首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Increasingly, regulations by federal, state and local agencies are being developed that require the installation of vadose zone monitoring systems for hazardous chemical facilities in addition to, or in lieu of, conventional ground water monitoring wells. Compared to a ground water monitoring approach, vadose zone monitoring systems may permit earlier detection of chemical leakage and less costly cleanup of contamination. The effective use of vadose zone monitoring systems in detecting contamination depends on many factors. Without proper consideration of these factors, a vadose zone monitoring system may not give as high a level of reliability as a ground water monitoring system.
Major factors to consider in installing a vadose zone monitoring system are: type of instrument to use, number of instruments, depth and location of instruments, and frequency of monitoring. Means to evaluate these factors in a comprehensive fashion have been lacking. Based on recent experience in installing and operating vadose zone monitoring systems, criteria and methods useful in resolving the preceding factors have been developed. Types of instruments can be classified as either direct (lysimeter, vapor probe) or indirect (tensiometer, conductivity probe). A combination of the two is needed for reliability. The depth, location and number of instruments depend on the geometry of the facility, the number and size of likely contaminant leakage points in engineered barriers, properties of the material being monitored, the effective radius of monitoring for each instrument, vadose zone properties, and types of remedial actions that are available. The freqency of monitoring largely depends on the rate of movement of the contaminant. Evaluating the preceding factors requires some level of modeling and preliminary field testing.  相似文献   

2.
Contaminants may persist for long time periods within low permeability portions of the vadose zone where they cannot be effectively treated and are a potential continuing source of contamination to ground water. Setting appropriate vadose zone remediation goals typically requires evaluating these persistent sources in terms of their impact on meeting ground water remediation goals. Estimating the impact on ground water can be challenging at sites with low aqueous recharge rates where vapor-phase movement is the dominant transport process in the vadose zone. Existing one-dimensional approaches for simulating transport of volatile contaminants in the vadose zone are considered and compared to a new flux-continuity-based assessment of vapor-phase contaminant movement from the vadose zone to the ground water. The flux-continuity-based assessment demonstrates that the ability of the ground water to move contaminant away from the water table controls the vapor-phase mass flux from the vadose zone across the water table. Limitations of these approaches are then discussed with respect to the required assumptions and the need to incorporate three-dimensional processes when evaluating vapor-phase transport from the vadose zone to the ground water. The carbon tetrachloride plume at the U.S. Department of Energy Hanford Site is used as the example site where persistent vadose zone contamination needs to be considered in the context of ground water remediation.  相似文献   

3.
A systematic approach is presented for the design of a multiphase vadose zone monitoring system recognizing that, as in ground water monitoring system design, complete subsurface coverage is not practical. The approach includes identification and prioritization of vulnerable areas: select ion of cost-effective indirect monitoring methods that will provide early warning of contaminant migration: selection of direct monitoring methods for diagnostic confirmation; identification of background monitoring locations; and identification of an appropriate temporal monitoring plan. An example of a monitoring system designed for a solid waste landfill is presented and utilized to illustrate the approach and provide details of system implementation. The example design described incorporates the use of neutron moisture probes deployed in both vertical and horizontal access tubes beneath the lcachate recovery collection system of the landfill. Early warning of gaseous phase contaminant migration is monitored utilizing whole-air active soil gas sampling points deployed in gravel- filled trenches beneath the subgrade. Diagnostic confirmation of contaminant migration is provided utilizing pore- liquid samplers. Conservative tracers can be used to distinguish between chemical species released by a landfill from those attributable to other (e.g. off-site) sources or present naturally in the subsurface. A discussion of background monitoring point location is also presented.  相似文献   

