共查询到20条相似文献,搜索用时 15 毫秒
1.
Measurement of dissolved gases in groundwater is becoming increasingly common and important. Many of these measurements involve monitoring or sampling within wells or from water pumped from wells. We used total dissolved gas pressure (TDGP) sensors placed in the screened section of various wells (4 to 72 m deep) to assess the dissolved gas conditions for open wells compared to the conditions when sealed (i.e., isolated from the atmosphere) with a hydraulic packer (one well) or when pumped. When the packer was installed (non-pumping conditions), TDGP rose from <1.7 to >3.1 atm (<172 to >314 kPa), with declines noted when the packer was removed or deflated. While pumping, TDGP measured in many of the wells rose to substantially higher levels, up to 4.0 atm (408 kPa) in one case. Thus, when groundwater is gas charged, the background aquifer TDGP, and likewise the dissolved gas concentrations, may be substantially higher than initially measured in open wells, indicating significant in-well degassing. This raises concerns about past and current methods of measuring the dissolved gases in groundwater. Additional procedures that may be required to obtain representative measurements from wells include (1) installing in-well hydraulic packers to seal the well, or (2) pumping to bring in fresh groundwater. However, observed transient decreased TDGPs during pumping, believed to result from gas bubble formation induced by drawdown in the well below a critical pressure (relative to TDGP), may disrupt the measurements made during or after pumping. Thus, monitoring TDGP while pumping gas-charged wells is recommended. 相似文献
2.
Abdul S. Abdul Sheila F. Kia Thomas L. Gibson 《Ground Water Monitoring & Remediation》1989,9(2):90-99
Theoretical analysis and laboratory column experiments were carried out to investigate the conditions required for petroleum products (oil) to flow into a well installed through a sandy porous medium contaminated with the oil. The results indicated that oil would flow into a well only after a layer of "free oil" is formed in the adjacent porous medium. Because significant quantities of oil could be stored in the porous medium under the influence of capillary suction prior to the formation of the zone of free oil, the presence of oil in a well would indicate an advanced stage of oil contamination of the subsurface. While monitoring wells could be used to delineate the extent of the free-oil plume and the plume of dissolved petroleum constituents, they are not useful for delineating the extent of capillary held oil.
The experimental results also indicated that the ratio of the oil-layer thickness in the well to that in the porous medium is not a constant as is sometimes assumed in practice. Further, estimates of the oil thickness in the medium based on the oil thickness in wells and on capillary properties measured in the laboratory were sensitive to the values of the parameters used in these estimates. The measured thickness of the oil layer in a monitoring well alone may not yield reliable estimates of the amount of oil in the subsurface, and assuming that the oil-thickness ratio is a constant can lead to inadequate site assessments and inappropriate remedial plans. 相似文献
The experimental results also indicated that the ratio of the oil-layer thickness in the well to that in the porous medium is not a constant as is sometimes assumed in practice. Further, estimates of the oil thickness in the medium based on the oil thickness in wells and on capillary properties measured in the laboratory were sensitive to the values of the parameters used in these estimates. The measured thickness of the oil layer in a monitoring well alone may not yield reliable estimates of the amount of oil in the subsurface, and assuming that the oil-thickness ratio is a constant can lead to inadequate site assessments and inappropriate remedial plans. 相似文献
3.
4.
5.
Computation of Type Curves for Flow to Partially Penetrating Wells in Water-Table Aquifers 总被引:2,自引:0,他引:2
Allen F. Moench 《Ground water》1993,31(6):966-971
6.
7.
