一定参考价值。  相似文献   

10.
Element concentration data for a set of silicate igneous rocks have been determined by four independent analytical methods: inductivelycoupled plasma emission spectroscopy (ICP), instrumental neutron activation analysis (INAA), x-ray fluorescence (XRF), and isotope dilution mass spectrometry (ID). The results show excellent agreement among elements determined by more than one technique, and demonstrate the suitability of commercially available ICP instrumentation for the routine analysis of geologic material compared to other standard methods.  相似文献   

11.
We report an improved procedure for the determination of the platinum‐group elements (PGE) and Re, and Os isotopes from a single sample aliquot by isotope dilution (ID) using inductively coupled plasma‐mass spectrometry (ICP‐MS) and negative thermal ionisation mass spectrometry (N‐TIMS), respectively. A two‐stage column method was used to purify PGE‐Re from their sample matrix and interfering elements (e.g., Mo, Zr and Hf) after Os had been separated by CCl4 solvent extraction. The first column separation step used cation exchange resin (AG50W‐X8) to concentrate PGE‐Re and some potential interfering elements (e.g., Mo, Zr and Hf). In the second step, N‐benzoyl‐N‐phenylhydroxylamine (BPHA) extraction resin was used to separate PGE‐Re from the remaining interfering elements, which all remained strongly absorbed to the resin. The method was used to determine the PGE and rhenium, and Os isotope ratios in a range of geochemical reference materials (TDB‐1, WGB‐1, BHVO‐2 and UB‐N). The obtained results agree well with those previously published. This new method enables PGE‐Re abundances and Os isotopic ratios to be determined on the same sample digestion, and circumvents the problems created by sample heterogeneity when comparing PGE and Re‐Os isotope data.  相似文献   

12.
Isotope ratios of heavy elements vary on the 1/10000 level in high temperature materials, providing a fingerprint of the processes behind their origin. Ensuring that the measured isotope ratio is precise and accurate depends on employing an efficient chemical purification technique and optimised analytical protocols. Exploiting the disparate speciation of Cu, Fe and Zn in HCl and HNO3, an anion exchange chromatography procedure using AG1‐×8 (200–400 mesh) and 0.4 × 7 cm Teflon columns was developed to separate them from each other and matrix elements in felsic rocks, basalts, peridotites and meteorites. It required only one pass through the resin to produce a quantitative and pure isolate, minimising preparation time, reagent consumption and total analytical blanks. A ThermoFinnigan Neptune Plus MC‐ICP‐MS with calibrator‐sample bracketing and an external element spike was used to correct for mass bias. Nickel was the external element in Cu and Fe measurements, while Cu corrected Zn isotopes. These corrections were made assuming that the mass bias for the spike and analyte element was identical, and it is shown that this did not introduce any artificial bias. Measurement reproducibilities were ± 0.03‰, ± 0.04‰ and ± 0.06‰ (2s) for δ57Fe, δ65Cu and δ66Zn, respectively.  相似文献   

13.
Laser ablation multi-collector mass spectrometry (LA-MC-ICP-MS) has emerged as the technique of choice for in situ measurements of Sr isotopes in geological minerals. However, the method poses analytical challenges and there is no widely adopted standardised approach to collecting these data or correcting the numerous potential isobaric inferences. Here, we outline practical analytical procedures and data reduction strategies to help establish a consistent framework for collecting and correcting Sr isotope measurements in geological materials by LA-MC-ICP-MS. We characterise a new set of plagioclase reference materials, which are available for distribution to the community, and present a new data reduction scheme for the Iolite software package to correct isobaric interferences for different materials and analytical conditions. Our tests show that a combination of Kr-baseline subtraction, Rb-peak-stripping using βRb derived from a bracketing glass reference material, and a CaCa or CaAr correction for plagioclase and CaCa or CaAr + REE2+ correction for rock glasses, yields the most accurate and precise 87Sr/86Sr measurements for these materials. Using the analytical and correction procedures outlined herein, spot analyses using a beam diameter of 100 μm or rastering with a 50–65 μm diameter beam can readily achieve < 100 ppm 2SE repeatability ("internal") precision for 87Sr/86Sr measurements for materials with < 1000 μg g-1 Sr.  相似文献   

14.
Recent analytical developments in germanium stable isotope determination by multicollector ICP‐MS have provided new perspectives for the use of Ge isotopes as geochemical tracers. Here, we report the germanium isotope composition of the NIST SRM 3120a elemental reference solution that has been calibrated relative to internal isotopic standard solutions used in the previous studies. We also intercalibrate several geological reference materials as well as geological and meteoritic samples using different techniques, including online hydride generation and a spray chamber for sample introduction to MC‐ICP‐MS, and different approaches for mass bias corrections such as sample–calibrator bracketing, external mass bias correction using Ga isotopes and double‐spike normalisation. All methods yielded relatively similar precisions at around 0.1‰ (2s) for δ74/70Ge values. Using igneous and mantle‐derived rocks, the bulk silicate Earth (BSE) δ74/70Ge value was re‐evaluated to be 0.59 ± 0.18‰ (2s) relative to NIST SRM 3120a. Several sulfide samples were also analysed and yielded very negative values, down to ?4.3‰, consistent with recent theoretical study of Ge isotope fractionation. The strong heavy isotope depletion in ore deposits also contrasts with the generally positive Ge isotope values found in many modern and ancient marine sediments.  相似文献   