4.
A study on flood water infiltration and ground water recharge of a shallow alluvial aquifer was conducted in the hyperarid section of the Kuiseb River, Namibia. The study site was selected to represent a typical desert ephemeral river. An instrumental setup allowed, for the first time, continuous monitoring of infiltration during a flood event through the channel bed and the entire vadose zone. The monitoring system included flexible time domain reflectometry probes that were designed to measure the temporal variation in vadose zone water content and instruments to concurrently measure the levels of flood and ground water. A sequence of five individual floods was monitored during the rainy season in early summer 2006. These newly generated data served to elucidate the dynamics of flood water infiltration. Each flood initiated an infiltration event which was expressed in wetting of the vadose zone followed by a measurable rise in the water table. The data enabled a direct calculation of the infiltration fluxes by various independent methods. The floods varied in their stages, peaks, and initial water contents. However, all floods produced very similar flux rates, suggesting that the recharge rates are less affected by the flood stages but rather controlled by flow duration and available aquifer storage under it. Large floods flood the stream channel terraces and promote the larger transmission losses. These, however, make only a negligible contribution to the recharge of the ground water. It is the flood duration within the active streambed, which may increase with flood magnitude that is important to the recharge process.  相似文献   

5.
Fritz BG  Arntzen EV 《Ground water》2007,45(6):753-760
Measurement of ground water/surface water interaction within the hyporheic zone is increasingly recognized as an important aspect of subsurface contaminant fate and transport. Understanding the interaction between ground water and surface water is critical in developing a complete conceptual model of contaminant transport through the hyporheic zone. At the Hanford Site near Richland, Washington, ground water contaminated with uranium discharges to the Columbia River through the hyporheic zone. Ground water flux varies according to changes in hydraulic gradient caused by fluctuating river stage, which changes in response to operation of dams on the Columbia River. Piezometers and continuous water quality monitoring probes were installed in the hyporheic zone to provide long-term, high-frequency measurement of hydraulic gradient and estimated uranium concentrations. Subsequently, the flux of water and uranium was calculated for each half-hour time period over a 15-month study period. In addition, measurement of water levels in the near-shore unconfined aquifer enhanced the understanding of the relationship between river stage, aquifer elevation, and uranium flux. Changing river stage resulted in fluctuating hydraulic gradient within the hyporheic zone. Further, influx of river water caused lower uranium concentrations as a result of dilution. The methods employed in this study provide a better understanding of the interaction between surface and ground water in a situation with a dynamically varying vertical hydraulic gradient and illustrate how the combination of relatively standard methods can be used to derive an accurate estimation of water and contaminant flux through the hyporheic zone.  相似文献   

6.
Accurate representation of artificial recharge is requisite to calibration of a ground water model of an unconfined aquifer for a semiarid or arid site with a vadose zone that imparts significant attenuation of liquid transmission and substantial anthropogenic liquid discharges. Under such circumstances, artificial recharge occurs in response to liquid disposal to the vadose zone in areas that are small relative to the ground water model domain. Natural recharge, in contrast, is spatially variable and occurs over the entire upper boundary of a typical unconfined ground water model. An improved technique for partitioning artificial recharge from simulated total recharge for inclusion in a ground water model is presented. The improved technique is applied using data from the semiarid Hanford Site. From 1944 until the late 1980s, when Hanford's mission was the production of nuclear materials, the quantities of liquid discharged from production facilities to the ground vastly exceeded natural recharge. Nearly all hydraulic head data available for use in calibrating a ground water model at this site were collected during this period or later, when the aquifer was under the diminishing influence of the massive water disposals. The vadose zone is typically 80 to 90 m thick at the Central Plateau where most production facilities were located at this semiarid site, and its attenuation of liquid transmission to the aquifer can be significant. The new technique is shown to improve the representation of artificial recharge and thereby contribute to improvement in the calibration of a site-wide ground water model.  相似文献   