Influence of Hydraulic Fracturing on Overlying Aquifers in the Presence of Leaky Abandoned Wells 下载免费PDF全文
The association between hydrocarbon‐rich reservoirs and organic‐rich source rocks means unconventional oil and gas plays usually occur in mature sedimentary basins—where large‐scale conventional development has already taken place. Abandoned wells in proximity to hydraulic fracturing could be affected by increased fluid pressures and corresponding newly generated fractures that directly connect (frac hit) to an abandoned well or to existing fractures intersecting an abandoned well. If contaminants migrate to a pathway hydraulically connected to an abandoned well, upward leakage may occur. Potential effects of hydraulic fracturing on upward flow through a particular type of leaky abandoned well—abandoned oil and gas wells converted into water wells were investigated using numerical modeling. Several factors that affect flow to leaky wells were considered including proximity of a leaky well to hydraulic fracturing, flowback, production, and leaky well abandonment methods. The numerical model used historical records and available industry data for the Eagle Ford Shale play in south Texas. Numerical simulations indicate that upward contaminant migration could occur through leaky converted wells if certain spatial and hydraulic conditions exist. Upward flow through leaky converted wells increased with proximity to hydraulic fracturing, but decreased when flowback and production occurred. Volumetric flow rates ranged between 0 and 0.086 m3/d for hydraulic‐fracturing scenarios. Potential groundwater impacts should be paired with plausible transport mechanisms, and upward flow through leaky abandoned wells could be unrelated to hydraulic fracturing. The results also underscore the need to evaluate historical activities. 相似文献
8.
A new type of vertical circulation well (VCW) is used for groundwater dewatering at construction sites. This type of VCW consists of an abstraction screen in the upper part and an injection screen in the lower part of a borehole, whereby drawdown is achieved without net withdrawal of groundwater from the aquifer. The objective of this study is to evaluate the operation of such wells including the identification of relevant factors and parameters based on field data of a test site and comprehensive numerical simulations. The numerical model is able to delineate the drawdown of groundwater table, defined as free‐surface, by coupling the arbitrary Lagrangian–Eulerian algorithm with the groundwater flow equation. Model validation is achieved by comparing the field observations with the model results. Eventually, the influences of selected well operation and aquifer parameters on drawdown and on the groundwater flow field are investigated by means of parameter sensitivity analysis. The results show that the drawdown is proportional to the flow rate, inversely proportional to the aquifer conductivity, and almost independent of the aquifer anisotropy in the direct vicinity of the well. The position of the abstraction screen has a stronger effect on drawdown than the position of the injection screen. The streamline pattern depends strongly on the separation length of the screens and on the aquifer anisotropy, but not on the flow rate and the horizontal hydraulic conductivity. 相似文献
9.
A process-based methodology was used to compare the vulnerability of public supply wells tapping seven study areas in four hydrologically distinct regional aquifers to volatile organic compound (VOC) contamination. This method considers (1) contributing areas and travel times of groundwater flowpaths converging at individual supply wells, (2) the oxic and/or anoxic conditions encountered along each flowpath, and (3) the combined effects of hydrodynamic dispersion and contaminant- and oxic/anoxic-specific biodegradation. Contributing areas and travel times were assessed using particle tracks generated from calibrated regional groundwater flow models. These results were then used to estimate VOC concentrations relative to an unspecified initial concentration (C/C0) at individual public supply wells. The results show that the vulnerability of public supply wells to VOC contamination varies widely between different regional aquifers. Low-recharge rates, long travel times, and the predominantly oxic conditions characteristic of Basin and Range aquifers in the western United States leads to lower vulnerability to VOCs, particularly to petroleum hydrocarbons such as benzene and toluene. On the other hand, high recharge rates and short residence times characteristic of the glacial aquifers of the eastern United States leads to greater vulnerability to VOCs. These differences lead to distinct patterns of C/C0 values estimated for public supply wells characteristic of each aquifer, information that can be used by resource managers to develop monitoring plans based on relative vulnerability, to locate new public supply wells, or to make land-use management decisions. 相似文献
10.
11.
12.
Storage of water in aquifers using injection wells is an efficient way for utilizing excess desalinated water in arid regions. In this investigation we estimate the benefits of optimally recharging seasonal surplus desalinated water into a strategic coastal aquifer already benefitting from natural recharge of flash-floods water by a recharge dam. Since, usually the buyers of desalinated water commit to purchase surplus desalinated water under take-or-pay contracts, any attempt in utilizing the paid water is beneficial. Coastal cities are observing an increased urbanization leaving limited space for aquifer recharge infrastructure. In order to determine the optimal location of wells and maximize the use of surplus desalinated water available in winter period, a decision tool combining a numerical groundwater flow simulation model (MODFLOW) with an optimization model is developed. The results of this study show that increasing the number of wells from the existing 45 wells to 173 would allow storing 31.4 million cubic meter per year of excess desalinated water into the aquifer that can be used during later during summer months. The net benefit would reach US$55 million/year while the cost of drilling the new wells is US$5.11 million. 相似文献
13.
