首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
针对结构动态响应监测三维变形的需求,研究立体视觉三维测量算法,建立基于结构测面的世界坐标系,得到结构振动响应三维位移公式.研究圆形标识点边缘检测、中心拟合及匹配约束算法,编译基于MATLAB平台的立体视觉结构振动测试分析软件.使用本文集成的立体视觉测量系统完成不同加速度峰值Taft波及El Centro波作用下砌体房屋模型振动台试验,同时测得结构三维位移时程曲线.面内位移时程曲线表明立体视觉方法与位移计数据吻合非常好,证实立体视觉测量方法的有效性.离面位移时程曲线表明砌体房屋模型在地震动作用下发生扭转,且随地震动加速度峰值增大,扭转反应加剧,充分验证立体视觉方法用于监测结构三维振动响应的可靠性及实用性.  相似文献   

3.
砌体结构损伤检测的脉动法   总被引:1,自引:0,他引:1  
应用脉动法测到的信号分析结构的固有频率和振型,利用作者提出的改进的单纯形法来识别结构刚度。根据识别的刚度矩阵,利用结构刚度与层间抗压抗剪强度、砂浆强度之间的关系,则可求得砌体的强度,从而达到对砌体结构进行损伤检测和安全性评定的目的。对某七层砌体结构进行实例,结果表明该方法能够比较准确地对砌体结构进行损伤检测和安全性评定。  相似文献   

4.
5.
An extensive programme of full-scale ambient vibration tests has been conducted to measure the dynamic response of a 542 m (centre span of 274 m) cable-stayed bridge—the Quincy Bayview Bridge in Illinois. A microcomputer-based system was used to collect and analyse the ambient vibration data. A total of 25 modal frequencies and associated mode shapes were identified for the deck structure within the frequency range of 0–2 Hz. Also, estimations were made for damping ratios. The experimental data clearly indicated the occurrence of many closely spaced modal frequencies and spatially complicated mode shapes. Most tower modes were found to be associated with the deck modes, implying a considerable interaction between the deck and tower structure. No detectable levels of motion were evident at the foundation support of the pier. The results of the ambient vibration survey were compared to modal frequencies and mode shapes computed using a three-dimensional finite element model of the bridge. For most modes, the analytic and experimental modal frequencies and mode shapes compare quite well, especially for the vertical modes. Based on the findings of this study, a linear elastic finite element model appears to be capable of capturing much of the complex dynamic behaviour of the bridge with very good accuracy, when compared to the low-level dynamic responses induced by ambient wind and traffic excitations.  相似文献   

6.
When testing multi-storey structures, most testing facilities require the testing of a reduced-scale model. A literature review on tests of scaled masonry structural components revealed that scaling of masonry was rather challenging and often significant differences in stiffness, strength and failure mechanisms between the different sized masonry were reported. This paper addresses the scaling of hollow clay brick masonry with fully mortared head and bed joints. We investigate different choices of scaling brick units and mortar joints. Based on the results of an extensive test programme including standard material tests and quasi-static cyclic tests on masonry walls subjected to horizontal and axial loads, we formulate recommendations for the production of a half-scale model of unreinforced masonry structures. The experimental results show a good match between full-scale and half-scale masonry. We discuss the differences in material properties that remained and compare the force-displacement hystereses obtained for the wall tests.  相似文献   

7.
Traffic and wind excitation has been used to obtain the dynamic characteristics of the first Bosporus (Bogazici) Suspension Bridge. Structural symmetry and the absence of suspended side-spans allowed attention to be focused on the main span and the Asian tower. For the main span, 18 vertical and 20 lateral modes were obtained, including torsional modes. For the tower, 12 longitudinal and 12 lateral modes were identified. All these models lie in the range 0–1-1 Hz. A detailed comparison is given between these modes and corresponding calculated modes, obtained by use of a three-dimensional finite element model which includes a geometric stiffness matrix. Of particular interest is the validity of the theoretical model used for the box-deck, because of its subsequent use in response studies of asynchronous seismic excitation. Comparison with a more limited study made in 1973 shows that the bridge continues to behave as it was designed to behave, particularly with regard to the deck-tower interface. From natural frequency measurements of two hangers, the load which they carry was assessed.  相似文献   