7.
Currently, vadose zone monitoring is required under the Resource Conservation and Recovery Act (RCRA) only at land treatment facilities. Contaminant leak detection through ground water monitoring is very important, but it is considered to be after the fact. Remedial action costs can be reduced considerably by monitoring the vadose zone for compounds that exhibit high rates of movement. Volatile organic compounds (VOCs) exhibit this property and are present at many municipal landfills, recycling facilities, and treatment storage and disposal facilities (TSDFs). Through the authors'personal experience, it has been noted that gaseous phase transport of VOCs through the vadose zone is at least an order of magnitude greater than advective transport of VOCs in ground water. Therefore, VOCs in soil gas are an effective early warning leak detection parameter. Downward movement of leachate can be intercepted by porous cup lysimeters. Attenuation in the vadose zone slows the apparent movement of contaminants; however, it is only a matter of time before leachate reaches the water table. The authors believe that soil-gas and pore-water monitoring should and eventually will be required at all RCRA sites. If vadose zone monitoring becomes an additional requirement under RCRA, both the facility owner and the taxpayer will benefit. During the interim, facility owners can benefit by employing vadose zone monitoring techniques coupled with either qualitative or quantitative chemical analyses.  相似文献   

8.
Design Screening Tools for Passive Funnel and Gate Systems   总被引:1,自引:0,他引:1  
The funnel and gate remediation concept (Star and Cherry 1993) represents a promising, yet relatively under-developed, technology for the passive control and in situ remediation of contaminated ground water. Effective design and implementation of such a system may, however, prove difficult under conditions of large or unpredictable variations in contaminant migration or ground water flow.
Numerical modeling of two-dimensional ground water flow has been used to predict the hydraulic performance of passive, straight, or winged funnel and gate configurations over a range of hydrogeologic and ambient ground water flow conditions. The results of these analyses were used to construct generic correlation diagrams relating upstream capture zone or gale through put to the barrier, gale, and aquifer characteristics. These diagrams serve as useful screening tools to (1) quantitatively estimate the capture zone of pre-determined funnel and gale configurations, or (2) develop preliminary funnel and gale designs that will yield a desired capture zone, independent of aquifer characteristics.  相似文献   

9.
Low-permeability layers of the vadose zone containing volatile organic compounds (VOCs) may persist as source zones for long time periods and may provide contamination to groundwater. At sites with low recharge rates, where vapor migration is the dominant transport process, the impact of vadose zone sources on groundwater may be difficult to assess. Typical assessment methods include one-dimensional numerical and analytical techniques. The one-dimensional approaches only consider groundwater coupling options through boundary conditions at the water table and may yield artificially high mass flux results when transport is assumed to occur by gas-phase diffusion between a source and an interface with a zero concentration boundary condition. Improvements in mass flux assessments for VOCs originating from vadose zone sources may be obtained by coupling vadose zone gas transport and dissolved contaminant transport in the saturated zone and by incorporating the inherent three-dimensional nature of gas-phase transport, including the potential of density-driven advection. This paper describes a series of three-dimensional simulations using data from the U.S. Department of Energy's Hanford site, where carbon tetrachloride is present in a low-permeability zone about 30 m above the groundwater. Results show that, for most cases, only a relatively small amount of the contaminant emanating from the source zone partitions into the groundwater and that density-driven advection is only important when relatively high source concentrations are considered.  相似文献   

10.
The U.S. Environmental Protection Agency (EPA) recently proposed to amend federal regulations to require vadose zone monitoring at certain hazardous waste facilities. To support this proposal, EPA evaluated previous policy on vadose zone monitoring and examined advances in vadose zone monitoring technology. Changes in EPA vadose zone monitoring policy were driven by demonstrated advances in the available monitoring technology and improvements in understanding of vadose zone processes/When used under the appropriate conditions, currently available direct and indirect monitoring methods can effectively detect contamination that may leak from hazardous waste facilities into the vadose zone. Direct techniques examined include soil-core monitoring and soil-pore liquid monitoring. Indirect techniques examined include soil-gas monitoring, neutron moderation, complex resistivity, ground-penetrating radar, and electrical resistivity. Properly designed vadose zone monitoring networks can act as a complement to saturated zone monitoring networks at numerous hazardous waste facilities. At certain facilities, particularly those in arid climates where the saturated zone is relatively deep, effective vadose zone monitoring may allow a reduction in the scope of saturated zone monitoring programs.  相似文献   