15.
16.
A quadrupole-based mass spectrometer used in static mode has been employed to determine noble gas concentrations of water samples by isotope dilution. Water samples are degassed and spiked with minor isotopes of each noble gas. After separation of the various gas components, the isotopic ratios are measured in the mass spectrometer. Because a spike is added to each sample, the recovery of each gas component does not have to be quantitative. Equilibration temperatures are calculated from the gas concentrations, based on noble gas solubility data. An accuracy of ±1°C, from the air equilibration temperature, is attainable for air-saturated water samples prepared under controlled conditions in the laboratory. The method has been applied to groundwaters from the London Basin Chalk aquifer. The noble-gas-derived temperatures are consistent with climatic conditions prevailing at the periods of recharge.  相似文献   

17.
A new natural zircon reference material SA01 is introduced for U‐Pb geochronology as well as O and Hf isotope geochemistry by microbeam techniques. The zircon megacryst is homogeneous with respect to U‐Pb, O and Hf isotopes based on a large number of measurements by laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) and secondary ion mass spectrometry (SIMS). Chemical abrasion isotope dilution thermal ionisation mass spectrometry (CA‐ID‐TIMS) U‐Pb isotopic analyses produced a mean 206Pb/238U age of 535.08 ± 0.32 Ma (2s, n = 10). Results of SIMS and LA‐ICP‐MS analyses on individual shards are consistent with the TIMS ages within uncertainty. The δ18O value determined by laser fluorination is 6.16 ± 0.26‰ (2s, n = 14), and the mean 176Hf/177Hf ratio determined by solution MC‐ICP‐MS is 0.282293 ± 0.000007 (2s, n = 30), which are in good agreement with the statistical mean of microbeam analyses. The megacryst is characterised by significant localised variations in Th/U ratio (0.328–4.269) and Li isotopic ratio (?5.5 to +7.9‰); the latter makes it unsuitable as a lithium isotope reference material.  相似文献   

18.
High spatial resolution multiple sulfur isotope studies undertaken by multi‐collector secondary ion mass spectrometry (SIMS) commonly use well‐characterised sulfide reference materials that do not (or are assumed not to) exhibit mass‐independent fractionation in 33S and 36S, taking advantage of the three‐isotope plot to evaluate the extent of such fractionation in unknown targets. As a result, few studies to date have used a mass independently fractionated reference sulfide to demonstrate accuracy of measurement and/or data reduction procedures. This article evaluates two mass independently fractionated sulfides, a pyrite from the 3.7 Ga Isua greenstone belt and a pyrrhotite from a 2.7 Ga gold deposit in Minas Gerais, Brazil, which may be used to provide additional confidence in the obtained multiple sulfur isotope data. Additionally, the article presents a method for measuring quadruple sulfur isotopes by SIMS at a comparable spatial and volume resolution to that typically employed for triple sulfur isotopes. This method has been applied to the Isua pyrite as well as to a sample of 2.5 Ga pyrite from the Campbellrand, Transvaal, South Africa, previously investigated using SIMS for triple sulfur isotopes, illustrating its potential for quadruple sulfur investigations.  相似文献   

19.
李津  朱祥坤  唐索寒 《岩矿测试》2011,30(2):138-143
仪器的质量分馏校正是提高同位素分析数据精度的关键。"同位素双稀释剂"的测定方法可实现严格的仪器质量分馏校正。文章以Mo同位素为例,详细介绍了同位素双稀释剂法的原理、计算方法以及应用多接收器等离子体质谱仪(MC-ICP-MS)进行Mo同位素组成高精度分析的方法。双稀释剂和标准样品的100Mo/97Mo使用Pd溶液的104Pd/102Pd标定,其他Mo同位素比值通过100Mo/97Mo标定。对100Mo/95Mo、98Mo/95Mo和97Mo/95Mo三组Mo同位素比值建立3个非线性方程,组成一个非线性方程组,在认为仪器质量分馏和自然分馏都符合指数法则的前提下,通过Taylor公式将非线性方程组转换成线性方程组,使用牛顿迭代法计算出样品的Mo同位素组成。在使用MC-ICP-MS分析过程中,每组数据采集20个数据点,最终的δ100Mo/95Mo、δ98Mo/95Mo和δ97Mo/95Mo是这20组数据得到的20组δ100Mo/95Mo、δ98Mo/95Mo和δ97Mo/95Mo的平均值。  相似文献   

20.
The advent of multiple collector-inductively coupled plasma-mass spectrometry has provided an impetus to the study of isotope abundance variations in natural materials. In particular, the study of "non-traditional" stable isotopes has revealed isotope fractionation variations caused by a range of physiochemical and biological mechanisms. The magnitude of these variations may be < 1 per mil per mass unit, but are significant in terms of the experimental uncertainties involved, provided rigorous mass spectrometric protocols are followed. The double spike technique can be used effectively to evaluate isotope fractionation effects for both multiple collector-inductively coupled plasma-mass spectrometry and thermal ionisation mass spectrometry. The demanding nature of this research implies the need for internationally-accepted reference materials so that interlaboratory comparisons can be made with confidence. At present, isotopically certified reference materials are unavailable for many elements, including Cu, Zn, Mo and Cd, and it is important that this situation be rectified as soon as practicable. Until such time as isotopically certified reference materials become available for every element, stable isotope geochemists should adopt a common reference material as the standard for each element so that rigorous interlaboratory comparisons can be made.  相似文献   