14.
15.
16.
17.
Haim Gvirtzman 《Ground Water Monitoring & Remediation》2013,33(3):101-110
This study deals with the reliability of monitoring the transition zone between fresh and saline waters in coastal aquifers, considering the effect of tides in long‐perforated boreholes. Electric conductivity (EC) fluctuations in the coastal aquifer of Israel, as measured in long‐perforated borehole, were found to have the same periodicities as the sea tide, though some orders of magnitude larger than sea‐level or groundwater level fluctuations. Direct measurements in the aquifer through buried EC sensors demonstrate that EC measurements within the long‐perforated boreholes might be distorted due to vertical flow in the boreholes, whereas actual fluctuations of the transition zone within the aquifer are some orders of magnitude smaller. Considering these field data, we suggest that monitoring of the transition zone between fresh and saline water adjacent to the sea through long‐perforated boreholes is unreliable. EC fluctuations in short‐perforated boreholes (1 m perforation at the upper part of the transition zone) were somewhat larger than in the aquifer, but much smaller than those in the long‐perforated borehole. The short‐perforation diminishes the vertical flow and the distortion and therefore is more reliable for monitoring the transition zone in the shoreline vicinity. 相似文献
18.
19.
This study tests the feasibility of an aquifer remediation concept proposed by Gvirtzman and Gorelick (1992) that involves the removal of volatile organic compounds (VOCs) dissolved in ground water. The principal is 10 inject air into a well, creating airlift pumping, which is used as a means of in-well vapor stripping. The partially treated water is diverted away from the well and infiltrates back to the water table, thus allowing remediation of a larger aquifer volume.
A remediation well prototype, constructed in a laboratory aquifer model, was used to demonstrate the processes involved. The removal rates of trichloroethylene, toluene, and chloroform were monitored using eight triple-level observation wells. The continuous decrease of VOC concentrations during the short-term experiment has yielded macroscopic evidence that the process offers some promise. It was found that the flow field in the saturated zone. involving the continuous water circulation between the pumping well and the recharging area, caused temporal and spatial variation in remediation efficiency. 相似文献
A remediation well prototype, constructed in a laboratory aquifer model, was used to demonstrate the processes involved. The removal rates of trichloroethylene, toluene, and chloroform were monitored using eight triple-level observation wells. The continuous decrease of VOC concentrations during the short-term experiment has yielded macroscopic evidence that the process offers some promise. It was found that the flow field in the saturated zone. involving the continuous water circulation between the pumping well and the recharging area, caused temporal and spatial variation in remediation efficiency. 相似文献
20.
A six year field experiment has shown that a sand-bentonite mixture used to seal monitoring wells in aquitards contributes solutes to the ground water sampled from these wells. Monitoring wells were installed at field sites with hydraulic conductivity (K) ranging from 5 × 10 -9 m/s to 3 × 1011 m/s. In most cases the boreholes remained dry during installation which allowed the placement of a dry powdered bentonite/sand mixture tagged with potassium bromide (KBr) to seal and separate sampling points. Over six years, wells were sampled periodically and ground-water samples were analyzed for Br and Cl and other major ions. Typical Br results ranged from 10 mg/1 to 35 mg/1 in the first 700 days, as compared to an estimated initial concentration in the seal material of about 75 mg/1. After six years the bromide concentrations had decreased to between 3 mg/1 and 5 mg/1. The total mass of Br removed in six years is less than 50% of that placed; therefore the contamination effects, although considerably diminished, persist. The trends of Br, Cl, Na, and SO4 indicate that varying degrees of contamination occur. These data show that the materials used to seal monitoring wells in aquitards can have a significant and long-lasting impact on the chemistry of the water in the wells. 相似文献