11.
Recharge processes of karst aquifers are difficult to assess given their strong heterogeneity and the poorly known effect of vadose zone on infiltration. However, recharge assessment is crucial for the evaluation of groundwater resources. Moreover, the vulnerability of karst aquifers depends on vadose zone behaviour because it is the place where most contamination takes place. In this work, an in situ experimental approach was performed to identify and quantify flow and storage processes occurring in karst vadose zone. Cave percolation monitoring and dye tracing were used to investigate unsaturated zone hydrological processes. Two flow components (diffuse and quick) were identified and, respectively, account for 66% and 34% of the recharge. Quickflow was found to be the result of bypass phenomenon in vadose zone related to water saturation. We identify the role of epikarst as a shunting area, most of the storage in the vadose zone occurring via the diffuse flow component in low permeability zones. Relationship between rainfall intensity and transit velocity was demonstrated, with 5 times higher velocities for the quick recharge mode than the diffuse mode. Modelling approach with KarstMod software allowed to simulate the hybrid recharge through vadose zone and shows promising chances to properly assess the recharge processes in karst aquifer based on simple physical models.  相似文献   

12.
Traditional monitoring methods using chemical analysis of ground water samples to detect pollutant migration are being superseded or used in conjunction with innovative approaches. A need to detect pollutants before they reach the water table has drawn interest to vadose (unsaturated) zone monitoring and brought together hydrogeologists, soil scientists and agricultural engineers who have been working on this subject for years.
Recent studies have identified over 50 different types of vadose zone monitoring devices and methods that have optimum utility in varying hydrogeologic settings. In general, measurements made in the vadose zone are trying to define storage, transmission of liquid waste in terms of flux and velocity, and pollutant mobility.
Criteria for the selection of alternative vadose zone monitoring methods are important for the development of site-specific systems. These criteria include: type of site; applicability to new, active, and abandoned sites; power requirements; depth limitations; multiple use capability; type of data collection system; reliability and life expectancy; degree of operational complexity; direct versus indirect methods; applicability to alternate media; effect on flow regime; and effect of hazardous waste on sampling or measurements. Application of the selection criteria is discussed in Everett et al. (1982a).  相似文献   

13.
The vadose zone is the main region controlling water movement from the land surface to the aquifer and has a very complex structure. The use of non-invasive or minimally invasive geophysical methods especially electrical resistivity imaging is a cost-effective approach adapted for long-term monitoring of the vadose zone. The main aim of this work is to know the fractures in the vadose zone, of granitic terrene, through which the recharge or preferred path recharge to the aquifer takes place and thus to relate moisture and electrical resistivity. Time lapse electrical resistivity tomography (TLERT) experiment was carried out in the vadose zone of granitic terrene at the Indian Geophysical Research Institute, Hyderabad along two profiles to a depth of 18 m and 13 m each. The profiles are 300 m apart. Piezometric, rainfall and soil moisture data were recorded to correlate with changes in the rainfall recharge. These TLERT difference images showed that the conductivity distribution was consistent with the recharge occurring along the minor fractures. We mapped the fractures in hard rock or granites to see the effect of the recharge on resistivity variation and estimation of moisture content. These fractures act as the preferred pathways for the recharge to take place. A good correlation between the soil moisture and resistivity is established in the vadose zone of granitic aquifer. Since the vadose zone exhibits extremely high variability, both in space and time, the surface geophysical investigations such as TLERT have been a simple and useful method to characterize the vadose zone, which would not have been possible with the point measurements alone. The analyses of the pseudosection with time indicate clearly that the assumption of the piston flow of the moisture front is not valid in hard rocks. The outcome of this study may provide some indirect parameters to the well known Richard's equation in studying the unsaturated zone.  相似文献   