8.
应县木塔环境振动试验   总被引:5,自引:1,他引:5  
对于复杂的塔状古建筑物,建立一个合适的简化的数学模型是不易实现的。与强迫振动试验相比,环境振动试验比较简单、方便,所确定出的小振幅水平下的木塔结构动力特性具有足够的精度。本文首先结合应县木塔结构环境振动测试实例对环境振动测试方法作了简要介绍,并采用随机信号数据频域分析方法对测试数据进行了分析,确定木塔结构的自振频率。同时,依据不同测点在固有频率处响应的比及零迟时互相关函数确定木塔结构的振型。最后,本文依据自功率谱和互功率谱采用半功率点法计算各振型的阻尼比。本文分析结果表明,在两水平方向上木塔的振动特性存在些微差异,第一振型阻尼比较第二振型阻尼比大。  相似文献   

9.
The performance of a building under wind and seismic loads depends on stiffness and mass distribution, and may be estimated using finite element codes. Experience has, however, shown that such finite element models often fail to predict accurately the fundamental natural frequencies. Usually the frequencies will be underestimated, that is the building will turn out to be stiffer than anticipated, meaning the design would usually be conservative. On the other hand, effects like torsional eccentricity and foundation compliance may not be correctly modelled, which could be less desirable. A full understanding of linear performance under lateral loads can be obtained through experimental evaluation of the vibration modes. Traditionally only a limited range of modal analysis procedures and software has been applied to civil applications and the ‘special case’ where no input forces can be measured has been the usual situation for large civil structures. Recent developments in system identification, which is the set of procedures to build mathematical models of the dynamic structural systems based on measured data, have added significantly to the potential of ambient vibration or ‘output only’ testing. The aim of the research reported here has been to apply and evaluate the procedures on typical buildings. The procedures are briefly explained and two experimental programmes are then described; a long‐term tremor monitoring exercise on a 280m office tower and an ambient vibration survey of a smaller office block. The different forms of response data are examined to study the performance of the analysis procedures and expose benefits and limitations in their use. There is a growing interest in output‐only modal analysis procedures in civil engineering. The experience reported in this paper has shown that quick and reliable estimation of mode shapes and frequencies can be obtained, even with small amounts of data. Judgement of modal participation and damping ratios requires more detailed study yet the results are at least as convincing as existing and relatively limited frequency domain methods. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

10.
基于环境振动的斜拉桥拉索基频识别   总被引:16,自引:1,他引:16  
斜拉索是现代斜拉桥最重要的结构构件,索力在斜拉桥的施工控制和长期监测中起着重要作用。振动测试法是斜拉桥索力测定、监测和状态评估中应用最广泛的一种方法。振动法测索力的关键在于准确地识别出索的基频。本文使用自功率谱和倒频谱方法,基于MATLAB平台,开发出了斜拉桥拉索环境振动模态分析图形用户交互(GUI)工具箱,实现了斜拉索基频的快速自动识别。应用本文的方法,对福州青洲闽江主跨605m斜拉桥拉索的环境振动实测加速度数据进行了分析处理,斜拉索基频识别方便直观,结果可靠。  相似文献   

11.
An experimental programme was conducted in which eight full‐scale unreinforced masonry walls were subjected to cyclic face loading using a system of airbags. Of the eight walls, six contained a window opening and four were subjected to vertical pre‐compression. Combined supports at the vertical and horizontal edges ensured that under face loading the walls underwent two‐way bending. The test walls were found to possess good post‐peak strength and displacement capacity as well as reasonable energy dissipation characteristics. Significant strength and stiffness degradation and non‐symmetry of strength in the positive and negative displacement directions were also evident. Discussion of the causes of the aforementioned trends and their implications towards the seismic response of masonry walls is provided. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

12.
Dynamical properties of an anchorage of South Bisan-seto Suspension Bridge are determined by means of in situ measurement of the ambient vibrations. This anchorage, being located in the sea, is tall and slender; its natural frequencies are expected to be low. On the other hand, the elasticity of the ground estimated from the conventional geological data is highly dispersed. It even suggests the possibility of resonance between the towers and this anchorage. It is therefore necessary to know its natural frequencies precisely. Seismic motions and microtremors are acquired and used properly. The observation is repeated every year during the period of construction of the anchorage so that its inertial properties change significantly. First modes of the longitudinal and the transversal vibrations of the anchorage are identified and their frequencies determined. The elasticity modulus estimated from these natural frequencies is about five times as large as that of the geological survey while it is consistent with that obtained from the velocity of the elastic waves of the ground.  相似文献   

