首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
A coring device has been developed to obtain long and minimally disturbed samples of saturated cohesionless sand and gravel. The coring device, which includes a wireline and piston, was developed specifically for use during hollow-stem auger drilling but it also offers possibilities for cable tool and rotary drilling. The core barrel consists of an inner liner made of inexpensive aluminum or plastic tubing, a piston for core recovery, and an exterior steel housing that protects the liner when the core barrel is driven into the aquifer. The core barrel, which is approximately 1.6m (5.6 feet) long, is advanced ahead of the lead auger by hammering at the surface on drill rods that are attached to the core barrel. After the sampler has been driven 1.5m (5 feet), the drill rods are detached and a wireline is used to hoist the core barrel, with the sample contained in the aluminum or plastic liner, to the surface. A vacuum developed by the piston during the coring operation provides good recovery of both the sediment and aquifer fluids contained in the sediment. In the field the sample tubes can be easily split along their length for on-site inspection or they can be capped with the pore water fluids inside and transported to the laboratory. The cores are 5cm (2 inches) in diameter by 1.5m (5 feet) long. Core acquisition to depths of 35m (115 feet), with a recovery greater than 90 percent, has become routine in University of Waterloo aquifer studies. A large diameter (12.7cm [5 inch]) version has also been used successfully. Nearly continuous sample sequences from sand and gravel aquifers have been obtained for studies of sedimentology, hydraulic conductivity, hydrogeochemistry and microbiology.  相似文献   

5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
More than 200,000 gallons of automatic transmission fluid (ATF) leaked from an underground storage tank system and contaminated an area of about 64,000 ft2 of a soil and ground water system. A pumping strategy for improved drainage and recovery of free oil was developed, tested in a laboratory model aquifer, and implemented and evaluated at the field site. This pumping strategy differs from conventional approaches in two important ways: (1) The oil recovery rate is carefully controlled to maximize the pumping rate while maintaining continuity between the oil layer in the soil and the recovery well, to avoid isolation of the oil in the subsurface; and (2) The rate of ground water pumping is controlled to maintain the depressed oil/water interface at its prepumped position. This approach prevents further spread of oil into the ground water, prevents reduction in the volume of recoverable oil due to residual retention, and maintains a gradient for oil flow toward the recovery well. In a model aquifer study, nearly 100 percent of the recoverable volume of ATF was pumped from the system, and about 56,000 gallons of the ATF has been recovered from the field site.  相似文献   

16.
17.
18.
19.
Well-dated records of tropical glacier fluctuations are essential for developing hypotheses and testing proposed mechanisms for past climate changes. Since organic material for radiocarbon dating is typically scarce in low-latitude, high-altitude environments, surface exposure-age dating, based on the measurement of in situ produced cosmogenic nuclides, provides much of the chronologic information on tropical glacier moraines. Here, we present a locally calibrated 10Be production rate for a low-latitude, high-altitude site near Quelccaya Ice Cap (∼13.95°S, 70.89°W, 4857 m asl) in the southeastern Peruvian Andes. Using an independent age (12.35 +0.2, −0.02 ka) of the late glacial Huancané IIa moraines based on thirty-four bracketing radiocarbon ages and twelve 10Be concentrations of boulders on the moraines, we determine a local production rate of 43.28 ± 2.69 atoms gram−1 year−1 (at g−1 yr−1). Reference 10Be production rates (i.e., production rates by neutron spallation appropriate for sea-level, high-latitude sites) range from 3.97 ± 0.09 to 3.78 ± 0.09 at g−1 yr−1, determined using scaling after Lal (1991) and Stone (2000) and depending on our assumed boulder surface erosion rate. Since our boulder surface erosion rate estimate is a minimum value, these reference production rates are also minimum values. A secondary control site on the Huancané IIIb moraines suggests that the 10Be production rates are at least as low as, or possibly lower than, those derived from the Huancané IIa moraines. These sea-level, high-latitude production rates are at least 11–15% lower than values derived using the traditional global calibration dataset, and they are also lower than those derived from the late glacial Breque moraine in the Cordillera Blanca of Peru. However, our sea-level, high-latitude production rates agree well with recently published, locally calibrated production rates from the Arctic, New Zealand, and Patagonia. The production rates presented here should be used to calculate 10Be exposure ages in low-latitude, high-altitude locations, particularly in the tropical Andes, and should improve the ability to compare the results of studies using 10Be exposure-age dating with other chronological data.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号