14.
Anthropogenic agricultural chemicals of concern in ground water include nitrate and pesticides. Increased legislation and regulation of contaminant levels in ground water can be expected. Ground water contamination should be prevented from getting worse, but more research is necessary so as to base regulations on sound criteria. Health effects and acceptable risks must be better formulated. More research on chemical movement in the vadose zone is necessary for accurate predictive modeling of pesticide transport to ground water. Best management practices need to be developed so that farmers will be able to farm profitably while complying with regulations for maximum contaminant levels in underlying ground water. People from all concerned disciplines, citizens'groups, and policy-makers need to work together to develop realistic regulatory policies and management practices that will effectively protect public health while ensuring a viable and sustainable agriculture.  相似文献   

15.
Fractured shales of the Brunswick Formation provide a major aquifer in the most industrialized region of New Jersey. Numerous cases of ground water contamination have been documented in this formation. However, effectiveness of monitoring and remediation efforts is often hampered by the use of inappropriate concepts regarding ground water flow controls in this complex aquifer system. One such concept presumes that near-vertical fractures parallel to the strike of beds provide principal passages for the flow and produce an anisotropic response to pumping stress. Field evidence presented in this paper confirms that the Brunswick Formation hosts a gently dipping, multiunit, leaky aquifer system that consists of thin water-bearing units and thick intervening aquitards. The water-bearing units are associated with major bedding partings and/or intensely fractured seams. Layered heterogeneity of such a dipping multiunit aquifer system produces an anisotropic flow pattern with preferential flow along the strike of beds. Within the weathered zone, the permeability of the water-bearing units can be greatly reduced. The commonly used hydrogeologic model of the Brunswick as a one-aquifer system, sometimes with vaguely defined "shallow" and "deep" zones, often leads to the development of inadvertent cross-flows within monitoring wells. If undetected, cross-flows may promote contaminant spread into deeper units and impair the quality of hydrogeologic data. Hydrogeologic characterization of the Brunswick shales at any given site should be aimed primarily at identification of the major water-bearing and aquitard units. Recommended techniques for this characterization include fluid logging and other in-well tests.  相似文献   

16.
The screened auger is a laser-slotted, hollow-stem auger through which a representative sample of ground water is pumped from an aquifer and tested for water-quality parameters by appropriate field-screening methods. Screened auger sampling can be applied to ground water quality remedial investigations, providing:(1) a mechanism for determining a monitoring well's optimal screen placement in a contaminant plume; and (2) data to define the three-dimensional configuration of the contaminant plume.
Screened auger sampling has provided an efficient method for investigating hexavalent chromium and volatile organic compound contamination in two sandy aquifers in Cadillac, Michigan. The aquifers approach 200 feet in thickness and more than 1 square mile in area. A series of screened auger borings and monitoring wells was installed, and ground water was collected at 10-foot intervals as the boreholes were advanced to define the horizontal and vertical distribution of the contaminant plumes. The ability of the screened auger to obtain representative ground water samples was supported by the statistical comparison of field screening results and subsequent laboratory analysis of ground water from installed monitoring wells.  相似文献   

17.
Bayless ER 《Ground water》2001,39(2):169-180
The vadose zone was examined as an environmental compartment where significant quantities of atrazine and its degradation compounds may be stored and transformed. The vadose zone was targeted because regional studies in the White River Basin indicated a large discrepancy between the mass of atrazine applied to fields and the amount of the pesticide and its degradation compounds that are measured in ground and surface water. A study site was established in a rotationally cropped field in the till plain of central Indiana. Data were gathered during the 1994 growing season to characterize the site hydrogeology and the distribution of atrazine, desethylatrazine, deisopropylatrazine, didealkylatrazine and hydroxyatrazine in runoff, pore water, and ground water. The data indicated that atrazine and its degradation compounds were transported from land surface to a depth of 1.5 m within 60 days of application, but were undetected in the saturated zone at nearby monitoring wells. A numerical model was developed, based on the field data, to provide information about processes that could retain and degrade atrazine in the vadose zone. Simulations indicated that evapotranspiration is responsible for surface directed soil-moisture flow during much of the growing season. This process causes retention and degradation of atrazine in the vadose zone. Increased residence time in the vadose zone leads to nearly complete transformation of atrazine and its degradation products to unquantified degradation compounds. As a result of macropore flow, small quantities of atrazine and its degradation compounds may reach the saturated zone.  相似文献   