13.
In this lecture the particularities of the seismic re-design of Monuments are discussed, related to their structural repair or strengthening. A Monument, besides its possible practical use and its economical value, requires a lot of other Values to be respected during its aseismic retrofitting, such as its aesthetic Form, the authenticity of its materials, etc. In order to respect these Values, the Engineer tends to minimize structural intervention—thus, violating social values such as the preservation of the Monument for future generations, the protection of human lifes, etc. An optimization is needed, and the lecture attempts to describe the necessary procedures to this end. On the other hand, emphasis is given to the particular difficulties in the determination of the resistance of masonry, as well as in the selection of suitable methods of Analysis, taking into account the specificity of each Monument. To this end, the lecture includes comments on monumentic Values and performance requirements, and emphasizes the need for an institutionalization of levels of importance, levels of visitability and of acceptable damage-levels for all monuments of each Country, as a basic input of aseismic design of monuments. Subsequently, criteria are given for the selection of methods of Analysis, and detailed comments are included about experimental investigations and strengths’ determination. The final optimization procedure is then described, regarding the optimum seismic resistance level to be lent to a specific Monument.  相似文献   

14.
This paper describes ambient vibration based seismic evaluation procedure of an isolated highway bridge. The procedure includes finite element modeling, ambient vibration testing, finite element model updating and time history analysis. Gülburnu Highway Bridge located on the Giresun–Espiye state highway is selected as a case study. Three dimensional finite element model of the bridge is created by SAP2000 software to determine the dynamic characteristics analytically. Since input force is not measured, Operational Modal Analysis is applied to identify dynamic characteristics. Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification methods are used to obtain experimental dynamic characteristics. Analytical and experimental dynamic characteristic are compared with each other and finite element model of the bridge is updated by changing of material properties to reduce the differences between the results. Analytical model of the bridge after model updating is analyzed using 1992 Erzincan earthquake record to determine the seismic behavior. EW, NS and UP components of the ground motion are applied to the bridge at the longitudinal, transverse and vertical directions, respectively. It is demonstrated that the ambient vibration measurements are enough to identify the most significant modes of highway bridges. Maximum differences between the natural frequencies are reduced averagely from 9% to 2% by model updating. It is seen from the earthquake analyses that friction pendulum isolators are very effective in reducing the displacements and internal forces.  相似文献   

15.
The dynamic identification of a historical masonry palace located in Benevento (Italy) has been carried out. The case study is representative of many buildings located in historic Italian centres. Since the building has been instrumented by the Department of Civil Protection with a permanent dynamic monitoring system, some of the recorded data, acquired in various operating conditions have been analysed with basic instruments of the Operational Modal Analysis in order to identify the main eingenfrequencies and vibration modes of the structure. The experimental results have been compared to the numerical outcomes provided by a detailed three-dimensional Finite Element (FE) model of the building where Soil–Structure Interaction (SSI) has been taken into account. The comparison of experimental vs. numerical frequencies and vibration modes of the palace evidenced the role exerted by the subsoil on the dynamic response of the building.  相似文献   

16.
Measurement of the vibration frequencies of eight ties set in masonry arches of a church by means of a robotic total station is described.The instrument made continuous recordings(up to ten per second) of the three-dimensional positions of a reflector situated at 1/2 or 1/4 of the length of the tie during vertical oscillation induced by an impulsive load.The recording slips,vibration amplitudes(and their accuracy),hourly diagram and experimental spectra of vibrations,and the corresponding freque...  相似文献   

17.
通过贮仓-地基相互作用系统的振动试验,研究了贮仓的动力反应特点,研究表明,地基的特性对贮仓的振动有着明显的影响,因此在研究贮仓的动力反应时,应该考虑贮仓与地基的相互作用。  相似文献   

18.
19.
20.
The basic aspects of testing small-scale masonry building models on simple earthquake simulators are discussed. Since the scale effects represent a difficult problem to solve, the overall seismic behaviour of structural systems, and not the behaviour of structulal details, has been studied by testing the reduced-sized models on a simple earthquake simulator. Accurate results regarding the dynamic behaviour and failure mechanism of the tested structures have been obtained by means of testing the relatively simple, adequately designed small-scale masonry building models. A simple earthquake simulator capable of simulating the uni-directional earthquake ground motion has been developed to study the seismic behaviour of masonry building models. Although a multipurpose programmable actuator was used to drive the shaking table, the comparison of the dynamic characteristics of the generated shaking-table motion and the earthquake acceleration records used for the simulation of seismic loads showed an acceptable degree of correlation between the input and output seismic motion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号