18.
Cleanup standards for volatile organic compounds in thick vadose zones can be based on indirect risk (transport to ground water) when contamination is below depths of significant direct risk. At one Arizona Superfund site, a one-dimensional vadose zone transport model (VLE-ACH) was used to estimate the continued transport of VOCs from the vadose zone to ground water. VLEACH is a relatively simple and readily available model that proved useful for estimating indirect risk from VOCs in the vadose zone at this site. The estimates of total soil concentrations used as initial conditions for VLF.ACH incorporated a variety of data from the site. Soil gas concentrations were found to be more useful than soil matrix data for estimating total soil concentrations at this arid-zone site. A simple mixing cell model was used with the VLEACH-derived mass loading estimates from the vadose zone over time to estimate the resulting changes in ground water concentrations. For this site, the results of the linked VLEACH/mixing cell simulations indicate it is likely that the federal MCI. for TCE will be exceeded in underlying ground water if remedial action on I he vadose zone is not pursued.  相似文献   

19.
Volatile organic compounds delected in ground water from wells at Test Area North (TAN) at the Idaho National Engineering Laboratory (INEL) prompted RCRA facility investigations in 1989 and 1990 and a CERCLA-driven RI/FS in 1992. In order to address ground water treatment feasibility, one of the main objectives, of the 1992 remedial investigation was to determine the vertical extent of ground water contamination, where the principle contaminant, of concern is trichloroethylene (TCE). It was hypothesized that a sedimentary interbed at depth in the fractured basalt aquifer could be inhibiting vertical migration of contaminants to lower aquifers. Due to the high cost of drilling and installation of ground water monitoring wells at this facility (greater than $100,000 per well), a real time method was proposed for obtaining and analyzing ground water samples during drilling to allow accurate placement of well screens in zones of predicted VOC contamination. This method utilized an inflatable pump packer pressure transducer system interfaced with a datalogger and PC at land surface. This arrangement allowed for real lime monitoring of hydraulic head above and below the packer to detect leakage around the packer during pumping and enabled collection of head data during pumping for estimating hydrologic properties. Analytical results were obtained in about an hour from an on-site mobile laboratory equipped with a gas chromalograplvmass spectrometer (GC/MS). With the hydrologic and analytical results in hand, a decision was made to either complete the well or continue drilling to the next test zone. In almost every case, analytical results of ground water samples taken from the newly installed wells closely replicated the water quality of ground water samples obtained through the pump packer system.  相似文献   

20.
Seepage from tailings ponds associated with an active uranium mill in Utah has resulted in contamination of ground water contained in the Dakota-Burro Canyon Formation. This aquifer is used in the area as a supply for domestic and industrial wells.
Results of very low-frequency electromagnetic surveys and ground water quality investigations at the site indicated that the flow of ground water and contaminants is primarily fracture-controlled. Pumping tests were conducted to determine the hydraulic characteristics of the fractured system. The extent of contaminant migration was then determined using an analytical model of transport in fractured aquifers.
Based on these investigations, a plan was designed to control future and remediate past ground water contamination. This plan consists of pumping from a single well intersecting the main fracture that transports contaminants off the site. The effectiveness of the plan was analytically modeled, taking account of the anisotropy of the ground water system. Subsequent monitoring of water levels in the area indicates that the plan has been effective since its inception in November 1983.  相似文献   